HomeMy WebLinkAboutH-601 - HVAC DETAILSROOF INSTALL CURBS PER NRCA AND MFGRS RECOMMENDATIONS EQUIPMENT SUPPORT CURB OR RAIL (TYPICAL) WOOD NAILER FIELD APPLIED CANT EQUIPMENT BASE REFER TO STRUCTURAL DWGS FOR SUPPORT ATTACHMENT TO STRUCTURE BELOW ROOF, SEE ARCH PLANS FOR DETAILS CONDENSING UNIT CAULK OR GASKET NOTES: 1. PROVIDE 2 - 1-1/4" WIDE METAL STRAPS OVER TOP OF UNIT, ONE ON EACH SIDE. STRAPS SHALL BE ANCHORED TO EQUIPMENT RAILS AT THE BASE. STRAPS SHALL BE PRIMED AND PAINTED WHITE, 2 COATS EACH MINIMUM, ON BOTH SIDES PRIOR TO INSTALL. 2. PROVIDE 2 - #14 LAG BOLTS, SPACED 5/8" APART, AT THE END OF EACH METAL STRAP. BOLTS SHALL GO THROUGH METAL STRAPPING AND INTO WOOD NAILER OF EQUIPMENT RAILS TO ANCHOR UNIT TO EQUIPMENT RAILS. 3. STRAPS SHALL BE PLACED A MINIMUM OF 3" IN FROM TOP EDGE OF UNIT. 4. STRAPPING SHALL BE VERIFIED BY EQUIPMENT MANUFACTURER TO ENSURE ADEQUATE RESTRAINT OF SUPPLIED EQUIPMENT AT 115 MPH WIND LOAD. ANY DEVIATIONS FROM ABOVE MUST BE SUBMITTED TO ENGINEER FOR REVIEW. CONDENSING UNIT DOOR MIN. 30" WATER HEATER PAN WATER HEATER FAN COIL UNIT PLENUM CLEARANC E RACK REFRIGERANT LINE SETS ON SIDE WALL OF MECH ROOM RETURN GRILLE, SEE PLANS CONDENSATE DRAIN; ROUTE TO HUB DRAIN MAIN SHUT-OFF POSSIBLE FUTURE TENANT SUBMETE R WATER HEATE R PAN SLEEVE FLEX CONN. DUCTFIRE DAMPER W/ACCESS PANEL FAN COIL UNIT WATER HEATER HW CW VALVE (TYP.) SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN, REFER TO MECHANICAL AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATIO N DAMPER PLENUM BOX OR ELBOW, R/D=1.5 MIN. 15.2"9'-0" REFER TO PLANS13" MINNOM. 41"12"MIN.NOM.36"FOAM SEAL BETWEEN DOOR AND FAN COIL SUPPORT SHELF4"NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO HUB DRAIN. 2. REFER TO STRUCTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOISTS. 3. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE PROTECTION AND PLUMBING PIPING PRIOR TO INSTALLATION. 4. FIRESTOP ALL PENETRATIONS AT CEILING, FLOOR AND THROUGH FCU SUPPORT. NOM. 30" FIRE RATED RATED PLYWOOD FLOOR ON FAN COIL SUPPORT SHELF. SUPPORT SHELF BY CONTRACTOR. FASTEN FIRE DAMPER FRAME TO SLEEVE AS REQUIRED BY U.L. LABEL DUCT CONNECTOR-FULL WIDTH OF SLEEVE REQUIRED AT TOP ONLY 'S'-SLIP TYPICAL CONNECTION TO DUCTWORK 160°F FUSIBLE LINK CONNECT DUCT TO DAMPER COLLAR BOTH SIDES OF PARTITION AS REQUIRED BY U.L. LABEL ANGLES 1 1/2"x1 1/2"x1/8" MINIMUM; FASTENED TO SLEEVE AS REQUIRED BY U.L. LABEL; ANGLES TO LAP MASONRY OPENING MINIMUM 1" FIRE RATED FLOOR OR PARTITION TOP BLADE RIVETED TO FRAME WALL SLEEVE; MINIMUM 16 GA. FOR DAMPERS NOT EXCEEDING 36"Wx24"H AND 14 GAUGE FOR LARGER SIZES NOTE: PROVIDE HINGED OR DOUBLE CATCH ACCESS DOOR SIZED AND LOCATED TO PERMIT REPLACEMENT OF FUSIBLE LINK LABELED "FIRE DAMPER ACCESS" DUCT CONNECTOR-FULL WIDTH OF SLEEVE REQUIRED AT TOP ONLY ROOF MEMBRANE PIPE INSULATION BASE GALVANIZED CHANNEL SECURE PIPING TO SUPPORT WITH STRAPFLOOR TO FLOOR STRUCTURE OR BULKHEADALL CONCEALED 4" DRYER DUCT SHALL BE NON- CORRUGATED SMOOTH METAL WITHOUT SCREWS. EXTERIOR WALL CAP WITHOUT SCREEN. 24"x10" TRANSFER GRILLES ON EACH SIDE, CENTERED ABOVE DOOR. (160 SQ. IN.) DRYER BOX IN SIDE WALL MOUNTED AT 4" A.F.F. 0' - 4"1' - 9"MOTOR DISCONNECT SWITCH BY UNIT MFGR. PIGTAIL CORD EXTERNAL ALUM. WIRE POST BY UNIT MFGR. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION AUTO BACKDRAFT DAMPER SEE PLANS FOR DUCT SIZE ALUM. HOUSING FAN WHEEL BIRDSCREEN FLASH AND COUNTERFLAS H 16" HIGH PRE-FAB CURB PROVIDE HOLE THRU ROOF ROUTE WIRE OUTSIDE DAMPER, BY OTHERS ROOF CURB CAP WALL SLEEVE FAN HOUSING REAR GUARD SCREEN MOTOR FAN GRAVITY BACKDRAF T DAMPER WALL -SEE ARCHITECTURAL PLANS LOUVER STACKED WASHER AND DRYER 4" DIA DRYER DUCT ROUTES UP IN WALL DRYER BOX LINT TRAP, PAINT METAL TO MATCH WALL FINISH MOUNT 7' A.F.F. DRYER DUCT ROUTES OUT OF BUILDING 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.H-601 HVAC DETAILS 08/31/202108/31/2021 THOMAS KENNEDY JOE BOLYARD NOT TO SCALE FCU Above Water Heater DetailB NOT TO SCALE Fire Damper Installation DetailC NOT TO SCALE Pipe Roof Support DetailD NOT TO SCALE Typical Dryer Vent Connection DetailE NOT TO SCALE Typical Exhaust Fan (Flat) DetailF NOT TO SCALE Wall Mounted Exhaust Fan Detail - Direct DriveG NOT TO SCALE Lint Trap Above Dryer Box DetailH NOT TO SCALE Condensing Unit Support DetailA 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFE S S IONA L E N G INEERDATE SIGNED 08/31/21REGISTER E D I ND I A N A