HomeMy WebLinkAboutM-000 - MECHANICAL SYMBOLS, LEGENDS & ABBREVIATIONSAD CO2 TST H T P T F DPT N 0 16'8'4'SCALE: X X X X X X CHECK VALVE PRESSURE REDUCING VALVE BACKFLOW PREVENTER DUCTWORK LINING OR DOUBLE WALL DUCTWORK, DESIGNATION SHOWN IS FREE AREA AIR SEPARATOR TU-XL.## DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER SUPPLY (HW) DOMESTIC HOT WATER RETURN (HWR) 140°F HOT WATER 140°F HOT WATER RETURN NON-POTABLE WATER SOFT COLD WATER DEIONIZED WATER FIRE SUPPRESSION NATURAL GAS (WC OR PSIG) GAS VENT LIQUID PETROLEUM CONDENSATE DRAIN MEDICAL COMPRESSED AIR (WC OR PSIG) STORM DRAIN MEDICAL VACUUM UNDERSLAB/FOUNDATION DRAIN OXYGEN SANITARY WASTE OR SOIL (W)NITROGEN SANITARY GREASE NITROUS OXIDE SANITARY FORCED MAIN CARBON DIOXIDE SANITARY VENT (V)COMPRESSED AIR (WC OR PSIG) ACID WASTE ACID VENT DRAIN INDIRECT WASTE PUMP DISCHARGE ERV ENERGY RECOVERY VENTILATOR FLOW DIRECTION ARROW, PITCH DIRECTION ARROW PIPE RISE PIPE DROP PIPE CAP PIPE CONTINUES (REFERENCE ELSEWHERE) PIPE GUIDE PIPE ANCHOR FLEXIBLE CONNECTOR EXPANSION COMPENSATOR EXPANSION LOOP CONCENTRIC, ECCENTRIC FITTINGS UNION SHUT-OFF VALVE, SEE SPECS ANGLE VALVE RELIEF VALVE VALVE WITH OUTSIDE STEM & YOKE TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE SOLENOID TWO-WAY CONTROL VALVE FLOW SWITCH PRESSURE SWITCH AQUASTAT ORIFICE FLOW METER VENTURI FLOW METER / FLOW MEASURING STATION STRAINER WITH CAPPED BLOWDOWN MANUAL AIR VENT AUTOMATIC AIR VENT VACUUM BREAKER THERMOMETER PRESSURE GAUGE INLINE PUMP DIFFERENTIAL PRESSURE TRANSMITTER WATER HAMMER ARRESTER WITH SCHEDULE TYPE P-TRAP AND RISER FLOOR DRAIN WITH SIZE & SCHEDULE TYPE END OF PIPE CLEANOUT FLOOR CLEANOUT WALL CLEANOUT EXTERIOR CLEANOUT OR RODDING HOLE THERMOSTATIC MIXING VALVE WITH SCHEDULE TYPE HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE WATER METER GAS METER ROOF DRAIN, OVERFLOW DRAIN WITH SIZE POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION VALVE TAMPER SWITCH UPRIGHT SPRINKLER HEAD PENDANT SPRINKLER HEAD DRY PENDANT SPRINKLER HEAD CONCEALED SPRINKLER HEAD SIDEWALL SPRINKLER HEAD RECTANGULAR DUCTWORK DESIGNATION IN INCHES, FIRST DIMENSION IS SIDE SHOWN ROUND SPIRAL DUCTWORK DESIGNATION IN INCHES FLAT OVAL DUCTWORK DESIGNATION IN INCHES, FIRST DIMENSION IS SIDE SHOWN RECTANGULAR SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE RECTANGULAR SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP RECTANGULAR RETURN AIR, TRANSFER AIR DUCTWORK RISE ROUND SPIRAL RETURN AIR, TRANSFER AIR DUCTWORK RISE FLAT OVAL RETURN AIR, TRANSFER AIR DUCTWORK RISE RECTANGULAR RETURN AIR, TRANSFER AIR DUCTWORK DROP ROUND SPIRAL RETURN AIR, TRANSFER AIR DUCTWORK DROP FLAT OVAL RETURN AIR, TRANSFER AIR DUCTWORK DROP RECTANGULAR EXHAUST AIR, RELIEF AIR DUCTWORK RISE ROUND SPIRAL EXHAUST AIR, RELIEF AIR DUCTWORK RISE FLAT OVAL EXHAUST AIR, RELIEF AIR DUCTWORK RISE RECTANGULAR EXHAUST AIR, RELIEF AIR DUCTWORK DROP ROUND SPIRAL EXHAUST AIR, RELIEF AIR DUCTWORK DROP FLAT OVAL EXHAUST AIR, RELIEF AIR DUCTWORK DROP DUCTWORK CONSTRUCTED OF ALUMINUM, STAINLESS STEEL DUCTWORK RISE IN DIRECTION OF FLOW DUCTWORK DROP IN DIRECTION OF FLOW SUPPLY AIR, OUTSIDE AIR IN DIRECTION OF FLOW RETURN AIR, EXHAUST AIR, TRANSFER AIR, RELIEF AIR IN DIRECTION OF FLOW ECCENTRIC DUCT TRANSITION CONCENTRIC DUCT TRANSITION RECTANGULAR TO ROUND, FLAT OVAL DUCT TRANSITION BALANCE OR VOLUME DAMPER ACCESS DOOR DUCTWORK CAP 45° BEVELED FITTING FOR RECTANGULAR TO RECTANGULAR DUCTWORK RADIUS DUCTWORK ELBOW (CENTERLINE RADIUS 1.5xW)SOUND ATTENUATOR CONICAL FITTING FOR ROUND OR FLAT OVAL TO RECTANGULAR DUCTWORK RADIUS DUCTWORK ELBOW WITH TURNING VANES MITERED DUCTWORK ELBOW CONICAL FITTING FOR ROUND OR FLAT OVAL TO ROUND OR FLAT OVAL DUCTWORK WYE RADIUS DUCTWORK ELBOW MITERED DUCTWORK ELBOW WITH TURNING VANES 45° LATERAL FITTING FOR ROUND OR FLAT OVAL TO ROUND OR FLAT OVAL DUCTWORK 45° RADIUS DUCTWORK ELBOW (CENTERLINE RADIUS 1.5xW) TRANSFER AIR ELBOW WITH DUCTWORK STUBS FOR SOUND ATTENUATION SPIN-IN FITTING FOR ROUND TO RECTANGULAR DUCTWORK, LOW PRESSURE DUCTWORK CEILING PANEL SUPPLY AIR DIFFUSER ROUND SUPPLY AIR DIFFUSER FLEXIBLE DUCTWORK CONNECTION TO DIFFUSER, MAXIMUM SIX FEET RECTANGULAR SUPPLY AIR REGISTER OR GRILLE RETURN AIR, TRANSFER AIR REGISTER OR GRILLE EXHAUST AIR REGISTER OR GRILLE LINEAR SLOT SUPPLY AIR DIFFUSER SIDEWALL SUPPLY AIR REGISTER OR GRILLE SIDEWALL RETURN AIR, EXHAUST AIR, TRANSFER AIR REGISTER OR GRILLE DOOR GRILLE OR UNDERCUT DOOR THERMOSTAT WITH ASSOCIATED EQUIPMENT DESIGNATION TEMPERATURE SENSOR CEILING DESTRATIFICATION FAN HUMIDISTAT WITH ASSOCIATED EQUIPMENT DESIGNATION CARBON DIOXIDE OR MONOXIDE SENSOR CENTRIFUGAL ROOF EXHAUST FAN HYDRONIC REHEAT COIL WITH ACCESS DOOR SINGLE DUCT VAV BOX INLINE FAN ELECTRIC REHEAT COIL WITH ACCESS DOOR SERIES/PARALLEL FAN POWERED TERMINAL UNIT BASE MOUNTED PUMP UNIT HEATER SECTION INDICATOR:REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. PLAN NOTE INDICATOR:REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR:REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR:REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR:REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. EQUIPMENT INDICATOR:REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. DIFFUSER, GRILLE, REGISTER INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. MAKE UP WATER AIR RELIEF VENT HEATING WATER SUPPLY HEATING WATER RETURN REFRIGERANT DISCHARGE REFRIGERANT SUCTION REFRIGERANT LIQUID REFRIGERANT HOT GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN LINETYPE DESIGNATORS THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS. INTERMEDIATE DASHED LINETYPE INDICATE ITEMS TO BE REMOVED ON COMBINATION PLANS. INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE WORK TO BE INCLUDED. THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE. INDICATES POINT OF CONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. SHEET TYPE DESIGNATORS 000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) 100 PLANS 200 PLANS (SECONDARY) 300 ENLARGED PLANS & SECTIONS 400 SCHEMATICS & DIAGRAMS 500 SCHEDULES 600 DETAILS 700 CONTROL DIAGRAMS 800 (USER DEFINED) 900 3D REPRESENTATIONS (ISOMETRICS) NOTATION DESIGNATORS GENERAL MECHANICAL NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE DISCIPLINE. GENERAL SHEET NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR. SHEET PLAN NOTES:NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A PLAN NOTE INDICATOR TO IDENTIFY ITEMS. ∅DIAMETER, PHASE ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE (°F) °F DEGREES FAHRENHEIT EW EMERGENCY EYEWASH OBD OPPOSED BLADE DAMPER A/C AIR CONDITIONING EWC ELECTRIC WATER COOLER OD OUTSIDE DIAMETER, OVERFLOW DRAIN AAV AIR ADMITTANCE VALVE EWT ENTERING WATER TEMPERATURE (°F)OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED ACC AIR COOLED CONDENSER EXH EXHAUST OFD OVERFLOW ROOF DRAIN ACCU AIR COOLED CONDENSING UNIT EXIST/EX EXISTING OSD OPEN SITE DRAIN AD AREA DRAIN, ACCESS DOOR F FURNACE OZ OUNCE AFF ABOVE FINISHED FLOOR F&T FLOAT AND THERMOSTATIC STEAM TRAP P PUMP AFG ABOVE FINISHED GRADE FCO FLOOR CLEANOUT PBD PARALLEL BLADE DAMPER AFMS AIR FLOW MEASURING STATION FCU FAN COIL UNIT PC PLUMBING CONTRACTOR AFUE ANNUAL FUEL UTILIZATION EFFICIENCY FD FLOOR DRAIN, FIRE DAMPER PD PRESSURE DROP AGA AMERICAN GAS ASSOCIATION FDC FIRE DEPARTMENT CONNECTION PE PNEUMATIC ELECTRIC AHU AIR HANDLING UNIT FDTN FOUNDATION PH PHASE AL ACOUSTICALLY LINED, ALUMINUM FE FIRE EXTINGUISHER PIV POST INDICATOR VALVE AMB AMBIENT FHC FIRE HOSE CABINET PPM PARTS PER MILLION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE FLR FLOOR PRV PRESSURE REDUCING VALVE AO ANALOG OUTPUT FM FACTORY MUTUAL PSI POUNDS PER SQUARE INCH AP ACID PROOF, ACCESS PANEL FPM FEET PER MINUTE PSIG POUNDS PER SQUARE INCH GAUGE APD AIR PRESSURE DROP (IN. WC.)FPVAV FAN POWERED VAV UNIT PTAC PACKAGED TERMINAL AIR CONDITIONER ARCH ARCHITECT FS FLOOR SINK PVC POLYVINYL CHLORIDE ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE FSC FIRE SUPPRESSION CONTRACTOR R REGISTER, REFRIGERANT ARV AIR RELIEF VALVE FSD COMBINATION FIRE/SMOKE DAMPER RA RETURN AIR AS AIR SEPARATOR FT FOOT, FEET RAD RADIATION ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING FTG FOOTING RAT RETURN AIR TEMPERATURE (°F) AND AIR CONDITIONING ENGINEERS FTR FINNED TUBE RADIATION RCP REINFORCED CONCRETE PIPE ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS G NATURAL GAS RD ROOF DRAIN ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS GA GAGE OR GAUGE REV REVOLUTIONS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS GAL GALLON RF RETURN FAN ATM ATMOSPHERE GC GENERAL CONTRACTOR RG RETURN GRILLE AUTO AUTOMATIC GIV GRAVITY INTAKE VENTILATOR RH RELATIVE HUMIDITY, ROOF HYDRANT AV AUTOMATIC VENT GPD GALLONS PER DAY RM ROOM AVG AVERAGE GPH GALLONS PER HOUR RP RADIANT PANEL AVS ACID VENT STACK GPM GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE AW ACID WASTE GR GRILLE, GRAINS RPS REVOLUTIONS PER SECOND AWWA AMERICAN WATER WORKS ASSOCIATION GRV GRAVITY RELIEF VENTILATOR RTU ROOF TOP UNIT BD BUTTERFLY DAMPER GT GREASE TRAP RV RELIEF VALVE, ROOF VENT BDD BACKDRAFT DAMPER HB HOSE BIBB SA SUPPLY AIR BE BOTTOM ELEVATION HD HEAD (FT.)SAN SANITARY BHP BRAKE HORSEPOWER Hg MERCURY SD SUPPLY DIFFUSER, SMOKE DAMPER BLDG BUILDING HWP HEATING HOT WATER PUMP SEER SEASONAL ENERGY EFFICIENCY RATIO BOD BOTTOM OF DUCT HO HUB OUTLET SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR BOP BOTTOM OF PIPING HORIZ HORIZONTAL SG SUPPLY GRILLE BSMT BASEMENT HP HORSEPOWER, HEAT PUMP SU SHOWER UNIT BT BATHTUB HR HOUR(S)SK SINK BTM BOTTOM HRTU HEATING ONLY ROOFTOP UNIT SMACNA SHEET METAL AND AIR CONDITIONING BtuH BRITISH THERMAL UNIT PER HOUR HRV HEAT RECOVERY VENTILATOR CONTRACTORS NATIONAL ASSOCIATION CA COMPRESSED AIR HX HEAT EXCHANGER SP STATIC PRESSURE CAV CONSTANT AIR VOLUME Hz HERTZ SPEC SPECIFICATION CB CATCH BASIN IB INVERTED BUCKET STEAM TRAP SQ SQUARE CCW COUNTERCLOCKWISE ID INSIDE DIAMETER SR SUPPLY REGISTER CD CONDENSATE DRAIN IN INCH, INCHES SRV SAFETY RELIEF VALVE CO₂CARBON DIOXIDE INT INTERIOR SS SERVICE SINK, STAINLESS STEEL CFM CUBIC FEET PER MINUTE INV EL INVERT ELEVATION STD STANDARD CH CHILLER IPS INTERNATIONAL PIPE STANDARD SV STEAM VENT CHP CHILLED WATER PUMP IW INDIRECT WASTE TCC TEMPERATURE CONTROL CONTRACTOR CI CAST IRON KEC KITCHEN EQUIPMENT CONTRACTOR TCP TEMPERATURE CONTROL PANEL CMP CORRUGATED METAL PIPE kW KILOWATT TD TEMPERATURE DIFFERENCE CO CLEANOUT / CARBON MONOXIDE LAB LABORATORY TE TOP ELEVATION COMPR COMPRESSOR LAT LEAVING AIR TEMPERATURE (°F)TEMP TEMPERATURE COND CONDENSER L LAVATORY TF TRANSFER FAN CONV CONVECTOR LBS POUNDS TG TRANSFER GRILLE CP CONDENSATE PUMP LD LINEAR DIFFUSER TMV THERMOSTATIC MIXING VALVE CPVC CHLORINATED POLYVINYL CHLORIDE LP LIQUID PETROLEUM TONS TONS OF REFRIGERATION CT COOLING TOWER LTG LIGHTING TP TRAP PRIMER CU CONDENSING UNIT LWT LEAVING WATER TEMPERATURE (°F)TRANS TRANSITION CUH CABINET UNIT HEATER MA MIXED AIR TS TAMPER SWITCH, TUB SHOWER CUV CLASSROOM UNIT VENTILATOR MAT MIXED AIR TEMPERATURE (°F)TSP TOTAL STATIC PRESSURE (IN. WC.) CV CONTROL VALVE MAX MAXIMUM TXV THERMAL EXPANSION VALVE CW CLOCKWISE MB MOP BASIN TYP TYPICAL CWP CONDENSER WATER PUMP MBH THOUSAND Btu PER HOUR UC UNDERCUT DOOR dB DECIBEL MC MECHANICAL CONTRACTOR UH UNIT HEATER DB DRY BULB MCA MINIMUM CIRCUIT AMPS UL UNDERWRITERS LABORATORIES DF DRINKING FOUNTAIN MCC MOTOR CONTROL CENTER UNO UNLESS NOTED OTHERWISE DG DOOR GRILLE MD MOTORIZED DAMPER UR URINAL DH DUCT HEATER MFR MANUFACTURER UV UNIT VENTILATOR, ULTRAVIOLET DI DIGITAL INPUT, DISTILLED WATER MH MANHOLE V VOLTS, VENT DIA DIAMETER MIN MINIMUM VAC VACUUM DN DOWN MISC MISCELLANEOUS VAV VARIABLE AIR VOLUME DO DIGITAL OUTPUT MS MOP SINK VB VACUUM BREAKER DS DOWNSPOUT, DOWN STREAM MTD MOUNTED VD VOLUME DAMPER DWG DRAWING MV MANUAL VENT VEL VELOCITY DWH DOMESTIC WATER HEATER N NITROGEN VERT VERTICAL DWV DRAIN, WASTE & VENT NA NOT APPLICABLE VF VENTILATION FAN DX DIRECT EXPANSION NC NOISE CRITERIA, NORMALLY CLOSED VFD VARIABLE FREQUENCY DRIVE EA EXHAUST AIR NEC NATIONAL ELECTRIC CODE VTR VENT THROUGH ROOF EAT ENTERING AIR TEMPERATURE (°F)NFC NATIONAL FIRE CODE W WASTE, WATT EC ELECTRICAL CONTRACTOR NFPA NATIONAL FIRE PROTECTION ASSOCIATION WC WATER COLUMN ECO EXTERIOR CLEANOUT NFWH NON-FREEZE WALL HYDRANT WB WET BULB EDR EQUIVALENT DIRECT RADIATION NIC NOT IN CONTRACT WC WATER CLOSET EER ENERGY EFFICIENCY RATIO NO NORMALLY OPEN, NITROUS OXIDE WCO WALL CLEANOUT EF EXHAUST FAN NOM NOMINAL WH WALL HYDRANT EFF EFFICIENCY NPW NON-POTABLE WATER WPD WATER PRESSURE DROP (FT. HD.) EG EXHAUST GRILLE NTS NOT TO SCALE WSHP WATER SOURCE HEAT PUMP EL ELEVATION O OXYGEN YD YARD DRAIN EOM END OF MAIN DRIP OA OUTSIDE AIR OAI OUTSIDE AIR INTAKE ES EMERGENCY SHOWER ESP EXTERNAL STATIC PRESSURE (IN. WG.) DISCIPLINE DESIGNATORS M-000 MECHANICAL FP000 FIRE SUPPRESSION P-000 PLUMBING PD000 PLUMBING DEMOLITION H-000 HVAC HD000 HVAC DEMOLITION HP000 HVAC PIPING PIPING IDENTITY SYMBOLS HVAC IDENTITY SYMBOLS REFERENCE SYMBOLSPIPING LINE SYMBOLS ABBREVIATIONS AND TERMS GENERAL MECHANICAL NOTES X X SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET PLAN NOTE INDICATORS EQUIPMENT TYPE NUMERIC CHARACTER RELATES TO ITEM ALPHANUMERIC CHARACTER RELATES TO ASSOCIATED AIR HANDLER (OPTIONAL) AREA LEADER LINE LEADER POINT LEADER DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) REVISION CLOUD REVISION INDICATOR GRAPHIC SCALENUMERIC SCALE SEE XXX REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN PLAN NUMERIC CHARACTER RELATES TO ITEM NORTH ARROW BEYOND AREA EXTENSION ALPHANUMERIC CHARACTER RELATES TO BUILDING LEVEL (OPTIONAL) DRAWING TITLE 1/8" = 1'-0"X X X SHEET PLAN NOTES 1. AIRFLOW (CUBIC FEET PER MINUTE) NECK SIZE SCHEDULE TYPE AIRFLOW (CUBIC FEET PER MINUTE) SIZE SCHEDULE TYPE AIRFLOW (CUBIC FEET PER MINUTE) NO. OF SLOTS -LENGTH SCHEDULE TYPE DIFFUSER REGISTER/GRILLE SLOT/LINEAR DIFFUSER SA R DALSS AD CO M G CO 4"RD 4"OFD 24/12 24ø 24/12 FO NO N O MV MA GV LP G F DE HWR 140 HW 140 PD D AV AW USD ST RHG CD RL CHR CHS CR CS RS RD HR HS ARV MU FM SG IW A (TU-12.34) (TU-12.34) CO2 NPW FD HB-1 WH-1 FCO 2"FD-1 WCO ECO TMV-1 WHA-A NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTW SCW X X X X X X X X X 1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BIDDING AND BEFORE BEGINNING WORK. 2. REVIEW WORK OF OTHER TRADES. COORDINATE AND PLAN WORK WITH THE OTHER TRADES. ADJUST AS A RESULT OF COORDINATION. REVIEW COORDINATED EFFORTS WITH ENGINEER FOR APPROVAL. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED ITEMS. THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR. 4. STORE EQUIPMENT AND COMPONENTS IN A CLEAN, DRY LOCATION UNTIL READY FOR INSTALLATION. PROTECT FROM WEATHER, THEFT, DIRT, FUMES, WATER, CONSTRUCTION DEBRIS, ETC. AT ALL TIMES. ANY DAMAGED EQUIPMENT OR COMPONENT SHALL BE RESTORED AS NEW OR REPLACED. 5. MECHANICAL DRAWINGS SHOW THE INTENDED ARRANGEMENT AND ROUTING OF ALL PIPING, DUCTWORK, EQUIPMENT AND APPURTENANCES. THEY SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES SHALL BE PROVIDED AS REQUIRED. 6. PERFORM ALL WORK IN A SKILLED, PROFESSIONAL MANNER MEETING THE ACCEPTANCE OF THE ENGINEER, ARCHITECT AND OWNER. 7. LABEL ALL ROOM THERMOSTATS AND/OR SENSOR DEVICES AS TO WHAT THE DEVICE CONTROLS WITH A PLASTIC ENGRAVED LABEL AFFIXED TO THE COVERS. 8. SMALLEST HVAC PIPE SIZE ALLOWABLE IS 3/4" UNLESS NOTED OTHERWISE. 9. MOUNTING HEIGHTS OF DEVICES SHALL FOLLOW THE LISTING BELOW UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS:THERMOSTAT OR TEMPERATURE/HUMIDITY SENSOR... +46" TO TOP 10. PAINT PIPING IN MECHANICAL ROOMS. REFER TO SPECIFICATIONS FOR COLOR CODING. PREPAINT ALL STEEL CHILLED WATER PIPING PRIOR TO INSULATING. 11. CLEAN ALL EQUIPMENT TO PRESENT A 'LIKE NEW' CONDITION AT PROJECT COMPLETION. VACUUM CLEAN INTERNAL AREAS OF EQUIPMENT AND PANELS. 12. CLEAN ALL MECHANICAL AND ELECTRICAL AREAS AND ROOMS OF DEBRIS AND UNUSED MATERIALS. VACUUM FLOORS. 13. OFFSET PIPING AND DUCTWORK AROUND ELECTRICAL PANELS TO PROVIDE CLEARANCES AS REQUIRED BY NATIONAL ELECTRICAL CODE. 14. REFERENCE THE ARCHITECTURAL ELEVATIONS FOR LOCATIONS OF ALL MECHANICAL ITEMS INTERFACING OR ARE WITHIN THE EXTERIOR WALLS. (I.E. WALL HYDRANTS, LOUVERS, ETC.). 15. DEMOLITION/REMODEL A. ALL MATERIALS REMOVED AND NOT RELOCATED BECOME THE PROPERTY OF THE CONTRACTOR. REMOVE MATERIALS FROM THE PROJECT SITE UNLESS NOTED OTHERWISE. OWNER HAS THE OPTION TO REVIEW ITEMS PRIOR TO REMOVAL AND RETAIN IF DESIRED. B. PATCH WALLS, FLOORS, CEILINGS, COLUMNS, ROOF PENETRATIONS, ETC. WHERE ITEMS ARE REMOVED TO MATCH FINISH OF ADJACENT SURFACES. C. RELOCATE EXISTING ITEMS AS REQUIRED FOR INSTALLATION OF WALLS, CEILINGS, DUCTWORK AND PIPING EQUIPMENT. D. REMOVE ALL PIPING, DUCTWORK, CONTROLS, SUPPORTS, ETC. MADEUNNECESSARY OR OBSOLETE AS A RESULT OF THIS PROJECT. E. ALL ITEMS WITH NOTATION 'EX' ARE TO REMAIN. F. ALL ITEMS WITH NOTATION 'R' ARE RELOCATED, AS NOTED. 16. VERIFY DIMENSIONS GIVEN IN THE ARCHITECTS PLANS FOR EXACT LOCATIONS. IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. 17. REFER TO MANUFACTURER'S INSTALLATION AND TEMPLATE DRAWINGS FOR ALL MECHANICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATORS, SPRING ISOLATION, ETC. 18. BRANCH DUCTWORK TO DIFFUSER SHALL BE SAME SIZE AS DIFFUSER INLET UNLESS SPECIFICALLY LABELED OTHERWISE. FSAFMS FLEXIBLE DUCTWORK CONNECTION MOTORIZED DAMPER WITH ACCESS DOOR FIRE DAMPER WITH ACCESS DOOR SMOKE DAMPER WITH ACCESS DOOR AIRFLOW MEASURING STATION WITH ACCESS DOOR FIRE AND SMOKE DAMPER WITH ACCESS DOOR M F S 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.M-000 MECHANICAL SYMBOLS, LEGENDS & ABBREVIATIONS 08/31/202108/31/2021 THOMAS KENNEDY JOE BOLYARD 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFE S S IONA L E N G INEERDATE SIGNED 08/31/21REGISTER E D I ND I A N A