HomeMy WebLinkAboutM-000 - MECHANICAL SYMBOLS, LEGENDS & ABBREVIATIONSAD
CO2
TST
H
T
P
T
F
DPT
N
0 16'8'4'SCALE:
X
X
X
X
X
X
CHECK VALVE
PRESSURE REDUCING VALVE
BACKFLOW PREVENTER
DUCTWORK LINING OR DOUBLE
WALL DUCTWORK, DESIGNATION
SHOWN IS FREE AREA
AIR SEPARATOR
TU-XL.##
DOMESTIC COLD WATER (CW)
DOMESTIC HOT WATER SUPPLY (HW)
DOMESTIC HOT WATER RETURN (HWR)
140°F HOT WATER
140°F HOT WATER RETURN
NON-POTABLE WATER
SOFT COLD WATER
DEIONIZED WATER
FIRE SUPPRESSION
NATURAL GAS (WC OR PSIG)
GAS VENT
LIQUID PETROLEUM
CONDENSATE DRAIN MEDICAL COMPRESSED AIR (WC OR PSIG)
STORM DRAIN MEDICAL VACUUM
UNDERSLAB/FOUNDATION DRAIN OXYGEN
SANITARY WASTE OR SOIL (W)NITROGEN
SANITARY GREASE NITROUS OXIDE
SANITARY FORCED MAIN CARBON DIOXIDE
SANITARY VENT (V)COMPRESSED AIR (WC OR PSIG)
ACID WASTE
ACID VENT
DRAIN
INDIRECT WASTE
PUMP DISCHARGE
ERV ENERGY RECOVERY VENTILATOR
FLOW DIRECTION ARROW, PITCH DIRECTION ARROW
PIPE RISE
PIPE DROP
PIPE CAP
PIPE CONTINUES (REFERENCE ELSEWHERE)
PIPE GUIDE
PIPE ANCHOR
FLEXIBLE CONNECTOR
EXPANSION COMPENSATOR
EXPANSION LOOP
CONCENTRIC, ECCENTRIC FITTINGS
UNION
SHUT-OFF VALVE, SEE SPECS
ANGLE VALVE
RELIEF VALVE
VALVE WITH OUTSIDE STEM & YOKE
TWO-WAY CONTROL VALVE
THREE-WAY CONTROL VALVE
SOLENOID TWO-WAY CONTROL VALVE
FLOW SWITCH
PRESSURE SWITCH
AQUASTAT
ORIFICE FLOW METER
VENTURI FLOW METER / FLOW MEASURING STATION
STRAINER WITH CAPPED BLOWDOWN
MANUAL AIR VENT
AUTOMATIC AIR VENT
VACUUM BREAKER
THERMOMETER
PRESSURE GAUGE
INLINE PUMP
DIFFERENTIAL PRESSURE TRANSMITTER
WATER HAMMER ARRESTER WITH SCHEDULE TYPE
P-TRAP AND RISER
FLOOR DRAIN WITH SIZE & SCHEDULE TYPE
END OF PIPE CLEANOUT
FLOOR CLEANOUT
WALL CLEANOUT
EXTERIOR CLEANOUT OR RODDING HOLE
THERMOSTATIC MIXING VALVE WITH SCHEDULE TYPE
HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE
WATER METER
GAS METER
ROOF DRAIN, OVERFLOW DRAIN WITH SIZE
POST INDICATOR VALVE
FIRE DEPARTMENT CONNECTION
VALVE TAMPER SWITCH
UPRIGHT SPRINKLER HEAD
PENDANT SPRINKLER HEAD
DRY PENDANT SPRINKLER HEAD
CONCEALED SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
RECTANGULAR DUCTWORK
DESIGNATION IN INCHES, FIRST
DIMENSION IS SIDE SHOWN
ROUND SPIRAL DUCTWORK
DESIGNATION IN INCHES
FLAT OVAL DUCTWORK
DESIGNATION IN INCHES, FIRST
DIMENSION IS SIDE SHOWN
RECTANGULAR SUPPLY AIR,
OUTSIDE AIR DUCTWORK RISE
ROUND SPIRAL SUPPLY AIR,
OUTSIDE AIR DUCTWORK RISE
FLAT OVAL SUPPLY AIR,
OUTSIDE AIR DUCTWORK RISE
RECTANGULAR SUPPLY AIR,
OUTSIDE AIR DUCTWORK DROP
ROUND SPIRAL SUPPLY AIR,
OUTSIDE AIR DUCTWORK DROP
FLAT OVAL SUPPLY AIR,
OUTSIDE AIR DUCTWORK DROP
RECTANGULAR RETURN AIR,
TRANSFER AIR DUCTWORK RISE
ROUND SPIRAL RETURN AIR,
TRANSFER AIR DUCTWORK RISE
FLAT OVAL RETURN AIR,
TRANSFER AIR DUCTWORK RISE
RECTANGULAR RETURN AIR,
TRANSFER AIR DUCTWORK DROP
ROUND SPIRAL RETURN AIR,
TRANSFER AIR DUCTWORK DROP
FLAT OVAL RETURN AIR,
TRANSFER AIR DUCTWORK DROP
RECTANGULAR EXHAUST AIR,
RELIEF AIR DUCTWORK RISE
ROUND SPIRAL EXHAUST AIR,
RELIEF AIR DUCTWORK RISE
FLAT OVAL EXHAUST AIR, RELIEF
AIR DUCTWORK RISE
RECTANGULAR EXHAUST AIR,
RELIEF AIR DUCTWORK DROP
ROUND SPIRAL EXHAUST AIR,
RELIEF AIR DUCTWORK DROP
FLAT OVAL EXHAUST AIR, RELIEF
AIR DUCTWORK DROP
DUCTWORK CONSTRUCTED OF
ALUMINUM, STAINLESS STEEL
DUCTWORK RISE IN DIRECTION
OF FLOW
DUCTWORK DROP IN DIRECTION
OF FLOW
SUPPLY AIR, OUTSIDE AIR IN
DIRECTION OF FLOW
RETURN AIR, EXHAUST AIR,
TRANSFER AIR, RELIEF AIR IN
DIRECTION OF FLOW
ECCENTRIC DUCT TRANSITION CONCENTRIC DUCT TRANSITION RECTANGULAR TO ROUND, FLAT
OVAL DUCT TRANSITION
BALANCE OR VOLUME DAMPER ACCESS DOOR DUCTWORK CAP
45° BEVELED FITTING FOR
RECTANGULAR TO
RECTANGULAR DUCTWORK
RADIUS DUCTWORK ELBOW
(CENTERLINE RADIUS 1.5xW)SOUND ATTENUATOR
CONICAL FITTING FOR ROUND
OR FLAT OVAL TO
RECTANGULAR DUCTWORK
RADIUS DUCTWORK ELBOW
WITH TURNING VANES MITERED DUCTWORK ELBOW
CONICAL FITTING FOR ROUND
OR FLAT OVAL TO ROUND OR
FLAT OVAL DUCTWORK
WYE RADIUS DUCTWORK ELBOW MITERED DUCTWORK ELBOW
WITH TURNING VANES
45° LATERAL FITTING FOR ROUND
OR FLAT OVAL TO ROUND OR
FLAT OVAL DUCTWORK
45° RADIUS DUCTWORK ELBOW
(CENTERLINE RADIUS 1.5xW)
TRANSFER AIR ELBOW WITH
DUCTWORK STUBS FOR SOUND
ATTENUATION
SPIN-IN FITTING FOR ROUND TO
RECTANGULAR DUCTWORK,
LOW PRESSURE DUCTWORK
CEILING PANEL SUPPLY AIR
DIFFUSER ROUND SUPPLY AIR DIFFUSER
FLEXIBLE DUCTWORK
CONNECTION TO DIFFUSER,
MAXIMUM SIX FEET
RECTANGULAR SUPPLY AIR
REGISTER OR GRILLE
RETURN AIR, TRANSFER AIR
REGISTER OR GRILLE
EXHAUST AIR REGISTER OR
GRILLE
LINEAR SLOT SUPPLY AIR
DIFFUSER
SIDEWALL SUPPLY AIR
REGISTER OR GRILLE
SIDEWALL RETURN AIR,
EXHAUST AIR, TRANSFER AIR
REGISTER OR GRILLE
DOOR GRILLE OR UNDERCUT
DOOR
THERMOSTAT WITH ASSOCIATED
EQUIPMENT DESIGNATION TEMPERATURE SENSOR CEILING DESTRATIFICATION FAN
HUMIDISTAT WITH ASSOCIATED
EQUIPMENT DESIGNATION
CARBON DIOXIDE OR MONOXIDE
SENSOR
CENTRIFUGAL ROOF EXHAUST
FAN
HYDRONIC REHEAT COIL WITH
ACCESS DOOR SINGLE DUCT VAV BOX INLINE FAN
ELECTRIC REHEAT COIL WITH
ACCESS DOOR
SERIES/PARALLEL FAN
POWERED TERMINAL UNIT
BASE MOUNTED PUMP UNIT HEATER
SECTION INDICATOR:REFERENCE SECTION LOCATION THROUGH AN AREA FOR
ADDITIONAL INFORMATION.
PLAN NOTE INDICATOR:REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL
INFORMATION.
DETAIL INDICATOR:REFERENCE DETAIL LOCATION FOR ADDITIONAL
INFORMATION.
DRAWING BLOCK TITLE
INDICATOR:
REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL
INFORMATION.
MATCH LINE INDICATOR:REFERENCE SHEET LOCATION FOR ADDITIONAL
INFORMATION.
REVISION INDICATOR:REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL
INFORMATION.
EQUIPMENT INDICATOR:REFERENCE SCHEDULE LOCATION FOR ADDITIONAL
INFORMATION.
DIFFUSER, GRILLE,
REGISTER INDICATOR:
REFERENCE SCHEDULE LOCATION FOR ADDITIONAL
INFORMATION.
MAKE UP WATER
AIR RELIEF VENT
HEATING WATER SUPPLY
HEATING WATER RETURN
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
REFRIGERANT LIQUID
REFRIGERANT HOT GAS
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
LINETYPE DESIGNATORS
THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS.
INTERMEDIATE DASHED LINETYPE INDICATE ITEMS TO BE REMOVED
ON COMBINATION PLANS.
INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE WORK TO
BE INCLUDED.
THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE.
INDICATES POINT OF CONNECTION TO EXISTING EQUIPMENT, PIPING
OR MATERIALS.
INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT,
PIPING OR MATERIALS.
SHEET TYPE DESIGNATORS
000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES)
100 PLANS
200 PLANS (SECONDARY)
300 ENLARGED PLANS & SECTIONS
400 SCHEMATICS & DIAGRAMS
500 SCHEDULES
600 DETAILS
700 CONTROL DIAGRAMS
800 (USER DEFINED)
900 3D REPRESENTATIONS (ISOMETRICS)
NOTATION DESIGNATORS
GENERAL MECHANICAL
NOTES:
NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE
DISCIPLINE.
GENERAL SHEET
NOTES:
NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH
THEY APPEAR.
SHEET PLAN NOTES:NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH
THEY APPEAR AND USE A PLAN NOTE INDICATOR TO IDENTIFY
ITEMS.
∅DIAMETER, PHASE ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE (°F)
°F DEGREES FAHRENHEIT EW EMERGENCY EYEWASH OBD OPPOSED BLADE DAMPER
A/C AIR CONDITIONING EWC ELECTRIC WATER COOLER OD OUTSIDE DIAMETER, OVERFLOW DRAIN
AAV AIR ADMITTANCE VALVE EWT ENTERING WATER TEMPERATURE (°F)OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
ACC AIR COOLED CONDENSER EXH EXHAUST OFD OVERFLOW ROOF DRAIN
ACCU AIR COOLED CONDENSING UNIT EXIST/EX EXISTING OSD OPEN SITE DRAIN
AD AREA DRAIN, ACCESS DOOR F FURNACE OZ OUNCE
AFF ABOVE FINISHED FLOOR F&T FLOAT AND THERMOSTATIC STEAM TRAP P PUMP
AFG ABOVE FINISHED GRADE FCO FLOOR CLEANOUT PBD PARALLEL BLADE DAMPER
AFMS AIR FLOW MEASURING STATION FCU FAN COIL UNIT PC PLUMBING CONTRACTOR
AFUE ANNUAL FUEL UTILIZATION EFFICIENCY FD FLOOR DRAIN, FIRE DAMPER PD PRESSURE DROP
AGA AMERICAN GAS ASSOCIATION FDC FIRE DEPARTMENT CONNECTION PE PNEUMATIC ELECTRIC
AHU AIR HANDLING UNIT FDTN FOUNDATION PH PHASE
AL ACOUSTICALLY LINED, ALUMINUM FE FIRE EXTINGUISHER PIV POST INDICATOR VALVE
AMB AMBIENT FHC FIRE HOSE CABINET PPM PARTS PER MILLION
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE FLR FLOOR PRV PRESSURE REDUCING VALVE
AO ANALOG OUTPUT FM FACTORY MUTUAL PSI POUNDS PER SQUARE INCH
AP ACID PROOF, ACCESS PANEL FPM FEET PER MINUTE PSIG POUNDS PER SQUARE INCH GAUGE
APD AIR PRESSURE DROP (IN. WC.)FPVAV FAN POWERED VAV UNIT PTAC PACKAGED TERMINAL AIR CONDITIONER
ARCH ARCHITECT FS FLOOR SINK PVC POLYVINYL CHLORIDE
ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE FSC FIRE SUPPRESSION CONTRACTOR R REGISTER, REFRIGERANT
ARV AIR RELIEF VALVE FSD COMBINATION FIRE/SMOKE DAMPER RA RETURN AIR
AS AIR SEPARATOR FT FOOT, FEET RAD RADIATION
ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING FTG FOOTING RAT RETURN AIR TEMPERATURE (°F)
AND AIR CONDITIONING ENGINEERS FTR FINNED TUBE RADIATION RCP REINFORCED CONCRETE PIPE
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS G NATURAL GAS RD ROOF DRAIN
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS GA GAGE OR GAUGE REV REVOLUTIONS
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS GAL GALLON RF RETURN FAN
ATM ATMOSPHERE GC GENERAL CONTRACTOR RG RETURN GRILLE
AUTO AUTOMATIC GIV GRAVITY INTAKE VENTILATOR RH RELATIVE HUMIDITY, ROOF HYDRANT
AV AUTOMATIC VENT GPD GALLONS PER DAY RM ROOM
AVG AVERAGE GPH GALLONS PER HOUR RP RADIANT PANEL
AVS ACID VENT STACK GPM GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE
AW ACID WASTE GR GRILLE, GRAINS RPS REVOLUTIONS PER SECOND
AWWA AMERICAN WATER WORKS ASSOCIATION GRV GRAVITY RELIEF VENTILATOR RTU ROOF TOP UNIT
BD BUTTERFLY DAMPER GT GREASE TRAP RV RELIEF VALVE, ROOF VENT
BDD BACKDRAFT DAMPER HB HOSE BIBB SA SUPPLY AIR
BE BOTTOM ELEVATION HD HEAD (FT.)SAN SANITARY
BHP BRAKE HORSEPOWER Hg MERCURY SD SUPPLY DIFFUSER, SMOKE DAMPER
BLDG BUILDING HWP HEATING HOT WATER PUMP SEER SEASONAL ENERGY EFFICIENCY RATIO
BOD BOTTOM OF DUCT HO HUB OUTLET SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR
BOP BOTTOM OF PIPING HORIZ HORIZONTAL SG SUPPLY GRILLE
BSMT BASEMENT HP HORSEPOWER, HEAT PUMP SU SHOWER UNIT
BT BATHTUB HR HOUR(S)SK SINK
BTM BOTTOM HRTU HEATING ONLY ROOFTOP UNIT SMACNA SHEET METAL AND AIR CONDITIONING
BtuH BRITISH THERMAL UNIT PER HOUR HRV HEAT RECOVERY VENTILATOR CONTRACTORS NATIONAL ASSOCIATION
CA COMPRESSED AIR HX HEAT EXCHANGER SP STATIC PRESSURE
CAV CONSTANT AIR VOLUME Hz HERTZ SPEC SPECIFICATION
CB CATCH BASIN IB INVERTED BUCKET STEAM TRAP SQ SQUARE
CCW COUNTERCLOCKWISE ID INSIDE DIAMETER SR SUPPLY REGISTER
CD CONDENSATE DRAIN IN INCH, INCHES SRV SAFETY RELIEF VALVE
CO₂CARBON DIOXIDE INT INTERIOR SS SERVICE SINK, STAINLESS STEEL
CFM CUBIC FEET PER MINUTE INV EL INVERT ELEVATION STD STANDARD
CH CHILLER IPS INTERNATIONAL PIPE STANDARD SV STEAM VENT
CHP CHILLED WATER PUMP IW INDIRECT WASTE TCC TEMPERATURE CONTROL CONTRACTOR
CI CAST IRON KEC KITCHEN EQUIPMENT CONTRACTOR TCP TEMPERATURE CONTROL PANEL
CMP CORRUGATED METAL PIPE kW KILOWATT TD TEMPERATURE DIFFERENCE
CO CLEANOUT / CARBON MONOXIDE LAB LABORATORY TE TOP ELEVATION
COMPR COMPRESSOR LAT LEAVING AIR TEMPERATURE (°F)TEMP TEMPERATURE
COND CONDENSER L LAVATORY TF TRANSFER FAN
CONV CONVECTOR LBS POUNDS TG TRANSFER GRILLE
CP CONDENSATE PUMP LD LINEAR DIFFUSER TMV THERMOSTATIC MIXING VALVE
CPVC CHLORINATED POLYVINYL CHLORIDE LP LIQUID PETROLEUM TONS TONS OF REFRIGERATION
CT COOLING TOWER LTG LIGHTING TP TRAP PRIMER
CU CONDENSING UNIT LWT LEAVING WATER TEMPERATURE (°F)TRANS TRANSITION
CUH CABINET UNIT HEATER MA MIXED AIR TS TAMPER SWITCH, TUB SHOWER
CUV CLASSROOM UNIT VENTILATOR MAT MIXED AIR TEMPERATURE (°F)TSP TOTAL STATIC PRESSURE (IN. WC.)
CV CONTROL VALVE MAX MAXIMUM TXV THERMAL EXPANSION VALVE
CW CLOCKWISE MB MOP BASIN TYP TYPICAL
CWP CONDENSER WATER PUMP MBH THOUSAND Btu PER HOUR UC UNDERCUT DOOR
dB DECIBEL MC MECHANICAL CONTRACTOR UH UNIT HEATER
DB DRY BULB MCA MINIMUM CIRCUIT AMPS UL UNDERWRITERS LABORATORIES
DF DRINKING FOUNTAIN MCC MOTOR CONTROL CENTER UNO UNLESS NOTED OTHERWISE
DG DOOR GRILLE MD MOTORIZED DAMPER UR URINAL
DH DUCT HEATER MFR MANUFACTURER UV UNIT VENTILATOR, ULTRAVIOLET
DI DIGITAL INPUT, DISTILLED WATER MH MANHOLE V VOLTS, VENT
DIA DIAMETER MIN MINIMUM VAC VACUUM
DN DOWN MISC MISCELLANEOUS VAV VARIABLE AIR VOLUME
DO DIGITAL OUTPUT MS MOP SINK VB VACUUM BREAKER
DS DOWNSPOUT, DOWN STREAM MTD MOUNTED VD VOLUME DAMPER
DWG DRAWING MV MANUAL VENT VEL VELOCITY
DWH DOMESTIC WATER HEATER N NITROGEN VERT VERTICAL
DWV DRAIN, WASTE & VENT NA NOT APPLICABLE VF VENTILATION FAN
DX DIRECT EXPANSION NC NOISE CRITERIA, NORMALLY CLOSED VFD VARIABLE FREQUENCY DRIVE
EA EXHAUST AIR NEC NATIONAL ELECTRIC CODE VTR VENT THROUGH ROOF
EAT ENTERING AIR TEMPERATURE (°F)NFC NATIONAL FIRE CODE W WASTE, WATT
EC ELECTRICAL CONTRACTOR NFPA NATIONAL FIRE PROTECTION ASSOCIATION WC WATER COLUMN
ECO EXTERIOR CLEANOUT NFWH NON-FREEZE WALL HYDRANT WB WET BULB
EDR EQUIVALENT DIRECT RADIATION NIC NOT IN CONTRACT WC WATER CLOSET
EER ENERGY EFFICIENCY RATIO NO NORMALLY OPEN, NITROUS OXIDE WCO WALL CLEANOUT
EF EXHAUST FAN NOM NOMINAL WH WALL HYDRANT
EFF EFFICIENCY NPW NON-POTABLE WATER WPD WATER PRESSURE DROP (FT. HD.)
EG EXHAUST GRILLE NTS NOT TO SCALE WSHP WATER SOURCE HEAT PUMP
EL ELEVATION O OXYGEN YD YARD DRAIN
EOM END OF MAIN DRIP OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
ES EMERGENCY SHOWER
ESP EXTERNAL STATIC PRESSURE (IN. WG.)
DISCIPLINE DESIGNATORS
M-000 MECHANICAL
FP000 FIRE SUPPRESSION
P-000 PLUMBING
PD000 PLUMBING DEMOLITION
H-000 HVAC
HD000 HVAC DEMOLITION
HP000 HVAC PIPING
PIPING IDENTITY SYMBOLS HVAC IDENTITY SYMBOLS
REFERENCE SYMBOLSPIPING LINE SYMBOLS
ABBREVIATIONS AND TERMS GENERAL MECHANICAL NOTES
X
X
SECTION LOCATION
IN DRAWING MODULE
SECTION LOCATION AT SUBSET SHEET
DETAIL LOCATION IN
DRAWING MODULE
DETAIL LOCATION AT
SUBSET SHEET
LARGE SCALE VIEW LOCATION
IN DRAWING MODULE
LARGE SCALE VIEW LOCATION
AT SUBSET SHEET
PLAN NOTE INDICATORS
EQUIPMENT TYPE
NUMERIC CHARACTER RELATES TO ITEM
ALPHANUMERIC CHARACTER RELATES
TO ASSOCIATED AIR HANDLER (OPTIONAL)
AREA LEADER
LINE LEADER
POINT LEADER
DRAWING MODULE LOCATION
(IDENTIFYING LOWER LEFT OF MULTIPLE MODULES)
REVISION CLOUD
REVISION INDICATOR
GRAPHIC SCALENUMERIC SCALE
SEE XXX
REFER TO ADDITIONAL
SHEET FOR CONTINUATION
FLOOR PLAN OVERLAP BEYOND AREA
EXTENSION
PLAN
PLAN
NUMERIC CHARACTER
RELATES TO ITEM
NORTH ARROW
BEYOND AREA
EXTENSION
ALPHANUMERIC CHARACTER RELATES
TO BUILDING LEVEL (OPTIONAL)
DRAWING TITLE
1/8" = 1'-0"X
X X
SHEET PLAN NOTES
1.
AIRFLOW (CUBIC
FEET PER MINUTE)
NECK SIZE
SCHEDULE TYPE
AIRFLOW (CUBIC
FEET PER MINUTE)
SIZE
SCHEDULE TYPE
AIRFLOW (CUBIC
FEET PER MINUTE)
NO. OF SLOTS
-LENGTH
SCHEDULE TYPE
DIFFUSER REGISTER/GRILLE SLOT/LINEAR DIFFUSER
SA
R DALSS
AD
CO
M
G
CO
4"RD 4"OFD
24/12 24ø 24/12 FO
NO
N
O
MV
MA
GV
LP
G
F
DE
HWR 140
HW 140
PD
D
AV
AW
USD
ST
RHG
CD
RL
CHR
CHS
CR
CS
RS
RD
HR
HS
ARV
MU
FM
SG
IW
A
(TU-12.34)
(TU-12.34)
CO2
NPW
FD
HB-1 WH-1
FCO
2"FD-1
WCO
ECO
TMV-1
WHA-A
NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTW
SCW
X X
X X X
X X X
X
1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BIDDING AND BEFORE
BEGINNING WORK.
2. REVIEW WORK OF OTHER TRADES. COORDINATE AND PLAN WORK WITH THE
OTHER TRADES. ADJUST AS A RESULT OF COORDINATION. REVIEW
COORDINATED EFFORTS WITH ENGINEER FOR APPROVAL.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION
OF ALL CEILING MOUNTED ITEMS. THE ENGINEERING DRAWINGS ARE OF EQUAL
IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF
THE CONTRACT DOCUMENTS. SHOULD THERE BE A DISCREPANCY BETWEEN
THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THE
DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS
ATTENTION FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THE
ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR.
4. STORE EQUIPMENT AND COMPONENTS IN A CLEAN, DRY LOCATION UNTIL
READY FOR INSTALLATION. PROTECT FROM WEATHER, THEFT, DIRT, FUMES,
WATER, CONSTRUCTION DEBRIS, ETC. AT ALL TIMES. ANY DAMAGED
EQUIPMENT OR COMPONENT SHALL BE RESTORED AS NEW OR REPLACED.
5. MECHANICAL DRAWINGS SHOW THE INTENDED ARRANGEMENT AND ROUTING
OF ALL PIPING, DUCTWORK, EQUIPMENT AND APPURTENANCES. THEY SHALL BE
FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND WORK OF
OTHER TRADES WILL PERMIT. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR
APPURTENANCES SHALL BE PROVIDED AS REQUIRED.
6. PERFORM ALL WORK IN A SKILLED, PROFESSIONAL MANNER MEETING THE
ACCEPTANCE OF THE ENGINEER, ARCHITECT AND OWNER.
7. LABEL ALL ROOM THERMOSTATS AND/OR SENSOR DEVICES AS TO WHAT THE
DEVICE CONTROLS WITH A PLASTIC ENGRAVED LABEL AFFIXED TO THE
COVERS.
8. SMALLEST HVAC PIPE SIZE ALLOWABLE IS 3/4" UNLESS NOTED OTHERWISE.
9. MOUNTING HEIGHTS OF DEVICES SHALL FOLLOW THE LISTING BELOW UNLESS
SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS:THERMOSTAT
OR TEMPERATURE/HUMIDITY SENSOR... +46" TO TOP
10. PAINT PIPING IN MECHANICAL ROOMS. REFER TO SPECIFICATIONS FOR COLOR
CODING. PREPAINT ALL STEEL CHILLED WATER PIPING PRIOR TO INSULATING.
11. CLEAN ALL EQUIPMENT TO PRESENT A 'LIKE NEW' CONDITION AT PROJECT
COMPLETION. VACUUM CLEAN INTERNAL AREAS OF EQUIPMENT AND PANELS.
12. CLEAN ALL MECHANICAL AND ELECTRICAL AREAS AND ROOMS OF DEBRIS AND
UNUSED MATERIALS. VACUUM FLOORS.
13. OFFSET PIPING AND DUCTWORK AROUND ELECTRICAL PANELS TO PROVIDE
CLEARANCES AS REQUIRED BY NATIONAL ELECTRICAL CODE.
14. REFERENCE THE ARCHITECTURAL ELEVATIONS FOR LOCATIONS OF ALL
MECHANICAL ITEMS INTERFACING OR ARE WITHIN THE EXTERIOR WALLS. (I.E.
WALL HYDRANTS, LOUVERS, ETC.).
15. DEMOLITION/REMODEL
A. ALL MATERIALS REMOVED AND NOT RELOCATED BECOME THE PROPERTY
OF THE CONTRACTOR. REMOVE MATERIALS FROM THE PROJECT SITE
UNLESS NOTED OTHERWISE. OWNER HAS THE OPTION TO REVIEW ITEMS
PRIOR TO REMOVAL AND RETAIN IF DESIRED.
B. PATCH WALLS, FLOORS, CEILINGS, COLUMNS, ROOF PENETRATIONS, ETC.
WHERE ITEMS ARE REMOVED TO MATCH FINISH OF ADJACENT SURFACES.
C. RELOCATE EXISTING ITEMS AS REQUIRED FOR INSTALLATION OF WALLS,
CEILINGS, DUCTWORK AND PIPING EQUIPMENT.
D. REMOVE ALL PIPING, DUCTWORK, CONTROLS, SUPPORTS, ETC.
MADEUNNECESSARY OR OBSOLETE AS A RESULT OF THIS PROJECT.
E. ALL ITEMS WITH NOTATION 'EX' ARE TO REMAIN.
F. ALL ITEMS WITH NOTATION 'R' ARE RELOCATED, AS NOTED.
16. VERIFY DIMENSIONS GIVEN IN THE ARCHITECTS PLANS FOR EXACT LOCATIONS.
IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED
FOR CLARIFICATION. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER
SCALE.
17. REFER TO MANUFACTURER'S INSTALLATION AND TEMPLATE DRAWINGS FOR
ALL MECHANICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES,
ISOLATORS, SPRING ISOLATION, ETC.
18. BRANCH DUCTWORK TO DIFFUSER SHALL BE SAME SIZE AS DIFFUSER INLET
UNLESS SPECIFICALLY LABELED OTHERWISE.
FSAFMS
FLEXIBLE DUCTWORK
CONNECTION
MOTORIZED DAMPER WITH
ACCESS DOOR
FIRE DAMPER WITH ACCESS
DOOR
SMOKE DAMPER WITH ACCESS
DOOR
AIRFLOW MEASURING STATION
WITH ACCESS DOOR
FIRE AND SMOKE DAMPER WITH
ACCESS DOOR
M F S
18166
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS800 West Monon Green Blvd.M-000
MECHANICAL
SYMBOLS, LEGENDS &
ABBREVIATIONS
08/31/202108/31/2021
THOMAS KENNEDY JOE BOLYARD
11700201
No.
STATE OFJOSEPHR.BO
L
Y
ARDPROFE
S
S
IONA L E N G INEERDATE SIGNED 08/31/21REGISTER
E
D
I
ND I A N A