HomeMy WebLinkAboutP-104 - 4TH FLOOR PLUMBING PLANSEE 1/ P-301 FOR ENLARGED UNIT PLAN SEE 3/ P-301 FOR ENLARGED UNIT PLAN SEE 2/ P-302 FOR ENLARGED UNIT PLAN SEE 4/ P-301 FOR ENLARGED UNIT PLAN SEE 1/ P-302 FOR ENLARGED UNIT PLAN SEE 4/ P-302 FOR ENLARGED UNIT PLAN SEE 4/ P-302 FOR ENLARGED UNIT PLAN SEE 3/ P-301 FOR ENLARGED UNIT PLAN 1 25 1 2 5 1 2 5 1 2 5 3 1 2 4 4 4 4 4 4 4 4 4 6" ST6" ST 6" ST 6" ST 6" ST 6 6 6 7 7 6 6 10 SEE 3/ P-302 FOR ENLARGED UNIT PLAN 4 SEE 2/ P-301 FOR ENLARGED UNIT PLAN 6 6 MB-1 8 9 11 3/4" CW GENERAL PLUMBING NOTES: A. REFERENCE SHEET M-000 FOR PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS AND ADDITIONAL GENERAL NOTES. 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S IONA L E N G INEERDATE SIGNED 08/31/21 R E G I S T ER E D I ND I A N A 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS GRJK800 West Monon Green Blvd.P-104 4TH FLOOR PLUMBING PLAN 08/31/202108/31/2021 1/8" = 1'-0" 4TH FLOOR PLUMBING PLAN1016'8'4' N SHEET PLAN NOTES 1 4"ST UP TO ROOF DRAIN. 2 4"ST UP TO OVERFLOW DRAIN. 3 6"ST DOWN IN CHASE. 4 4" WASTE AND 4" VENT STACK. 4"V UP. 4" VENT THRU ROOF. 5 6"ST DOWN IN CORNER OF ROOM. 6 1 1/4"CW FROM BELOW FLOOR SLAB IN WALL. 7 1 1/2"CW FROM BELOW FLOOR SLAB IN WALL. 8 3/4"CW AND 3/4"HW FROM BELOW. 9 3" WASTE/VENT STACK. 10 1 1/4"CW FROM BELOW FLOOR SLAB IN WALL. 3/4"CW RISE. 11 3/4"CW UP TO ROOF HYDRANT.