HomeMy WebLinkAboutA0003 YDDUMPSTERD
DA
B
CE
3 YDDUMPSTER
CO2OIL TANK36"X72"POS/ RESETPOS
HOST30x48
30x48
30x48
POS/ RESET
RESET
EP
EP
COOLER
COOLER
HOOD
COVER SHEET
A000
SOCIAL CANTINA
RAILYARD AT MIDTOWN
350 MONON BLVD., SUITE 10
CARMEL, IN 46032
DRAWING INDEX
INTERIOR DESIGN:
PHANOMEN/ design
934 FT. Wayne Ave.
Indianapolis, IN 46202
(317) 439-4355
LOREE O. EVERETTE
TENANT:
FINNEY HOSPITALITY
101 N. College Ave.
Bloomington, IN 47404
(317) 378-7274
NATHAN FINNEY
PROJECT TEAM
COURTESY OF GOOGLEPROJECT LOCATION
BUILDING CODE:
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE: 675 IAC 13-2.6)
PLUMBING CODE:
2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE: 675 IAC 16-1.4)
ELECTRICAL CODE:
2009 INDIANA ELECTRICAL CODE (2008 NFPA-70: 675 IAC 17-1.8)
MECHANICAL CODE:
2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL
CODE: 675 IAC 18-1.6)
FIRE / LIFE SAFETY CODE:
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE: 675 IAC 22-2.5)
ACCESSIBILITY CODE:
2008 INDIANA BUILDING CODE CHAPER 11 - ACCESSIBILITY (675 IAC 13-2.5-12 CHAPTER 11)
ENERGY CODE:
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1, 2007 EDITION: 675 IAC 19-4)
ELEVATOR CODE:
2011 INDIANA ELEVATOR SAFETY CODE (ANSI/ASME A17.1, 2007 EDITION: 675 IAC 21-3)
GAS CODE:
2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE: 675 IAC 25-3)
APPLICABLE CODES
KITCHEN CONSULTANT:
C & T DESIGN AND EQUIPMENT CO.
2750 Tobey DR.
Indianapolis, IN 46219
(317) 644-7833
CHRIS MONICO
NO SCALESCALE: N.T.S.
LOCATION PLAN
A000
1
N
S
W E
PROJECT
LOCATION
GENERAL CONTRACTOR:
MEYER-NAJEM CONSTRUCTION
11787 Lantern Rd. Suite 100
Fishers, IN 46038
(317)577-0007
MAYNARD SOUKUP
NICK GEIGER
SCALE: N.T.S.
VICINITY MAP
A000
2 N
S
W E
Certified By:Scale:Date:Checked By:Drawn By:Revisions:
Job Number:
Drawing Number:
Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032GENERAL FIRE PROTECTION NOTES
RENOVATED AREAS SHALL BE 100% SPRINKLERED.A.
COORDINATE CLOSELY WITH OTHER TRADES. REFER TO ARCHITECTURAL DRAWINGS
FOR CEILING TYPES.B.
ALL SPRINKLER WORK SHALL BE INSTALLED PER NFPA 13, BUILDING CODE, AND
OWNER'S INSURANCE CARRIER REQUIREMENTS.
C.
MAKE PROVISIONS FOR THE DRAINING AND PROVIDE INSPECTOR TESTS AS
REQUIRED, ALL DRAIN PIPING SHALL BE PIPED TO OUTSIDE OR INDIRECTLY TO SINK
OR FLOOR DRAIN.
D.
COORDINATE EXACT LOCATION OF PIPING AND HEADS WITH REFLECTED CEILING
PLANS, MECHANICAL AND ELECTRICAL DRAWINGS.E.
ALL HOSE VALVES AND FIRE DEPARTMENT CONNECTIONS SHALL MATCH LOCAL
FIRE DEPARTMENT THREADS.
F.
ALL FIRE SUPPRESSION WORK SHALL BE PERFORMED BY A FIRE PROTECTION
CONTRACTOR LICENSED IN THE STATE OF OHIO.
G.
ALL SPRINKLER HEADS SHALL BE LOCATED IN CENTER OF CEILING TILE IN AT LEAST
ONE DIRECTION.
H.
SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING
FOR SPRINKLER WORK IN ALL AREAS OF BUILDING. REFER TO SPECIFICATIONS.
I.
ALL ARMOVER PIPING RELATED TO SPRINKLERS TO BE DEMOLISHED ARE TO
REMOVED BACK TO THE OUTLET ON THE BRANCHLINE.
J.
WHEN MODIFYING EXISTING SPRINKLER SYSTEMS, SPRINKLER CONTRACTOR SHALL
MAINTAIN THE INTEGRITY OF THE EXISTING SPRINKLER ZONES. COORDINATE WITH
NEW FIRE RATING PLANS IF APPLICABLE.
K.
FIRE PROTECTION CONTRACTOR IS REQUIRED TO RAISE/REWORK ALL EXISTING
PIPING AS NEEDED TO ACCOMMODATE NEW CEILINGS AND HIGHER CEILING
HEIGHTS AS APPLICABLE.
L.
ELECTRICIAN:
DESIGN AND BUILD ELECTRICAL
(317) 782-1887
DANIEL KIDWELL
PLUMBING:
FERRER MECHANICAL
2801 Fortune Circle East, Suite F.,
Indianapolis, IN 46241
(317) 757-2019
Rick Jordan
MECHANICAL
SWIFT AIR MECHANICAL, INC.
(317)547-5355
RANDY SMILEY
ALAN COX
LOW VOLTAGE & AV:
EXPERIENCE TECHNOLOGIES
(812)323- 9533
ERIC STIENING
PERGOLA:
THE SMART PERGOLA
12958 Brighton Ave.
Carmel, IN 46032
(317) 682-4072
CLAUDIO BERTOLINI
LANDLORD:
BARRETT & STOKLEY, INC.
3755 E. 82nd Street
Indianapolis, IN 46240
(317) 845-4171
THOMAS E. MARIANI
Social Cantina
Drawing Index PermitSet07/30/2021X - Included without Revisions
O - Included with Revisions
General
A000 Cover Sheet X
A001 General Notes X
A002 Life Safety Plan X
X
Architectural
A010 Architectural Wall Types X
A100 Architectural Floor Plan & Door Schedule X
A102 Enlarged Restroom Plan, Elevations, & Notes X
A103 Ramp Plan and Details X
A200 Interior Elevations X
A201 Interior Elevations X
A202 Interior Elevations X
A203 Interior Elevations X
A205 Interior Sections X
A400 Reflected Ceiling Plan X
A401 Dimensioned Reflected Ceiling Plan & Details X
A701 Finish Floor Plan X
A800 Furniture Plan X
Mechanical
M100 HVAC Plan X
M200 HVAC Schedules X
Electrical
E101 X
E102 Electrical Schedules and Details X
E103 Electrical Schedules and Details X
E201 North Floor Plan - Lighting X
E202 South Floor Plan - Lighting X
E301 Floor Plan - Power X
E302 Enlarged Kitchen Plan - Power X
E401 Floor Plan - Fire Alarm X
E501 Floor Plan - HVAC Connections X
Plumbing
P000 Plumbing General Information X
P001 Plumbing Detail and Schedules X
P002 Plumbing Schedules X
P003 Plumbing Specifications X
P100 Underground Plumbing Plan X
P101 First Floor Vent and Natural Gas Floor Plan X
P102 First Floor Domestic Water Plan X
P103 Sanitary Waste and Vent Riser Diagram X
09/23/21