HomeMy WebLinkAboutA01020 GA - 3 5/8" METAL STUDS @ 16" O.C.
SCHEDULED
CEILING SYSTEM
3 5/8" METAL RUNNER
BRACE TO STRUCTURE
ABOVE AS REQUIRED (TYP) DECK
3-1/2" R11 UNFACED
INSULATION IN STUD CAVITIES
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCALE: 1/2"=1'-0"
WT-1 WALL TYPE1
SCHEDULED BASE
SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLANVARIESSEE REFLECTED CEILING PLAN5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 3 5/8" METAL STUDS @ 16" O.C.
SCHEDULED
CEILING SYSTEM
3 5/8" METAL RUNNER
SCALE: 1/2"=1'-0"
WT-3 WALL TYPE3 CONFIRM WITHKITCHEN SUPPLIER5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 6" METAL STUDS @ 16" O.C.
3 5/8" METAL RUNNER
(BRACE AS REQUIRED)
STAINLESS STEEL PASS THROUGH
WINDOW BY KITCHEN EQUIPMENT
VENDOR
SCALE: 1/2"=1'-0"
WT-4 WALL TYPE4
WT-1A - WALL TYPE AS SHOWN
WT-1B - WALL TYPE WITHOUT INSULATION
SCALE: 1/2"=1'-0"
WT-2 WALL TYPE2
WT-2A - WALL TYPE AS SHOWN
WT-2B - WALL TYPE WITHOUT INSULATION 1/2" = 1'-0"ARCHITECTURAL
WALL TYPES
A010CONFIRM FINAL HEIGHT WITHCOUNTERTOPINSTALLATION PRIORTO ROUGH IN5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
18 GA - 6" METAL STUDS @ 16" O.C.
6" METAL RUNNER
(BRACE AS REQUIRED)
COUNTERTOP. REFER TO
INTERIOR SECTIONS/ELEVATIONS
FOR FINAL DESIGN
WOOD BLOCKING AS REQUIRED
GENERAL WALL TYPE NOTES
1. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT TOILET ROOMS, KITCHENS, JANITORS CLOSETS,
SINKS, OTHER SIMILAR LOCATIONS, AND ANY WALL WHICH IS TO RECEIVE A TILE FINISH. IF TWO LAYERS OF
GYPSUM BOARD ARE INDICATED IN A WALL ASSEMBLY ONLY THE OUTSIDE LAYER NEED BE REPLACED WITH
CEMENT BOARD.
2. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT KITCHEN AND SIMILAR AREAS WHICH IS TO
RECEIVE STAINLESS STEEL FINISH.
3. METAL STUD CONTRACTOR TO DETERMINE GAUGE AND RELATED ENGINEERING OF METAL STUDS, TRACKS,
BRIDGING, BLOCKING, KICKERS, FURRING, AND OTHER METAL FRAMING COMPONENTS.
4. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES.
5. WALL TYPES DO NOT INDICATE WALL FINISH MATERIALS IN ALL CASES. SEE INTERIOR ELEVATIONS AND
FINISH SCHEDULE FOR ADDITIONAL FINISH INFORMATION.
6. PROVIDE ADDITIONAL LAYERS OF GYPSUM BOARD, BLOCKING, OR FRAMING AS NEEDED TO ACCOUNT
FOR ALIGNING OF WALL TYPES OR FLUSH CONDITIONS.
7. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF
DECK UNLESS NOTED OTHERWISE. REFER TO WALL TYPES.
8. VERIFY FIRE RATINGS OF WALLS WITH FIRE RATING TABLE, LIFE SAFETY PLANS, AND OTHER NOTATIONS
THROUGHOUT THE DRAWING SET.
9. PROVIDE IN-WALL BLOCKING FOR TENANT PROVIDED FF&E ITEMS. COORDINATE WITH TENANT.
10. REFER TO FINISH PLAN TO COORDINATE AREAS OF OF PLYWOOD SHEATHING REQUIRED FOR WOOD WALL
PANELING
11. REFER TO ARCHITECTURAL FLOOR PLAN TO COORDINATE AREAS OF PLYWOOD SHEATHING REQUIRED FOR
BLOCKING AND MOUNTING OF EQUIPMENT.
Certified By:Scale:Date:Checked By:Drawn By:Revisions:
Job Number:
Drawing Number:
Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 4603220 GA - 6" METAL STUDS @ 16" O.C.
6" METAL RUNNER
DECK
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCALE: 1/2"=1'-0"
WT-5 WALL TYPE5
SCHEDULED BASE
SCHEDULED FLOORING
SCALE: 1/2"=1'-0"
WT-6 WALL TYPE6
2 LAYERS OF 2" WOOD BLOCKING
TOP CAP AS SCHEDULED
STANDARD 8X16
CMU BLOCK WALL.
GROUT AND
REINFORCE AS
REQUIRED
SCHEDULED FLOORING
FIREPROOF SEALANT AS
REQUIRED (NOT REQUIRED IF
SPRINKLERED)
SCALE: 1/2"=1'-0"
WT-7 WALL TYPE7
DECK
SCHEDULED
CEILING SYSTEM
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 3 5/8" METAL STUDS @ 16" O.C.
3 5/8" METAL RUNNER
BRACE TO STRUCTURE
ABOVE AS REQUIRED (TYP)
SCALE: 1/2"=1'-0"
WT-8 WALL TYPE8
DECK
SCHEDULED
CEILING SYSTEM
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
3 5/8" METAL RUNNER
SCALE: 1/2"=1'-0"
WT-9 WALL TYPE9 VARIESSEE REFLECTED CEILING PLANVARIESSEE INTERIOR ELEVATIONSFINISH WOOD TOP CAP (1/4"
PROUD OF WALL)
5/8" GYP. BOARD SHEATHING ON
ONE SIDE (CEMENT BOARD IN
AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 6" METAL STUDS @ 16" O.C.
6" METAL RUNNER
BRACE TO STRUCTURE
ABOVE AS REQUIRED (TYP)
SCALE: 1/2"=1'-0"
WT-10 WALL TYPE10
DECK
SCHEDULED
CEILING SYSTEM
VARIESSEE REFLECTED CEILING PLANCONFIRM WITH TENANT5/8" XP DRYWALL & FRP (CAULKED
JOINTS & TRIM) ON COOLER SIDE
AND VAPOR BARRIER UNDER 5/8"
GYP. BOARD (OR DUROCK AT TILE
LOCATIONS) TO FINISHED SIDE(S)
ATTACHED WITH METAL SCREW
FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 3 5/8" METAL STUDS @ 16" O.C.
3 5/8" METAL RUNNER CONFIRM WITHKITCHEN SUPPLIER3"x3"x8" L CLIP ANGLES AT
4'-0" O.C. , MECH.
FASTENED TO UNDERSIDE
OF SLAB, BOTH SIDES OF
WALL
EXISTING WALL. MAINTAIN ANY
CONTINUOUS FIRE SEPARATIONS
AS INDICATED ON THE LIFE
SAFETY PLAN
EXISTING WALL. MAINTAIN ANY
CONTINUOUS FIRE SEPARATIONS
AS INDICATED ON THE LIFE
SAFETY PLAN
EXISTING WALL. MAINTAIN ANY
CONTINUOUS FIRE SEPARATIONS
AS INDICATED ON THE LIFE
SAFETY PLAN
3-1/2" R11 UNFACED
INSULATION IN STUD CAVITIES
6" R19 UNFACED INSULATION
IN STUD CAVITIES
3-1/2" R11 UNFACED
INSULATION IN STUD CAVITIES
DOWEL AS REQUIRED
VERTICAL REINFORCEMENT
AS REQUIRED
COORDINATE REQUIREMENTS WITH
TENANT
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 2 1/2" METAL STUDS @ 16" O.C.
2 1/2" METAL RUNNER
BRACE TO STRUCTURE
ABOVE AS REQUIRED (TYP)
SCALE: 1/2"=1'-0"
WT-11 WALL TYPE11
DECK
SCHEDULED
CEILING SYSTEM
VARIESSEE REFLECTED CEILING PLANEXISTING WALL. MAINTAIN ANY
CONTINUOUS FIRE SEPARATIONS
AS INDICATED ON THE LIFE
SAFETY PLAN
3-1/2" R11 UNFACED
INSULATION IN STUD CAVITIES
WT-11A - WALL TYPE AS SHOWN
WT-11B - WALL TYPE TERMINATED AT BOTTOM OF SCHEDULED CEILING
09/23/21