Loading...
HomeMy WebLinkAboutA01020 GA - 3 5/8" METAL STUDS @ 16" O.C. SCHEDULED CEILING SYSTEM 3 5/8" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) DECK 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCALE: 1/2"=1'-0" WT-1 WALL TYPE1 SCHEDULED BASE SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLANVARIESSEE REFLECTED CEILING PLAN5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. SCHEDULED CEILING SYSTEM 3 5/8" METAL RUNNER SCALE: 1/2"=1'-0" WT-3 WALL TYPE3 CONFIRM WITHKITCHEN SUPPLIER5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 6" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER (BRACE AS REQUIRED) STAINLESS STEEL PASS THROUGH WINDOW BY KITCHEN EQUIPMENT VENDOR SCALE: 1/2"=1'-0" WT-4 WALL TYPE4 WT-1A - WALL TYPE AS SHOWN WT-1B - WALL TYPE WITHOUT INSULATION SCALE: 1/2"=1'-0" WT-2 WALL TYPE2 WT-2A - WALL TYPE AS SHOWN WT-2B - WALL TYPE WITHOUT INSULATION 1/2" = 1'-0"ARCHITECTURAL WALL TYPES A010CONFIRM FINAL HEIGHT WITHCOUNTERTOPINSTALLATION PRIORTO ROUGH IN5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 18 GA - 6" METAL STUDS @ 16" O.C. 6" METAL RUNNER (BRACE AS REQUIRED) COUNTERTOP. REFER TO INTERIOR SECTIONS/ELEVATIONS FOR FINAL DESIGN WOOD BLOCKING AS REQUIRED GENERAL WALL TYPE NOTES 1. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT TOILET ROOMS, KITCHENS, JANITORS CLOSETS, SINKS, OTHER SIMILAR LOCATIONS, AND ANY WALL WHICH IS TO RECEIVE A TILE FINISH. IF TWO LAYERS OF GYPSUM BOARD ARE INDICATED IN A WALL ASSEMBLY ONLY THE OUTSIDE LAYER NEED BE REPLACED WITH CEMENT BOARD. 2. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT KITCHEN AND SIMILAR AREAS WHICH IS TO RECEIVE STAINLESS STEEL FINISH. 3. METAL STUD CONTRACTOR TO DETERMINE GAUGE AND RELATED ENGINEERING OF METAL STUDS, TRACKS, BRIDGING, BLOCKING, KICKERS, FURRING, AND OTHER METAL FRAMING COMPONENTS. 4. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES. 5. WALL TYPES DO NOT INDICATE WALL FINISH MATERIALS IN ALL CASES. SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR ADDITIONAL FINISH INFORMATION. 6. PROVIDE ADDITIONAL LAYERS OF GYPSUM BOARD, BLOCKING, OR FRAMING AS NEEDED TO ACCOUNT FOR ALIGNING OF WALL TYPES OR FLUSH CONDITIONS. 7. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE. REFER TO WALL TYPES. 8. VERIFY FIRE RATINGS OF WALLS WITH FIRE RATING TABLE, LIFE SAFETY PLANS, AND OTHER NOTATIONS THROUGHOUT THE DRAWING SET. 9. PROVIDE IN-WALL BLOCKING FOR TENANT PROVIDED FF&E ITEMS. COORDINATE WITH TENANT. 10. REFER TO FINISH PLAN TO COORDINATE AREAS OF OF PLYWOOD SHEATHING REQUIRED FOR WOOD WALL PANELING 11. REFER TO ARCHITECTURAL FLOOR PLAN TO COORDINATE AREAS OF PLYWOOD SHEATHING REQUIRED FOR BLOCKING AND MOUNTING OF EQUIPMENT. Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 4603220 GA - 6" METAL STUDS @ 16" O.C. 6" METAL RUNNER DECK 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCALE: 1/2"=1'-0" WT-5 WALL TYPE5 SCHEDULED BASE SCHEDULED FLOORING SCALE: 1/2"=1'-0" WT-6 WALL TYPE6 2 LAYERS OF 2" WOOD BLOCKING TOP CAP AS SCHEDULED STANDARD 8X16 CMU BLOCK WALL. GROUT AND REINFORCE AS REQUIRED SCHEDULED FLOORING FIREPROOF SEALANT AS REQUIRED (NOT REQUIRED IF SPRINKLERED) SCALE: 1/2"=1'-0" WT-7 WALL TYPE7 DECK SCHEDULED CEILING SYSTEM 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) SCALE: 1/2"=1'-0" WT-8 WALL TYPE8 DECK SCHEDULED CEILING SYSTEM 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 3 5/8" METAL RUNNER SCALE: 1/2"=1'-0" WT-9 WALL TYPE9 VARIESSEE REFLECTED CEILING PLANVARIESSEE INTERIOR ELEVATIONSFINISH WOOD TOP CAP (1/4" PROUD OF WALL) 5/8" GYP. BOARD SHEATHING ON ONE SIDE (CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 6" METAL STUDS @ 16" O.C. 6" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) SCALE: 1/2"=1'-0" WT-10 WALL TYPE10 DECK SCHEDULED CEILING SYSTEM VARIESSEE REFLECTED CEILING PLANCONFIRM WITH TENANT5/8" XP DRYWALL & FRP (CAULKED JOINTS & TRIM) ON COOLER SIDE AND VAPOR BARRIER UNDER 5/8" GYP. BOARD (OR DUROCK AT TILE LOCATIONS) TO FINISHED SIDE(S) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER CONFIRM WITHKITCHEN SUPPLIER3"x3"x8" L CLIP ANGLES AT 4'-0" O.C. , MECH. FASTENED TO UNDERSIDE OF SLAB, BOTH SIDES OF WALL EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES 6" R19 UNFACED INSULATION IN STUD CAVITIES 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES DOWEL AS REQUIRED VERTICAL REINFORCEMENT AS REQUIRED COORDINATE REQUIREMENTS WITH TENANT 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 2 1/2" METAL STUDS @ 16" O.C. 2 1/2" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) SCALE: 1/2"=1'-0" WT-11 WALL TYPE11 DECK SCHEDULED CEILING SYSTEM VARIESSEE REFLECTED CEILING PLANEXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES WT-11A - WALL TYPE AS SHOWN WT-11B - WALL TYPE TERMINATED AT BOTTOM OF SCHEDULED CEILING 09/23/21