HomeMy WebLinkAboutA400HOOD SOCIALW1W1
P1
P1
P1
P1
P1 P1
P1
P1
P1
P1
R1 R1 R1
T1
T1 T1
T1
T1
P1
P1
T1
W2
P3
W2
W3 P1
W2
R3 R3
R3
S1
S1
S1
S1
S1
S1
S1
S1 S1
W4
W4
W5 W6
P1 P1
W3
S3
S3
P1 P1
S2
P1 P1P1
W4
L1
L1
L1
L1
L1
L1
S5 S5
S5
S5 S5
S5
S5 S5
S5
S5 S5
P2
P2
R2
W3
L1 L1 L1
EM3
EM1EM1
EM1
EM1
EM1
EM1
EM1
EM1
EM2
EM2
EM2
EM3
EM3
EM3
W7
W7
S
T2
R1
R1
R1
R1
R3 R3
R3
R3
R3
S2
S2
EXISTING
VERTICAL SHAFT
S4 S4
S4 S4
W7
SS
FP1 FP1
FP1 FP1
FP1
FP1FP1
FP1
FP1
FP1 FP1
FP1
FP1
FP1
FP1FP1
FP1
FP1
FP1
FP1
NL
NL
NL
NL
H1
H1
H1
H1
H1
H1
H1
H1
R4
R4
R4
R4
R4
R4
W7
R4
R4
R4
R4
R4 R4
R4
R4R4
FAN1 FAN1
EM1
EM2
S1
S1
EXISTING AWNING EXISTING
AWNING
EXISTING
AWNING
EXISTING
AWNING
EXISTING
AWNING
COOLER
COOLER
S6 S6 S6
S6 S6 S6
SCALE: 1/8"=1'-0"
REFLECTED CEILING PLAN1
Certified By:Scale:Date:Checked By:Drawn By:Revisions:
Job Number:
Drawing Number:
Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032KEYED REFLECTED CEILING NOTES#
GENERAL REFLECTED CEILING PLAN NOTES
ACT-1: New 2x4 Suspended ceiling system, 15/16"
white grid and non-porous vinyl, by Contractor
NL Night Light Fixture
Height indication above finished floorx'-x" A.F.F.
EM2: Emergi-Lite #TA-PEN-2RM, Edge-lit emergency exit sign w/
red letters on mirror finish, by Contractor
EM1: New Emergency Light: Sure-Lites, Apel Series in
black finish.
+ XX" Mounting height to center above finished floor
REFLECTED CEILING LEGEND
R1: New LED 6" Recessed downlight fixture: Contech K6SA w/
black trim, dimmable, 19W LED 2700K
S
D
Single Pole Switch
Dimmer Switch (Install LED compatible dimmer where applicable)
3 3-Way Switch
OS Occupancy Sensor (at ceiling): provided and installed by
contractor to meet all requirements of the 2010 Indiana Energy
Conservation Code
Switching Intent, verify with existing conditions and modify as
needed for new configuration shown
R2: Same as 'R1', but 3" dia.
L1: New Linear LED Tape: Contech Lighting,TLT240V0 70-100 LM/FT
- 30, 1.3W/ FT LED 2700K lamping - Contractor to verify quantity to
fill entire length of liquor shelf, wall cap or bar top overhang and
transformer requirements prior to order.
FP1: New 2x4' Recessed LED: Metalux FPanel LED Panel Series
912809, 40W 3500K lamping
NOTE: FIXTURES BELOW ARE TO BE PROVIDED AND INSTALLED BY
CONTRACTOR.
NOTE: FIXTURES BELOW ARE TO BE PROVIDED BY PHANOMEN/design AND INSTALLED BY CONTRACTOR
EM3: New Combination exit sign and emergency light: Evenlite
Telesis TCXCOM Black finish, red LED letters
T1: New line voltage track & head: spec: CTL905 Series Eclipse
Curve LED Track CTL9052WF27CD-B with Black finish, 14W,
2700K, dimmmable (confirm mounting height with designer)
DECORATIVE LIGHTING SCHEDULE
IMAGE SYMBOL DESCRIPTION NOTES
P2
P3
NEW CUSTOM CEILING
MOUNT FIXTURE WITH 21
DROPS. 2W LED LAMPING PER
DRO, 2700K
MOUNT AT X'-XX"
AFF TO BOTTOM
OF FIXTURE
NEW CHANDELIER; 6W
LED LAMPING, 10 LAMPS,
2700K
MOUNT AT X'-XX"
AFF TO BOTTOM
OF FIXTURE
MOUNT AT X'-XX"
AFF TO CENTER OF FIXTURE
W1
W2
W3
CEILING MOUNTED
CEILING MOUNTED
S1
S3
N
S
W E
9'-0" A.F.F.
ACT-1
10'-0" A.F.F.
PT-X
10'-0" A.F.F.PT-X
1. REFER TO FINISH PLAN FOR MORE INFORMATION ON PAINT COLORS AT GYPSUM BOARD BULKHEADS. ALL GYPSUM BOARD
BULKHEADS TO BE PAINTED PT-X, UNLESS NOTED OTHERWISE.
2. PROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS, CONFIRM EXISTING.
3. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHT AND CEILING PLENUM
CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT
INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE
COMMENCEMENT OF ANY WORK.
4. CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND STATE AND
LOCAL BUILDING CODES.
5. ALL DIMENSIONS ARE FROM CENTERLINE TO CENTERLINE OF FIXTURES.
6. ALL GYP. BOARD WALLS, CEILINGS AND BULKHEADS, SHALL BE A SMOOTH LEVEL 4 FINISH AS OUTLINED IN GYPSUM ASSOCIATION
GA-214.
7. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF
DOOR FRAME, UNLESS NOTED OTHERWISE. CONFIRM ALL NEW SWITCH LOCATIONS WITH OWNER PRIOR TO ROUGH-IN.
8. ALL MATERIALS EXPOSED WITHIN THE PLENUM MUST BE NONCOMBUSTIBLE OR SHALL COMPLY WITH LABELING, FLAME AND SMOKE
DEVELOPMENT RATINGS AS SPECIFIED IN THE CURRENT EDITION OF THE INDIANA MECHANICAL CODE.
9. MEANS OF EGRESS ILLUMINATION SHALL BE LOCATED IN ACCORDANCE WITH SECTION 1006, IBC (675 IAC 13-2.5).
10. INSTALL PHANOMEN PROVIDED DECORATIVE PENDANTS AT HEIGHTS SPECIFIED IN LIGHTING SCHEDULE. PROVIDE BLOCKING AS
REQUIRED. CONTACT PHANOMEN/design FOR JUNCTION BOX LOCATION(S) AND MOUNTING HEIGHTS.
11. ALL AREAS OF OPEN DECK TO REMAIN EXPOSED. PAINT DUCTWORK PT-X.
1 L1 TO BE INSTALLED IN BAR SHELVING FEATURE.
WAGNER SIGNS TO INSTALL LIT SIGN PROVIDED BY TENANT, CONTRACTOR TO PROVIDE BLOCKING IN
CEILING AS REQUIRED AND INSTALL 120 VOLT, 6-10 AMP LOAD ELECTRICAL BOX. COORDINATE ALL
MOUNTING AND ELECTRICAL REQUIREMENTS WITH WAGNER SIGNS, CONTACT: DUSTIN FLICK AT
DUSTIN@WAGNER-SIGNS.COM OR (317)788-0202. COORDINATE WITH STRUCTURAL ENGINEER AS REQUIRED.
INSTALL "L1" AT BAR FRONT COUNTERTOP.
DRYWALL BULKHEAD TO EXTEND TO DECK. PROVIDE CEILING BRACING AND/OR BLOCKING AS
REQUIRED FOR MILLWORKER PROVIDED DECORATIVE WOOD CEILING FEATURE. PHANOMEN TO
COORDINATE PRICING AND FINISHES WITH KDMI. REFER TO DETAILS ON SHEET A401 FOR ADDITIONAL
INFORMATION.
INSTALL "L1" IN WALL/CEILING FEATURE AT THIS LOCATION.
VERTICAL FACE OF BULKHEAD TO BE FINISHED WITH WALLCOVERING WC-8.
CUSTOM METAL CEILING TO BE PROVIDED AND INSTALLED BY PHANOMEN/design. EXACT DESIGN AND
MOUNTING HEIGHT: TBD.
INSTALL RECESSED LIGHT FIXTURE IN MILLWORK. REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHT
AND LOCATION. COORDINATE WITH MILLWORKER AS REQUIRED.
CUSTOM METAL ARCH TO BE PROVIDED AND INSTALLED BY PHANOMEN/design AND INSTALLED ON BAR
TOP.
INSTALL PHANOMEN PROVIDED TECTUM CEILING PANELS DIRECTLY TO THE DECK. CONTRACTOR TO
PLACE PANELS RANDOMLY AND VERIFY FINAL LAYOUT WITH DESIGNER.
7'-0" A.F.F. DRYWALL HEADER, PAINT PT-X.
WAGNER SIGNS TO INSTALL TENANT PROVIDED SIGNAGE ONTO EXISTING AWNING. CONTRACTOR TO
PROVIDE (1) 20 AMP 120 VOLT CIRCUIT. SIGNS CONNECTED TO A TIMER. SIGN TO BE SOURCED FROM
WAGNER SIGNS, CONTACT: DUSTIN FLICK AT DUSTIN@WAGNER-SIGNS.COM OR (317)788-0202 FOR
ADDITIONAL MOUNTING INFORMATION.
INSTALL LIT ART PROVIDED BY PHANOMEN/design AT THIS LOCATION, PROVIDE JUNCTION BOX.
COORDINATE ELECTRICAL REQUIREMENTS AND SWITCHING WITH PHANOMEN/design.
INSTALL DRYWALL BULKHEAD AT 7'-0" A.F.F. PAINT VERTICAL FACE PT-X.
INSTALL ACT-1 CEILING AT 8'-6" A.F.F. AT THE HIGH LANDING.
INSTALL SCHLUTER, JOLLY IN TBD FINISH ON OUTSIDE EDGES OF TILE INSTALLED ON CEILING.
PROVIDE ALLOWANCE FOR PAINTING ALL EXPOSED CONDUIT AND SPRINKLER LINES IN ALL AREAS OF
EXPOSED CEILING. COORDINATE WITH DESIGNER FOR FINAL INTENT. EXPOSED DUCTWORK TO REMAIN
UNFINISHED GALVANIZED STEEL.
SUSPEND TV FROM CEILING IN FRONT OF EXPOSED CONCRETE COLUMN. PROVIDE ALL SUPPORTS AS
REQUIRED, CONFIRM MOUNTING HEIGHT WITH TENANT.
SCONCE TO BE MOUNTED TO FRONT FACE OF MILLWORK. REFER TO INTERIOR DETAILS FOR MOUNTING
HEIGHT AND LOCATION.
REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED LIGHT FIXTURE LOCATIONS AND MOUNTING
HEIGHTS.
NEW PERGOLA; DRAWINGS TO BE PROVIDED BY OTHERS.
10'-0" A.F.F. DRYWALL HEADER TO EXTEND TO DECK, PAINT PT-X.
CUSTOM PAINTED CEILING DESIGN WITH NEON LIGHTS BY PHANOMEN/design. COORDINATE POWER
WITH PHANOMEN/design.
INSTALL 36X36 ACCESS PANEL. CONTRACTOR TO COORDINATE LOCATION WITH PHANOMEN/design.
COORDINATE COOLER LIGHTING AND CEILING WITH TENANT.
PAINT VERTICAL FACE OF BULKHEAD PT-X.
INSTALLED SCHEDULED LIGHT FIXTURE IN BULKHEAD, CENTERED OVER DOOR.
2
3
4
5
6
7
0 5 10 20 40
9'-0" A.F.F.
PT-X
10'-0" A.F.F.
ACT-1
10'-0" A.F.F.
WT-X
10'-0" A.F.F.
WT-X
14'-6" A.F.F.
PT-X
14'-0" A.F.F.
PT-X
13'-4" A.F.F.
PT-X
12'-4" A.F.F.WD-X
12'-0" A.F.F.
WD-X
10'-0" A.F.F.
PT-X
13'-4" A.F.F.
PT-X
13'-4" A.F.F.PT-X
10'-0" A.F.F.
PT-X
8
R3: New LED 6" Recessed downlight fixture: Contech K6SA w/
white trim, dimmable, 19W LED 2700K
P1: New 6" Pendant: Contech CYL6, dimmable, in matte black
finish, 10W LED 2700K lamping. Coordinate mounting height with
PHANOMEN/design.
CEILING MOUNTED AND
WALL MOUNTED. REFER TO
INTERIOR ELEVATIONS FOR
DETAILSS2
12'-6" A.F.F.
WD-X
W4
REFER TO ELEVATIONS FOR
MOUNTING HEIGHT
W5
W6
1
12
12
3
2
4
5
4
6
7
8
9
9
9
9
1
A401
10
10
11
11
W7: New Exterior Egress fixture: Match Adjacent Tenant
11
12
13
13
14
14
15
15
15
VEST.
101
ENTRY
102
DINING
103
WOMEN'S
RESTROOM
104
MEN'S
RESTROOM
105
BAR
106
DINING
107
PRIVATE
DINING
108
KITCHEN
109
OFFICE
111
TRASH
110
9'-0" A.F.F.
PT-X
NEWSTRING LIGHT 60W,
WET RATED, 2700K
A401
6
EXT DECK
EXT DECK
EXT DECK
EXT DECK
16
16
16
16
16
17
17
18
18
18
REFLECTED CEILING PLAN
A400
19
19
20
20
R4: New LED Pergola lights by pergola manufacturer. 4.2"
recessed, dimmable, 6W, 2700K warm white lamping, 15 degree
spot, dark bronze trim
NEW EXTERIOR CEILING FAN:
SPECIFICATION: TBD. NO
LIGHT
HT: New Contractor provided heaters. Refer to MEP plans for
specification
MOUNT AT X'-XX"
AFF TO BOTTOM
OF FIXTURE
MOUNT TO BOTTOM OF
AWNING
21
21
22
T2: New line voltage track & head: spec: CTL8070 Series
Eclipse Curve LED Track CTL8070M27D_, 9W, 2700K, finish: TBD,
dimmable (confirm mounting height with designer)
22
S5: SURFACE MOUNT CUSTOM LIGHT
FIXTURE. PROVIDED BY PHANOMEN.
2W LED, 5 LAMPS PER FIXTURE, 2700K
S5
S4
FAN 1
NEW SURFACE MOUNT;
4W LED LAMPING, 2700K
NEW SURFACE MOUNT;
6W LED LAMPING, 2700K
NEW ADJUSTABLE
SURFACE MOUNT; 4W
LED LAMPING, 2700K
NEW SCONCE; 4W LED
LAMPING, 2700K
NEW SCONCE; 4W LED
LAMPING, 2700K
NEW SCONCE; 6W LED
LAMPING, 2700K
NEW SCONCE; 6W LED
LAMPING, 2700K
NEW SCONCE; 4W LED
LAMPING, 2700K
NEW SCONCE; 4W LED
LAMPING, 2700K
5
MOUNT AT X'-XX"
AFF TO CENTER OF FIXTURE,
SURFACE MOUNT TO EXPOSED
CONCRETE COLUMN, PAINT
CONDUIT, PT-X
MOUNT AT X'-XX"
AFF TO CENTER OF FIXTURE
MOUNT AT X'-XX"
AFF TO CENTER OF FIXTURE
REFER TO ELEVATIONS FOR
MOUNTING HEIGHT
9'-0" A.F.F.
PT-X
9'-0" A.F.F.
PT-X
S6: New Fluorescent Surface Mount Cooler/ Freezer Light:
CCL-8804OC120, 48" L
23
23
23
23
24
24
24
25
25
4
26
26
09/23/21