HomeMy WebLinkAboutSocial Cantina_Permit Set_08.20.213 YDDUMPSTERD DA B CE 3 YDDUMPSTER CO2OIL TANK36"X72"POS/ RESETPOS HOST30x48 30x48 30x48 POS/ RESET RESET EP EP COOLER COOLER HOOD COVER SHEET A000 SOCIAL CANTINA RAILYARD AT MIDTOWN 350 MONON BLVD., SUITE 10 CARMEL, IN 46032 DRAWING INDEX INTERIOR DESIGN: PHANOMEN/ design 934 FT. Wayne Ave. Indianapolis, IN 46202 (317) 439-4355 LOREE O. EVERETTE TENANT: FINNEY HOSPITALITY 101 N. College Ave. Bloomington, IN 47404 (317) 378-7274 NATHAN FINNEY PROJECT TEAM COURTESY OF GOOGLEPROJECT LOCATION BUILDING CODE: 2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE: 675 IAC 13-2.6) PLUMBING CODE: 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE: 675 IAC 16-1.4) ELECTRICAL CODE: 2009 INDIANA ELECTRICAL CODE (2008 NFPA-70: 675 IAC 17-1.8) MECHANICAL CODE: 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE: 675 IAC 18-1.6) FIRE / LIFE SAFETY CODE: 2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE: 675 IAC 22-2.5) ACCESSIBILITY CODE: 2008 INDIANA BUILDING CODE CHAPER 11 - ACCESSIBILITY (675 IAC 13-2.5-12 CHAPTER 11) ENERGY CODE: 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1, 2007 EDITION: 675 IAC 19-4) ELEVATOR CODE: 2011 INDIANA ELEVATOR SAFETY CODE (ANSI/ASME A17.1, 2007 EDITION: 675 IAC 21-3) GAS CODE: 2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE: 675 IAC 25-3) APPLICABLE CODES KITCHEN CONSULTANT: C & T DESIGN AND EQUIPMENT CO. 2750 Tobey DR. Indianapolis, IN 46219 (317) 644-7833 CHRIS MONICO NO SCALESCALE: N.T.S. LOCATION PLAN A000 1 N S W E PROJECT LOCATION GENERAL CONTRACTOR: MEYER-NAJEM CONSTRUCTION 11787 Lantern Rd. Suite 100 Fishers, IN 46038 (317)577-0007 MAYNARD SOUKUP NICK GEIGER SCALE: N.T.S. VICINITY MAP A000 2 N S W E Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032GENERAL FIRE PROTECTION NOTES RENOVATED AREAS SHALL BE 100% SPRINKLERED.A. COORDINATE CLOSELY WITH OTHER TRADES. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.B. ALL SPRINKLER WORK SHALL BE INSTALLED PER NFPA 13, BUILDING CODE, AND OWNER'S INSURANCE CARRIER REQUIREMENTS. C. MAKE PROVISIONS FOR THE DRAINING AND PROVIDE INSPECTOR TESTS AS REQUIRED, ALL DRAIN PIPING SHALL BE PIPED TO OUTSIDE OR INDIRECTLY TO SINK OR FLOOR DRAIN. D. COORDINATE EXACT LOCATION OF PIPING AND HEADS WITH REFLECTED CEILING PLANS, MECHANICAL AND ELECTRICAL DRAWINGS.E. ALL HOSE VALVES AND FIRE DEPARTMENT CONNECTIONS SHALL MATCH LOCAL FIRE DEPARTMENT THREADS. F. ALL FIRE SUPPRESSION WORK SHALL BE PERFORMED BY A FIRE PROTECTION CONTRACTOR LICENSED IN THE STATE OF OHIO. G. ALL SPRINKLER HEADS SHALL BE LOCATED IN CENTER OF CEILING TILE IN AT LEAST ONE DIRECTION. H. SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING FOR SPRINKLER WORK IN ALL AREAS OF BUILDING. REFER TO SPECIFICATIONS. I. ALL ARMOVER PIPING RELATED TO SPRINKLERS TO BE DEMOLISHED ARE TO REMOVED BACK TO THE OUTLET ON THE BRANCHLINE. J. WHEN MODIFYING EXISTING SPRINKLER SYSTEMS, SPRINKLER CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING SPRINKLER ZONES. COORDINATE WITH NEW FIRE RATING PLANS IF APPLICABLE. K. FIRE PROTECTION CONTRACTOR IS REQUIRED TO RAISE/REWORK ALL EXISTING PIPING AS NEEDED TO ACCOMMODATE NEW CEILINGS AND HIGHER CEILING HEIGHTS AS APPLICABLE. L. ELECTRICIAN: DESIGN AND BUILD ELECTRICAL (317) 782-1887 DANIEL KIDWELL PLUMBING: FERRER MECHANICAL 2801 Fortune Circle East, Suite F., Indianapolis, IN 46241 (317) 757-2019 Rick Jordan MECHANICAL SWIFT AIR MECHANICAL, INC. (317)547-5355 RANDY SMILEY ALAN COX LOW VOLTAGE & AV: EXPERIENCE TECHNOLOGIES (812)323- 9533 ERIC STIENING PERGOLA: THE SMART PERGOLA 12958 Brighton Ave. Carmel, IN 46032 (317) 682-4072 CLAUDIO BERTOLINI LANDLORD: BARRETT & STOKLEY, INC. 3755 E. 82nd Street Indianapolis, IN 46240 (317) 845-4171 THOMAS E. MARIANI Social Cantina Drawing Index PermitSet07/30/2021X - Included without Revisions O - Included with Revisions General A000 Cover Sheet X A001 General Notes X A002 Life Safety Plan X X Architectural A010 Architectural Wall Types X A100 Architectural Floor Plan & Door Schedule X A102 Enlarged Restroom Plan, Elevations, & Notes X A103 Ramp Plan and Details X A200 Interior Elevations X A201 Interior Elevations X A202 Interior Elevations X A203 Interior Elevations X A205 Interior Sections X A400 Reflected Ceiling Plan X A401 Dimensioned Reflected Ceiling Plan & Details X A701 Finish Floor Plan X A800 Furniture Plan X Mechanical M100 HVAC Plan X M200 HVAC Schedules X Electrical E101 X E102 Electrical Schedules and Details X E103 Electrical Schedules and Details X E201 North Floor Plan - Lighting X E202 South Floor Plan - Lighting X E301 Floor Plan - Power X E302 Enlarged Kitchen Plan - Power X E401 Floor Plan - Fire Alarm X E501 Floor Plan - HVAC Connections X Plumbing P000 Plumbing General Information X P001 Plumbing Detail and Schedules X P002 Plumbing Schedules X P003 Plumbing Specifications X P100 Underground Plumbing Plan X P101 First Floor Vent and Natural Gas Floor Plan X P102 First Floor Domestic Water Plan X P103 Sanitary Waste and Vent Riser Diagram X 09/23/21 NO SCALEGENERAL NOTES A001 # # SHT-NO # SHT-NO FIN CLG HGT GRAPHIC SYMBOLS WORK POINT, CONTROL POINT, OR DATUM POINT GRID LINES SECTION SHEET WHERE DRAWN DETAIL NUMBER SHEET WHERE DRAWN ROOM NAME ROOM NUMBER PLAN NOTE INDIANA NORTH ARROW DESCRIPTIONSYMBOL CENTER LINE DIM COLUMN CENTERLINES DOOR JAMB (HINGE SIDE, TYPICAL, UNLESS NOTED OTHERWISE) 6" GWB TO CONTINUE UNINTERRUPTED ACROSS VARIOUS SUBSTRATES AND PARTITION TYPES, UNLESS NOTED OTHERWISE SHEET WHERE DRAWN INTERIOR ELEVATION A 1 ABBREVIATIONS ROOM 207 # DOOR SEE DOOR SCHEDULE A/C AIR CONDITIONING AC ACOUSTICAL ADA AMERICANS WITH DISABILITIES ACT ADJ ADJACENT AFF ABOVE FINISHED FLOOR ALUM ALUMINUM ARCH ARCHITECTURAL AVG AVERAGE BLDG BUILDING BM BEAM / BENCHMARK B.O. BOTTOM OF BSMT BASEMENT BUR BUILT UP ROOF BW BOTTOM OF WALL CAB CABINET CIP CAST IN PLACE CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLOS CLOSET CLR CLEAR CMT CERAMIC MOSAIC TILE CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN COMM COMMUNICATION CONC CONCRETE CONF CONFERENCE CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CPT CARPET COORD COORDINATE CORR CORRIDOR CPT CARPET CT CERAMIC TILE CTR CENTER CWT CERAMIC WALL TILE DBL DOUBLE DEMO DEMOLITION DET / DTL DETAIL DIA DIAMETER DIAG DIAGONAL DIM(S) DIMENSION(S) DIV DIVISION / DIVIDED DN DOWN DPM DAMP PROOF MEMBRANE DS DOWNSPOUT DWG DRAWING DWR DRAWER E EAST EA EACH EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR / ELEVATION EO EDGE OF EPDM ETHYLENE PROPYLENE DIENE TERPOLYMER MEMBRANE EPS EXTRUDED POLYSTYRENE EQ EQUAL EQUIP EQUIPMENT EX / EXIST EXISTING EXP EXPANSION / EXPOSED EXT EXTERIOR EWC ELECTRIC WATER COOLER FA FIRE ALARM FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FIN FINISH FLR FLOOR FOF FACE OF FINISH FOS FACE OF STUD FP FIRE PROTECTION / FIREPROOFING FT FOOT / FEET FTG FOOTING FTR FIRE TREATED GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT GFRG GLASS FIBER REINFORCED GYPSUM GL GLASS / GLAZING GWB GYPSUM WALL BOARD HC HOLLOW CORE HDWE HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HR HOUR HT HEIGHT HVAC HEATING / VENTILATING / AIR CONDITIONING HWH HOT WATER HEATER ID INSIDE DIAMETER IG INSULATED GLASS INCL INCLUDE(D,ING) INSUL INSULATION INT INTERIOR JAN JANITOR JT JOINT KIT KITCHEN LAM LAMINATE LAV LAVATORY LH LEFT HAND LIN LINOLEUM LOC LIMIT OF CONTRACT LP LOW POINT LTG LIGHTING MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MECH MECHANICAL MFG MANUFACTURING MFR MANUFACTURER MGR MANAGER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MTL METAL N NORTH NAT NATURAL NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NR NOT RATED NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE O/ OVER OC ON CENTER OD OUTSIDE DIAMETER OH OVERHEAD OPH OPPOSITE HAND OPNG OPENING OPP OPPOSITE ORD OVERFLOW ROOF DRAIN OSB ORIENTED STRAND BOARD PC PIECE / PERSONAL COMPUTER PERF PERFORATED PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD PR PAIR PREFAB PREFABRICATED PRES PRESIDENT PRTD / PTRD PRESSURE TREATED PT PAINT PTD PAINTED QTY QUANTITY QTILE QUARRY TILE R RADIUS / RISER RCP REFLECTED CEILING PLAN RD ROOF DRAIN REC RECESSED REF REFERENCE REFRIG REFRIGERATOR REINF REINFORCE(D, ING) REQD REQUIRED REV REVISION RH RIGHT HAND RM ROOM RO ROUGH OPENING RR RESTROOM RWC RAIN WATER CONDUCTOR S SOUTH SCHED SCHEDULE SDT STATIC DISSIPATIVE TILE SECT SECTION SECY SECRETARY SHT SHEET SIC SOUND ISOLATION CEILING SIM SIMILAR SPEC SPECIFIED / SPECIFICATION SQ SQUARE SQ FT SQUARE FEET SSM SOLID SURFACE MATERIAL SS STAINLESS STEEL STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STN STONE STOR STORAGE STR STAIR STRUCT STRUCTURAL SY SQUARE YARD T TREAD T&G TONGUE AND GROOVE T/O THROUGHOUT TELE TELEPHONE TEMP TEMPORARY TERR TERRAZZO THRES THRESHOLD T.O. TOP OF TRANSP TRANSPARENT TRCT TERRACOTTA TILE TW TOP OF WALL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VP VICE PRESIDENT VWC VINYL WALLCOVERING W WEST W/ WITH WC WATERCLOSET WD WOOD WDW WINDOW W/O WITHOUT WP WATERPROOF WT WEIGHT WWF WELDED WIRE FABRIC MISCELLANEOUS ITEMS WT# # SHT-NO GLASS/WINDOW TYPE WALLTYPE SEE WALLTYPES REVISION# FLRRFLRL FLOOR FINISH DESIGNATION SUBSTRATE/FINISH CEILING HEIGHT A.F.F. N S W E 101 Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032GENERAL NOTES: A. UNLESS OTHERWISE INDICATED, GENERAL NOTES APPLY TO ALL WORK AND ALL DRAWINGS IN THIS SET AND SHALL EXTEND TO ANY CHANGES, EXTRAS OR ADDITIONS AS AGREED TO DURING THE COURSE OF THE WORK. B. THESE DRAWINGS AND COPIES THEREOF ARE LEGAL INSTRUMENTS OF SERVICE FOR USE OF THE OWNER ONLY. C. THIS PROJECT IS DESIGNED AND DOCUMENTED PER THE DESIGNER'S INTERPRETATION OF THE CODE REQUIREMENTS.  VARIOUS GOVERNING AGENCIES SOMETIMES INTERPRET CODES, LAWS AND ORDINANCES DIFFERENTLY.  THESE AGENCIES HAVE JURISDICTION TO REQUIRE CHANGES IN DESIGN AND CONSTRUCTION.  ANY CHANGES OR MODIFICATIONS TO THE DESIGN MAY NECESSITATE PRICE ADJUSTMENTS. D. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA), UNIVERSAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS. E. THE ERRORS AND OMISSIONS DESIGN LIABILITY FOR THE PROJECT SHALL BE LIMITED TO THE DESIGN COST OF CORRECTING THE DEFICIENCY. F. CONTRACTOR SHALL VISIT AND INSPECT THE PROJECT SITE PRIOR TO SUBMITTAL OF BID AND FAMILIARIZE THEMSELVES WITH THE CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE DESIGNER IMMEDIATELY. FAILURE OF CONTRACTOR TO PERFORM IN THIS MANNER DOES NOT ALLOW FOR ADDITIONAL COST TO THE OWNER. NO SUBSEQUENT EXTRAS OR ADDITIONS WILL BE ALLOWED ON ANY CLAIM OF LACK OF KNOWLEDGE OF CONDITIONS OR CIRCUMSTANCES ABOUT WHICH THE CONTRACTOR COULD HAVE INFORMED THEMSELVES. G. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR COMPLETION OF THIS PROJECT. H. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER'S F.F.E. I. CONTRACTOR SHALL MAKE KNOWN ANY LIMITATIONS, EXCLUSIONS, OR MODIFICATIONS TO THE PROJECT DURING THE PRICING PHASE OF THE PROJECT. UNLESS NOTED ALL WORK SHOWN ON THE DRAWINGS WILL BE PRESUMED TO BE INCLUDED. J. ALL CONTRACTORS INVOLVED IN THIS WORK SHALL CARRY PROPERTY DAMAGE AND PUBLIC LIABILITY INSURANCE AS REQUIRED BY OWNER & GOVERNMENTAL AGENCIES HAVING JURISDICTION AND COMPLY WITH STATUTORY REQUIREMENTS FOR DISABILITY AND WORKMEN'S COMPENSATION. THEY WILL COMPLY WITH ALL RULES AND REGULATIONS DICTATED BY THE OWNER AND THE CONDITIONS OF THE JOB. INSURANCE SHALL PROTECT THE OWNER, THE TENANT, ARCHITECT AND OTHER GROUP(S) TO BE NAMED FROM LIABILITY TO THE CONTRACTOR'S NEGLIGENCE. K. THE AIA STANDARD DOCUMENT A201 SHALL BE MADE PART OF THE GENERAL CONDITIONS. L. ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS; LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE DESIGNER. DO NOT SCALE DIMENSIONS ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, BACKER BOARD, MASONRY/CONCRETE WALLS, OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE. M. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. N. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER THEIR EMPLOY. O. THE GENERAL CONTRACTOR SHALL SUPPLY, PRIOR TO THE COMMENCEMENT OF WORK, A LIST OF ALL SUBCONTRACTORS TO ARCHITECT. THE NAME OF THE PRINCIPAL CONTACT, THE ADDRESS AND PHONE NUMBER OF EACH SUBCONTRACTOR SHALL BE INCLUDED ON THE LIST. P. THE GENERAL CONTRACTOR SHALL FURNISH SAMPLES TO ARCHITECT/INTERIOR DESIGNER OF ALL MATERIALS, TOGETHER WITH FINISHES, INTENDED FOR USE IN THE WORK BEFORE THE COMMENCEMENT/ ORDER OF THE SPECIFIED WORK. Q. ANY INFORMATION REQUIRED BY CONTRACTORS THAT IS NOT SHOWN ON THE DRAWINGS OR CONTAINED IN OTHER CONTRACT DOCUMENTS SHALL BE REQUESTED BY THE GENERAL CONTRACTOR FROM ARCHITECT/INTERIOR DESIGNER. R. A REPRESENTATIVE OF THE GENERAL CONTRACTOR AUTHORIZED TO DISCUSS THE WORK AND RECEIVE INFORMATION FROM ARCHITECT SHALL BE AVAILABLE AT ALL TIMES THAT WORK IS IN PROGRESS. S. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CUT SHEETS TO ARCHITECT/INTERIOR DESIGNER FOR APPROVAL ON ALL ITEMS INCLUDING BUT NOT LIMITED TO MILLWORK, LIGHTING, FINISH MATERIALS, PLUMBING FIXTURES AND ACCESSORIES PRIOR TO ORDER. SHOP DRAWINGS SHALL SHOW ALL DIMENSIONS AND CONDITIONS. T. CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THE SUBMITTAL HAS BEEN REVIEWED, APPROVED, AND THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED. U. ALL CONTRACTORS INVOLVED IN THIS PROJECT SHALL REVIEW ALL DRAWINGS INCLUDED IN THIS DRAWING SET AND SHALL COORDINATE THEIR WORK WITH OTHER TRADES ON THIS PROJECT. V. FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR PARTITIONS, UNLESS NOTED OTHERWISE. W. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. ALL BLOCKING MUST MEET ALL APPLICABLE FIRE CODES. X. ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS, PREMIUM GRADE. Y. ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED BY THE FACILITY WITH THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION. COORDINATE FINAL FIRE EXTINGUISHER LOCATIONS WITH PHANOMEN/design PRIOR TO ROUGH-IN. STYLE TO BE SEMI-RECESSED, HINGED DOOR WITH GLASS. SUBMIT CUT-SHEET TO PHANOMEN/design FOR APPROVAL. Z. CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE WORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING WORK ADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE DAMAGE. GREAT CARE SHALL BE EXERCISED TO ASSURE THAT THE BUILDING SHALL BE PROTECTED FROM DAMAGE THAT COULD OCCUR BECAUSE OF THIS WORK. ANY DAMAGES CAUSED BY THIS WORK OR ACCIDENTS SHALL BE REPAIRED, REPLACED OR PATCHED TO THE SATISFACTION OF ARCHITECT AND THE OWNER. CONTRACTORS SHALL BEAR FINANCIAL RESPONSIBILITY FOR SUCH DAMAGE AND ANY WORK UNDERTAKEN TO CORRECT IT. AA. THE CONTRACTORS SHALL EXERCISE GREAT CARE IN PROTECTION FROM DAMAGE ALL MATERIALS EXISTING ON THE JOB AND SHALL MAINTAIN PROTECTION FOR ALL TRAFFIC AREAS OF THE BUILDING TO BE USED DURING THE EXECUTION OF WORK RELATING TO THIS CONTRACT WITH THE UNDERSTANDING THAT THE CONTRACTOR'S WILL RECTIFY ANY DAMAGE ATTRIBUTABLE TO THEIR OPERATION. AB. CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE STORED IN A LOCATION APPROVED BY THE OWNER. AC. ALL PLUMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITH INTERIOR ELEVATIONS PRIOR TO ROUGH-IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH PHANOMEN/design. AD. GYPSUM BOARD SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS AS PER MANUFACTURERS REQUIREMENTS AND INDUSTRY STANDARDS. AE. ALL GYPSUM BOARD SURFACES ARE TO BE FINISHED SMOOTH. GYPSUM ASSOCIATION GA-214-96 LEVEL 4 FINISH, WITH THE FOLLOWING ADDITION; ANY READILY VISIBLE IMPERFECTIONS IN GYPSUM BOARD SURFACE SHALL BE COATED WITH JOINT COMPOUND AND/OR SKIM-COATED AS REQUIRED. AF. SCRIBE GYPSUM BOARD OF WALL AND PARTITIONS TO IRREGULARITIES OF DECK ABOVE. SEAL TIGHTLY AROUND ANY PARTITIONS. AG.EACH TRADE SHALL BE HELD RESPONSIBLE FOR KNOWLEDGE OF THE GENERAL NOTES INCLUDED THROUGHOUT THE CONTRACT DOCUMENTS AND THE APPLICABLE BUILDING CODES. AH. THE HVAC, PLUMBING AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. SHOULD THERE BE ANY DISCREPANCY BETWEEN THE VARIOUS DRAWINGS, IT SHALL BE BROUGHT TO THE DESIGNER AND ENGINEERS ATTENTION FOR CLARIFICATION. AI. CONTRACTOR MUST VERIFY AND COORDINATE ALL OPERATIONAL REQUIREMENTS AND CLEARANCE DIMENSIONS OF PROJECT COMPONENTS; INCLUDING CONTRACTOR SUPPLIED AND OWNER SUPPLIED ITEMS. AJ. CONTRACTOR SHALL ITEMIZE ALL COSTS AND SCOPE OF WORK REGARDING ANY CHANGE ORDER. THIS INFORMATION MUST BE PRESENTED TO THE OWNER FOR APPROVAL PRIOR TO ANY WORK BEING EXECUTED. AK. ALL LIGHT FIXTURES THAT COME INTO CONTACT WITH BUILDING INSULATION MUST BE IC RATED. ALL LIGHT FIXTURES SHALL MEET ALL APPLICABLE CODES FROM NATIONAL ELECTRIC CODE (NEC) TO THE INTERNATIONAL ENERGY CODE (IEC). CONTRACTOR IS TO VERIFY CODE COMPLIANCE OF ALL LIGHT FIXTURES. AL. METAL STUD CONTRACTOR IS RESPONSIBLE FOR GAUGING AND RELATED ENGINEERING OF METAL STUD FRAMED WALLS UNLESS NOTED OTHERWISE ON ENGINEERING DRAWINGS. AM.THESE PLANS ARE INTENDED FOR "GUIDELINE" BID AND CONSTRUCTION PURPOSES ONLY AND DO NOT INCLUDE DETAILS AND METHODS OF CONSTRUCTION FOR ALL AREAS. SUBSTITUTIONS OF MATERIALS AND METHODS MAY BE PROVIDED, UPON APPROVAL OF OWNER AND DESIGNER. AN. THE PROJECT TEAM, AS LISTED, CANNOT GUARANTEE AGAINST HUMAN ERROR, OMISSIONS OR INACCURACIES CONTAINED WITHIN THESE DOCUMENTS. GENERAL CONTRACTOR IS RESPONSIBLE FOR COMMUNICATING ALL QUESTIONS AND CONCERNS TO THE PROJECT TEAM TO SEEK CLARIFICATION AND/OR SOLUTIONS PRIOR TO THE COMMENCEMENT OF THE SPECIFIED WORK. AO.ALL CONTRACTORS AND SUPPLIERS SHALL BEFORE COMMENCING WORK, REVIEW ALL PLANS AND SPECIFICATIONS AND VERIFY ALL DIMENSIONS AND DETAILS FOR THEIR WORK AND REPORT ANY DISCREPANCIES OR VARIATIONS TO THE DESIGNER PRIOR TO FINAL BID, ORDER/FABRICATION, CONSTRUCTION AND INSTALLATION OF ANY MATERIAL. THE GENERAL CONTRACTOR SHALL EXAMINE ALL ADJOINING WORK OR AREAS UPON WHICH THE PERFORMANCE OF THEIR WORK IS IN ANY WAY DEPENDENT. AP. ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY IN EVERY RESPECT UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS PER THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS UNLESS OTHERWISE NOTED. AQ.ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT. AR. SEE COVER SHEET GENERAL NOTES FOR CODE COMPLIANCE. AS. THE GENERAL CONTRACTOR SHALL KEEP SUFFICIENT WORKMEN ON THE JOB SITE AT ALL TIMES TO PERFORM THE WORK IN THE MOST EXPEDITIOUS MANNER CONSISTENT WITH GOOD WORKMANSHIP, GOOD BUSINESS PRACTICE AND THE BEST INTERESTS OF THE OWNER. AT. EACH TRADE WILL BE EXPECTED TO PROCEED IN A FASHION THAT WILL NOT DELAY OR DETAIN THE TRADES FOLLOWING THEM. AU. THE CONTRACTORS SHALL NOT PROCEED WITH ANY ADDITIONAL WORK OR CHANGES FOR WHICH THEY EXPECT ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM OWNER. FAILURE TO OBTAIN SUCH AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION. AV. ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST DEFECTS IN DESIGN, WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR. AW.THE CONTRACTORS SHALL AT ALL TIMES KEEP THE PREMISES FREE OF THE ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR OPERATIONS. THE CONTRACTORS SHALL CONFINE THEIR OPERATIONS FOR REMOVAL TO SUCH METHODS AS MAY BE AGREEABLE WITH THE OWNER. THE PROJECT SHALL BE LEFT CLEAN AND CLEAR, TO THE SATISFACTION OF THE OWNER, AND THE DISPOSITION OF ALL SALVAGED MATERIALS IS TO BE CLEARED WITH THE OWNER PRIOR TO REMOVAL. THE PREMISES SHALL BE SWEPT CLEAN DAILY OF RELATED CONSTRUCTION DEBRIS. AX. UPON SUBSTANTIAL COMPLETION OF THE WORK, THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT TO SCHEDULE A "PUNCH LIST" WALK THROUGH IT IS INTENDED THAT THE GENERAL CONTRACTOR PROVIDE A COMPLETE JOB AND ANY OMISSIONS IN THESE NOTES OR IN THE OUTLINE OF WORK SHALL NOT BE CONSTRUED AS RELIEVING THE GENERAL CONTRACTOR OF SUCH RESPONSIBILITIES IMPLIED BY THE SCOPE OF WORK EXCEPT FOR ITEMS SPECIFICALLY NOTED. AY. SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASON, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE CONTRACT. AZ. THE GENERAL CONTRACTOR SHALL HAVE A COPY OF THE LATEST SET OF CONTRACT DOCUMENTS ON THE JOB SITE AT ALL TIMES FOR REVIEW BY ARCHITECT. ALL DRAWINGS AND CONSTRUCTION NOTES ARE COMPLIMENTARY AND WHAT IS CALLED FOR BY ONE SHALL BE BINDING AS IF CALLED FOR BY ALL. BA. COMPLETE RECORD DOCUMENTS TO BE MAINTAINED SEPARATELY FROM THE FIELD SET. THE RECORD SET SHALL HAVE ALL FIELD CHANGES DOCUMENTED AND WILL BE PROVIDED TO ARCHITECT AT THE COMPLETION OF PROJECT. PROVIDE A COPY OF THE RECORD DOCUMENTS TO THE LANDLORD. BB. THE WORK INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR, AND REASONABLY INCIDENTAL TO, THE COMPLETION IN PLACE OF ALL WORK ILLUSTRATED AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. ALL SUCH WORK IS TO BE DONE BY THE CONTRACTORS UNLESS OTHERWISE NOTED. BC. THE GENERAL CONTRACTOR SHALL SUBMIT CONFIRMATIONS WITH DELIVERY DATES OF ORDERS FOR MATERIALS AND EQUIPMENT ON ANY LONG LEAD-TIME ITEMS AT THE COMMENCEMENT OF PROJECT. BD. CONTRACTOR TO INCLUDE PRICING FOR HOOD DUCT DRAWING THROUGH THE CHOSEN HOOD CONTRACTOR, UNLESS OTHERWISE DISCUSSED. BE. SIGNAGE REQUIRES SEPARATE REVIEW, PERMITS, AND FEES. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING SUCH PERMITS, UNLESS OTHERWISE DISCUSSED. OWNER SHALL SUBMIT BUILDING SIGNAGAE TO CITY FOR APPROVAL PRIOR TO INSTALLATION. BF. FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL BE PROVIDED PER NFPA NO.13. APPROVALS TO BE OBTAINED FROM LOCAL FIRE MARSHAL. CONTRACTOR TO SUBMIT ALL REQUIRED DRAWINGS AND INFORMATION TO FIRE MARSHAL AND AUTHORITY FOR APPROVAL PRIOR TO COMMENCEMENT OF ANY RELATED WORK. OBTAIN APPROVAL OF COMPLETED SYSTEMS PRIOR TO FINAL ACCEPTANCE. 09/23/21 D DAB CE POS/ RESETPOS HOST30x48 30x48 30x48 POS/ RESET RESET COOLER COOLER HOOD EP EP POS/ RESETPOS HOST30x48 30x48 30x48 POS/ RESET RESET HOOD EP EP LIFE SAFETY PLAN A002 'A-2' OCCUPANCY INTERIOR CONSTRUCTION ONLY, SPRINKLERED APPLICABLE CODES BUILDING CODE: 2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE: 675 IAC 13-2.6) PLUMBING CODE: 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE: 675 IAC 16-1.4) ELECTRICAL CODE: 2009 INDIANA ELECTRICAL CODE (2008 NFPA-70: 675 IAC 17-1.8) MECHANICAL CODE: 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE: 675 IAC 18-1.6) FIRE / LIFE SAFETY CODE: 2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE: 675 IAC 22-2.5) ACCESSIBILITY CODE: 2008 INDIANA BUILDING CODE CHAPER 11 - ACCESSIBILITY (675 IAC 13-2.5-12 CHAPTER 11) ENERGY CODE: 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1, 2007 EDITION: 675 IAC 19-4) ELEVATOR CODE: 2011 INDIANA ELEVATOR SAFETY CODE (ANSI/ASME A17.1, 2007 EDITION: 675 IAC 21-3) GAS CODE: 2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE: 675 IAC 25-3) EXIT DIRECTION ARROW ROOM NAME OCCUPANT CAPACITY COMMON PATH OF TRAVEL RM NAME ## ## SF/ ## LEGEND: EXIT AREA / LOAD FACTOR EMERGENCY LIGHT WALL MOUNTED EXIT SIGN CEILING MOUNTED EXIT SIGN CEILING MOUNTED DIRECTIONAL EXIT SIGN FIRE EXTINGUISHER (ON HOOK) UNDER CABINET OR ON WALL F.E.C.FIRE EXTINGUISHER CABINET PROJECT SCOPE: Project includes interior build-out of a new restaurant project on the ground floor of a existing shell building. The existing shell of the building was separately submitted and is outside of the scope of these documents. BUILDING DESCRIPTION: TYPE 'A-2' OCCUPANCY Refer to shell drawing set for additional information. Project Number 395544. CONSTRUCTION TYPE CLASSIFICATION: TYPE I-A - SPRINKLERED FIRE RESISTANCE RATING REQUIREMENTS: STRUCTURAL FRAME: 3HR (EXISTING) BEARING WALLS: 3HR (EXISTING) NONBEARING WALLS & PARTITIONS: ANY MATERIAL MIXED OCCUPANCY FIRE SEPARATION: 1HR (EXISTING) OCCUPANCY: ACTUAL FLOOR AREA: 5,626 SF TOTAL 'A-2' OCCUPANCY (DINING): 2,217 SF / 15 = 147.82 PRIVATE DINING: 683.3 SF / 15 = 45.55 KITCHEN OCCUPANCY: 1,376.5 SF / 200 = 6.88 OFFICE 62.7 SF / 100 =.63 UTILITY/TRASH 159.3 SF RESTROOMS/CIRC: 1,127.2 SF TOTAL MAX. OCCUPANCY: 200.88 OR 201 OCCUPANTS (CALCULATED) EXTERIOR PATIO DINING A: 672.7 SF / 15 = 44.5 OR 45 OCCUPANTS (CALCULATED) EXTERIOR PATIO DINING B: 805.7 SF / 15 = 53.7 OR 54 OCCUPANTS (CALCULATED) EXIT ANALYSIS: 5,626 SF (TYPE 'A-2' OCCUPANCY) WITH A TOTAL OCCUPANT LOAD OF 201, PER IBC TABLE 1014.1, SHALL HAVE A MINIMUM OF TWO (2) EXITS. THREE (3) EXITS HAVE BEEN PROVIDED. COMMON PATH OF TRAVEL: 75 FT MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 250 FT PATIO A: 673 SF (TYPE 'A-2' OCCUPANCY) WITH A TOTAL OCCUPANT LOAD OF 45, PER IBC TABLE 1014.1, SHALL HAVE A MINIMUM OF ONE (1) EXITS. ONE (1) EXITS HAVE BEEN PROVIDED. PATIO B: 806 SF (TYPE 'A-2' OCCUPANCY) WITH A TOTAL OCCUPANT LOAD OF 54, PER IBC TABLE 1014.1, SHALL HAVE A MINIMUM OF TWO (2) EXITS. TWO (2) EXITS HAVE BEEN PROVIDED. EGRESS ANALYSIS: INTERIOR: 201 OCCUPANTS X .15 PER OCCUPANT = 30.1" REQUIRED 144" PROVIDED PATIO A: 45 PATIO OCCUPANTS + 100 INTERIOR OCCUPANTS] x .15" PER OCCUPANT = 29.25" REQUIRED 36" PROVIDED PATIO B: 54 PATIO OCCUPANTS + 46 INTERIOR OCCUPANTS] x .15" PER OCCUPANT = 29.25" REQUIRED 108" PROVIDED RESTROOM ANALYSIS: TOTAL ANTICIPATED OCCUPANCY : 260 INTERIOR SEATING: 162 PATIO EXTERIOR ANTICIPATED OCCUPANCY: 98 STAFF : 25 TOTAL ANTICIPATED OCCUPANTS: 285 TOTAL OCCUPANTS (ANTICIPATED) ANTICIPATED MALE OCCUPANCY < 143 ANTICIPATED FEMALE OCCUPANCY < 143 WATER CLOSETS REQUIRED = 2 MALE/ 2 FEMALE (1 + 1 URINAL MALE/ 2 FEMALE PROVIDED) LAVATORIES REQUIRED 1 MALE/1 FEMALE (1 EACH PROVIDED)AS NOTEDSCALE: NO SCALE OCCUPANCY PLAN2 Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032N S W E 0 5 10 20 40 N S W E SCALE: 1/8"=1'-0" LIFE SAFETY PLAN1 B(USINESS) PHYSIQUE 57 ANTICIPATED A-3 OCCUPANCY ELEC. MECH. PARKING GARAGE P-1 VACANT ANTICIPATED A-2 OCCUPANCY R2R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 OFFICE 62.7 SF/ 100 1 KITCHEN 1,376.5 SF/200 6.9 PATIO DINING B 806 SF/ 15 53.73 PATIO DINING A 672.7 SF/ 15 44.8 EXIT TRASH ROOM 159 SF PROJECT LOCATION A-2 OCCUPANCY 89 ' -7 "OVERA L L D IAGONA L DIS TANC E COMMON PATH OF TRAVEL 72'-8"77'-9"OVERALL DIAGONAL DISTANCE46'-2"DISTANCE BETWEEN EXITSF.E.C.N.I.C. F.E. F.E. DINING 2,217 SF/ 15 147.82 CIRC. 98 SF RR/CIRC. 461 SF PRIVATE DINING 683.3 SF/ 15 45.5 WALL MOUNTED EXIT SIGN WITH EMERGENCY LIGHTS NEW EGRESS WALL SCONCE FIXTURE EXIT EXIT EXIT EXIT 34' -7" DIST A N C E BETW E E N EXI T S EXIT 1-HR 1-HR FIRE RATED CONSTRUCTION REFER TO SHELL PACKAGE 1-HR 1-HREXISTING 1-HREXISTING 1-HREXISTING 1-HR EXISTING 1-HR 09/23/21 20 GA - 3 5/8" METAL STUDS @ 16" O.C. SCHEDULED CEILING SYSTEM 3 5/8" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) DECK 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCALE: 1/2"=1'-0" WT-1 WALL TYPE1 SCHEDULED BASE SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLANVARIESSEE REFLECTED CEILING PLAN5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. SCHEDULED CEILING SYSTEM 3 5/8" METAL RUNNER SCALE: 1/2"=1'-0" WT-3 WALL TYPE3 CONFIRM WITHKITCHEN SUPPLIER5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 6" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER (BRACE AS REQUIRED) STAINLESS STEEL PASS THROUGH WINDOW BY KITCHEN EQUIPMENT VENDOR SCALE: 1/2"=1'-0" WT-4 WALL TYPE4 WT-1A - WALL TYPE AS SHOWN WT-1B - WALL TYPE WITHOUT INSULATION SCALE: 1/2"=1'-0" WT-2 WALL TYPE2 WT-2A - WALL TYPE AS SHOWN WT-2B - WALL TYPE WITHOUT INSULATION 1/2" = 1'-0"ARCHITECTURAL WALL TYPES A010CONFIRM FINAL HEIGHT WITHCOUNTERTOPINSTALLATION PRIORTO ROUGH IN5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 18 GA - 6" METAL STUDS @ 16" O.C. 6" METAL RUNNER (BRACE AS REQUIRED) COUNTERTOP. REFER TO INTERIOR SECTIONS/ELEVATIONS FOR FINAL DESIGN WOOD BLOCKING AS REQUIRED GENERAL WALL TYPE NOTES 1. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT TOILET ROOMS, KITCHENS, JANITORS CLOSETS, SINKS, OTHER SIMILAR LOCATIONS, AND ANY WALL WHICH IS TO RECEIVE A TILE FINISH. IF TWO LAYERS OF GYPSUM BOARD ARE INDICATED IN A WALL ASSEMBLY ONLY THE OUTSIDE LAYER NEED BE REPLACED WITH CEMENT BOARD. 2. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT KITCHEN AND SIMILAR AREAS WHICH IS TO RECEIVE STAINLESS STEEL FINISH. 3. METAL STUD CONTRACTOR TO DETERMINE GAUGE AND RELATED ENGINEERING OF METAL STUDS, TRACKS, BRIDGING, BLOCKING, KICKERS, FURRING, AND OTHER METAL FRAMING COMPONENTS. 4. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES. 5. WALL TYPES DO NOT INDICATE WALL FINISH MATERIALS IN ALL CASES. SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR ADDITIONAL FINISH INFORMATION. 6. PROVIDE ADDITIONAL LAYERS OF GYPSUM BOARD, BLOCKING, OR FRAMING AS NEEDED TO ACCOUNT FOR ALIGNING OF WALL TYPES OR FLUSH CONDITIONS. 7. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE. REFER TO WALL TYPES. 8. VERIFY FIRE RATINGS OF WALLS WITH FIRE RATING TABLE, LIFE SAFETY PLANS, AND OTHER NOTATIONS THROUGHOUT THE DRAWING SET. 9. PROVIDE IN-WALL BLOCKING FOR TENANT PROVIDED FF&E ITEMS. COORDINATE WITH TENANT. 10. REFER TO FINISH PLAN TO COORDINATE AREAS OF OF PLYWOOD SHEATHING REQUIRED FOR WOOD WALL PANELING 11. REFER TO ARCHITECTURAL FLOOR PLAN TO COORDINATE AREAS OF PLYWOOD SHEATHING REQUIRED FOR BLOCKING AND MOUNTING OF EQUIPMENT. Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 4603220 GA - 6" METAL STUDS @ 16" O.C. 6" METAL RUNNER DECK 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCALE: 1/2"=1'-0" WT-5 WALL TYPE5 SCHEDULED BASE SCHEDULED FLOORING SCALE: 1/2"=1'-0" WT-6 WALL TYPE6 2 LAYERS OF 2" WOOD BLOCKING TOP CAP AS SCHEDULED STANDARD 8X16 CMU BLOCK WALL. GROUT AND REINFORCE AS REQUIRED SCHEDULED FLOORING FIREPROOF SEALANT AS REQUIRED (NOT REQUIRED IF SPRINKLERED) SCALE: 1/2"=1'-0" WT-7 WALL TYPE7 DECK SCHEDULED CEILING SYSTEM 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) SCALE: 1/2"=1'-0" WT-8 WALL TYPE8 DECK SCHEDULED CEILING SYSTEM 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 3 5/8" METAL RUNNER SCALE: 1/2"=1'-0" WT-9 WALL TYPE9 VARIESSEE REFLECTED CEILING PLANVARIESSEE INTERIOR ELEVATIONSFINISH WOOD TOP CAP (1/4" PROUD OF WALL) 5/8" GYP. BOARD SHEATHING ON ONE SIDE (CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 6" METAL STUDS @ 16" O.C. 6" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) SCALE: 1/2"=1'-0" WT-10 WALL TYPE10 DECK SCHEDULED CEILING SYSTEM VARIESSEE REFLECTED CEILING PLANCONFIRM WITH TENANT5/8" XP DRYWALL & FRP (CAULKED JOINTS & TRIM) ON COOLER SIDE AND VAPOR BARRIER UNDER 5/8" GYP. BOARD (OR DUROCK AT TILE LOCATIONS) TO FINISHED SIDE(S) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER CONFIRM WITHKITCHEN SUPPLIER3"x3"x8" L CLIP ANGLES AT 4'-0" O.C. , MECH. FASTENED TO UNDERSIDE OF SLAB, BOTH SIDES OF WALL EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES 6" R19 UNFACED INSULATION IN STUD CAVITIES 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES DOWEL AS REQUIRED VERTICAL REINFORCEMENT AS REQUIRED COORDINATE REQUIREMENTS WITH TENANT 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 2 1/2" METAL STUDS @ 16" O.C. 2 1/2" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) SCALE: 1/2"=1'-0" WT-11 WALL TYPE11 DECK SCHEDULED CEILING SYSTEM VARIESSEE REFLECTED CEILING PLANEXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES WT-11A - WALL TYPE AS SHOWN WT-11B - WALL TYPE TERMINATED AT BOTTOM OF SCHEDULED CEILING 09/23/21 CO2 OIL TANK36"X72"TV TVPOS/ RESETPOS HOST TV TVSUPPLYMAKE-UP POS/ RESET RESET EP EP ARCHITECTURAL FLOOR PLAN & DOOR SCHEDULE A100 SCALE: 1/8"=1'-0" FLOOR PLAN1 KEYED ARCHITECTURAL NOTES# 1. INSTALL 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS AT ALL EXISTING PERIMETER SHELL WALLS WITH EXPOSED METAL STUDS. REFER TO FINISH PLAN AND INTERIOR ELEVATIONS FOR FINISHES. GENERAL ARCHITECTURAL NOTES ALIGN FINISHED FACES. AT KITCHEN & BAR: CONFIRM LOCATIONS AND REQUIREMENTS WITH KITCHEN EQUIPMENT VENDOR AND TENANT PRIOR TO INSTALLATION OF IN WALL BLOCKING AND WATER PROOFING AT HAND SINKS AT STAINLESS STEEL. REFER TO KITCHEN EQUIPMENT PLANS BY K.E.C. DECORATIVE METAL SCREEN PROVIDED AND INSTALLED BY PHANOMEN. CONTRACTOR TO PROVIDE AND INSTALL NEW GARAGE DOOR WITH VERTICAL TRACK. MODIFY EXISTING OPENING AS REQUIRED. CONFIRM DIMENSIONS IN FIELD. CONFIRM GARAGE DOOR SPECIFICATIONS WITH TENANT AND PHANOMEN/design PRIOR TO ORDERING. PROVIDE BLOCKING AS REQUIRED FOR DOOR HARDWARE. EXISTING CONCRETE COLUMN TO REMAIN EXPOSED. INSTALL WATERPROOFING MEMBRANE 12" UP WALL @ FLOOR AROUND PERIMETER OF ROOM AS REQUIRED. COORDINATE WITH DESIGNER. NEW P.O.S./ RESET STATION. PROVIDE DATA ACCESS FOR TWO STATIONS. CONFIRM ELECTRICAL AND DATA WITH FINAL DESIGN. CONTACT MILLWORKER FOR PRICING AND INSTALLATION. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED FIXTURES, COUNTERS, AND TV. REFER TO INTERIOR ELEVATIONS FOR DETAILS. CASED OPENING, TRIM TO MATCH INTERIOR DOORS. REFER TO FRAME DETAIL C1/A100 AND INTERIOR ELEVATIONS. CONTRACTOR TO PROVIDE AND INSTALL NEW FIRE EXTINGUISHER ON HOOK. PROVIDE SIGN ABOVE EXTINGUISHER. VERIFY FIRE EXTINGUISHER IS COMPLIANT FOR KITCHEN USE. CONTRACTOR TO PROVIDE AND INSTALL NEW FULLY RECESSED FIRE EXTINGUISHER CABINET. MOUNT PER ADA GUIDELINES, FINISH: TBD. CONTRACTOR TO PROVIDE AND INSTALL NEW FIRE EXTINGUISHER ON HOOK BELOW BAR COUNTERTOP. PROVIDE ELECTRICAL AS REQUIRED FOR LIT ART FEATURE; COORDINATE WITH DESIGNER. CONTRACTOR TO PROVIDE 7" HIGH PLATFORM FOR BOOTH SEATING. REFER TO INTERIOR ELEVATIONS FOR DETAILS. PROVIDE ELECTRICAL OUTLETS IN OIL RUBBED BRONZE FINISH TO FRONT OF PHANOMEN PROVIDED BOOTHS. COORDINATE WITH DESIGNER. REFER TO INTERIOR ELEVATIONS FOR DETAILS. RECEPTION/HOST STATION BY PHANOMEN. COORDINATE ELECTRICAL WITH FINAL DESIGN, REFER TO INTERIOR ELEVATIONS FOR DETAILS. PROVIDE NEW WATER SPIGOT AT THIS LOCATION, CONFIRM LOCATION WITH OWNER. INSTALL 24" W x 15" DEEP BENCH IN NOOK AT 18" H. REFER TO INTERIOR ELEVATION FOR DETAILS. WALL TYPE SYMBOLS LEGEND EXISTING WALL CONSTRUCTION TO REMAIN NEW INTERIOR WALL CONSTRUCTION, REFERENCE WALL TYPE FOR FURTHER INFORMATION NEW PARTIAL HEIGHT WALL CONSTRUCTION, REFERENCE WALL TYPE FOR FURTHER INFORMATION SCALE: 1/4" = 1'-0"WT# WALL TYPE TAG. REFER TO A010 TYPICAL WALL TYPES FOR DETAILS. N S W E X WINDOW TAG. REFER TO A201 DOOR AND WINDOW SCHEDULE FOR DETAILS. 7 A200 Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032ALL DOOR SIZE DIMENSIONS GIVEN ARE APPROXIMATE. DOOR SUPPLIER/INSTALLER SHALL VERIFY EXACT REQUIREMENTS. 3. ALL HARDWARE NOTED IN REMARKS1. 103 DOOR SCHEDULE THK.HT. WIDTH DIMENSIONS NO. DOOR TYPE MAT'L. FINISH FRAME REMARKS PR - PRIVACY P - PASSAGE C - CLOSER LS - LOCKSET PU - PUSH/PULL PA - PANIC CL - CATCH LATCH S - STOP DB - DEADBOLT KS - KICK STOP EXISTING -- WINDOW TYPES SCALE: 1/4" = 1'-0" D2 3 PANEL W/ GLASSKIT + LITE FRAME TYPES SCALE: 1/4" = 1'-0" F1 HOLLOW METAL W/CASING PER SCHEDULE PER SCHEDULE9"4 12" BASE PER SCHEDULE C2 A100 C1 - SECTION WALL CASED OPENING DETAIL PUSH/PULL HARDWARE PER SCHEDULE PER ELEVATIONDOOR SCHEDULE GENERAL NOTES: A. METAL DOOR FRAMES TO BE PRE-FINISHED TIMELY BLACK (SC103) OR SIMILAR. PROVIDE FINISH SAMPLE TO DESIGNER PRIOR TO ORDERING. B. UNDERCUT DOORS AS REQUIRED BY FLOOR FINISH. C. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAMES AND ADJACENT WALL MATERIAL. D. SPOT GROUT NEW HOLLOW METAL DOOR GRAMES IN GYPSUM BOARD WALL CONSTRUCTION. E. COUNTERSINK AND FILL FINISH NAIL HOLES IN WOOD CASING TRIM. FINISH COLOR TO MATCH WOOD CASING. F. DOOR HINGES AND ACCESSORY HARDWARE TO MATCH HARDWARE FINISH. G. CONTRACTOR TO PROVIDE DOOR AND HARDWARE SUBMITTAL TO PHANOMEN/design FOR REVIEW PRIOR TO ORDERING DOORS. CONTRACTOR TO VERIFY LEAD TIMES. H. CONTRACTOR TO COORDINATE LOCKSETS WITH MATT DODSON WITH ROBERTS GLASS FOR ORDERING REMOVABLE CORES AND KEYING. 101B 3'-0" 10'-0" 1-3/4" 101A 104 3'-0" 8'-0" 1-3/4" 3'-0" 8'-0" 1-3/4" 6'-0" MATCH EXISTING -- -- EXISTING EXISTING -- 105 107 WD WD WD AL F4 EXISTING F5 F5 F2 KICKPLATE D3 3 PANEL W/ GLASSKIT + LITE PUSH/PULL HARWARE PER SCHEDULE PER ELEVATIONG-2 GLASS G-1 GLASS A102 1 6 A200 4 A201 5 A201 2 A201 2 A200 5 A200 4 A200 3 A201 3 A203 1 A203 2 A202 3 A203 4 A203 107 VEST. 101 ENTRY 102 DINING 103 WOMEN'S RESTROOM 104 MEN'S RESTROOM 105 BAR 106 DINING 107 PRIVATE DINING 108 KITCHEN 109 OFFICE 111 108A108C101B104105 111 110 109A 101A103108A 108C 109A 110 111 NAME ROOM VEST. VEST. DINING RESTROOM RESTROOM DINING PRIVATE DINING PRIVATE DINING KITCHEN TRASH OFFICE EXISTING 7'-2"10'-8"1 A202 8'-9"9'-1" 11'-6"5'-0" 2'-6"6'-5" 3'-0"1'-10" 7'-2" 8'-3" 8'-0"7'-4" 5'-0"4'-2" 2'-0"1'-0"3 A200 8'-0" 25'-3"3'-0" METAL METAL WD WD D3 D3 F1 F1 PT-X PT-X EXISTING PT-X MATCH EXISTING -- PT-X -- -- -- EXISTING EXISTING EXISTING -- -- -- PT-X PT-X 108B 108B PRIVATE DINING WT1A WT1AWT1A WT1BWT1B WT2BWT1A WT1B WT1AWT1A WT1AWT2BWT2BWT2BTYP.WT1A WT1A WT1AWT1A WT3WT3 11" WT4 WT5 WT7WT7 WT7WT10 WT10 WT9WT9WT8 WT1B WT8 WT8 C, PU, S, KS 6, 7 6, 7 C, PU, S, KS D2 3'-0" D4 MATCH STYLE OF EXISTING EXTERIOR DOORS D4 F2 MATCH EXISTING STOREFRONT VERIFY IN FIELD1 1 1 1 1 2 2 3 3 3 4 4 4 7 7 2 7 2 7 7 7 8 8 8 3 9 10 11 12 13 14 32 16 17 18 18 19 20 21 21 21 22 23 23 10'-0" 7'-0" 7'-0" 7'-0" 3'-0" 1-3/4" TRASH 110 D5 MATCH BUILDING STANDARD DOORS PER SCHEDULE PER SCHEDULEPER SCHEDULEF3 HOLLOW METAL PER SCHEDULE PER SCHEDULED6 PANIC DEVICE PER SCHEDULE PER SCHEDULED6 MATCH BUILDING STANDARD DOORS D5 F3 F3 11" TYP. 9 9 9 9 9 9 9 6'-0" 5'-9" 1-3/4" 1-3/4" -- 1-3/4" 1-3/4" D8 D7 WD --SEE REMARK PER SCHEDULE PER SCHEDULE10, 13 D7 3 PANEL DOUBLE BY PASSING DOORS PULL SPEC: TBD C, DB, KS, PA LS, S PER SCHEDULE DOOR TYPES SCALE: 1/4" = 1'-0" D8 3 PANEL W/ GLASSKIT + LITE DOUBLE DOORS LEVER HARDWARE BY PHANOMEN PER SCHEDULE PER SCHEDULEKICKPLATE G-2 GLASS C, S, KS 3,12, 11 2, 6 2, 8, 9 3, 12 3, 12 3, 7 3, 12 C, PU C, PU, PA -- -- -- TEMPERED GLASS 4, 14 25 1"X4" WOOD MOLDING WITH 412" W X 9" H X 1 1 4" D PLINTH BASE WINDOWS PROVIDED AND INSTALLED BY CONTRACTOR. REFERENCE INTERIOR ELEVATIONS FOR WINDOW PLACEMENT AND DETAILS. ATYPE VESTIBULE 3'-1112" V.I.F. 1" APPLIED MUNTIN TO MATCH FRAME WOOD FRAME MATCH C1 CASED OPENING GL-1 EQ.EQ. MATCH DOOR FRAME HEIGHT3'-4" EQ.EQ.C2 - SECTION DOOR CASING DETAIL AT METAL FRAMES KICKPLATE HOLLOW METAL W/CASING A 0 5 10 20 40 STAINED GLASS; DESIGN TBD STAINED GLASS; DESGIN TBD 26 27 10'-0" 1 A200 TV LOCATION, COORDINATE MOUNTING HEIGHT AND POWER AND DATA REQUIREMENTS WITH TENANT. PROVIDE SURFACE MOUNTED GALVANIZED METAL CONDUIT WHERE TV IS TO BE INSTALLED ON EXPOSED CONCRETE. NEW COOLER CONSTRUCTION, REFER TO DETAIL 6/A010 FOR WALL CONSTRUCTION INFORMATION. COORDINATE ADDITIONAL REQUIREMENTS WITH TENANT. AT KITCHEN AND BAR AREA, FLOORING TO BE SEALED CONCRETE WITH SMOOTH FINISH. PROVIDE SLIP RESISTANT COAT AS REQUIRED, COORDINATE WITH TENANT. PROVIDE (3) RECESSED OUTLETS FOR PHANOMEN PROVIDED LIT ARTWORK. COORDINATE WITH PHANOMEN FOR EXACT LOCATIONS. PLANTERS TO BE PROPERLY FASTENED TO SIDEWALK, COORDINATE WITH PHANOMEN. PROVIDE 7" HIGH METAL FRAMED PLATFORM . 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 LS, KS, PA 18 28 29 28 29 29 WT1B 4'-9"KICKPLATE ON BOTH SIDES KICKPLATE ON BOTH SIDES METAL LOUVRE PAINTED TO MATCH DOOR. VERIFY WITH LANDLORD 29 29 30 30 30 12'-4" 12'-0" F4 HOLLOW METAL W/CASING PER SCHEDULE PER SCHEDULE 9" 4 12" BASE PER SCHEDULE C2 A100 1"X4" WOOD MOLDING WITH 412" W X 9" H X 1 14" D PLINTH BASE 1 A201 8 A201 DOOR DESIGN TBD DOOR DESIGN TBD F5 HOLLOW METAL W/CASING PER SCHEDULE PER SCHEDULE 9"4 12" BASE PER SCHEDULE C2 A100 1"X4" WOOD MOLDING WITH 412" W X 9" H X 1 1 4" D PLINTH BASE G-1 GLASS BLACK METAL MUNTINS 1'-4"1'-4"23 31 32 24 26 33 31 34 31 31 31 31 31 31 34 11'-5"10'-6" 10, 13, 15 1X4 WOOD TO BE ST-2 1X4 WOOD TO BE ST-2 GYP. BOARD FLUSH METAL FRAME GYP. BOARD BLOCKING AS REQUIRED WT2B WT1BEND OF WOOD TRIM TO BE FLUSH WITH DOOR FRAME AS SHOWN 10 19'-1"4'-4" C, PU, PA C, PU, PA C, PU, PA PU A103 1 109B 109C DOOR SCHEDULE KEY NOTES: 1. NOT USED. 2. PHANOMEN PROVIDED, CONTRACTOR INSTALLED DOOR. 3. ENTRY DOOR PULLS TO BE BY PHANOMEN. 4. TYPE 1 KEYED SET TO BE CORBIN RUSSWIN CL3500 SERIES WITH INTERCHANGEABLE CORE, BLACK FINISH BSP. 5. PHANOMEN PROVIDED, CONTRACTOR INSTALLED TYPE 2 PASSAGE SET . 6. PHANOMEN PROVIDED, CONTRACTOR INSTALLED TYPE 3 PUSH PULL. 7. PHANOMEN PROVIDED, CONTRACTOR INSTALLED DOOR KICKPLATE. 8. PROVIDE WOOD CASED OPENING TO MATCH "C1" FRAME TYPE. 9. DOUBLE BY-PASS BARN DOOR, HARDWARE AND PULLS TO BE PROVIDED BY PHANOMEN AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE ADEQUATE BLOCKING IN HEADER TO CARRY WEIGHT OF BARN DOORS. 10. CONTRACTOR TO MATCH BUILDING STANDARD LOCKSETS, REMOVABLE CORE REQUIRED. 11. CONTACT MATT DODSON WITH ROBERTS GLASS AT (317) 345-2760 FOR WINDOW REMOVAL AND NEW PATIO DOOR. 12. COORDINATE LOCKING REQUIREMENTS WITH TENANT. 13. PROVIDE MINIMUM OF 3/4 HOUR FIRE RATED DOOR AS REQUIRED. 14. NEW WOOD SOLID CORE DOOR BY CONTRACTOR. 15. INSTALL 180 DEGREE PEEP HOLE IN DOOR. 16. CONTRACTOR TO INSTALL LOUISVILLE COOLER RETRO-FIT INSULATED DOOR, FRAME, AND HARDWARE. COORDINATE FINISH AND ANY ADDITIONAL REQUIREMENTS WITH TENANT. 109B KITCHEN 3'-0" 6'-8 109C KITCHEN 3'-0" 6'-8 -- -- -- -- METAL METAL TBD TBD SEE REMARKSEE REMARK 16 16 55'-0"7'-0" 8'-0" PROVIDE AND INSTALL BUILT-IN SHELF. REFER TO ELEVATION FOR DETAILS. HOLD DRYWALL AS TIGHT AS POSSIBLE TO THE COLUMN AND/OR ANY PLUMBING. SMART PERGOLA SYSTEM WITH DROP DOWNS BY TENANT. PERGOLA DRAWINGS TO BE PROVIDED BY OTHERS. PERGOLA FINISH TO BE DARK BRONZE TO MATCH EXISTING STOREFRONT. NEW EXTERIOR METAL RAILING BY PHANOMEN. INSTALL NEW CURVED WOOD PANELING, PROVIDE BLOCKING AS REQUIRED. REFER TO FINISH PLAN AND INTERIOR ELEVATIONS FOR DETAILS. PROVIDE POWER FOR PHANOMEN PROVIDED LAMP. SPECIFICATION; TBD. CONFIRM EXACT POWER REQUIREMENTS WITH PHANOMEN. INSTALL DECORATIVE ETCHED WOOD PANELING ON WALL. PROVIDE BLOCKING AS REQUIRED, REFER TO INTERIOR ELEVATIONS FOR DETAILS. COORDINATE WITH PHANOMEN/ design. FREESTANDING EAT IN COUNTER AT 42" H WITH APRON TO BE PROVIDED BY PHANOMEN/design. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED EQUIPMENT. CONFIRM LOCATION WITH TENANT. PER SCHEDULE 1. NEW 4” SLAB ON GRADE WITH 6X6-W1.4XW1.4 W.W.F. ON 10 MIL VAPOR RETARDER OVER 4” COMPACTED GRANULAR MATERIAL.  PROVIDE TYPICAL CONTROL JOINT AT APPROXIMATE 12'-0” INTERVALS.  PROVIDE CONSTRUCTION JOINTS FOR ISOLATED SLAB AT COOLER AND DELIVERY RAMP.  PROVIDE COLUMN ISOLATION JOINTS AT ALL INTERNAL COLUMN LOCATIONS.  CONTRACTOR TO PROVIDE JOINT LAYOUT PLAN FOR APPROVAL PRIOR TO CONSTRUCTION.  GENERAL SLAB ON GRADE NOTES 7 A201 2 A203 24 47° 8 UP 34 34 6 6 6 6 6 6 6 6 6 1 TYP. 34 15'-0"4 A202 09/23/21 MATER IALPRODU C TTRADE N AMEMODELNUM B ER SUPPLYMAKE-UP MATER I ALPRODU C TTRADENAMEMODE L NUMBER 36"6" 18" CL RESTROOM PLAN, ELEVATIONS & NOTES A102 SCALE: 1/2"=1'-0" INTERIOR ELEVATION10 TYPICAL RESTROOM SCALE: 1/2"=1'-0" INTERIOR ELEVATION11 TYPICAL RESTROOM SCALE: 1/2"=1'-0" INTERIOR SECTION9 TYPICAL RESTROOM SCALE: 1/4"=1'-0" INTERIOR ELEVATION2 MEN'S RESTROOM SCALE: 1/4"=1'-0" INTERIOR ELEVATION3 MEN'S RESTROOM SCALE: 1/2"=1'-0" SINK SECTION8 1. AT ALL ADA RESTROOM STALLS PROVIDE SPECIFIED GRAB BARS. REFERENCE ELEVATIONS FOR DIMENSIONS. 2. PROVIDE BLOCKING FOR ALL WALL MOUNTED GRAB BARS. 3. RESTROOMS SHALL CONFORM TO ALL HANDICAP ACCESSIBILITY REQUIREMENTS, INCLUDING THE FOLLOWING: A. ELONGATED WATER CLOSET SEAT HEIGHT: 17"-19" A.F.F.; URINAL RIM HEIGHT 17" MAX A.F.F. B. CENTER LINE OF WATER CLOSET: 18" FROM SIDE WALL C. GRAB BAR BEHIND WATER CLOSET: 36" LONG, 34" A.F.F. D. GRAB BAR AT SIDE OF WATER CLOSET: 42" LONG, 34" A.F.F. & VERTICAL GRAB BAR 18"LONG, 40" A.F.F. E. GRAB BAR DIAMETER: 1-1/4" TO 1-1/2" F. SPACE BETWEEN WALL AND GRAB BAR: 1-1/2" G. TOILET PAPER DISPENSER: 19" A.F.F., STYLE T.B.D. H. KNEE CLEARANCE AT LAV. APRON: 29" A.F.F. MIN. HT., 8" MIN. DEPTH I. LAV. DEPTH: 17" MIN. J. LAV. H.W. AND DRAIN PIPES INSULATED WHERE EXPOSED. K. LAV. RIM SURFACE 34" A.F.F. MAX. L. MIRROR - BOTTOM EDGE" MAX. 40" A.F.F. N. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS AND SHALL BE DESIGNED FOR A 250 LB. LOAD. O. LIGHT SWITCH SHALL BE MOUNTED LESS THAN: 48" A.F.F. P. DOOR HARDWARE SHALL BE "LEVER-ARM" TYPE, WHERE APPLICABLE. Q. FAUCET TO BE TOUCHLESS, REFER TO PLUMBING DRAWING FOR SPEC. ACCESSIBILITY NOTES: 1 KEYED ARCHITECTURAL NOTES# INSTALL QUARTZ LAVATORY COUNTERTOP. PROVIDE BLOCKING AND STEEL SUPPORT AS REQUIRED. REMNANT GRANITE TO BE PROVIDED BY OLYMPIA STONE. CONTACT PHANOMEN/design FOR FINAL SPEC. PROVIDE AND INSTALL NEW LAVATORY : MFG: AMERICAN STANDARD TYPE: MEZZO DROP IN BATHROOM SINK WITH 19" LENGTH AND OVERFLOW, SINGLE HOLE FINISH: WHITE NOTE: PROVIDE PIPE COVER. CONTRACTOR TO PROVIDE CUT SHEETS FOR DESIGNER AND TENANT APPROVAL PRIOR TO ORDER. 1. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING FOR ALL WALL HUNG ITEMS. 2. REFER TO PLUMBING DRAWINGS FOR LOCATION OF FLOOR DRAIN (WHERE REQUIRED). 3. IF REQUIRED BY LANDLORD, CONTRACTOR TO PROVIDE WATERPROOF MEMBRANE AT FLOOR AND UP WALLS TO 12" AFF. RESTROOM GENERAL NOTES Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032AS NOTEDSCALE: 1/4"=1'-0" INTERIOR ELEVATION4 WOMEN'S RESTROOM ACCESSORY AND FIXTURE LEGEND: 1 X 2 3 4 5 6 7 PROVIDE & INSTALL NEW FLOOR MOUNTED TANK, ADA COMPLIANT, TOILET: MFG: CONTRACTOR STANDARD TYPE: HANDS FREE FINISH: WHITE NOTE: CONTRACTOR TO PROVIDE CUT SHEETS FOR DESIGNER AND TENANT APPROVAL PRIOR TO ORDER. PROVIDE AND INSTALL NEW FAUCET: MFG: KOHLER TYPE: GEOMETRIC INSIGHT TOUCHLESS FAUCET WITH MIXER, DC-POWERED K-13466 FINISH: VS VIBRANT STAINLESS NOTE: CENTER FAUCET ON SINK PROVIDE & INSTALL NEW WALL MOUNTED, ADA COMPLIANT, URINAL: MFG: CONTRACTOR STANDARD TYPE: HANDS FREE FINISH: WHITE NOTE: PROVIDE MANUFACTURER RECOMMENDED FLUSH VALVE PROVIDE AND INSTALL FLOOR MOUNTED TOILET PARTITIONS: MFG: TBD TYPE: TBD FINISH: BLACK SPECKLE NOTE:CONTRACTOR TO PROVIDE CUT SHEETS FOR DESIGNER AND TENANT APPROVAL PRIOR TO ORDER. NOTE: PROVIDE MANUF. COAT HOOK & BUMPER CENTERED ON DOOR ON TOILET SIDE OF PARTITION. COAT HOOK NOT TO EXCEED 4" MOUNTED DEPTH. PROVIDE AND INSTALL ADA COMPLIANT GRAB BARS: MFG: TBD TYPE: TBD FINISH: STAINLESS STEEL CONTRACTOR TO PROVIDE CUT SHEETS FOR DESIGNER AND TENANT APPROVAL PRIOR TO ORDER. REFER TO TYPICALS AND ELEVATIONS FOR GRAB BAR SIZE AND PLACEMENT AND INSTALL BLOCKING AS REQUIRED. 8 PROVIDE AND INSTALL WALL MOUNTED BABY CHANGING STATION: MFG: KOALA TYPE: KOALA KARE KB200-01 FINISH: GRAY NOTE: PROVIDE BLOCKING IN WALL AND MOUNT AT ADA HEIGHT PER MANUFACTURE RECOMMENDATION (CONTRACTOR TO PROVIDE CUT SHEETS FOR DESIGNER AND TENANT APPROVAL PRIOR TO ORDER) 9 INSTALL TENANT PROVIDED TOILET ROLL DISPENSER IN TOILET ROOMS AS INDICATED. PROVIDE AND INSTALL SANITARY NAPKIN DISPOSAL PER MANUFACTURER'S RECOMMENDATIONS. NOTE: INSTALL IN WOMEN'S RESTROOM ONLY 2 SCALE: 1/4"=1'-0" RESTROOM PLAN1 PT-X 1 12" MOLDING TRIM, PT-X PT-X 3" CROWN TRIM, PT-X DOOR, TRANSOM, AND HARDWARE PER SCHEDULE ON A100 WC-6 4'-6"5'-0"24" MAX 40" MAX. TO BOTTOMOF REFLECTIVE SURFACE34" MAX.27" MIN.6" 9" MIN. 17" MIN ADA LAVATORY CLEARANCE PIPING WITH INSULATION FAUCET AS SCHEDULED INSTALL PHANOMEN PROVIDED MIRROR COUNTERTOP WITH SINK PT-X WALL MOUNTED URINAL. INSTALL PER MANUF. RECOMMENDATION. CONFIRM FINAL HEIGHT WITH OWNER (DO NOT SCALE)4'-6"5'-0"VERIFY WITH ELEVATIONSIMPERVIOUS FINISH36"6" 18" CL CAP TOP OF WALL FINISH TYP ADA COMPLIANT GRAB BARS INSTALL IMPERVIOUS WALL FINISH TOILET PAPER DISPENSER ADA COMPLIANT WATER CLOSET 40" 12"42" 18"40"34"VERIFY WITH ELEVATIONSIMPERVIOUS FINISH17"15" MIN.9"C L CAP TOP OF WALL FINISH TYP ADA COMPLIANT GRAB BARS TOILET PAPER DISPENSER ADA COMPLIANT WATER CLOSET INSTALL IMPERVIOUS WALL FINISH ADA COMPLIANT GRAB BARS INSTALL PHANOMEN PROVIDED MIRROR TYP. (TBD) FAUCET AS SCHEDULE SINK AS SPECIFIED WT-10 TO BE INSTALLED ON FLOOR, WALL, AND CEILING INSTALL PHANOMEN PROVIDED MIRROR TYP. (TBD) FAUCET AS SCHEDULED 8 A102 EQ EQ 5'-0" HOLD2 A201 3 A201 1'-6" EQ EQ C L 1 2 2 3 4 4 3 5 5 6 6 7 7 5'-0" HOLD 18" 18"1'-6"C L5'-6" HOLD5'-6" HOLD3'-0" HOLD 12" MIN 4'-0"EQ EQ N S W E 5 A102 4 A102 1 12" MOLDING TRIM, PT-X PT-X 3" CROWN TRIM, PT-X WC-7 WT-10 TO BE INSTALLED ON FLOOR, WALL, AND CEILING C L C L C L C L C L 1'-1"8 8 8 9 3'-8" 2'-8" 1 1 6'-6"2'-2"6'-0"5'-5"3'-012"8 A102 TOILET PARTITION AS SCHEDULED SCALE: 1/4"=1'-0" INTERIOR ELEVATION5 WOMEN'S RESTROOM INSTALL PHANOMEN PROVIDED MIRROR TYP. (TBD)8"FAUCET AS SCHEDULE ENCLOSE EXISTING PLUMBING AS TIGHTLY AS POSSIBLE. REFER TO WALL TYPES AS REQUIRED. DOORS WITH LOCK TO BE PROVIDED AND INSTALLED BY PHANOMEN/design AT THIS LOCATION. 3FINISH TO TURN CORNERS. CAP OUTSIDE TILE CORNERS WITH MINIMAL SCHLUTER BRUSHED BLACK FINISH TYP.9"MINWT-11, BRICK PATTERN WT-9, STACKED DIAGONAL PATTERN WT-11, BRICK PATTERN WT-9, STACKED DIAGONAL PATTERN 10 PROVIDE AND INSTALL WALL MOUNTED HAND DRYER: MFG: DYSON TYPE: AIRBLADE V AB12 FINISH: NICKEL NOTE: HEIGHT OF OPERABLE BUTTON NOT TO EXCEED 48" A.F.F. NOTE: PROVIDE BLOCKING AND ELECTRICAL AS REQUIRED 11 INSTALL TENANT PROVIDED INTEGRATED SOAP DISPENSER IN LAVATORY COUNTERTOPS. MFG: BOBRICK TYPE: LAVATORY MOUNTED SOAP DISPENSER B-8226 10 10 11 TYP. DOOR, TRANSOM, AND HARDWARE PER SCHEDULE ON A100 EXPOSED CONC. COLUMN (TYP.) 5'-2"5'-134"10'-0" A.F.F.10'-0" A.F.F. 10'-0" A.F.F. 10'-0" A.F.F. 1'-3" 2 2 SCHEDULED LIGHT FIXTURE 6'-0" A.F.F. SCONCE SCHEDULED LIGHT FIXTURE 6'-0" A.F.F. SCONCE SCALE: 1/4"=1'-0" INTERIOR ELEVATION7 MEN'S RESTROOM SCALE: 1/4"=1'-0" INTERIOR ELEVATION6 WOMEN'S RESTROOM WOMEN'S RESTROOM 104 MEN'S RESTROOM 105 6 A102 7 A102 10'-0" A.F.F.10'-0" A.F.F. PT-X WT-11, BRICK PATTERN WT-9, STACKED DIAGONAL PATTERN 1 12" MOLDING TRIM, PT-X 3" CROWN TRIM, PT-X FINISH RR WALL TILE WITH MINIMAL SCHLUTER, FINISH: TBD WT-11, BRICK PATTERN WT-9, STACKED DIAGONAL PATTERN 1 12" MOLDING TRIM, PT-X 3" CROWN TRIM, PT-X INSTALL GRAB BARS TOILET PAPER DISPENSER TOILET PAPER DISPENSER INSTALL GRAB BARS INSTALL GRAB BARS FINISH RR WALL TILE WITH MINIMAL SCHLUTER, FINISH: BRUSHED BLACK FINISH RR WALL TILE WITH MINIMAL SCHLUTER, FINISH: TBD 3 PIPING WITH INSULATION QUARTZ COUNTERTOP TO BE QZ-1. APRON TO HAVE STRAIGHT EDGE 9 6 6 11 WC-6 PT-X SINK AS SPECIFIED 2 WC-7 TYP. 3'-4 18" 1 12" MOLDING TRIM, PT-X PT-X 3" CROWN TRIM, PT-X WC-7 SINK AS SCHEDULED FINISH RR WALL TILE WITH MINIMAL SCHLUTER, FINISH: TBD QUARTZ COUNTERTOP TO BE QZ-1. PROVIDE SQUARE TUBE STEEL SUPPORT. ANCHOR INTO COLUMN AND WALL AS REQUIRED. COORDINATE WITH PHANOMEN/design EQ.EQ. WC-7 WALL TYPE SYMBOLS LEGEND EXISTING WALL CONSTRUCTION TO REMAIN NEW INTERIOR WALL CONSTRUCTION, REFERENCE WALL TYPE FOR FURTHER INFORMATION NEW PARTIAL HEIGHT WALL CONSTRUCTION, REFERENCE WALL TYPE FOR FURTHER INFORMATION WT# WALL TYPE TAG. REFER TO A010 TYPICAL WALL TYPES FOR DETAILS. X WINDOW TAG. REFER TO A201 DOOR AND WINDOW SCHEDULE FOR DETAILS.WT2BWT2B WT11B WT11AWT2BWT2B PLASTIC LAMINATE REMOVABLE PANEL TO BE PL-1 PLASTIC LAMINATE REMOVABLE PANEL TO BE PL-1 PLASTIC LAMINATE REMOVABLE PANEL TO BE PL-1 QUARTZ COUNTERTOP TO BE QZ-1. PROVIDE SQUARE TUBE STEEL SUPPORT. ANCHOR INTO COLUMN AND WALL AS REQUIRED. COORDINATE WITH PHANOMEN/design COUNTETOP TO HAVE 2" RADIUS CORNER 09/23/21 TRASH HOOD RAMP PLAN & DETAILS A103AS NOTEDSCALE: 1/4"=1'-0" ENLARGED PLAN1 SCALE: 1/4"=1'-0" INTERIOR SECTION2 SCALE: 1/4"=1'-0" INTERIOR SECTION3 Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 460322 A103 3 A103 NOTE: RAMP IS FOR KITCHEN DELIVERY ONLY AND NOT AN EXIT ROUTE. OPEN TO BEYOND 3 A103 2 A103 1 8 1 8 5'-212"+/- 3'-10" 2'-2"4'-8"13'-6"+/- 4'-0" 2'-6"+/-VERIFYIN FIELD2'-6"+/-VERIFYIN FIELDALIGN BOTTOM OF RAMP WITH TOP OF FINISHED FLOOR DOOR 109 RAMP SLOPE BEYOND EXISTING WALL EXISTING WALL EXISTING SLAB IN COMMON CORRIDOR ISOLATE DELIVERY RAMP CONSTRUCTION FROM ADJACENT SLAB CONSTRUCTION FINISHED CEILING AS SCHEDULED TURNDOWN EDGE AT SLAB PERIMETER.3'-0" TYP.PROVIDE SEALANT AT CONSTRUCTION JOINT FINISHED CEILING AS SCHEDULED 4" POURED CONCRETE OVER 4" GRANULAR FILL. REINFORCE AS NECESSARY. 4" POURED CONCRETE OVER 4" GRANULAR FILL. REINFORCE AS NECESSARY. TURNDOWN EDGE AT DELIVERY RAMP PERIMETER. TURNDOWN EDGE AT SLAB PERIMETER. HOLD FRAMING AGAINST WALL OF DELIVERY RAMP NOTE: RAMP IS FOR KITCHEN DELIVERY ONLY AND NOT AN EXIT ROUTE. PROVIDE SEALANT AT CONSTRUCITON JOINT TURNDOWN EDGE AT DELIVERY RAMP PERIMETER. 09/23/21 INTERIOR DETAILS & ELEVATIONS A200AS NOTEDCertified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032SCALE: 1/2"=1'-0" INTERIOR ELEVATION2 ENTRY VESTIBULE SCALE: 1/2"=1'-0" INTERIOR ELEVATION3 HOST (PHANOMEN PROVDED) SCALE: 1/2"=1'-0" INTERIOR ELEVATION4 HOST (PHANOMEN PROVIDED) SCALE: 1/2" = 1'-0" INTERIOR ELEVATION5 HOST (PHANOMEN PROVIDED)12"32" 4" 4'-0"CLAD IN BLACK SATIN METAL 1/2" TRIM, PT-X INSET, WC-2 BLACK METAL LEGS 2" TYP. 8'-6"4" TYP.EXPOSED CONCRETE COLUMN. SEAL AND CLEAR COAT 2"2" HOST STATION PROVIDED BY PHANOMEN CLAD IN BLACK SATIN METAL BLACK METAL LEGS HOST STATION PROVIDED BY PHANOMEN WOOD COUNTERTOP, ST-1 A PAINT, PT-X 12'-0"EQ. EQ.4" TYP. 9" 2'-7" WOOD TRIM, ST-2 BTM. OF DECK CLAD EXPOSED END IN BLACK SATIN METAL EXTERIOR WINDOW 12" TYP. 24" CLAD IN BLACK SATIN METAL EXTERIOR WINDOW GENERAL CONTRACTOR TO PROVIDE ELECTRICAL/DATA, BLACK FINISH. COORDINATE REQUIREMENTS WITH TENANT AND PHANOMEN WOOD COUNTERTOP, ST-2 INSTALL 4" BLACK WIRE PULLS TYP FLAT PANEL CABINET DOORS, DRAWER FRONTS AND SHELVING, ST-1 EQ. EQ.EQ.TYPINSET, WC-2 BLACK METAL LEGS SCALE: 1/2"=1'-0" INTERIOR ELEVATION6 BANQUETTE SCALE: 1/2"=1'-0" INTERIOR ELEVATION 7 BANQUETTE BTM. OF DECK GYP. BULKHEAD PHANOMEN PROVIDED BANQUETTE BUILT-IN WOOD BENCH PROVIDED AND INSTALLED BY PHANOMEN GENERAL CONTRACTOR TO PROVIDE AND INSTALL 1X TRIM TO ALIGN WITH OPENING TRIM AS SHOWN WOOD PANELING PROVIDED AND INSTALLED BY PHANOMEN DESIGN WC-X STRIPE LIGHT COVE DETAIL. REFER TO RCP AND CEILING DETAILS TYP PHANOMEN PROVIDED BANQUETTE WOOD BANQUETTE PLATFORM TO BE STAINED ST-X INSTALL WC-8 ON VERTICAL FACE OF BULKHEAD INSTALL WC-8 ON VERTICAL FACES OF BULKHEAD SCALE: 1/2"=1'-0" INTERIOR ELEVATION1 ENTRY VESTIBULE 12'-0" AFF 9'-3" AFF 7'-4" AFF WALL FIXTURE SCONCE NEW WOOD PANELING TO BE ETCHED W/ 1/2" 'V' GROOVE. FINISH W/ 'ST-1'. CONTACT PHANOMEN TO COORDINATE FINAL DESIGN AND DIGITAL FABRICATION FILE. EXPOSED CONCRETE SEAL AND CLEAR COAT GYP BULKHEAD 14'-6" A.F.F.4'-0"PANEL4'-0"PANEL4'-0"PANELWOOD 2'-0" 2'-0"ALIGN WITH DOOR AS SHOWNEXISTING EQ.TYP12" TYP A EQ EQ EQ. EQ. EQ. ADJUSTABLE WOOD SHELVES EXISTING 14'-6" A.F.F. GENERAL CONTRACTOR TO PROVIDE AND INSTALL VINYL APPLICATION ON WOOD BANQUETTE PLINTH AND PLATFORM. SUBMIT SAMPLE TO DESIGNER FOR APPROVAL.ALIGN PATTERN AS SHOWN TYP INSTALL WALLCOVERING WC-X ON WALL STRIPE LED LIGHT COVE TO BE PAINTED PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X INSTALL WC-X OPEN TO BEYOND CASED OPENING SURROUND. REFER TO A100 FOR DETAILS CORNER TRIM PROVIDED AND INSTALLED BY PHANOMEN SCHEDULED BASE TYP GENERAL CONTRACTOR TO PROVIDE AND INSTALL VINYL APPLICATION ON WOOD BANQUETTE PLINTH. SUBMIT SAMPLE TO DESIGNER FOR APPROVAL. ALIGN PATTERN AS SHOWN TYP PAINT GYP SURFACES OF WALL PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X STRIPE LED LIGHT COVE TO BE PAINTED PT-X BTM. OF DECK EXISTING A401 3 TYP GENERAL CONTRACTOR TO COORDINATE THE LOCATION OF STRIPE LED COVES WITH BOOTH MANUFACTURE AND DESIGNER. TYP GENERAL CONTRACTOR TO COORDINATE THE LOCATION OF STRIPE LED COVES WITH BOOTH MANUFACTURE AND DESIGNER. TYP INSTALL WC-8 ON VERTICAL FACE OF BULKHEAD 3 A205 4 A205 DUPLEX OUTLET IN OIL RUBBED BRONZE FINISH . DUPLEX OUTLET TO AVOID COLORED STRIPE LOCATIONS WOOD DOOR, ST-2 PULL HARDWARE BY PHANOMEN 09/23/21 INTERIOR ELEVATIONS A201AS NOTEDSCALE: 1/2"=1'-0" INTERIOR ELEVATION1 BOOTH 2 A205 Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 460321 1/2" TOP BOOTH STRUCTURE WITH WOOD CAP, ST-1 TYP PHANOMEN PROVIDED BOOTHS SIDE OF WALL AND PLATFORM CLAD IN WALL TILE WT-4, WT-5, WT-6, WT-7. PATTERN TO BE PROVIDED BY PHANOMEN 20'-0"7"6'-0"SCALE: 1/2"=1'-0" INTERIOR ELEVATION2 RAILING AT BOOTH (PHANOMEN PROVIDED) RAILING BEYOND BY PHANOMEN 3" WOOD SLATS, ST-2 12" TYP. EQ EQ EQ 3" TYP. PARTIAL HEIGHT WALL BEYOND 7"112"TYP.1" TYP. SATIN BLACK METAL RAILING PROVIDED AND IINSTALLED BY PHANOMEN. SECURE TO FLOOR AND SIDE OF BOOTH PLATFORM STRUCTURE 1" WOOD CAP, ST-2 4'-2"SCALE: 1/2"=1'-0" INTERIOR ELEVATION3 METAL SCREEN AT HOST (PHANOMEN PROVDED) 3" TYP. 3'-101 2" 3'-101 2"8'-9"1" 70°9" 8" 1'-9" 3"9"1'-9" 1'-9"SCALE: 1/2"=1'-0" INTERIOR ELEVATION4 RAILING (PHANOMEN PROVIDED) SCALE: 1/2"=1'-0" INTERIOR ELEVATION5 RAILING (PHANOMEN PROVIDED) SATIN BLACK METAL SCREEN PROVIDED AND INSTALLED PHANOMEN. SATIN BLACKMETAL SCREEN PROVIDED AND INSTALLED BY PHANOMEN WOOD CAP, ST-1 TYP 5'-6"4'-6"3'-5" 1"1" TYP. 3'-5" 1"1" TYP.7"7"EQ. EQ. EQ. EQ. 9" TYP. 9" TYP. 3" WOOD SLATS, ST-2 SCALE: 1/2"=1'-0" INTERIOR ELEVATION8 POS/RESET SCALE: 1/2"=1'-0" INTERIOR ELEVATION6 CURVED BOOTH4'-8"GENERAL CONTRACTOR TO INSTALL 'WT-2' ON OUTSIDE WALL OF PHANOMEN PROVIDED BOOTH STRUCTURE; STRAIGHT STACK PATTERN GENERAL CONTRACTOR TO INSTALL 1X WOOD CAP, ST-1 GENERAL CONTRACTOR TO INSTALL WC-4 ON INSIDE OF PHANOMEN PROVIDED PARTIAL HEIGHT BOOTH STRUCTURE 6'-0"7"WOOD CAP ON PARTIAL HEIGHT WALL TO BE STAINED, ST-X WC-4 PHANOMEN PROVIDED BOOTH FLOORING ON TOP OF PLATFORM TO BE LVT-1 SCALE: 1/2"=1'-0" INTERIOR ELEVATION7 BOOTH WOOD CABINETS, ST-1 WITH BLACK MELAMINE INTERIOR TYP PHANOMEN TO PROVIDE AND INSTALL SATIN BLACK METAL PANEL ON FACE OF FLAT PANEL DOOR. COORDINATE HOLE IN DOOR WITH PHANEOMN. TYP 4" W x 1-1/2" H OPENING IN PANEL TYP 3'-4" 3'-4" 3'-0" PHANOMEN PROVIDED ACCESSORY 2" METAL SHELF APRON 8" ROUND GROMMET OPENING FOR GARBAGE RESET STATION BY GENERAL CONTRACTOR, PROVIDE REQUIRED PLUMBING AND ELECTRICAL FOR KITCHEN AND TENANT PROVIDE EQUIPMENT. BTM. OF DECK 7'-3" AFF DUPLEX OPEN METAL SHELVING PROVIDED AND INSTALLED BY BY PHANOMEN. TYP TRASH CAN BY OWNER QUARTZ COUNTERTOP TO BE QZ-1, WATERFALL EDGE TO EXTEND TO FLOOR, MITER CORNERS TYP 3'-0" 1'-8" 10" 10" 10" 10"9'-1"7 A201 CAP EXPOSED EDGE OF TILE W/ SCHLUTER JOLLY IN TBD FINISH TYP PROVIDE PROPER SCHLUTER OUTSIDE CORNER TRANSITION TO ACCOMMODATE TILE AND PLATFORM FLOOR FINISH SIDE OF WALL AND PLATFORM BEYOND TO BE CLAD IN WT-X TYP PROVIDE PROPER SCHLUTER OUTSIDE CORNER TRANSITION TO ACCOMMODATE TILE AND PLATFORM FLOOR FINISH CAP EXPOSED EDGE OF TILE W/ SCHLUTER JOLLY IN TBD FINISH TYP GENERAL CONTRACTOR TO COORDINATE BLOCKING AND MOUNTING AS REQUIRED. PHANOMEN PROVIDED AND INSTALLED BOOTH PHANOMEN PROVIDED AND INSTALLED BOOTH PARTIAL HEIGHT STRUCTURE CAP EXPOSED EDGE OF TILE W/ SCHLUTER JOLLY IN TBD FINISH TYP PHANOMEN PROVIDED METAL RAILING METAL FRAMED PLATFORM CAP EXPOSED EDGE OF TILE W/ SCHLUTER JOLLY IN TBD FINISH TYP PROVIDE PROPER SCHLUTER OUTSIDE CORNER TRANSITION TO ACCOMMODATE TILE AND PLATFORM FLOOR FINISH SCHEDULED BASE EQ EQ EQ 2 A205 SIM EQ EQ HOLE IN SHELF APRON FOR ACCESSORY MOUNTING EQ EQ 1'-0"10" EQ EQ 2"4"BLACK MELAMINE INTERIOR W/ TWO ADJUSTABLE SHELVES WOOD END CAP TO BE ST-1 TYP. CAP TO BE 1/2" PROUD OF FINISHED WALL 1X WOOD END CAP TO BE ST-1 TYP. END CAP TO BE 1/2" PROUD OF FINISHED WALL 1X WOOD END CAP, ST-1 TYP. WOOD END CAP TO BE 1/2" PROUD OF FINISHED WALL MITER EDGE MITER EDGE TYP. MITER EDGE TYP. METAL INFILL PANEL PAINT WALL PT-4 METAL INFILL PANEL PAINT WALL PT-X 1X2 CHAIR RAIL TO BE ST-X 09/23/21 INTERIOR ELEVATIONS A202AS NOTEDCertified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032SCALE: 1/2"=1'-0" INTERIOR ELEVATION3 POS STATION AT PRIVATE DINING SCALE: 1/2"=1'-0" INTERIOR ELEVATION2 BACK WALL OF PRIVATE DINING SCALE: 1/2"=1'-0" INTERIOR ELEVATION1 KITCHEN ENTRANCE 7" 2'-11"9"3'-5" CAP WITH WOOD CAP, ST-X 3" WOOD SLATS, ST-X SATIN BLACK GUARDRAIL TO WALL AS REQUIRED AND POST PROVIDED AND INSTALLED NY PHANOMEN WC-4 WT-12 BTM. OF DECK BTM. OF DECK 3'-0" OUTLET 3'-0" OUTLET NEON LIT ART PIECE PROVIDED BY PHANOMEN/design. PROVIDE BLOCKING. ADD RECESSED OUTLETS FOR POWER AS NEEDED. 3" WOOD PLANKS, ST-X 3" WOOD PLANKS, ST-X WC-4 WC-4 PT-X 6'-0" EQ EQ EQ EQ WOOD TRIM CASED OPENING. REFER TO DETAIL F1 ON A100 WOOD CABINETS, ST-1 WITH BLACK MELAMINE INTERIOR 2 A205 SIM OPEN TO BEYOND GYP. CEILING ABOVE, PAINTED PT-X CONTRACTOR TO INSTALL ARCHED CEILING, ST-2. REFER TO CEILING DETAILS AND COORDINATE WITH PHANOMEN EXISTING WOOD CEILING 12'-4" A.F.F. SCHEDULED PENDANT PHANOMEN PROVIDED CUSTOM LIGHT FIXTURE TYP 6"1X WOOD TRIM; ST-2 GYP. CEILING ABOVE, PAINTED PT-X 1X WOOD TRIM; ST-2 SCONCE. HEIGHT TBD. CONFIRM WITH PHANOMEN PRIOR TO ROUGH-IN EQ CURVED PORTION OF WALL SCHEDULED BASE TYP WOOD TRIM AND RETURNS ST-2 TYP. MITER CORNERS TYP WOOD TRIM AND RETURNS ST-2. MITER CORNERS TYP EXISTING CONCRETE. STAIN AND CLEAR COAT BEAD BOARD; ST-1 INSTALL IN VERTICAL DIRECTION AS SHOWN 2" BENDABLE TRIM; ST-. FINISH FACE OF TRIM TO BE 1/4" PROUD OF BEADBORD 2" BENDABLE TRIM; ST-. FINISH FACE OF TRIM TO BE 1/4" PROUD OF BEADBORD EXISTING 12'-0" A.F.F. 7'-0' A.F.F. RECESSED OUTLET WOOD WALL FINISH WOOD CABINETS, ST-1 WITH BLACK MELAMINE INTERIOR TYP PHANOMEN TO PROVIDE AND INSTALL SATIN BLACK METAL PANEL ON FACE OF FLAT PANEL DOOR. COORDINATE HOLE IN DOOR WITH PHANOMEN. TYP 4" W x 1-1/2" H OPENING IN PANEL TYP 8" ROUND GROMMET OPENING FOR GARBAGE RESET STATION BY GENERAL CONTRACTOR, PROVIDE REQUIRED PLUMBING AND ELECTRICAL FOR KITCHEN AND TENANT PROVIDE EQUIPMENT. OPEN METAL SHELVING PROVIDED AND INSTALLED BY BY PHANOMEN. TYP TRASH CAN BY OWNER QUARTZ COUNTERTOP TO BE QZ-1, WATERFALL EDGE TO EXTEND TO FLOOR, MITER CORNERS TYP3'-0" 1'-8" 10" 10" 10"8'-0"1'-0"10" EQ EQ 2"4"EQ. OUTLET EQ. OUTLET BLACK MELAMINE INTERIOR W/ TWO ADJUSTABLE SHELVES 2" TYP SCHEDULED BASE COORDINATE W. PHANOMEN FOR PATTERN LAYOUT CAP BOTTOM OF WOOD PANEL WITH FINISH WOOD RETURN ST-X INSTALL DECORATIVE WOOD AROUND SHELVING UNIT EQ CURVED PORTION OF WALL SCALE: 1/2"=1'-0" INTERIOR ELEVATION4 NICHE SCHEDULED BASE WOOD PANEL; ST-2. RUN GRAIN VERTICALLY. MITER CORNERS INSTALL BEAD-BOARD IN VERTICAL DIRECTION ON FACE OF CURVED WALL IN NICHE INTERIOR; ST-1 10"EQ EQ 2'-11" 812" 3'-712" 3" R6"5"DASHED LINE DENOTES NICHE BEHIND ARCHED WOOD FRONT PANEL BTM. OF DECK EXISTING 10'-0"CENTER SCHEDULED LED PUCK-LIGHT IN NICHE CAVITY PAINT ALL EXPOSED GYP SURFACES ;PT-X'. FINISH TO WRAP CORNERS FIXED QUARTZ SHELVES; QZ-1 PHANOMEN PROVIDED ART AND ACCESSORY QUARTZ SHELF TO BE 1" PROUD OF FINISHED FACE OF WOOD QUARTZ SHELF TO BE 1" RECESSED OF FINISHED FACE OF WOOD 09/23/21 INTERIOR ELEVATIONS A203AS NOTEDCertified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032SCALE: 1/2"=1'-0" INTERIOR ELEVATION1 BACK BAR SCALE: 1/2"=1'-0" INTERIOR ELEVATION2 BAR FRONT SCALE: 1/2"=1'-0" INTERIOR ELEVATION3 BAR FRONT BTM. OF DECK BTM. OF DECK 13'-4" AFF BTM. OF DECK INSTALL WC-5 ON WALL SEAL EXPOSED CONCRETE WITH CLEAR COAT STAINED WOOD PANELING TO BE ST-1. RUN GRAIN VERTICALLY, MITER EDGES BLACK METAL MESH SHELVES BY PHANOMEN. CONTRACTOR TO INSTALL LED TAP LIGHTING IN U CHANNELS INSTALL TAPE LIGHT AS SPECIFIED ON INSIDE FACE OF ARCHES FINISH: TBD INSTALL WT-X INSTALL QUARTZ COUNTERTOP QZ-1 VERIFY WITH EQUIPMENT VENDOR VERIFY WITH EQUIPMENT VENDOR 3'-11"2'-6" 7'-2" EQ EQ 3'-012" 4'-112" 7'-3"6'-6"3'-6"VERIFY WITH EQUIP VENDOR4"EQ EQ EQ EQ EQ1"TYP.1" TYP. INSTALL QUARTZ COUNTERTOP QZ-1 METALWORK PROVIDED AND INSTALLED BY PHANOMEN. CONTRACTOR TO PROVIDE BLOCKING AND SUPPORT AS NECESSARY INSTALL QUARTZ COUNTERTOP QZ-1 INSTALL PHANOMEN PROVIDED PURSE HOOKS EVERY 5'1'-0"TYP.1'-0" 112"TYP.5'-2" TYP. 1'-0" TYP.3'-6"MATTE BLACK PAINTED HOLLOW PIPES AND FASTENERS PIPE FOOT RAIL HOLLOW PIPES AND FASTENERS METALWORK PROVIDED AND INSTALLED BY PHANOMEN. CONTRACTOR TO PROVIDE BLOCKING AND SUPPORT AS NECESSARY BAR FRONT DESIGN: TBD 10" WOOD BASE TO BE ST-X INSTALL WOOD TRIM, STAIN ST-2 TAP PROVIDED BY OTHERS CONFIRM MOUNTING HEIGHT W/ TENANT 3"6" WOOD TRIM BASE TO BE 1/2" PROUD, FINISH TBD6" CABINET PULL BY PHANOMEN, SPEC TBD WT-8 WC-3 5'-2" EQ EQ 5'-6" EQ EQ 8" ROUND GROMMET OPENING FOR GARBAGE 13'-4" AFF SCALE: 1/2"=1'-0" INTERIOR ELEVATION4 POS STATION AT BAR 1 A205 WOOD CABINETS, ST-1 WITH BLACK MELAMINE INTERIOR TYP. PHANOMEN TO PROVIDE AND INSTALL SATIN BLACK METAL PANEL ON FACE OF FLAT PANEL DOOR. COORDINATE HOLE IN DOOR WITH PHANOMEN. TYP 4" W x 1-1/2" H OPENING IN PANEL TYP. RESET STATION BY GENERAL CONTRACTOR, PROVIDE REQUIRED PLUMBING AND ELECTRICAL FOR KITCHEN AND TENANT PROVIDE EQUIPMENT. OPEN METAL SHELVING PROVIDED AND INSTALLED BY BY PHANOMEN. TYP TRASH CAN BY OWNER QUARTZ COUNTERTOP TO BE QZ-1, WATERFALL EDGE TO EXTEND TO FLOOR, MITER CORNERS TYP BLACK MELAMINE INTERIOR W/ TWO ADJUSTABLE SHELVES GYP. BULKHEAD 3'-0" 1'-8"10" 10" 10" 10"9'-1"CAP TILE WITH MINIMAL SCHLUTER TYP. FINISH TBD 3'-6"10" 2'-0"1X6 WOOD TRIM WD-1, FINISH FACE TO BE FLUSH WITH DECORATIVE PANEL SEAL EXPOSED CONCRETE WITH CLEAR COAT SEAL EXPOSED CONCRETE WITH CLEAR COAT PROVIDE MINIMAL SCHLUTER, FINISH TBD INSTALL WOOD TRIM, STAIN ST-2 13'-4" AFF GYP. BULKHEAD INSTALL PHANOMEN PROVIDED PURSE HOOKS EVERY 5' BAR FRONT DESIGN: TBD FLUSH PANEL DOOR. MATCH ST-X BLACK VINYL BASE KICK TYP. OPEN SHELVES TO MATCH ST-X1'-5" 1'-5"EQ EQ6'-4" 6'-612"1'-8"STAINED WOOD PANELING TO RETURN TO WALL BTM. OF DECK GYP. BULKHEAD 10" WOOD BASE TO BE ST-X INSTALL WC-5 ON WALL METAL SCREEN BY PHANOMEN OPEN BACK SHELVES. WALLCOVERING WC-3 TO BE INSTALLED BEHIND INSTALL NEW DUPLEX OUTLET WITH BLACK FACE PLATE CENTERED ON WOOD PANEL AS SHOWN 1X6 WOOD TRIM WD-1, FINISH FACE TO BE FLUSH WITH DECORATIVE PANEL4"2 A205 09/23/21 INTERIOR SECTIONS A205AS NOTEDCertified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032SCALE: 3/4"=1'-0" SECTION1 BAR SCALE: 3/4"=1'-0" SECTION2 POS/RESET STATION SIM. 1'-0"6'-1"3'-0" 1'-0" 1'-10" 1'-6" 3" BLACK LAMINATE KICK BLACK MELAMINE INTERIOR QUARTZ COUNTERTOP TO BE QZ-1 WITH EASED EDGE. COUNTERTOP TO WATERFALL TO FLOOR PHANOMEN PROVIDED AND INSTALLED METAL SHELVING AND HUTCH SURROUND, ALUMINUM WOOD CABINETRY, STAINED ST-1 KITCHEN EQUIPMENT BY OTHERS, COORDINATE WITH ELECTRICAL AND PLUMBING REQUIREMENTS SCALE: 3/4"=1'-0" SECTION4 BANQUETTE LED TAPE LIGHT, L-1 PAINTED 2x4 WOOD PIECES 7" 11" 11" 2'-412"SCALE: 3/4"=1'-0" SECTION3 BANQUETTE LED TAPE LIGHT, L-1 PAINTED 2x4 WOOD PIECES 7" 11" 2'-412"PHANOMEN PROVIDED BANQUETTE INSTALL CONCEALED 'L1' LINEAR LED IN ROUTED GROOVE ONE LAYER 3/4" MDF OVER ONE LAYER 3/4" VENEER GRADE PLYWOOD SUBSTRATE 'FRP-X' OVER GREENBOARD PLUMBING LINE CHANNEL THROUGH 6" METAL STUDS BLACK VINYL BASE INSTALL PHANOMEN PROVIDED PURSE HOOKS ON 1X, STAINED TO MATCH 'WD-1' INSTALL CONCEALED 'L1' LINEAR LED IN ROUTED GROOVE WATERFALL EDGE QZ-1 COUNTERTOP W/ HALF BULLNOSE EDGE 42"30"4"10" 9" 16"612"BAR FRONT DESIGN: TBD INSTALL TENANT PROVIDED STAINLESS DRINK RAIL COORDINATE WITH K.E.C. 10" WOOD BASE TO BE ST-X LVT-1 TILE-1 PROVIDE PROPER SCHLUTER OUTSIDE CORNER TRANSITION TO ACCOMMODATE TILE AND PLATFORM FLOOR FINISH PHANOMEN TO PROVIDE AND INSTALL SATIN BLACK METAL PANEL ON FACE OF FLAT PANEL DOOR. COORDINATE HOLE IN DOOR WITH PHANOMEN. TYP1'-0" 1'-0" 10"4"PHANOMEN PROVIDED AND INSTALLED METAL APRON 09/23/21 HOOD SOCIALW1W1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 R1 R1 R1 T1 T1 T1 T1 T1 P1 P1 T1 W2 P3 W2 W3 P1 W2 R3 R3 R3 S1 S1 S1 S1 S1 S1 S1 S1 S1 W4 W4 W5 W6 P1 P1 W3 S3 S3 P1 P1 S2 P1 P1P1 W4 L1 L1 L1 L1 L1 L1 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 P2 P2 R2 W3 L1 L1 L1 EM3 EM1EM1 EM1 EM1 EM1 EM1 EM1 EM1 EM2 EM2 EM2 EM3 EM3 EM3 W7 W7 S T2 R1 R1 R1 R1 R3 R3 R3 R3 R3 S2 S2 EXISTING VERTICAL SHAFT S4 S4 S4 S4 W7 SS FP1 FP1 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 NL NL NL NL H1 H1 H1 H1 H1 H1 H1 H1 R4 R4 R4 R4 R4 R4 W7 R4 R4 R4 R4 R4 R4 R4 R4R4 FAN1 FAN1 EM1 EM2 S1 S1 EXISTING AWNING EXISTING AWNING EXISTING AWNING EXISTING AWNING EXISTING AWNING COOLER COOLER S6 S6 S6 S6 S6 S6 SCALE: 1/8"=1'-0" REFLECTED CEILING PLAN1 Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032KEYED REFLECTED CEILING NOTES# GENERAL REFLECTED CEILING PLAN NOTES ACT-1: New 2x4 Suspended ceiling system, 15/16" white grid and non-porous vinyl, by Contractor NL Night Light Fixture Height indication above finished floorx'-x" A.F.F. EM2: Emergi-Lite #TA-PEN-2RM, Edge-lit emergency exit sign w/ red letters on mirror finish, by Contractor EM1: New Emergency Light: Sure-Lites, Apel Series in black finish. + XX" Mounting height to center above finished floor REFLECTED CEILING LEGEND R1: New LED 6" Recessed downlight fixture: Contech K6SA w/ black trim, dimmable, 19W LED 2700K S D Single Pole Switch Dimmer Switch (Install LED compatible dimmer where applicable) 3 3-Way Switch OS Occupancy Sensor (at ceiling): provided and installed by contractor to meet all requirements of the 2010 Indiana Energy Conservation Code Switching Intent, verify with existing conditions and modify as needed for new configuration shown R2: Same as 'R1', but 3" dia. L1: New Linear LED Tape: Contech Lighting,TLT240V0 70-100 LM/FT - 30, 1.3W/ FT LED 2700K lamping - Contractor to verify quantity to fill entire length of liquor shelf, wall cap or bar top overhang and transformer requirements prior to order. FP1: New 2x4' Recessed LED: Metalux FPanel LED Panel Series 912809, 40W 3500K lamping NOTE: FIXTURES BELOW ARE TO BE PROVIDED AND INSTALLED BY CONTRACTOR. NOTE: FIXTURES BELOW ARE TO BE PROVIDED BY PHANOMEN/design AND INSTALLED BY CONTRACTOR EM3: New Combination exit sign and emergency light: Evenlite Telesis TCXCOM Black finish, red LED letters T1: New line voltage track & head: spec: CTL905 Series Eclipse Curve LED Track CTL9052WF27CD-B with Black finish, 14W, 2700K, dimmmable (confirm mounting height with designer) DECORATIVE LIGHTING SCHEDULE IMAGE SYMBOL DESCRIPTION NOTES P2 P3 NEW CUSTOM CEILING MOUNT FIXTURE WITH 21 DROPS. 2W LED LAMPING PER DRO, 2700K MOUNT AT X'-XX" AFF TO BOTTOM OF FIXTURE NEW CHANDELIER; 6W LED LAMPING, 10 LAMPS, 2700K MOUNT AT X'-XX" AFF TO BOTTOM OF FIXTURE MOUNT AT X'-XX" AFF TO CENTER OF FIXTURE W1 W2 W3 CEILING MOUNTED CEILING MOUNTED S1 S3 N S W E 9'-0" A.F.F. ACT-1 10'-0" A.F.F. PT-X 10'-0" A.F.F.PT-X 1. REFER TO FINISH PLAN FOR MORE INFORMATION ON PAINT COLORS AT GYPSUM BOARD BULKHEADS. ALL GYPSUM BOARD BULKHEADS TO BE PAINTED PT-X, UNLESS NOTED OTHERWISE. 2. PROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS, CONFIRM EXISTING. 3. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHT AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF ANY WORK. 4. CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND STATE AND LOCAL BUILDING CODES. 5. ALL DIMENSIONS ARE FROM CENTERLINE TO CENTERLINE OF FIXTURES. 6. ALL GYP. BOARD WALLS, CEILINGS AND BULKHEADS, SHALL BE A SMOOTH LEVEL 4 FINISH AS OUTLINED IN GYPSUM ASSOCIATION GA-214. 7. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. CONFIRM ALL NEW SWITCH LOCATIONS WITH OWNER PRIOR TO ROUGH-IN. 8. ALL MATERIALS EXPOSED WITHIN THE PLENUM MUST BE NONCOMBUSTIBLE OR SHALL COMPLY WITH LABELING, FLAME AND SMOKE DEVELOPMENT RATINGS AS SPECIFIED IN THE CURRENT EDITION OF THE INDIANA MECHANICAL CODE. 9. MEANS OF EGRESS ILLUMINATION SHALL BE LOCATED IN ACCORDANCE WITH SECTION 1006, IBC (675 IAC 13-2.5). 10. INSTALL PHANOMEN PROVIDED DECORATIVE PENDANTS AT HEIGHTS SPECIFIED IN LIGHTING SCHEDULE. PROVIDE BLOCKING AS REQUIRED. CONTACT PHANOMEN/design FOR JUNCTION BOX LOCATION(S) AND MOUNTING HEIGHTS. 11. ALL AREAS OF OPEN DECK TO REMAIN EXPOSED. PAINT DUCTWORK PT-X. 1 L1 TO BE INSTALLED IN BAR SHELVING FEATURE. WAGNER SIGNS TO INSTALL LIT SIGN PROVIDED BY TENANT, CONTRACTOR TO PROVIDE BLOCKING IN CEILING AS REQUIRED AND INSTALL 120 VOLT, 6-10 AMP LOAD ELECTRICAL BOX. COORDINATE ALL MOUNTING AND ELECTRICAL REQUIREMENTS WITH WAGNER SIGNS, CONTACT: DUSTIN FLICK AT DUSTIN@WAGNER-SIGNS.COM OR (317)788-0202. COORDINATE WITH STRUCTURAL ENGINEER AS REQUIRED. INSTALL "L1" AT BAR FRONT COUNTERTOP. DRYWALL BULKHEAD TO EXTEND TO DECK. PROVIDE CEILING BRACING AND/OR BLOCKING AS REQUIRED FOR MILLWORKER PROVIDED DECORATIVE WOOD CEILING FEATURE. PHANOMEN TO COORDINATE PRICING AND FINISHES WITH KDMI. REFER TO DETAILS ON SHEET A401 FOR ADDITIONAL INFORMATION. INSTALL "L1" IN WALL/CEILING FEATURE AT THIS LOCATION. VERTICAL FACE OF BULKHEAD TO BE FINISHED WITH WALLCOVERING WC-8. CUSTOM METAL CEILING TO BE PROVIDED AND INSTALLED BY PHANOMEN/design. EXACT DESIGN AND MOUNTING HEIGHT: TBD. INSTALL RECESSED LIGHT FIXTURE IN MILLWORK. REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHT AND LOCATION. COORDINATE WITH MILLWORKER AS REQUIRED. CUSTOM METAL ARCH TO BE PROVIDED AND INSTALLED BY PHANOMEN/design AND INSTALLED ON BAR TOP. INSTALL PHANOMEN PROVIDED TECTUM CEILING PANELS DIRECTLY TO THE DECK. CONTRACTOR TO PLACE PANELS RANDOMLY AND VERIFY FINAL LAYOUT WITH DESIGNER. 7'-0" A.F.F. DRYWALL HEADER, PAINT PT-X. WAGNER SIGNS TO INSTALL TENANT PROVIDED SIGNAGE ONTO EXISTING AWNING. CONTRACTOR TO PROVIDE (1) 20 AMP 120 VOLT CIRCUIT. SIGNS CONNECTED TO A TIMER. SIGN TO BE SOURCED FROM WAGNER SIGNS, CONTACT: DUSTIN FLICK AT DUSTIN@WAGNER-SIGNS.COM OR (317)788-0202 FOR ADDITIONAL MOUNTING INFORMATION. INSTALL LIT ART PROVIDED BY PHANOMEN/design AT THIS LOCATION, PROVIDE JUNCTION BOX. COORDINATE ELECTRICAL REQUIREMENTS AND SWITCHING WITH PHANOMEN/design. INSTALL DRYWALL BULKHEAD AT 7'-0" A.F.F. PAINT VERTICAL FACE PT-X. INSTALL ACT-1 CEILING AT 8'-6" A.F.F. AT THE HIGH LANDING. INSTALL SCHLUTER, JOLLY IN TBD FINISH ON OUTSIDE EDGES OF TILE INSTALLED ON CEILING. PROVIDE ALLOWANCE FOR PAINTING ALL EXPOSED CONDUIT AND SPRINKLER LINES IN ALL AREAS OF EXPOSED CEILING. COORDINATE WITH DESIGNER FOR FINAL INTENT. EXPOSED DUCTWORK TO REMAIN UNFINISHED GALVANIZED STEEL. SUSPEND TV FROM CEILING IN FRONT OF EXPOSED CONCRETE COLUMN. PROVIDE ALL SUPPORTS AS REQUIRED, CONFIRM MOUNTING HEIGHT WITH TENANT. SCONCE TO BE MOUNTED TO FRONT FACE OF MILLWORK. REFER TO INTERIOR DETAILS FOR MOUNTING HEIGHT AND LOCATION. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED LIGHT FIXTURE LOCATIONS AND MOUNTING HEIGHTS. NEW PERGOLA; DRAWINGS TO BE PROVIDED BY OTHERS. 10'-0" A.F.F. DRYWALL HEADER TO EXTEND TO DECK, PAINT PT-X. CUSTOM PAINTED CEILING DESIGN WITH NEON LIGHTS BY PHANOMEN/design. COORDINATE POWER WITH PHANOMEN/design. INSTALL 36X36 ACCESS PANEL. CONTRACTOR TO COORDINATE LOCATION WITH PHANOMEN/design. COORDINATE COOLER LIGHTING AND CEILING WITH TENANT. PAINT VERTICAL FACE OF BULKHEAD PT-X. INSTALLED SCHEDULED LIGHT FIXTURE IN BULKHEAD, CENTERED OVER DOOR. 2 3 4 5 6 7 0 5 10 20 40 9'-0" A.F.F. PT-X 10'-0" A.F.F. ACT-1 10'-0" A.F.F. WT-X 10'-0" A.F.F. WT-X 14'-6" A.F.F. PT-X 14'-0" A.F.F. PT-X 13'-4" A.F.F. PT-X 12'-4" A.F.F.WD-X 12'-0" A.F.F. WD-X 10'-0" A.F.F. PT-X 13'-4" A.F.F. PT-X 13'-4" A.F.F.PT-X 10'-0" A.F.F. PT-X 8 R3: New LED 6" Recessed downlight fixture: Contech K6SA w/ white trim, dimmable, 19W LED 2700K P1: New 6" Pendant: Contech CYL6, dimmable, in matte black finish, 10W LED 2700K lamping. Coordinate mounting height with PHANOMEN/design. CEILING MOUNTED AND WALL MOUNTED. REFER TO INTERIOR ELEVATIONS FOR DETAILSS2 12'-6" A.F.F. WD-X W4 REFER TO ELEVATIONS FOR MOUNTING HEIGHT W5 W6 1 12 12 3 2 4 5 4 6 7 8 9 9 9 9 1 A401 10 10 11 11 W7: New Exterior Egress fixture: Match Adjacent Tenant 11 12 13 13 14 14 15 15 15 VEST. 101 ENTRY 102 DINING 103 WOMEN'S RESTROOM 104 MEN'S RESTROOM 105 BAR 106 DINING 107 PRIVATE DINING 108 KITCHEN 109 OFFICE 111 TRASH 110 9'-0" A.F.F. PT-X NEWSTRING LIGHT 60W, WET RATED, 2700K A401 6 EXT DECK EXT DECK EXT DECK EXT DECK 16 16 16 16 16 17 17 18 18 18 REFLECTED CEILING PLAN A400 19 19 20 20 R4: New LED Pergola lights by pergola manufacturer. 4.2" recessed, dimmable, 6W, 2700K warm white lamping, 15 degree spot, dark bronze trim NEW EXTERIOR CEILING FAN: SPECIFICATION: TBD. NO LIGHT HT: New Contractor provided heaters. Refer to MEP plans for specification MOUNT AT X'-XX" AFF TO BOTTOM OF FIXTURE MOUNT TO BOTTOM OF AWNING 21 21 22 T2: New line voltage track & head: spec: CTL8070 Series Eclipse Curve LED Track CTL8070M27D_, 9W, 2700K, finish: TBD, dimmable (confirm mounting height with designer) 22 S5: SURFACE MOUNT CUSTOM LIGHT FIXTURE. PROVIDED BY PHANOMEN. 2W LED, 5 LAMPS PER FIXTURE, 2700K S5 S4 FAN 1 NEW SURFACE MOUNT; 4W LED LAMPING, 2700K NEW SURFACE MOUNT; 6W LED LAMPING, 2700K NEW ADJUSTABLE SURFACE MOUNT; 4W LED LAMPING, 2700K NEW SCONCE; 4W LED LAMPING, 2700K NEW SCONCE; 4W LED LAMPING, 2700K NEW SCONCE; 6W LED LAMPING, 2700K NEW SCONCE; 6W LED LAMPING, 2700K NEW SCONCE; 4W LED LAMPING, 2700K NEW SCONCE; 4W LED LAMPING, 2700K 5 MOUNT AT X'-XX" AFF TO CENTER OF FIXTURE, SURFACE MOUNT TO EXPOSED CONCRETE COLUMN, PAINT CONDUIT, PT-X MOUNT AT X'-XX" AFF TO CENTER OF FIXTURE MOUNT AT X'-XX" AFF TO CENTER OF FIXTURE REFER TO ELEVATIONS FOR MOUNTING HEIGHT 9'-0" A.F.F. PT-X 9'-0" A.F.F. PT-X S6: New Fluorescent Surface Mount Cooler/ Freezer Light: CCL-8804OC120, 48" L 23 23 23 23 24 24 24 25 25 4 26 26 09/23/21 SOCIALW1W1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 R1 R1 R1 T1 T1 T1 T1 T1 P1 P1 T1 W2 P3 W2 W3 P1 W2 R3 R3 R3 S1 S1 S1 S1 S1 S1 S1 S1 S1 W4 W4 W5 W6 P1 P1 W3 S3 S3 P1 P1 S2 P1 P1P1 W4 L1 L1 L1 L1 L1 L1 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 P2 P2 R2 W3 L1 L1 L1 EM3 EM1EM1 EM1 EM1 EM1 EM1 EM1 EM1 EM2 EM2 EM2 EM3 EM3 EM3 W7 W7 S T2 R1 R1 R1 R1 R3 R3 R3 R3 R3 S2 S2 EXISTING VERTICAL SHAFT S4 S4 S4 S4 W7 SS FP1 FP1 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 NL NL NL NL H1 H1 H1 H1 H1 H1 H1 H1 R4 R4 R4 R4 R4 R4 W7 R4 R4 R4 R4 R4 R4 R4 R4R4 FAN1 FAN1 EM1 EM2 S1 S1 EXISTING AWNING EXISTING AWNING EXISTING AWNING EXISTING AWNING EXISTING AWNING COOLER COOLER S6 S6 S6 S6 S6 S6 HOOD 48" 48" 96" 96" 96" 96" 72" 72" 72" Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032PAINTED FINISH WOOD FACES. COORDINATE COLORS WITH PHANOMEN PAINTED 2X4 WOOD PIECES CONTINOUS LED TAPE LIGHT, L-1 CONTINUOUS LED TAPE LIGHT, L-1 PROVIDE BLOCKING FOR DECORATIVE CEILING FEATURE. GYP PAINTED PT-X 14'-6" A.F.F. GYP. BULKHEAD PT-X; 1X WOOD FACE. PAINT EXPOSED FACES AS SHOWN. COORDINATE WITH PHANOMEN. TYP CONTINUOUS LED TAPE LIGHT, L-1 INSTALL ON SURFACE AS SHOWN AS CLOSE TO CORNER AS POSSIBLE. TYP 12'-4" A.F.F. 13'-4" A.F.F. FAUX 12X4 WOOD BEAM, ST-2 TYP GYP. CEILING ABOVE, PAINTED PT-X CONTRACTOR TO PROVIDE BLOCKING AND BRACING AS REQUIRED FAUX ARCHED WOOD BEAM BEYOND, ST-2 TYP EXISTING DECK SCALE: 3/4"=1'-0" CEILING DETAIL2 SCALE: 3/4"=1'-0" CEILING DETAIL3 SCALE: 3/4"=1'-0" CEILING DETAIL5 EXISTING DECK SCALE: 3/4"=1'-0" ENLARGED PLAN4 5 A401 3 A401 SCALE: 1/2"=1'-0" ENLARGED RCP6 LIGHT FIXTURE AS SPECIFIED DIMENSIONED RELFECTED CEILING PLAN & DETAILS A401 EQ 30° 14'-6" A.F.F. METAL STUD BULKHEAD FRAMING INSTALL WALLCOVERING WC-8 ON FACE OF DRYWALL BULKHEAD SCALE: 1/8"=1'-0" DMIMENSIONED REFLECTED CEILING PLAN1 N S W E 9'-0" A.F.F. ACT-1 10'-0" A.F.F. PT-X 10'-0" A.F.F.PT-X 0 5 10 20 40 9'-0" A.F.F. PT-X 10'-0" A.F.F. ACT-1 10'-0" A.F.F. WT-X 10'-0" A.F.F. WT-X 14'-6" A.F.F. PT-X 14'-0" A.F.F. PT-X 13'-4" A.F.F. PT-X 12'-4" A.F.F.WD-X 12'-0" A.F.F. ST-X 10'-0" A.F.F. PT-X 13'-4" A.F.F. PT-X 13'-4" A.F.F.PT-X 10'-0" A.F.F. PT-X 12'-6" A.F.F. ST-X 1 A401 VEST. 101 ENTRY 102 DINING 103 WOMEN'S RESTROOM 104 MEN'S RESTROOM 105 BAR 106 DINING 107 PRIVATE DINING 108KITCHEN 109 OFFICE 111 TRASH 110 9'-0" A.F.F. PT-X A401 6 EXT DECK EXT DECK EXT DECK EXT DECK 6'-0" TYP. 6'-1012"2'-0" TYP.EQ. EQ. EQ. EQ.EQ. TYP.2'-0" EQ. 6'-0" TYP EQ. 3'-6"1'-3"6'-412" TYP3'-9" 4'-3" 5'-212"3'-6"4'-412" 2'-8" 3'-5"3'-1012"EQTYP3'-3"2'-0"2'-9"2'-9"2'-0" 1'-6" 1'-6"2'-0"8'-2"INSTALL PHANOMEN PROVIDED TECTUM CEILING PANELS DIRECTLY TO DRYWALL CEILING TYP NEW WOOD PANELING TO BE ETCHED W/ 1/2" 'V' GROOVE. FINISH W/ 'ST-1'. CONTACT PHANOMEN TO COORDINATE FINAL DESIGN AND DIGITAL FABRICATION FILE. EQ EQ EQ EQ EQ EQEQEQ2"TYP6"4" 4"4"4"1'-0"WALL METAL STUD CEILING FRAMING PHANOMEN PROVIDED CUSTOM FIXTURE. CONCEAL WIRING IN BEAM AND ABOVE CEILING. TYP 6"TYP8" TYP BLOCKING AS REQUIRED TYP 212" TYPGYP PT-X A401 4 STRIPE STRIPE STRIPE STRIPE STRIPE STRIPENO LED NO LED NO LED WALL 6"7 A401 SCALE: 3/4"=1'-0" SECTION DETAIL7 TYPICAL (STRIPE FEATURE) 8"212"1X WOOD FACE. PAINT EXPOSED FACES AS SHOWN. COORDINATE WITH PHANOMEN. TYP BLOCKING AS REQUIRED TYP CONTINUOUS LED TAPE LIGHT, L-1 INSTALL ON SURFACE AS SHOWN AS CLOSE TO CORNER AS POSSIBLE. TYP FINISH FACE OF WALL 09/23/21 POS/ RESETPOS HOST POS/ RESET RESET HOOD FINISH FLOOR PLAN A7011/4" = 1'- 0"Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032SCALE: 1/8"=1'-0" FLOOR PLAN1 0 5 10 20 40 N S W E INSTALL 'WB-1' AT ALL AREAS, UNLESS OTHERWISE NOTED. COORDINATE AREAS OF WALL BASE WITH BANQUETTE AND BOOTH LOCATIONS. PROCEEDING WITH INSTALLATION OF FINISHES WILL BE CONSTRUED THAT THE INSTALLER AND/OR FINISHER HAS INSPECTED AND ACCEPTED THE SUBSTRATE FOR RECEIVING THE WORK. NO CHANGE ORDER WILL BE ISSUED TO RECTIFY CEONCEALED, UNKNOWN CONDITIONS OR UNSATISFACTORY SUBSTRATE ONCE THE FINISH WORK HAS PROCEEDED. USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES. FLOORING CONTRACTOR TO INSTALL A CEMENTITIOUS UNDERLAYMENT SKIM COAT TO LEVEL EXISTING SUBSTRATE AS NEEDED TO ACCEPT NEW FLOORING MATERIAL AND TO SMOOTH/MINIMIZE HEIGHT TRANSITIONS BETWEEN FLOORING OF VARYING HEIGHTS. PROVIDE SEAMING DIAGRAM FOR CARPET AND TILE LAYOUT FOR DESIGNER APPROVAL PRIOR TO INSTALLATION. PAINT ALL GRILLES, DIFFUSERS, ETC., TO MATCH SURFACE ON WHICH THEY OCCUR. CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER IF A SPECIFIED FINISH ITEM BECOMES UNAVAILABLE. CONTRACTOR TO SUBMIT CUTS/SAMPLES OF ALL FINISHES TO DESIGNER FOR APPROVAL PRIOR TO ORDERING. F. E. C. D. B. A. GENERAL FINISH NOTES USE MINIMAL BRUSHED BLACK ANODIZED ALUMINUM METAL TRANSITIONS (SCHLUTER OR EQUAL, HEIGHT AS REQUIRED). AT THRESHOLDS, CENTER TRANSITION STRIP UNDER CENTERLINE OF DOOR OR CENTERLINE OF OPENING, WHICHEVER APPLIES. H. TENANT'S EQUIPMENT VENDOR TO INSTALL STAINLESS STEEL CORNER PROTECTORS FLOOR TO CEILING AT ALL OUTSIDE CORNER AT KITCHEN. I. J. AT ALL KITCHEN AREAS: 1. INSTALL SPECIFIED VINYL BASE. 2. PAINT SPECIFIED EPOXY PAINT ON ALL WALLS, UNLESS NOTED OTHERWISE. G. ALL WOODWORK/MILLWORK SHALL CONFORM TO THE QUALITY STANDARDS OF ARCHITECTURAL WOODWORK INSTITUTE (AWI) PREMIUM GRADE FOR ALL APPLICABLE SECTIONS. FABRICATOR SHALL BE FAMILIAR WITH AWI STANDARDS. FABRICATE WOODWORK/MILLWORK ITEMS TO ACTUAL FIELD DIMENSIONS. CONTRACTOR(S) SHALL SUBMIT SHOP DRAWINGS, SAMPLES, OR MANUFACTURER'S LITERATURE FOR ALL ITEMS. SHOP DRAWINGS SHALL SHOW SUFFICIENT DETAIL TO DETERMINE COMPLIANCE WITH QUALITY STANDARDS AND DESIGN INTENT. PROVIDE ALL NECESSARY FURRING AND GROUNDS FOR WOODWORK AND FINISH ITEMS. COORDINATE LOCATION OF BLOCKING WITHIN PARTITIONS FOR ITEMS TO BE SECURED TO SURFACE. ALL FASTENERS SHALL BE CONCEALED. C. B. A. GENERAL MILLWORK NOTES FINISH PLAN NOTES # 1 2 3 SEALED CONCRETE FLOORING. PROVIDE SLIP RESISTANT COAT AS REQUIRED, COORDINATE WITH TENANT. WALL TILE WT-10 TO BE INSTALLED ON FLOOR, WALL, AND CEILING. REFER TO A102 FOR FINISH APPLICATION OF RESTROOM TILE. K.E.C. TO INSTALL INSTALL STAINLESS STEEL PANELING; CONFIRM FINAL LOCATIONS WITH KITCHEN VENDOR. INSTALL WATERPROOFING MEMBRANE 12" UP WALL @ FLOOR AROUND PERIMETER OF ROOM AS REQUIRED. INSTALL TILE WT-1 AND WOOD PANELING IN PATTERN AS SPECIFIED IN ELEVATIONS. WOOD PANELING TO BE COMBINATION OF ST-1 AND ST-2. INSTALL WALL TILE WT-3 TO 40" A.F.F. WITH SINGLE BAND OF WALL TILE WT-2 TO BE INSTALLED ABOVE. REFER TO ELEVATIONS FOR DETAILS. PAINT WALL ABOVE TO BE PT-X. INSTALL WALL TILE WT-8 TO 42" A.F.F. AND WALLCOVERING WC-4 FROM 42" A.F.F. TO CEILING ABOVE. INSTALL TILE-1 ON FLOOR. PHANOMEN TO PROVIDE PATTERN. ACOUSTICAL WOOD PLANK FEATURE WALL; SEE INTERIOR ELEVATIONS FOR MORE INFORMATION. ACOUSTICAL SPEC; TBD. INSTALL WALL TILE WT-12 FROM FLOOR TO 42" A.F.F. AND PAINT PT-X ABOVE. SEE INTERIOR ELEVATIONS FOR BACK BAR DESIGN. PAINTED STRIPE WALL FEATURE; REFER TO ELEVATIONS FOR MORE INFORMATION. CONTRACTOR TO INSTALL VINYL DECAL TO MATCH UPHOLSTERY STRIPES ON BANQUETTE PLINTH, PLATFORM, AND ONTO FLOOR IN CONTINUOUS STRIPE. CONTRACTOR TO PROVIDE SPEC, COORDINATE WITH PHANOMEN. AT ALL WALLS, WALL TILE PATTERN TO EXTEND 5'-0" A.F.F. WITH WALLCOVERING WC-7 AND PAINT PT-X ABOVE. CAP TILE WITH SCHLUTER STRIP. SEE ELEVATIONS ON A102 FOR MORE INFORMATION. REFER TO DETAIL 2/A701 FOR CROWN MOLDING. NEW GRANITE WINDOW SILL TO BE GR-1. INSTALL WC- 5 ON DRYWALL BETWEEN ARCHES. REFER TO ELEVATIONS FOR LOCATION AND DETAILS. BEGIN PLACEMENT OF TILE IN THIS LOCATION. PLACEMENT IS CRUCIAL TO MATCHING WITH UPHOLSTERY PLACEMENT. COORDINATE WITH DESIGNER. INSTALL TILE WT-4,5,6,&7 PATTERN ON VERTICAL FACES OF PLATFORM. REFER TO ELEVATIONS FOR INSTALL PATTERN. INSTALL WC-4 AT THIS LOCATION TO 7'-10 A.F.F. REFER TO ELEVATIONS FOR MORE INFORMATION. ACOUSTICAL WOOD PLANKS TO BE INSTALLED ABOVE AS SHOWN IN ELEVATION. NOT USED. WALL TILE WT-2 TO BE INSTALLED ON PARTIAL HEIGHT WALL FROM FLOOR TO TOP OF WALL. PROVIDE WOOD CAP ON TOP OF WALL. REFER TO ELEVATION 6/A201 FOR DETAILS. INSTALL TILE-2 ON FLOOR. PHANOMEN TO COORDINATE DESIGN. WALLCOVERING WC-4 TO BE INSTALLED ON WALL ABOVE PHANOMEN PROVIDED BOOTH. REFER TO ELEVATION 6/A201 FOR DETAILS. ALL WALLS TO BE PAINTED WITH EPOXY PAINT PT-2 UNLESS NOTED OTHERWISE. INSTALL COVE VINYL BASE VB-1 THROUGHOUT. PHANOMEN PROVIDED WOOD SLAT WALL WITH DECORATIVE LIGHT FEATURE. INSTALL WALLCOVERING ABOVE TO BE WC-X. PAINT WALLS PT-X AND INSTALL WOOD BASE WB-1 UNLESS NOTED OTHERWISE. PAINT WALLS PT-X AND INSTALL VINYL BASE VB-1. INSTALL TILE-3 ON FLOOR THROUGHOUT, UNLESS NOTED OTHERWISE. INSTALL TILE-2 ON PARTIAL HEIGHT WALL. CAP OUTSIDE TILE CORNERS WITH MINIMAL SCHLUTER BRUSHED BLACK FINISH. EXISTING CONCRETE TO REMAIN, PROVIDE SEALED CLEAR COAT. ON ALL WALLS, WALL TILE PATTERN TO EXTEND 5'-0" A.F.F. WITH WALLCOVERING WC-6 AND PAINT PT-X ABOVE. SEE ELEVATIONS ON A102 FOR MORE INFORMATION. REFER TO DETAIL 2/A701 FOR CROWN MOLDING. WT-8 TO EXTEND TO 42" A.F.F. AND INSTALL WALLCOVERING WC-3 AT 42" A.F.F. TO CEILING ABOVE. NEW 1X2 CHAIR RAIL TO BE INSTALLED AT 34" A.F.F. TO THE BOTTOM OF THE RAIL, WHERE APPLICABLE. FINISH TO BE ST-X. CHAIR RAIL TO WRAP CORNER AT WINDOW OPENINGS AND TERMINATE AT WINDOW. PAINT WALL BELOW CHAIR RAIL TO BE PT-4. PAINT WALL ABOVE CHAIR RAIL TO BE PT-X. INSTALL WALLCOVERING WC-1 ON WALL. PROVIDE WB-1 BASE. INSTALL ETCHED DECORATIVE WOOD PANELING ON WALL. REFER TO ELEVATIONS FOR DETAILS. INSTALL VERTICAL WOOD PANELING ALONG CURVED WALL. INSTALL 1X WOOD ON END OF PARTIAL HEIGHT WALL . WOOD TO BE ST-1. 4 5 6 7 8 9 10 11 12 13 14 15 16 FINISH SPECIFICATIONS BASE & TRIM COLOR: NUMBER: STYLE: MANUFACTURER: WB-1 BY CONTRACTOR 1X6" WOOD BASE W/ SHOE & CAP STAIN GRADE ST-1 (COORDINATE BASE LOCATIONS WITH ALL BANQUETTES, BOOTHS, AND FURNITURE, CONTACT DESIGNER FOR DETAILS.) INSTALL THROUGHOUT UNLESS OTHERWISE NOTED. FLOORS COLOR: NUMBER: STYLE: MANUFACTURER:TILE-1 LOUISVILLE TILE RELIVE N/A MONTANA MILLWORK COLOR: NUMBER: STYLE: MANUFACTURER:QZ-1 TBD TBD TBD TBD WALLS CEILINGS COLOR: NUMBER: STYLE: MANUFACTURER: ACT-1 BY CONTRACTOR 15/16" GRID AND NON-POROUS VINYL TBD WHITE COLOR: NUMBER: STYLE: MANUFACTURER:WT-2 LOUISVILLE TILE LILI GLAZED TILE LINE G-GT GARNET COLOR: NUMBER: STYLE: MANUFACTURER:WT-3 LOUISVILLE TILE LILI GLAZED TILE LINE G-NAM NEW AQUAMARINE COLOR: NUMBER: STYLE: MANUFACTURER:WC-1 PHILLIP JEFFRIES VINYL ZEBRAWOOD 7872 FARMHOUSE BROWN COLOR: NUMBER: STYLE: MANUFACTURER:WT-5 LA PIETRA COMPATTATA CROMIE N/A ARANCIO 1 4 4 9 COLOR: NUMBER: STYLE: MANUFACTURER:WT-4 LA PIETRA COMPATTATA CROMIE N/A GIALLO WALLS 2 12 12 30 13 (PROVIDED AND INSTALLED BY GENERAL CONTRACTOR) (FINISHES BELOW TO BE PROVIDED BY PHANOMEN AND INSTALLED BY GENERAL CONTRACTOR) 17 11 COLOR: NUMBER: STYLE: MANUFACTURER:G-1 ARCHITECTURAL GLASS REED ESTRIADO TEMPERED GL 600 N/A COLOR: NUMBER: STYLE: MANUFACTURER:G-2 ARCHITECTURAL GLASS MASTER-CARRE CLEAR TEMPERED GL MC0110 N/A COLOR: NUMBER: STYLE: MANUFACTURER:TILE-2 ARCHITECTURAL BRICK & TILE APAVISE ENCAUSTIC ABT-P213ENCODE12L COAL DECOR LAPPATO COLOR: NUMBER: STYLE: MANUFACTURER:WC-5 ASTEK INC PLUME N/A KINGFISHER COLOR: NUMBER: STYLE: MANUFACTURER:WC-2 ELITIS COCO SHELLS RM 942 02 CAMARINES COLOR: NUMBER: STYLE: MANUFACTURER:WC-4 ELITIS ANGUILLE BIG CROCO GALUCHAT VP 424 07 ANGUILLE COLOR: NUMBER: STYLE: MANUFACTURER:WC-3 HD WALLS CALAVERA HDW-CALAVERA-03 VOODOO 18 18 VEST. 101 ENTRY 102 DINING 103 WOMEN'S RESTROOM 104 MEN'S RESTROOM 105 BAR 106 DINING 107 PRIVATE DINING 108 KITCHEN 109 OFFICE 111 TRASH 110 COLOR: NUMBER: STYLE: MANUFACTURER:ST-2 SHERWIN WILLIAMS WOOD CLASSICA INTERIOR OIL STAIN SW 3124-P PECAN COLOR: NUMBER: STYLE: MANUFACTURER:ST-3 BY CONTRACTOR BLACK STAIN -- -- COLOR: NUMBER: STYLE: MANUFACTURER:ST-1 SHERWIN WILLIAMS WOOD CLASSICA INTERIOR OIL STAIN SW 3132-K BEECHWOOD PROVIDE SAMPLE ON WOOD BEING USED FOR APPROVAL 3 COLOR: NUMBER: STYLE: MANUFACTURER:WT-1 TILEBAR ARDEN N/A FOREST RIDGE COLOR: NUMBER: STYLE: MANUFACTURER:WT-6 LA PIETRA COMPATTATA CROMIE N/A ROSSO COLOR: NUMBER: STYLE: MANUFACTURER:WT-7 LA PIETRA COMPATTATA CROMIE N/A VERDE CHIARO COLOR: NUMBER: STYLE: MANUFACTURER:WT-9 DALTILE COLORWHEEL K111 BLACK COLOR: NUMBER: STYLE: MANUFACTURER:WT-10 DALTILE NATURAL HUES QH30 KIWI COLOR: NUMBER: STYLE: MANUFACTURER:WT-11 DALTILE COLORWHEEL 0109 ARCHITECTURAL GREY COLOR: NUMBER: STYLE: MANUFACTURER:WT-8 TRINITY TILE KEA N/A BLACK COLOR: NUMBER: STYLE: MANUFACTURER:TILE-3 CROSSVILLE ALTERED STATE N/A STEEL GAZE PROVIDE SAMPLE OF WOOD SPECIES AND STAIN FOR DESIGNER APPROVAL 19 20 COLOR: NUMBER: STYLE: MANUFACTURER:WC-6 THE DETROIT WALLPAPER DIA DE LOS MUERTOS -- CALACA COLOR: NUMBER: STYLE: MANUFACTURER: WC-7 THE DETROIT WALLPAPER DIA DE LOS MUERTOS -- ALTAR COLOR: NUMBER: STYLE: MANUFACTURER:G-3 CAMDEN STAINED GLASS (BY CONTRACTOR) CUSTOM STAINED GLASS - - CONTRACTOR PROVIDED CONTACT: KEVIN PHILLIPS (317) 426-5427 KEVIN@CAMDENSTAINEDGLASS.COM PROVIDE SAMPLE TO PHANOMEN PRIOR TO ORDERING 20 20 28 28 21 21 21 21 PROVIDE SAMPLE OF WOOD SPECIES AND STAIN FOR DESIGNER APPROVAL GLAZING PAINT COLOR: NUMBER: STYLE: MANUFACTURER: PT-1 SHERWIN WILLIAMS LATEX TBD TBD COLOR: NUMBER: STYLE: MANUFACTURER:PT-2 TBD EPOXY TBD TBD CEILING (SPRINKLERS AND CONDUIT) KITCHEN WALLS (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT LOUISVILLE TILE AT 317.366.2835 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT LOUISVILLE TILE AT 317.366.2835 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT LOUISVILLE TILE AT 317.366.2835 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT LOUISVILLE TILE AT 317.366.2835 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT STONE SOURCE AT 314.2824858 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT STONE SOURCE AT 314.2824858 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT STONE SOURCE AT 314.2824858 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT STONE SOURCE AT 314.2824858 (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) CONTACT SOURCE ONE CONTRACT AT BRIGETTE@SOURCEONECONTRACT.COM 22 COLOR: NUMBER: STYLE: MANUFACTURER:WT-12 DALTILE COLORWHEEL 0190 WHITE (INSTALL W/ #TBD LATICRETE GROUT OR APPROVED EQUAL) SIZE: 3X6 SIZE: 4X4 SIZE: 3X6 SIZE: 4X4 14 14 14 14 14 14 14 2 1 1 1 1 4 1 CONC-1 MANUFACTURER: BY CONTRACTOR STYLE: SEALED CONCRETE FINISH: SLIP RESISTANT COORDINATE ALL REQUIREMENTS WITH TENANT CONC-1 TILE-1 TILE-2 TILE-1 TILE-2 TILE-1 TILE-2 TILE-1 TILE-1 TILE-3 TILE-3 TILE-1 TILE-3 WT-10 TILE-3 WT-10 5 SCALE:NO SCALE CROWN MOULDING A701 2 COLOR: NUMBER: STYLE: MANUFACTURER:LVT-1 TBD TBD TBD TBD TILE-1 LVT-1 17 17 COLOR: NUMBER: STYLE: MANUFACTURER:ACP-1 ARMSTRONG TECTUM PANELING TBD TBD 6 7 8 8 8 TILE-1 CONC-1 10 10 15 22 22 22 22 COLOR: NUMBER: STYLE: MANUFACTURER:PT-3 SHERWIN WILLIAMS LATEX TBD TBD WALLS 23 23 23 23 24 24 25 25 25 25 COLOR: NUMBER: STYLE: MANUFACTURER:VB-1 BY CONTRACTOR VINYL BASE TBD TBD 26 26 16 27 27 27 TILE-2 CONCRETE CONCRETE TILE-1 CONCRETETILE-1 TILE-1 CONCRETE 28 15 29 29 29 29 30 COLOR: NUMBER: STYLE: MANUFACTURER:GR-1 CONTRACTOR PROVIDED TBD TBD BLACK SUEDE PROVIDE SAMPLE OF WOOD SPECIES AND STAIN FOR DESIGNER APPROVAL 31 31 1 23 32 COLOR: NUMBER: STYLE: MANUFACTURER:PT-4 WOLF GORDON SCUFF MASTER TBD TBD WALLS 32 COLOR: NUMBER: STYLE: MANUFACTURER:PL-1 TBD TBD TBD TBD 32 32 32 25 33 33 34 34 35 35 35 COLOR: NUMBER: STYLE: MANUFACTURER:WC-8 TBD TBD -- TBD INSTALLED ON VERTICAL FACE OF BULKHEAD36 3636 36 36 36 36 LVT-1 PAINTS SPECIFIED UNDER FINISH SPECIFICATIONS TO INDICATE COLOR ONLY. CONTRACTOR TO PROVIDE APPROPRIATE LATEX PAINT SPECIFICATION FOR INTENDED SUBSTRATE(S) UNLESS OTHERWISE NOTED AND MATCH DESIGNER SPECIFIED SHEEN AND COLOR. WALLS: SATIN LATEX CEILINGS: FLAT LATEX TRIM AND MOLDING: SATIN LATEX ENAMEL C. A. B. GENERAL PAINT NOTES 09/23/21 3 YDDUMPSTER3 YD DUMPSTER CO2OIL TANK36"X72"32X32 32X32 32X32 32X48 32X32 32X32 48X36 48X36 48X3636x36 TV TV 48X36 36x36 24X3648X3636x36 POS/ RESET24X36 36x36 48X36 24X36 24X36 32X4832X48POS 32X108 36Ø HT 32X48 HOST 32X24 32X24 32X2432X4830x84 32X32 36Ø HT 32x120 24x30 HT 24x30 HT 24x30 HTTV TV30x48 30x48 30x48SUPPLY MAKE-UP 30x48 24x30 48X3024X3048X3024x30HT30x48HT24x30HT24x30 36Ø HT24x3024x30 30X30 24x30 30X30 36X36 48X3024X30 30X30 36X36 30X30 30X30 32X24 36Ø TO-GO POS/ RESET RESET EP EP COOLER COOLER HOOD 32X24 32X48FURNITURE PLAN A-801 ACCESSIBILITY NOTES: 1. ALL TABLES SHOWN ARE STANDARD 30" HEIGHT AND ALL SEATING IS INTERCHANGEABLE FOR ACCESSIBILITY REQUIREMENTS. Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:08/20/2021www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...BR/ LEPERMIT SET 08.20.2021 AMMSOCIAL CANTINATHE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10 CARMEL, IN 46032PHANOMEN/ design 24 x 32PHANOMEN/ designPATIO1 2 3 4 5 6 7 10 12 PROVIDED BY NO LOCATION DIMENSIONS FURNITURE KEY DESCRIPTION REMARKS OUTDOOR TABLE PATIO OUTDOOR CHAIRS ENTRY 102 QTY 1 2 DINING 103 2 2 2 17 PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design 15 11 PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design 13 PHANOMEN/ design 14 PHANOMEN/ design 16 18 PHANOMEN/ design 19 PHANOMEN/ design 20 PHANOMEN/ design 8 PHANOMEN/ design 9 PHANOMEN/ design 22 PHANOMEN/ design 23 24 PHANOMEN/ design 21 PHANOMEN/ design 25 N S WE 1 TYP. 2 TYP. PATIO PATIO PATIO PATIO 32X48 32X32 36 DIA. 32X32 OUTDOOR TABLE OUTDOOR TABLE W/ UMBRELLA OUTDOOR TABLE OUTDOOR TABLE HIGH TOP PATIO PATIO PATIO PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design PHANOMEN/ design 36 DIA. OUTDOOR TABLE OUTDOOR BAR STOOLS 30X84 OUTDOOR PICNIC TABLE - - 2 4 7 2 5 1 78 14 32X108PHANOMEN/ design 1 PATIO OUTDOOR FAMILY TABLE VEST. 101 ENTRY 102 DINING 103 RESTROOM 104 RESTROOM 105 BAR 106 DINING 107 PRIVATE DINING 108 KITCHEN 109 OFFICE 111 TRASH 110 PATIO PATIO 2 TYP. 3 TYP. 4 TYP. 5 TYP. 6 7 8 10 TYP. 9 TYP. 9 TYP. 9 TYP. 9 TYP. 9 TYP. VEST. 101 1 PHANOMEN/ design BENCH SHELVES WOOD TABLE, TB1136" X 48" 13 TYP. ROUND BOOTHS- DINING 103 14 TYP. DINING 103 &107 FLIP UP WOOD TABLE, TB136X36 30X30 WOOD TABLE, TB2DINING 103 5 DINING 103 &107 24X30 DINING 103 &107 24X30 WOOD TABLE, TB3 HIGH TOP WOOD TABLE, TB4 DINING 103 &107 30X48 DINING 103 30X48 WOOD TABLE, TB5 HIGH TOP WOOD TABLE, TB6 BLACK UPHOLSTERED SEAT/BACK SCOOPPRIVATE DINING 108 & DINING 107 HIGH TOP STOOLS - BACK UPHOLSTERED, BS2 CHAIRS - SEAT/BACK UPHOLSTERED- - DINING 103 &107 DINING 103 & 107 6 5 4 1 DINING 107 32X120 WOOD FAMILY TABLE, TB7 PRIVATE DINING 108 36X36 WOOD TABLE, TB8 PRIVATE DINING 108 24X36 WOOD TABLE CHAIRS - SEAT/BACK UPHOLSTEREDPRIVATE DINING 108 26 27 28 29 - - BAR 106 36 DIA. WOOD TABLE; TB10 BAR 106 BLACK UPHOLSTERED SEAT/BACK SCOOP- BAR STOOLS, BS1- BAR 106 BAR 106 BOOTHS BANQUETTE (ON PLATFORM)DINING 103 30 31 32 56 10 1 4 24 4 24 1 1 14 1 3 BANQUETTEDINING 103 33 1 30X48 - 11 12 15 15 16 TYP. 17 TYP. 17 TYP. 18 TYP. 18 TYP. 19 TYP. 19 TYP. 20 21 TYP. 21 TYP.21 TYP. 21 TYP. 21 TYP. 21 TYP.21 TYP. 22 TYP. 22 TYP. 23 24 TYP. 25 TYP. 25 TYP. 26 TYP. 27 TYP. 35 TYP. 28 22TYP. 30 TYP. 31 TYP. 34 BAR 106 3 WOOD TABLE, TB5 32 TYP. 33 34 SCALE: 1/8"=1'-0" FLOOR PLAN1 0 5 10 20 40 PHANOMEN/ designPRIVATE DINING 108 48X36 WOOD TABLE, TB124 35 SEAT: UPH1, BACK: UPH8 09/23/21 09/23/21 09/23/21 NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E101 ELECTRICAL SCHEDULES & DETAILS ELECTRICAL SYMBOL SCHEDULE ELECTRICAL SPECIFICATION: GENERAL REQUIREMENTS THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS, FEEDER CONNECTION POINTS, AND EQUIPMENT REQUIREMENTS FOR EQUIPMENT PROVIDED BY OTHERS BY VISITING THE JOB SITE AND EXAMINING THE INSTALLATION DOCUMENTS, AND IS TO REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO BIDDING. ELECTRICAL CONTRACTOR SHALL VERIFY FINAL EQUIPMENT REQUIREMENTS AND LOCATION PRIOR TO ROUGH-IN. ANY MATERIAL OR LABOR WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AS DESCRIBED IN THESE DRAWINGS SHALL BE PROVIDED AS PART OF THIS CONTRACT. ALL EQUIPMENT DEVICES AND ELECTRICAL SUPPLIES SHALL BE LISTED IN A MANNER RECOGNIZED BY THE NATIONAL ELECTRIC CODE WHERE APPLICABLE. MANUFACTURER AND NEC REQUIRED CLEARANCES SHALL BE MAINTAINED AROUND EQUIPMENT. THESE CLEARANCES SHALL BE CONFIRMED BEFORE INSTALLATION. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL LOCAL CODES, OBTAINING NECESSARY PERMITS, PAYING REQUIRED FEES, AND MAKING ALL ARRANGEMENTS FOR NECESSARY INSPECTIONS, TESTS, ETC. ALL WORK SHALL COMPLY WITH OSHA STANDARDS AS WELL AS COMPLY WITH LOCAL REGULATIONS. COORDINATE INSTALLING OF ELECTRICAL MATERIALS WITH GENERAL CONSTRUCTION WORK. PROVIDE FIRESTOPPING TO CABLE AND RACEWAY PENETRATIONS OF FIRE-RATED FLOORS AND WALLS TO MAINTAIN FIRE RATING. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. INSTALL EQUIPMENT IDENTIFICATION LABELS ON EACH UNIT OF EQUIPMENT IN POWER, LIGHTING, COMMUNICATION, SIGNAL, AND ALARM SYSTEMS, INCLUDING THE MAIN UNIT OF EACH SYSTEM. USING ½” HIGH WHITE LETTERS ON BLACK ENGRAVED PLASTIC LAMINATE, PROVIDE A 1 ½” HIGH LABEL FOR ONE LINE OF TEXT OR A 2” HIGH LABEL FOR TWO LINES. PROVIDE CIRCUIT IDENTIFICATION ON EACH POWER OR COMMUNICATION CIRCUIT IN EACH VAULT, PULL, AND JUNCTION BOX AND SWITCHBOARD OR PANEL. INSTALL ENGRAVED PLASTIC-LAMINATED INSTRUCTION SIGNS WITH APPROVED LEGEND WHERE INSTRUCTIONS ARE NEEDED FOR SYSTEM OR EQUIPMENT OPERATION. ANY DEVIATION FROM SPECIFIED PRODUCT MANUFACTURER MUST BE APPROVED IN WRITING BY THE ENGINEER PRIOR TO BIDDING. ALL EQUIPMENT IN OUTDOOR LOCATIONS SHALL BE WEATHERPROOF. ALL WORK SHALL BE DONE IN A NEAT AND PROFESSIONAL MANNER. ANY UNSATISFACTORY WORKMANSHIP SHALL BE REMOVED AND REPLACED BY AND AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. INSPECT FINISHED WORK. CUT, PATCH, REFINISH, CLEAN AND TOUCH-UP AS NEEDED. UPON COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL INSTALLATION SHALL BE TESTED AND DEFECTS CORRECTED. THE CONTRACTOR SHALL GUARANTEE FOR ONE YEAR THAT ALL WORK IS FREE OF DEFECTS AND SHALL CORRECT ANY DEFECTIVE WORK FOUND DURING THAT PERIOD, AS WELL AS ANY DAMAGE RESULTING FROM SAID DEFECT. SUBMITTALS PROVIDE MANUFACTURER'S LITERATURE ON ALL ELECTRICAL EQUIPMENT. THE FOLLOWING SHALL BE INCLUDED WHERE APPLICABLE: 1. STANDARD SCHEMATIC DRAWINGS, MODIFIED FOR SPECIFIC MODEL AND ACCESSORIES PROVIDED. 2. CUT SHEETS IDENTIFYING PERTINENT MATERIALS AND PRODUCTS REQUIRED. 3. EQUIPMENT DIMENSIONS, SHIPPING SPLITS, AND CONSTRUCTION CLEARANCES. 4. MAINTENANCE REQUIREMENTS. 5. PERFORMANCE SPECIFICATIONS. 6. WIRING AND CONTROL DIAGRAMS. 7. SAFETY INSTRUCTIONS. 8. THE FULL MANUFACTURER'S MODEL NUMBER SHALL BE CLEARLY SHOWN ON THE TOP OF THE FIRST AND THE BOTTOM OF THE LAST PAGE. 9. IDENTIFICATION OF COLOR OR FINISHES. 10. THE CONTRACTOR'S STAMP, SIGNATURE, AND CONTACT DATA SHALL BE AFFIXED TO EACH SUBMITTAL. 11. WARRANTY INFORMATION AND SERIAL NUMBER. AN OPERATIONS MANUAL CONTAINING EQUIPMENT DRAWINGS AND RELATED INFORMATION, INCLUDING THE DATA LISTED ABOVE, SHALL BE SUBMITTED TO THE OWNER AFTER PROJECT COMPLETION. RECORD DRAWINGS, OR “AS BUILTS”, SHALL BE PROVIDED WITH THE OPERATIONS MANUAL. THE MANUAL SHALL BE LABELED WITH THE PROJECT NAME AND LOCATION AND SHALL CONTAIN THE NAMES AND ADDRESSES OF THE OWNER, ENGINEER, AND CONTRACTOR. DATA PROVIDE ¾” CONDUIT WITH PULL WIRE TO CEILING FOR ALL DATA AND COMMUNICATIONS UNLESS OTHERWISE SPECIFIED. DO NOT RUN COMMUNICATION CONDUIT PARALLEL TO POWER CONDUIT WITHIN 6” OF POWER CONDUIT. AVOID AREAS OF POWER OR MAGNETIC INTERFERENCE. CONDUITS AND WIRING ALL CONDUIT SHALL BE ¾” MINIMUM RIGID GALVANIZED STEEL OR ELECTRIC METALLIC TUBING. ALL CONUIT IN BELOW 12' SHALL BE RIGID CONDUIT. RIGID CONDUIT OR SCHEDULE 40 PVC SHALL BE USED UNDER SLAB. FLEXIBLE STEEL CONDUIT SHALL BE USED FOR CONNECTIONS TO LIGHTING FIXTURES AND WHERE SHORT CONNECTIONS MAKE RIGID CONDUIT IMPRACTICAL. MC CABLE MAY BE USED ABOVE CEILINGS AND IN WALLS BOTH HORIZONTALLY AND VERTICALLY. GALVANIZED STEEL CONDUIT SHALL USE THREADED FITTINGS. EMT FITTINGS SHALL BE COMPRESSION TYPE. ALL CONDUIT SHALL BE CONCEALED. SUPPORT CONDUIT AT NOT MORE THAN 5' CENTERS. HANGERS AND SUPPORTS LISTED FOR THE PURPOSE SHALL BE USED TO SUPPORT ELECTRICAL DEVICES. THESE SHALL BE FASTENED TO THE BUILDING STEEL, CONCRETE OR MASONRY. HANGERS SHALL NOT INTERFERE WITH ACCESS TO EQUIPMENT. ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL COMPLY WITH THE NEC. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12” IN LENGTH, NOR GREATER THAN 36” IN LENGTH. CONDUCTORS SHALL BE COPPER THWN #12 MINIMUM CONDUCTORS FOR FEEDERS OF 100 AMPS OR GREATER MAY BE ALUMINUM. THHN MAY BE USED ABOVE GRADE IN INTERIOR LOCATIONS ONLY. MAJOR FEEDERS FROM THE SWITCHBOARD PANELS TO PANELBOARDS, FEEDERS FROM/TO TRANSFORMERS, AND FEEDS TO 208V PANELS MAY NOT BE SHOWN ON THE PLANS. THESE FEEDERS ARE PART OF THE WORK, AND SHALL BE INSTALLED AS INDICATED ON THE ONE LINE DIAGRAM. HVAC CONTROL WIRING FURNISHED AND INSTALLED BY DIVISION 15. WIRE OUTLETS WITH AT LEAST 6 INCHES OF SLACK. OUTLET BOXES SHALL BE A MINIMUM OF 4” x 2 1/8” x 2 1/8” FOR SINGLE GANG AND 4” x 4” x 2 1/8” FOR TWO GANG. ALL CIRCUITS SHALL HAVE AN INSULATED EQUIPMENT GROUND CONDUCTOR, IN ADDITION TO GROUND CONTINUITY OF THE CONDUIT SYSTEM. RECEPTACLES SHALL BE INDUSTRIAL SPECIFICATION GRADE RATED 20A UNLESS OTHERWISE INDICATED. JUNCTION AND PULL BOXES SHALL BE RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE, SUPPORTED INDEPENDENTLY FROM THE CONDUIT SYSTEM, AND SHALL BE LABELED WITH CIRCUIT NUMBER AND SYSTEM TYPE ON COVER. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. EMPTY CONDUITS SHALL BE TERMINATED WITH A SUITABLE CAP. ALL CONDUIT CONNECTIONS TO OTHER CONDUITS, BOXES AND EQUIPMENT SHALL BE PROVIDED WITH APPROPRIATE FITTINGS. PROVIDE PULL WIRE IN ALL CONDUITS. CIRCUIT BREAKERS CIRCUIT BREAKERS SHALL BE QUICK-MAKE, QUICK-BREAK, PLUG-ON CIRCUIT BREAKERS, 20A MINIMUM. ALL MULTIPLE BREAKERS SHALL BE COMMON TRIP. BALANCE LOADCENTERS TO WITHIN 10% AND ADJUST LABELING AND AS-BUILT DRAWINGS ACCORDINGLY. FUSES AND DISCONNECTS DISCONNECTS SHALL BE EXTERNALLY OPERATED, HEAVY-DUTY METAL ENCLOSED, AND SIZED TO PROTECT THE DESIGNATED LOAD. EACH FUSED DISCONNECT SHALL BE PROVIDED WITH A COMPLETE SET OF UL CLASS RK5 DUAL ELEMENT FUSES FOR MOTOR LOADS AND UL CLASS RK1 FOR RESISTIVE LOADS. PROVIDE SPARE FUSES OF EACH SIZE AND TYPE. MOTORS ALL MOTORS SHALL BE PROVIDED WITH INTEGRAL OVERLOAD PROTECTION. GROUNDING PROVIDE A COMPLETE GROUNDING CONDUCTOR SYSTEM AS REQUIRED BY THE NEC AND LOCAL CODES. ALL CONDUIT SHALL BE GROUNDED WITH A GREEN GROUNDING CONDUCTOR. PROVIDE BONDING JUMPERS WITH PLUMBING SYSTEM, COORDINATING WITH PLUMBING CONTRACTOR. BOND EXISTING SWITCHBOARD TO NEW FOUNDATION STEEL. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL JUNCTION BOXES, OUTLET BOXES, AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. OUTLET BOXES SHALL BE BONDED WITH A BONDING JUMPER. ALL ENCLOSURES AND NON-CURRENT-CARRYING METAL PARTS ARE TO BE GROUNDED. CONDUITS ARE TO BE ELECTRICALLY CONTINUOUS. LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES. GROUND WIRES SHALL BE PROTECTED FROM MECHANICAL INJURY. LIGHTING LIGHTING SHALL BE EXACT MODEL NUMBERS AS SHOWN ON THE SCHEDULE UNLESS A COMPLETE ALTERNATE PACKAGE IS SUBMITTED AND APPROVED BEFORE BIDDING. PROVIDE AUXILIARY SUPPORTS AS REQUIRED BY LOCAL CODES. COMPLY WITH LOCAL SEISMIC REQUIREMENTS. PROVIDE FIRE RATED DRYWALL BOXES IN FIRE RATED CEILINGS. FIELD COORDINATE FIXTURES WITH OTHER SYSTEMS TO AVOID CONFLICT. COMPLY WITH LOCAL ENERGY CODES. PROVIDE SPECIAL HOUSINGS WHERE REQUIRED TO COMPLY WITH APPLICABLE CODE REQUIREMENTS. FIRE ALARM POVIDE NEW ADDRESSIBLE FIRE ALARM SYSTEM THROUGHOUT NEWTENANT. PROVIDE MINIMUM #14 COPPER WIRING FOR VISUAL NOTIFICATION DEVICES. 09/23/21 NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E102 ELECTRICAL SCHEDULES & DETAILS 09/23/21 NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E103 ELECTRICAL SCHEDULES & DETAILS 09/23/21 32X32 32X32 32X32 60X36 60X36 32X4832X48POS 32X108 HOST 32X4830x84 32X3232X32 24x30TV TV30x48 30x48 30x48 SUPPLY MAKE-UP 30x48 24x30 48X3024X3048X3024x30HT30x48HT 24x30HT24x30 36Ø HT24x3024x30 30X30 24x30 30X30 36X36 48X3024X30 30X30 36X36 30X3030X30 32X4832X4836Ø TO-GO RESET SOCIALR1 R1 R1 T1 T1 T1 T1 T1 P1 P1 T1 W2 P3 W2 W3 P1 W2 S1 S1 S1 S1 S1 S1 S1 S1 S1 W4 W4 W5 W6 P1 P1 W3 S3 S3 P1 P1 S2 W4 L1 L1 L1 L1 L1 L1 S5 S5 S5 L1 L1 L1 EM3 EM1 EM1 EM2 EM3 EM3 W7 T2 R1 R1 R1 R1 S2 S2 S4 S4 W7 NL H1 H1 H1 H1 H1 H1 H1 H1 R4 R4 R4 R4 R4 R4 W7 R4 R4 R4 R4 R4 R4 R4 R4R4 FAN1FAN1 S1 S1 EXISTING AWNING EXISTING AWNING EXISTING AWNING NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E201 NORTH FLOOR PLAN - LIGHTING 09/23/21 3 YDDUMPSTER3 YD DUMPSTER TRASH CO2OIL TANK36"X72"32X48 32X32 32X32 OFFICE 48X3636x36 TV TV 48X36 36x36 24X3648X3636x36 POS/ RESET24X3636x36 48X36 24X36 24X36 36Ø HT 32X48 32X24 32X24 32X24 36Ø HT 32x120 24x30 HT 24x30 HT 24x30 HTTV36X36 32X24 36Ø POS/ RESET EP EP COOLER COOLER HOOD W1 W1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 R1 R1 R1 R3 R3 R3 P1 P1 P1 P1P1 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 P2 P2 R2 W3 L1 EM1 EM1 EM1 EM1 EM1 EM1 EM2 EM2 EM3 EM3 W7 R3 R3 R3 R3 R3 EXISTING VERTICAL SHAFT S4 S4 W7 FP1 FP1 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 NL NL NL EM1 EM2 EXISTING AWNING EXISTING AWNING EXISTING AWNING S6 S6 S6 S6 S6 S6 EM3 NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E202 SOUTH FLOOR PLAN - LIGHTING 09/23/21 3 YDDUMPSTER3 YD DUMPSTER TRASH CO2OIL TANK36"X72"32X32 32X32 32X32 32X48 32X32 32X32 OFFICE 60X36 60X36 48X3636x36 TV TV 48X36 36x36 24X3648X3636x36 POS/ RESET24X36 36x36 48X36 24X36 24X36 32X4832X48POS 32X108 36Ø HT 32X48 HOST 32X24 32X24 32X2432X4830x84 32X3232X32 36Ø HT 32x120 24x30 HT 24x30 HT 24x30 HTTV TV30x48 30x48 30x48 SUPPLY MAKE-UP 30x48 24x30 48X3024X3048X3024x30HT30x48HT24x30HT24x30 36Ø HT24x3024x30 30X30 24x30 30X30 36X36 48X3024X30 30X30 36X36 30X3030X30 32X2432X4832X4836Ø TO-GO POS/ RESET RESET EP EP COOLER COOLER HOOD NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E301 FLOOR PLAN - POWER 09/23/21 3 YDDUMPSTER3 YD DUMPSTER TRASH CO2OIL TANK36"X72"OFFICE 48X36TV TV 48X36 24X3636x36 POS/ RESET36x36 24X36 24X36 32x120TV TV30x48 30x48 30x48 SUPPLY 24X3036X36 POS/ RESET EP EP COOLER COOLER HOOD NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E302 ENLARGED KITCHEN PLAN - POWER 09/23/21 3 YDDUMPSTER3 YD DUMPSTER TRASH CO2OIL TANK36"X72"32X32 32X32 32X32 32X48 32X32 32X32 OFFICE 60X36 60X36 48X3636x36 TV TV 48X36 36x36 24X3648X3636x36 POS/ RESET24X36 36x36 48X36 24X36 24X36 32X4832X48POS 32X108 36Ø HT 32X48 HOST 32X24 32X24 32X2432X4830x84 32X3232X32 36Ø HT 32x120 24x30 HT 24x30 HT 24x30 HTTV TV30x48 30x48 30x48 SUPPLY MAKE-UP 30x48 24x30 48X3024X3048X3024x30HT30x48HT24x30HT24x30 36Ø HT24x3024x30 30X30 24x30 30X30 36X36 48X3024X30 30X30 36X36 30X3030X30 32X2432X4832X4836Ø TO-GO POS/ RESET RESET EP EP COOLER COOLER HOOD NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E401 FLOOR PLAN - FIRE ALARM 09/23/21 3 YDDUMPSTER3 YD DUMPSTER TRASH CO2OIL TANK36"X72"32X32 32X32 32X32 32X48 32X32 32X32 OFFICE TV TVPOS/ RESET32X4832X48POS 32X108 36Ø HT 32X48 HOST 32X24 32X24 32X2432X4830x84 32X3232X32 36Ø HTTV TV30x48 30x48 30x48 SUPPLY MAKE-UP 32X2432X4832X4836Ø TO-GO POS/ RESET RESET EP EP COOLER COOLER HOOD H1 H1 H1H1 H1 H1 H1 H1 H1 NO. REVISIONS DATE DESCRIPTION ISSUE REVIEW BIDDING PERMIT CONSTRUCTION THE RAILYARD AT MIDTOWN350 MONON BLVD., SUITE 10CARMEL, IN 46032SOCIAL CANTINA% 'RGG PROJECT NUMBER SCALE DRWN BY DATE AS NOT('   SHEET TITLE Engineering & Contractors, Inc Design & Build Electrical A TENANT IMPROVEMENT FOR:8/13/21 E501 FLOOR PLAN - HVAC CONNECTIONS 09/23/21 09/23/21 09/23/21 09/23/21 09/23/21 09/23/21 09/23/21 09/23/21 09/23/21