DEMOLITION
REFLECTED
D1.1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
DEMOLITION FLOOR PLAN 1/4"=1'-0" 1
N
TYPICAL EXISTING WALL TO REMAIN. PROTECT FROM DAMAGE. REFER TO BALANCE OF
DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING EQUIPMENT, FIXTURE, FURNITURE, ETC. TO REMAIN. PROTECT FROM DAMAGE.
REFER TO BALANCE OF DRAWINGS FOR ADDITIONAL INFO.
DEMOLITION ITEMS AS INDICATED (SEE KEY NOTES)
CEILING PLAN
GENERAL NOTES WALL LEGEND
1. DRAWINGS OF EXISTING CONDITIONS HAVE BEEN COMPILED FROM EXISTING DATA SUPPLIED BY THE OWNER TO
THE ARCHITECT. THE ARCHITECT MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED FOR THE ACCURACY OF
THE COMPLETENESS OF THE EXISTING INFORMATION RECORDED. THE CONTRACTOR SHALL FIELD VERIFY ALL
EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT
MIGHT ARISE IN THE COURSE OF THE DEMOLITION WORK.
2. THE OWNER RESERVES THE RIGHT TO SALVAGE ANY DEMOLISHED ITEM. VERIFY ITEMS TO BE SALVAGED WITH THE
OWNER PRIOR TO THE START OF DEMOLITION. REMOVE, PROTECT, CLEAN, REPAIR FOR REUSE AND TURN OVER
SUCH ITEMS AS DIRECTED BY THE OWNER.
3. DEMOLITION & REMOVAL OF SYSTEMS NOTED INCLUDES ALL WORK REQUIRED TO ACHIEVE SCOPE OF NEW WORK
AND DESIGN INTENT.
4. THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING CONDITIONS CAUSED BY CONTRACTOR OR
SUBCONTRACTORS, AND SHALL REPAIR ANY DAMAGES TO TENANT'S SATISFACTION. DURING CONSTRUCTION
CONTRACTOR TO PROTECT ADJACENT SURFACE FINISHES TO REMAIN AS REQUIRED.
5. WHERE WALLS, FINISHES, ETC. ARE REMOVED, REMAINING SURFACES ARE TO BE REPAIRED FOR NEW
CONSTRUCTION / FINISHES.
6. INSPECT INTERIOR AND EXTERIOR WALLS. REPLACE ANY DAMAGED SUBSTRATE WALLS, ETC. INSPECT DINING
ROOM WINDOWS & WALLS BELOW WINDOWS FOR EVIDENCE OF MOISTURE DAMAGE & IMPROPERLY INSTALLED
FLASHING. NOTIFY ARCHITECT AND TENANT IMMEDIATELY IF ANY DAMAGE IS FOUND.
7. SEE SITE PLAN FOR ANY SITE DEMOLITION WORK.
8. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL DEMOLITION WORK.
9. SEE MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS FOR MECHANICAL, ELECTRICAL, PLUMBING DEMOLITION
WORK.
KEY NOTES
1 EXISTING CEILING AT BACK OF HOUSE TO REMAIN, U.N.O.
PROTECT FROM DAMAGE. SEE REFLECTED CEILING PLAN FOR
ADDITIONAL INFORMATION.
AT AREA SHOWN HATCHED - EXISTING CEILING GRID TO REMAIN.
SEE REFLECTED CEILING PLAN FOR NEW WORK REQUIRED.
EXISTING CEILING TILES TO BE REMOVED AND REPLACED WITH
NEW AS SCHEDULED.
EXISTING SOFFIT TO BE REMOVED. PATCH ADJACENT FINISHES TO
REMAIN.
EXISTING SOFFIT TO REMAIN. PROTECT FROM DAMAGE.
EXISTING METAL PANEL CEILING IN DRY STORAGE / COOLER /
FREEZER TO REMAIN. PROTECT FROM DAMAGE.
EXISTING EXHAUST HOOD TO REMAIN. PROTECT FROM DAMAGE.
EXISTING CEILING GRID,TILES, LIGHT FIXTURES AND MECHANICAL
REGISTERS ABOVE SERVING AREA TO BE REMOVED. SEE
REFLECTED CEILING PLAN FOR NEW WORK REQUIRED THIS AREA.
PORTION OF EXISTING BACK OF HOUSE CEILING GRID AND TILES
TO BE REMOVED AS REQUIRED FOR NEW WALL CONSTRUCTION
SCHEDULED. SEE REFLECTED CEILING PLAN FOR ADDITIONAL
INFORMATION.
EXISTING FLOATING A.C.T. CEILING AND ASSOCIATED LIGHTING TO
BE REMOVED IN ITS ENTIRETY.
EXISTING LIGHTING IN BACK OF HOUSE TO BE REMOVED AND
REPLACED WITH NEW LED FIXTURES. SEE REFLECTED CEILING
PLAN FOR ADDITIONAL INFORMATION.
EXISTING EXIT LIGHT TO BE REMOVED AND REPLACED WITH NEW.
SEE REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION.
EXISTING LIGHT FIXTURES IN DRY STORAGE / COOLER / FREEZER
TO BE REMOVED AND REPLACED WITH NEW LED FIXTURES TO
MATCH EXISTING.
EXISTING BACK OF HOUSE MECHANICAL REGISTERS TO BE
REMOVED AND REPLACED WITH NEW.
EXISTING FRONT OF HOUSE MECHANICAL REGISTERS TO BE
REMOVED. EXISTING DUCTWORK TO BE REUSED. SEE A204 AND
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING RESTROOM CEILING, LIGHTING, MECHANICAL REGISTERS
AND SPEAKER TO BE REMOVED. SEE REFLECTED CEILING PLAN
FOR ADDITIONAL INFORMATION.
EXISTING PENDANT LIGHT TO BE REMOVED.
EXISTING LIGHT FIXTURES ATTACHED TO STRUCTURE TO BE
REMOVED. SEE REFLECTED CEILING PLAN FOR ADDITIONAL
INFORMATION.
EXISTING FABRIC AWNINGS TO BE REMOVED AND REPLACED WITH
NEW AS SCHEDULED. SEE EXTERIOR ELEVATIONS FOR ADDITIONAL
INFORMATION.
NOT USED.
EXISTING AWNING TO BE REMOVED IN ITS ENTIRETY. PATCH AND
REPAIR EXISTING ADJACENT FINISHES SCHEDULED TO REMAIN AS
REQUIRED.
AREA OF REMOVED/RELOCATED COOLER/FREEZER WALL AND
DOOR. PATCH/REPAIR COOLER CEILING AS REQUIRED.
NOT USED.
EXISTING FAN COIL TO BE RELOCATED AS REQUIRED FOR NEW
LOCATION OF COOLER/FREEZER WALL. EVALUATE AND MODIFY AS
REQUIRED FOR NEW FREEZER SIZE.
EXISTING FAN COIL LOCATION. EVALUATE AND MODIFY AS
REQUIRED FOR NEW COOLER SIZE.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
09/23/21