HomeMy WebLinkAbout2-Taco Bell - 08.06.2021 - A0.1 Site Details9'-6"MATCHEXISTING2'-2" 1'-0"FACE OF CURB
CLEARANCE BAR, SEE
6/A0.1 FOR FOOTING
DETAIL. PLACE IN SAME
POSITION AS EXISTING
HEIGHT BAR SCHEDULED
TO BE REMOVED.
6" DIA. CONCRETE FILLED
30" HIGH BOLLARD. SEE
DETAIL 3/A0.1.
EXISTING CAP
FLASHING TO
REMAIN
EXISTING BRICK
VENEER TO REMAIN
EXISTING CONCRETE
BLOCK TO REMAIN
EXISTING GATE POST
TO REMAIN
EXISTING GATE POST
TO REMAIN
EXISTING GATE POST
TO REMAIN
EXISTING BRICK
VENEER TO REMAIN
EXISTING CONCRETE
BLOCK TO REMAIN
EXISTING GATE
FRAMING, SHOWN
DASHED, TO REMAIN.
GATE FINISH TO BE COMPOSITE PVC DECKING 1X6
SQ. EDGE W/ 1/8" MIN. GAP. (COLOR: LIGHT GRAY -
COORDINATE WITH FLYNN RESTAURANT GROUP
AND CITY REQUIREMENTS). SECURE WITH 2 COATED
DECK SCREWS AT EACH TOP, BOTTOM AND
MID-POINT FRAMING MEMBERS - COUNTERSINK.
SQ. CUT AT TOP AND BOTTOM - LENGTH OF NEW
PVC DECKING TO BE THE SAME AS THE EXISTING
FINISH SCHEDULED TO BE REMOVED.
EXISTING GATE
FRAMING, SHOWN
DASHED, TO REMAIN.
NOTES:
1. ALL AREAS OF THE MENU BOARD MUST BE VISIBLE
TO THE DRIVER LOCATED AT THE SPEAKER POST.
ASSUME DRIVERS LOCATION IS 24" FROM FACE OF
CURB, CENTERED ON THE SPEAKER POST.
2. CENTER OF MENU BOARD TO BE 5'-6" TO 9'-0" FROM
DRIVERS POINT OF VIEW.
3. PROVIDE (2) 1" CONDUITS FROM BUILDING TO
SPEAKER POST FOR LOW VOLTAGE WIRING.
DIGITAL MENU BOARD (60.7"
WIDE) WITH FRONT SWING
UP ACCESS. SEE 6/A0.1 AND
2/A0.2 FOR FOUNDATION
DETAILS.
6" DIA. CONCRETE FILLED 30"
HIGH BOLLARD. SEE DETAIL
3/A0.1.
SPEAKER POST WITH
DRIVE-THRU HEARING
IMPAIRED SIGNAGE, SEE
2/A0.1 FOR FOOTING DETAIL.
CANOPY, SEE DETAIL 2/A0.1
FOR FOOTING DETAIL
OUTLINE OF CANOPY ABOVE
FACE OF CURB
80'-0"TO CENTER OF DRIVE-THRU WINDOW℄3'-7" 2'-6"1'-0"
1'-4" 2'-10"
2'-8"℄℄ ℄ ℄
℄
7
7
°
ESTIMATED POSITION OF
DRIVERS HEAD ALIGNED
WITH CENTER OF
SPEAKER POST
SITE
DETAILS
A0.1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
N
ENLARGED MENU BOARD DETAIL 3/8"=1'-0" 1
SCOPE OF WORK FOR DIGITAL MENU BOARD INSTALL AND VENDORS
∂ RSCS TO SUPPLY DIGITAL MENU BOARD AND CABLE
∂ SIGN VENDOR TO SUPPLY ANCHOR BOLTS AND BOLT PATTERN TO G.C.
∂ SITE SURVEY - SIGN VENDOR.
REMODEL (SUCCESSOR MANDATORY - MIDTERM OPTIONAL FOR FZ)
1. EXISTING FOOTING (SKIP TO STEP 4) - SIGN VENDOR.
2. TRENCHING / CONDUIT - SIGN VENDOR
3. FORMING / FOUNDATION / ANCHOR-BOLTS (SKIP TO STEP 5) - SIGN VENDOR.
4. ANCHOR BOLTS - SIGN VENDOR.
5. DIGITAL MENU BOARD INSTALL - SIGN VENDOR
6. DIGITAL MENU BOARD CABLE PULL - SIGN VENDOR
7. DIGITAL MENU BOARD FINAL CONNECTION AND SYSTEM CHECK - SIGN
VENDOR.
REMODEL NEW BUILDING RETROFIT
FOUNDATION IS FURTHER
THAN 6'
USING EXISTING
FOUNDATION (ALTHOUGH
NOT RECOMMENDED
INTEGRATED CANOPY
EXISTS
BOLLARDS NEEDED - DO
NOT PLACE IN FRONT OF
MENU BOARD
RECOMMEND NEW FOUNDATION
WORK FOUNDATION PERFORMED
BY G.C.
-
-
WORK PERFORMED BY SIGNAGE
INSTALLER
N/A
N/A
N/A
WORK PERFORMED BY
SIGNAGE INSTALLER
RECOMMEND NEW
FOUNDATION WORK
PERFORMED BY G.C.
-
-
WORK PERFORMED BY
SIGNAGE INSTALLER
MENU BOARD SCOPE OF WORK
CANOPY AND SPEAKER FOOTINGN.T.S. 2
BOLLARD AT DRIVE-THRU 3/4"=1'-0" 3 CLEARANCE BAR PLACEMENT DETAIL3/8"=1'-0"4
CLEARANCE BAR FOOTING N.T.S. 5 MENU FOUNDATION N.T.S. 6 TRASH ENCLOSURE ELEVATION3/8"=1'-0"7
N
COORDINATE FOUNDATION / ANCHOR BOLT
REQUIREMENTS WITH DIGITAL MENU BOARD
SUPPLIER AS REQUIRED FOR INSTALLATION
ON SPECIAL FOUNDATION WITH BRICK
VENEER AND CONCRETE SILL BLOCK TOP.
SEE 2/A0.2.