HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A1.0 Floor PlanW/H
2X4
2X42X4 2X4 2X4 2X62X62X62X42X42X4
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
2
A8.1
2
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
OFFICE
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S
SERVING
VESTIBULE #2
1
2
3
4
5
6 7
8
1
A4.1
1
A4.0
2
A4.1
3
A4.1ALIGN5
TYP.
5
TYP.
5
TYP.
5
TYP.
6
6
10
14
13
12
9 9
1
2 4 A8.0
1
2
1
3 A8.2
5
4
6
4 A8.2
7
9
10
12 A8.2
2
4
3
5 A8.3
13
118 A8.2
PASSAGE
1
A8.3
3
5 A8.0
6
7
10
A8.0
MEN'S
4
11ALIGNALIGNALIGN14
14
1
A8.1 8'-7 1/2"3'-6"
9'-6 1/2"13'-7" 3'-8 1/4" 6'-0 1/2"8A
A8.0
8B
A8.0
18
A6.3
7'-2"
7
7
15
3'-0"
FLOOR
PLAN
A1.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
WALL LEGEND FLOOR PLAN NOTES
KEY NOTES
1
FLOOR PLAN 1/4"=1'-0" 1
NOT USED.
EXISTING PIPE BOLLARD TO REMAIN.
NOT USED.
KEEP CLEAR FOR UTILITIES AND SYRUP LINES.
STAINLESS STEEL CORNER GUARD / WALL CAP (TM-2), TYP. ALL
CORNERS IN BACK OF HOUSE FROM REAR WALL TO THE KITCHEN
SIDE OF THE SERVICE COUNTER.
SYRUP LINE CHASE (ABOVE).
RELOCATED EXISTING WALK-IN COOLER / FREEZER SEPARATION
WALL AND DOOR. CONTRACTOR TO FIELD VERIFY EXISTING
LIGHTING, FAN COILS, CONDENSERS, ETC. AND MODIFY AS
REQUIRED FOR NEW WALL / DOOR LOCATION.
NOT USED.
EXISTING ELECTRICAL EQUIPMENT TO REMAIN. PROTECT FROM
DAMAGE.
DOOR OPTIONAL - COORDINATE WITH OWNER. PROVIDE CASED
OPENING IF NO DOOR CHOSEN PER 14/A6.1.
PROVIDE NEW ACOUSTIC BATT INSULATION AS NOTED IN THE
WALL LEGEND AT EXISTING WALLS IF NONE EXISTS.
NEW FRONT COUNTER ASSEMBLY BY FURNITURE / DECOR
VENDOR.
EXISTING OFFICE COUNTERTOP TO BE REMOVED AND REPLACED
WITH NEW. EXISTING WALL SHELVING TO REMAIN AS IS. PROTECT
FROM DAMAGE.
CORNER GUARD TILE SCHLUTER.
INFILL WINDOW OPENING WITH EXTERIOR WALL CONSTRUCTION
TO MATCH EXISTING ADJACENT CONDITIONS.
N
DIMENSIONS:
1. ALL DIMENSIONS ARE TO FACE OF SHEATHING U.N.O. FOR NEW WALLS. DIMENSIONS TO EXISTING WALLS ARE TO
FACE OF EXISTING SHEATHING.
2. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQUIRED. NET CLEARANCE FROM FACE OF WALL /
WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES WITH VENDOR PRIOR TO INTERIOR WALL FRAMING.
WINDOWS / DOORS:
1. SEE SHEET A1.1 FOR WINDOW TYPES AND DOOR SCHEDULE.
2. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING.
FINISH SUBSTRATES:
1. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN LIEU OF GYP. BD. AT ALL WALLS
EXCEPT SHEARWALL SURFACES, U.N.O.
2. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF
INTERNATIONAL" APPROVED SEALANTS.
3. ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE, U.N.O.
DECOR:
1. SEE A2.0 FOR SEATING PLAN AND DETAILS.
2. SEE A7.0 FOR FLOOR FINISHES.
3. SEE A8.0, A8.1, A8.2 AND A8.3 FOR WALL FINISHES.
4. SEE A7.1 FOR CEILING FINISHES.
GENERAL:
1. PROVIDE THREE FIRE EXTINGUISHERS - (2) 10 LB. BC AND (1) 10 LB. ABC - TO COMPLY WITH LOCAL FIRE CODE.
LOCATE PER DIRECTION OF FIRE MARSHALL OR LOCAL AUTHORIZING AGENT FOR ADDITIONAL INFORMATION SEE
SHEET A2.0.
2. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ON NON-BEARING INTERIOR
PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE.
2
3
4
5
6
7
8
9
10
11
12
13
14
WALL HEIGHTS:
ALL INTERIOR NON-BEARING WALLS GO TO BOTTOM OF TRUSS, U.N.O. REFER TO STRUCTURE.
WALL SUBSTRATES:
∂ DINING ROOM:
1/2" GYPSUM WALLBOARD FROM FLOOR SLAB TO 6" ABOVE CEILING HEIGHT U.N.O. SEE 6 & 8/A6.3 (NOTE: THE
CEMENT BOARD SPECIFICATION IS DESIGNED TO ALLOW THE G.C. FLEXIBILITY.)
∂KITCHEN WALLS:
1/2" CEMENT WALLBOARD FROM SLAB TO 12" A.F.F. AT 12" A.F.F., USE 1/2" CDX PLYWOOD WITH F.R.P. SURFACE
FINISH TO 6" ABOVE CEILING HEIGHT U.N.O. IF DOUBLE SIDE SHEAR WALL PLYWOOD IS SPECIFIED. THE
PLYWOOD SHALL BE CONTINUOUS FROM SILL PLATE TO TOP PLATE. SEE 4/A6.3.
∂RESTROOM WALLS:
5/8" CEMENT WALLBOARD FROM T.O. FULL HEIGHT OF TILE FINISH SCHEDULED WITH 5/8" HI-IMPACT BRAND XP
WALLBOARD, TYPE X CORE FROM T.O. CEMENT BOARD TO 6" ABOVE CEILING HEIGHT U.N.O. NO SUBSTITUTIONS
ALLOWED. FINISH AS SCHEDULED.
∂ALL OTHER FRAME WALL CONDITIONS:
1/2" CEMENT WALLBOARD FROM T.O. SLAB TO 12" A.F.F., WITH 1/2" GYPSUM WALLBOARD FROM T.O. CEMENT
BOARD TO 6" ABOVE CEILING HEIGHT U.N.O. FINISH AS SCHEDULED.
TYPICAL INTERIOR WALL: WOOD STUDS AT 16" O.C. AS INDICATED. (2X4, 2X6 OR 2X8 WOOD STUDS
AS INDICATED)
INTERIOR SOUND-RATED WALL: TYPICAL INTERIOR WALL WITH 3 1/2" OR 5 1/2", UNFACED
FIBERGLASS BATT INSULATION. (2X4 OR 2X6 WOOD STUDS AS INDICATED)
EXTERIOR WALL INFILL: INFILL WALL AS REQUIRED. NEW CONSTRUCTION TO MATCH EXISTING
ADJACENT WALL CONSTRUCTION. NEW TO BE FLUSH WITH EXISTING.
EXISTING WALL: EXISTING WALL PARTITION TO REMAIN. PROTECT FROM DAMAGE. PROVIDE NEW
WALL SUBSTRATE AS INDICATED.
EXISTING WALL - NEW INSULATION: EXISTING WALL PARTITION TO REMAIN. PROTECT FROM
DAMAGE. PROVIDE NEW 3 1/2" OR 5 1/2", UNFACED FIBERGLASS BATT INSULATION (2X4 OR 2X6
WOOD STUDS) AND WALL SUBSTRATE AS INDICATED.
15
09/23/21