Loading...
HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A1.1 Door-Wdw SchedulesFINISH FLOOR 3'-4"(34" MIN. TO48" MAX.)KICK PLATE ON PUSH SIDE ONLY SIGN WHERE REQUIRED PER 2009 A117.1 COAT HOOK ON INSIDE OF ROOM C 15 A6.1 15 A6.1 3'-4"(34" MIN. TO48" MAX.)KICK PLATE ON PUSH SIDE ONLY DOOR AND FRAME EPOXY PAINTED COLOR BOTH SIDES E P-4 C 6"3'-0" 6" 6"\A1;6"D 15 A6.1 15 A6.1 A B NOT USED NOT USED NOT USED DOOR & WINDOW ELEVATIONS A1.1 & SCHEDULES 9853 N MICHIGAN RD. CARMEL, IN 46032 TB21-10 GGD 08.06.2021PERMIT / BID: ISSUES AND REVISIONS: CHECKED BY: DRAWN BY: PROJECT NO.: KDI ENDEAVOR - REMODEL 62 SEATS / 3,011 +/- S.F. TACO BELL, CARMEL, IN A R C H I T E C T S 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com Rebecca L. Olson, AIA #AR11500059 IAN AI ND REGISTER E D REBECCAL.O L SONSTATE OF ARCHITEC T NO. AR11500059 DOOR SCHEDULE DOOR SCHEDULE NOTES NOTES 1. LAMINATE DOORS 6, 7, 8 & 9 AND PAINT FRAMES 6, 7, 8, 9 & 10. SEE INTERIOR ELEVATION, SHEET A8.0, A8.1 & A8.2. 2. ALL HARDWARE SHALL BE US32D U.N.O. 3. ALL HOLLOW METAL FRAMES SHALL BE 16 GA. STEEL U.N.O. 4. ALL LOCKS SHALL BE FALCON 6 PIN INTERCHANGEABLE CORE SUPPLIED AND INSTALLED BY THE G.C. ALL EXTERIOR LOCKS SHALL BE PROVIDED WITH CONSTRUCTION CORES. ALL PERMANENT CORES SHALL BE KEYED ALIKE. 5. PERMANENT CORES SHALL BE SHIPPED TO THE RESTAURANT GENERAL MANAGER. 6. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY. 7. LOCKNET SECURITY DOOR. COMPLETE DOOR, FRAME AND HARDWARE PACKAGE PROVIDED BY RSCS FACILITIES CONNECTIONS. 8. PROVIDE PUSH / PULL PLATES. IF REQUIRED BY LOCAL CODE, STOREFRONT DOOR PANIC HARDWARE SHALL BE DOR-O-MATIC 2092 RIM PANIC HARDWARE AND EXTERIOR PULLS WITH QUALITY #520 DOOR PULL. 9. MOUNT KICK PLATE ON PUSH SIDE ONLY. 10. MAXIMUM DOOR OPERATING PRESSURE: 5 LBS INTERIOR, 8.5 LBS EXTERIOR. 11. ADA COMPLIANT ACCESSIBILITY SIGNAGE, INCLUDE BRAILLE AS REQUIRED BY LOCAL JURISDICTION - (1) MEN, (1) WOMEN. 12. RESTROOM SIGN REQUIRED. 13. INSTALL WITH APPLIED DOORS STOPS AND WEATHER STRIPS. 14. FRAMES SHALL BE PAINTED. SEE INTERIOR AND EXTERIOR ELEVATION. 15. PROVIDE LATCH AND STRIKE PLATE HARDWARE BY DOOR MANUFACTURER TO BE COMPATIBLE WITH LOCK. 16. PROVIDE 2" REMOVABLE ASTRAGAL FROM INSIDE ONLY. 17. OPTIONAL HARDWARE AT RESTROOM DOOR (COORDINATE WITH OWNER): OCCUPANCY INDICATION DEADBOLT, FALCON D271 PUSH PLATE, ROCKWOOD 70F - 8" X 16" PULL PLATE, TRIMCO 1017-3B - 4" X 16" 18. G.C. TO TRIM DOOR SWEEP TO FIT DOOR. 19. EXISTING DOORS AND FRAME TO REMAIN. COORDINATE WITH OWNER EXTENT OF HARDWARE REPLACEMENT. REPLACE ALL EXISTING HARDWARE WITH NEW TO MATCH EXISTING - FIELD VERIFY. (IE: HINGES, CLOSERS, PUSH BAR, PULL, CYLINDER, WEATHERSTRIPPING, SWEEP, THRESHOLD, ETC.) COORDINATE KEYING OF LOCKS WITH TENANT. 20. DOOR HARDWARE SHALL BE US32D FINISH, (COLOR TO MATCH ANODIZED ALUM. STOREFRONT.) 21. PROVIDE SIGN STATING "THIS DOOR FOR EMERGENCY USE ONLY". 22. MOUNT DOOR CLOSER ON STORAGE SIDE. 23. "GAP" EXISTS. REPLACE EXISTING WEATHERSTRIPPING AND SWEEP. 24. REMOVE EXISTING PUSH BAR AT INTERIOR SIDE OF DOOR. INSTALL NEW TOUCHBAR EXIT DEVICE AS SCHEDULED. FIELD VERIFY AND MODIFY/REPLACE AS REQUIRED EXISTING CYLINDER LOCK TO OPERATE WITH NEW TOUCHBAR EXIT DEVICE. 1. DIMENSIONS ON THIS DRAWING ARE TO FRAME EDGE. REFER TO SHEETS A1.0 FOR ROUGH OPENING DIMENSIONS. 2. ENTIRE STOREFRONT SYSTEM SHALL BE ANODIZED ALUMINUM. (MATCH EXISTING) 3. SEE SCHEDULE FOR GLASS TYPES. 4. REFER TO FLOOR PLAN, ELEVATIONS AND WALL SECTIONS FOR ROUGH OPENING DIMENSIONS. 5. ALL STOREFRONT MATERIAL AND GLAZING SHALL BE SUPPLIED AND INSTALLED BY G.C., U.N.O. NATIONAL ACCOUNTS SUPPLIER INTERIOR DOORS, FRAMES & HARDWARE LOCKNET CONSTRUCTION@LOCKNET.COM 800 JOHN C. WATTS DR. NICHOLASVILLE, KY 40356 PHONE: 855-432-4613 FAX: 877-887 HAMILTON PARKER JIM CAMPBELL PHONE: 614-358-7806 EMAIL: JIMCAMPBELL@HAMILTONPARKER.COM GLAZING SCHEDULE NOTE: SHADING COEFFICIENT SPECIFICATION PER LOCAL CODE REQUIREMENTS. DAYTIME VISIBILITY INTO DINING ROOM SHALL BE MAINTAINED **** ALL STOREFRONT GLAZING SHALL BE LOW "E" SOLAR GLASS **** 1" INSULATED GLASS 1" INSULATED TEMPERED GLASS 1/4" TEMPERED GLASS SAFETY GLASS BY MANUFACTURER B A C D DOOR NUMBER DOOR SIZE TYPEDOORFRAME1 2 3 4 1 2 3 4 1 2 3 1 2 3 1 2 3 1 3 4 1 2 3 45 6 7 5 6 DOOR NOTES PUSHPULL2 BUTTS LOCKS CLOSERS KICK PLATE THRESHOLD DOOR STOP MISCELLANEOUS SEE DOOR TYPE ELEVATIONSONE PAIR OFFSET PIVOTS PER DOOR MANUFACTURER, TOP &BOTTOM1 1/2 PR. MCKINNEY #TA2731, 4 1/2" X 4 1/2"CONTINUOUS HINGE INCLUDED IN PACKAGEH.D. TYPE 304 S.S. BOBRICK SPRING LOADEDYALE B-PB5401LN (PASSAGE)YALE B-PB5407LNICFULL LENGTH LATCH PROTECTION INCLUDED IN PACKAGEPANIC HARDWARE INCLUDED IN PACKAGEFALCON C953-7 OR C987-7 AS REQUIREDFALCON "T" SERIES - PRIVACY SETFALCON 1790 TOUCHBAR EXIT DEVICE (RIM)DORMA 8616 X 689CLOSER INCLUDED IN PACKAGEDORMA 7414 ARP SNB 689STAINLESS STEEL 10" X .050 X 2" LESS THAN DOOR WIDTHKICK PLATE INCLUDED IN PACKAGETHRESHOLD INCLUDED IN PACKAGEFLOOR STOP - ROCKWOOD 441 CUHINGE STOP - ROCKWOOD 532 NPWALL STOP - ASA 0714 COAT HOOK WITH BUMPERPUSH PLATE ROCKWOOD 70F - 8" X 16"PULL PLATE TRIMCO 1017-3B - 4" X 16"XCLUDER PEST CONTROL DOOR SWEEP #162622SWEEP (VISTA 231 STANDARD) NGP 101VAUNDERCUT 3/4"PROVIDE A SIGN STATING "THIS DOOR TO REMAIN UNLOCKEDDURING BUSINESS HOURS"COAT HOOK - BOBRICKDOOR SIGNACCESSIBLE ALUMINUM THRESHOLD BY DOOR MANUF.(PROVIDE SQUARED EDGE @ INT. TO RECEIVE TILE FINISH)1 3'-0" X 7'-0" (E) (E) (E) X 4, 5, 19, 20 2 3'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20 DOOR TYPES3/8"=1'-0" 1 NOT USED2 4 3'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20 3 3'-0" X 7'-0" (E) (E) (E) X 4, 5, 19, 20 5 4'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20, 23 6 3'-0" X 7'-0" C WD HM X X X X X X 2, 3, 6, 9, 10, 11, 12, 14, 17 7 3'-0" X 7'-0" C WD HM X X X X X X 2, 3, 6, 9, 10, 11, 12, 14, 17 8 3'-0" X 7'-0" E WD HM X X X X X 2, 3, 6, 9, 10, 14 (DOOR OPTIONAL - COORDINATE W/ OWNER) 1 1 09.16.2021 REVISION #1 CITY COMMENTS:1 09/23/21