Loading...
HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A3.0 Roof Plan1 TYP. 1 TYP. OPEN TO BELOW 1 TYP. 1 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 2 TYP. 3 3 3 4 5 6 6 6 6 6 6 66 6 6 6 7 7 8 9 9 9 9 9 9 10 10 10 10 10 14 1010 10 10 10 11 11 12 13 ROOF PLAN A3.0 9853 N MICHIGAN RD. CARMEL, IN 46032 TB21-10 GGD 08.06.2021PERMIT / BID: ISSUES AND REVISIONS: CHECKED BY: DRAWN BY: PROJECT NO.: KDI ENDEAVOR - REMODEL 62 SEATS / 3,011 +/- S.F. TACO BELL, CARMEL, IN A R C H I T E C T S 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com Rebecca L. Olson, AIA #AR11500059 IAN AI ND REGISTER E D REBECCAL.O L SONSTATE OF ARCHITEC T NO. AR11500059 ROOF PLAN 1/4"=1'-0" 1 ROOF PLAN NOTES KEY NOTES NOT USED N 1 EXISTING ROOFING SYSTEM TO REMAIN. PROTECT FROM DAMAGE. PATCH AND REPAIR AS REQUIRED. EXISTING PARAPET CAP FLASHING TO REMAIN. PROTECT FROM DAMAGE. EXISTING R.T.U. TO REMAIN. PROTECT FROM DAMAGE. EXISTING EXHAUST HOOD EXHAUST SYSTEM. SEE MECHANICAL DRAWINGS. EXISTING RESTROOM EXHAUST FAN TO BE REMOVED. SEE MECHANICAL DRAWINGS FOR NEW. EXISTING ROOFTOP BRACING TO REMAIN. PROTECT FROM DAMAGE. EXISTING WALK-IN COOLER AND FREEZER CONDENSERS TO REMAIN. PROTECT FROM DAMAGE. EXISTING ROOFTOP EQUIPMENT TO REMAIN. PROTECT FROM DAMAGE. EXISTING SCUPPER AND DOWNSPOUT TO REMAIN. PROTECT FROM DAMAGE. EXISTING FABRIC AWNINGS TO BE REMOVED AND REPLACED WITH NEW. SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. EXISTING ICE MACHINE CONDENSERS TO BE REMOVED AND REPLACED WITH NEW. NEW FRUITISTA CONDENSER. EXISTING ROOF LADDER TO REMAIN. PROVIDE SECURITY DOOR AT BOTTOM OF LADDER (1/8" ALUMINUM SHEET METAL DOOR. WIDTH OF LADDER. WITH ALUMINUM PIANO HINGE. ALUMINUM LOCK LOOP AND HANDLE / LATCH HINGE WELDED TO DOOR AND CONTINUOUS BRACKET AT 36" A.F.F.) EXISTING FABRIC AWNING TO BE REMOVED IN ITS ENTIRETY. PATCH AND REPAIR EXISTING ADJACENT FINISHES AS REQUIRED. WATERPROOFING: 1. PAINT UNDERSIDE OF PARAPET CAP FLASHING WITH FACTORY BONDED PAINT GRIP OR PRIMER. 2. TOP NAILING AT PARAPET CAP FLASHING WILL NOT BE ACCEPTED. 3. PENETRATIONS IN ROOFING MEMBRANE AND FLASHING SHALL ONLY BE MADE AS INDICATED ON THE DRAWINGS OR SPECIFICATIONS. 4. SEE SPECIFICATIONS FOR SEALANT SPECIFICATIONS. 5. ALL SHEET METAL FLASHING SHALL BE 22 GA. MIN. MISCELLANEOUS: 1. ROOF PENETRATIONS CLOSER THAN 12" FROM ANOTHER WILL NOT BE ALLOWED. 2. EXHAUST FANS MIN. 10'-0" AWAY FROM ALL AIR INTAKE / SUPPLY. 3. LOCATE WALK-IN CONDENSERS ON ROOF ONLY IF REQUIRED BY CODE. 2 3 4 5 6 7 8 9 10 11 12 13 14 09/23/21