HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A3.0 Roof Plan1
TYP.
1
TYP.
OPEN TO
BELOW
1
TYP.
1
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
3
3
3
4
5
6
6
6
6
6
6
66
6
6
6
7 7
8
9
9
9
9
9
9
10
10
10
10 10 14
1010
10
10 10
11
11
12
13
ROOF
PLAN
A3.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
ROOF PLAN 1/4"=1'-0" 1
ROOF PLAN NOTES KEY NOTES
NOT USED
N
1 EXISTING ROOFING SYSTEM TO REMAIN. PROTECT FROM DAMAGE. PATCH
AND REPAIR AS REQUIRED.
EXISTING PARAPET CAP FLASHING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING R.T.U. TO REMAIN. PROTECT FROM DAMAGE.
EXISTING EXHAUST HOOD EXHAUST SYSTEM. SEE MECHANICAL
DRAWINGS.
EXISTING RESTROOM EXHAUST FAN TO BE REMOVED. SEE MECHANICAL
DRAWINGS FOR NEW.
EXISTING ROOFTOP BRACING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING WALK-IN COOLER AND FREEZER CONDENSERS TO REMAIN.
PROTECT FROM DAMAGE.
EXISTING ROOFTOP EQUIPMENT TO REMAIN. PROTECT FROM DAMAGE.
EXISTING SCUPPER AND DOWNSPOUT TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING FABRIC AWNINGS TO BE REMOVED AND REPLACED WITH NEW.
SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.
EXISTING ICE MACHINE CONDENSERS TO BE REMOVED AND REPLACED
WITH NEW.
NEW FRUITISTA CONDENSER.
EXISTING ROOF LADDER TO REMAIN. PROVIDE SECURITY DOOR AT
BOTTOM OF LADDER (1/8" ALUMINUM SHEET METAL DOOR. WIDTH OF
LADDER. WITH ALUMINUM PIANO HINGE. ALUMINUM LOCK LOOP AND
HANDLE / LATCH HINGE WELDED TO DOOR AND CONTINUOUS BRACKET
AT 36" A.F.F.)
EXISTING FABRIC AWNING TO BE REMOVED IN ITS ENTIRETY. PATCH AND
REPAIR EXISTING ADJACENT FINISHES AS REQUIRED.
WATERPROOFING:
1. PAINT UNDERSIDE OF PARAPET CAP FLASHING WITH FACTORY
BONDED PAINT GRIP OR PRIMER.
2. TOP NAILING AT PARAPET CAP FLASHING WILL NOT BE ACCEPTED.
3. PENETRATIONS IN ROOFING MEMBRANE AND FLASHING SHALL ONLY
BE MADE AS INDICATED ON THE DRAWINGS OR SPECIFICATIONS.
4. SEE SPECIFICATIONS FOR SEALANT SPECIFICATIONS.
5. ALL SHEET METAL FLASHING SHALL BE 22 GA. MIN.
MISCELLANEOUS:
1. ROOF PENETRATIONS CLOSER THAN 12" FROM ANOTHER WILL NOT BE
ALLOWED.
2. EXHAUST FANS MIN. 10'-0" AWAY FROM ALL AIR INTAKE / SUPPLY.
3. LOCATE WALK-IN CONDENSERS ON ROOF ONLY IF REQUIRED BY
CODE.
2
3
4
5
6
7
8
9
10
11
12
13
14
09/23/21