HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A4.0 Ext Elevations2 2 2 2 2
2
3
TYP.
4
TYP.
5
TYP.
6
TYP.
7
TYP.
8 8 8 88
9
EXTERIOR
ELEVATIONS
A4.0
SOUTH ELEVATION1/4"=1'-0" 1
NOT USED 2
QTY ITEM DESCRIPTION ELEC. QTY ITEM DESCRIPTION ELEC.
NOTE: SIGNAGE UNDER SEPARATE PERMIT
V-04.42 1 42" SWINGING BELL PURPLE LOGO - FACE LIT
(13.53 S.F.)X
V-09.14W 1 14" WHITE CHANNEL LETTERS - WALL
MOUNTED (9.9 S.F.)X
V-XXX V-XXX
GENERAL NOTES CANOPY AND BUILDING ACCENT SCHEDULE SIGN SCHEDULE
EXTERIOR FINISH SCHEDULE EXTERIOR ELEVATION KEY NOTES
1 EXISTING SIGNAGE TO BE REMOVED AND REPLACED WITH NEW TACO BELL SIGNAGE AS
SCHEDULED. SEE SIGN SCHEDULE FOR ADDITIONAL INFORMATION.
EXISTING METAL FRAMED AWNINGS TO REMAIN. EXISTING FABRIC TO BE REMOVED AND
REPLACED WITH NEW PURPLE FABRIC (COLOR TO MATCH SW PURPLE TB2603C).
EXISTING CONCRETE BLOCK TO REMAIN. PROTECT FROM DAMAGE.
EXISTING BRICK VENEER TO REMAIN. PROTECT FROM DAMAGE.
EXISTING BUILT UP E.I.F.S. CORNICE TO REMAIN. PROTECT FROM DAMAGE.
EXISTING PARAPET CAP FLASHING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING CONCRETE ACCENT TO REMAIN. PROTECT FROM DAMAGE.
EXISTING ANODIZED ALUMINUM FRAMED GLAZING SYSTEM TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING ANODIZED ALUMINUM FRAMED ENTRY DOOR TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING DRIVE-THRU WINDOW TO REMAIN. PROTECT FROM DAMAGE.
REMOVE EXISTING DRIVE-THRU WINDOW. INFILL WALL. NEW CONSTRUCTION TO MATCH
EXISTING ADJACENT CONSTRUCTION.
EXISTING METAL FRAMED AWNING TO BE REMOVED. PATCH AND REPAIR ADJACENT
FINISHES TO REMAIN AS REQUIRED.
MISCELLANEOUS:
1. SEE SHEET A1.1 "WINDOW TYPES" FOR WINDOW ELEVATIONS.
SEALERS (REFER TO SPECIFICATIONS):
1. SEALANT AT ALL WALL AND ROOF PENETRATIONS.
2. SEALANT AT ALL WINDOW AND DOOR FRAMES AT HEAD AND JAMB. DO NOT SEAL
SILL AT WINDOWS.
3. APPLY NEOPRENE GASKET (CONTINUOUS) BETWEEN BUILDING AND CANOPY.
"CRITICAL" DIMENSIONS:
1. REQUIRED CLEAR OPENING WIDTH TO ENSURE COORDINATION WITH STANDARD
SIGNAGE / BUILDING ELEMENTS DIMENSIONS.
NOTE: NO EXTERIOR SIGNS ARE WITHIN THE SCOPE OF WORK COVERED BY THE
BUILDING PERMIT APPLICATION. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR COORDINATING THE INSTALLATION OF ALL EXTERIOR SIGNS AND INSTALLATION OF
REQUIRED BLOCKING AND ELECTRICAL CONNECTIONS FOR FINAL APPROVED SIGNS.
SYMBOL AREA MANUFACTURER COLOR CONTACT INFORMATION
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
EXTERIOR ARTWORK SCHEDULE
QTY. ITEMX
0 CAMO PATTERN- EXPRESSION PANEL (4'X8')G-510
0 G-511
0 G-512
CAMO PATTERN - EXPRESSION PANEL (4'X8')
CAMO PATTERN- EXPRESSION PANEL (4'X8')
1
HARDIE REVEAL PANEL JAMES HARDIE REVEAL PANEL SYSTEM - CYBERSPACE (SW7076), SEMI-GLOSS
SEE A7.2
2
AWNINGS SIGNAGE VENDOR BLACK BY SIGNAGE VENDOR
-
3
CORNER TOWER WESTERN STATE T-GROOVE 24 GA. PAINTED 18" PANEL - WEATHERED RUSTIC
-
4
5
6 -
7 -
8
9
10
11 -
0G-607 CAMO PATTERN - ART FILM (WINDOW)
SEE A7.2
SEE A7.2
SEE A7.2
SIDING JAMES HARDIE ARTISAN V-GROOVE 144"L X 8.25"W; 7" EXPOSURE COMES PRIMED FOR PAINT
- WORLDLY GRAY (SW7043), SEMI-GLOSS
DOWNSPOUTS - WORLDLY GRAY (SW7043), SEMI-GLOSS
HARDIE TRIM JAMES HARDIE HARDIE TRIM 5/4 SMOOTH 1" X 5.5" - CYBERSPACE (SW7076), SEMI-GLOSS
SCUPPERS - WORLDLY GRAY (SW7043), SEMI-GLOSS
HOLLOW METAL DOOR - SW PURPLE TB2603C, SEMI-GLOSS
NOT USED
RECESS OF SIDE ENTRY PORTAL WESTERN STATE T-GROOVE 24 GA. PAINTED 18" PANEL - WEATHERED RUSTIC
HARDIE REVEAL PANEL JAMES HARDIE REVEAL PANEL SYSTEM - SW PURPLE TB2603C, SEMI-GLOSS
0G-607 CAMO PATTERN - EXTERIOR MURAL (17'X8')
SEE A7.2
SEE A7.2
METAL PARAPET CAP - 24 GA. GALVANIZED - CYBERSPACE (SW7076) KYNAR 500 COATING
10
NEW PURPLE FABRIC TO BE INSTALLED ON EXISTING
METAL FRAMED AWNINGS (SIZE VARIES - VERIFY ON SITE
PRIOR TO ORDERING) COLOR TO MATCH SW PURPLE
TB2603C
EXISTING EXTERIOR WALL FINISHES, PARAPET CAP,
SCUPPERS, DOWNSPOUTS, WINDOWS, ENTRY DOORS,
ETC. TO REMAIN, UNLESS NOTED OTHERWISE.
2
3
4
5
6
7
8
9
10
11
12
2
09/23/21