Loading...
HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A6.0 Details-RoofNOTE: G.C. TO PROVIDE BLOCKING AND INSTALL THE LADDER ROOF DECK 6"4'-0"TYP.ASREQUIRED8" 15'-10"(FIELD VERIFY WITH FINAL INSTALLED ROOF STRUCTURE HEIGHT)1'-6"1'-0"TYP.1/8" MOLDED POLYURETHANE SAFETY CAPS 2 1/2" ALUMINUM CHANNEL SIDERAIL (6005-T5) 2 1/4" SERRATED ALUMINUM TREAD (6005-T5) 16' 17 7/8"7 1/4"PLAN BRACKET DETAIL 4 1/2 " 8 1 / 2 "3"1/4" 9/16"40" MINIMUMKITCHEN HOOD EXHAUST FAN HINGED BASE FOR SERVICING / CLEANING SEAL WITH APPROVED MATERIAL PRE-FABRICATED VENTILATED CURB EXTENSION NEMA 3R FUSED DISCONNECT, MOUNT TO HINGED BASE, SEE ELECTRICAL SHEET METAL COUNTER FLASHING - WRAPS TOP AND OUTSIDE OF CURB, EXTENDING OVER BASE FLASHING PRE-FABRICATED GALVANIZED STEEL CURB WITH INSULATION DUCT WRAP - SEE MECHANICAL MINIMUM 16 GAUGE WELDED DUCT NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB SCHEDULE ROOF DECK AND ROOF OPENING SUPPORT 4" SL O P E SLOP E 24 GAUGE G.I. COVER PLATE SET INTO SEALANT BEAD APPLIED ALONG BOTH SIDES OF JOINT - SECURE USING SCREW THRU STEEL / NEOPRENE WASHER CENTERED OVER 1/4" GAP BETWEEN ADJACENT SECTIONS OF NEW COPING. SCREW THRU NEOPRENE WASHER @ 30" O.C. @ INSIDE FACE ONLY SECURE OUTSIDE FACE OF METAL SECTIONS USING TWO NAILS THRU SLOTTED HOLES UNDER COVER PLATE 24 GAUGE G.I. CAP FLASHING COUNTER FLASH @ EXTERIOR FACE NOTE: JOINTS ARE TO OCCUR AT 10'-0" MAX.8" MIN.STANDARD CURB BASE, FASTEN PER MANUFACTURERS RECOMMENDATIONS ELECTRICAL CONDUIT GALVANIZED NAILS @ 6" O.C. SCREW THRU NEOPRENE WASHER, 3 PER SIDE PREFABRICATED CUSTOM CURB FLASHING (2) TAPERED 2X12 WOOD CURB OVER 2X SECURED TO DECK ROOFING MATERIAL 8" MIN.TYPICAL VENT PIPE S.S. BAND POSITIONED 1/4" FROM TOP OF STACK FLASHING DURO-LAST PRE-FABRICATED VENT STACK FLASHING DURO-LAST ROOFING MATERIAL OVER RIGID INSULATION 2X SOLID BLOCKING STACKED WITH DRILLED HOLE FOR PIPE PENETRATION SEALANT AT PENETRATION SCHEDULE ROOF DECK AND ROOF OPENING SUPPORT NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB SCHEDULE ROOF DECK AND ROOF OPENING SUPPORT FLASHING PAINT TO MATCH FINISH ROOFING PER ROOF PLAN (2) - 2X6 STUDS EACH SIDE OF BLOCKING LEDGER OR TRUSS SEE PLAN STRAP CONNECTION PER STRUCTURAL EXTERIOR FINISH 1/2" PLYWOOD SHEATHING 4"NOTES: 8" MINIMUMT.O. CURB TO T.O. ROOF1'-2"HVAC UNIT UNIT COUNTER FLASHING WITH NEOPRENE PERIMETER GASKET 1" HEAD NAILS AT 6" O.C. KNOCK-DOWN FLAT METAL CURB - SEE SCOPE OF WORK 5/8" PLYWOOD SECURED TO CURB CURB FLASHING TAPERED SLEEPER TO LEVEL CURB ROOFING MATERIAL OVER RIGID INSULATION NOTE: RTU SHALL BE LEVEL WITHIN 1/8" OVER LENGTH OF EQUIPMENTSCHEDULE ROOF DECK AND ROOF OPENING SUPPORT 60 MIL. TPO SINGLE PLY ROOF MEMBRANE BUILT-UP RIGID INSULATION CRICKET OVER ROOFING RIGID INSULATION OVER 2X FRAMING SLOPE PER ROOF PLAN PLYWOOD ROOF DIAPHRAGM PROVIDE A WOOD NAILER TO MATCH THE THICKNESS OF THE WALL FINISH. APPROXIMATELY 1" THICK IS TYPICAL BUT MAY VARY. TOP OF WOOD NAILER SHALL BE FLUSH WITH TOP OF WALL FINISH. THE WOOD NAILER SHALL EXTEND AT LEAST 1/2" INCH BEYOND THE LOWER HORIZONTAL EDGE OF THE PARAPET COPING TO ALLOW FOR PROPER FASTENING. FASTENERS USED TO ATTACH THE COPING TO WOOD NAILERS, MUST BE SPACED NO GREATER THAN 18" ON CENTER. ALLOW FOR 1/8" EXPANSION GAP BETWEEN 10'-0" LENGTHS OF COPING. PROVIDE COPING JOINT COVERS BETWEEN ENDS OF COPING PIECES AND AT CORNERS. JOINT COVERS SHOULD BE MADE FROM THE SAME MATERIAL AS THE COPING AND SHOULD LAP THE JOINTS A MINIMUM OF 6" ON EITHER SIDE. JOINT COVERS SHALL BE FASTENED THE SAME WAY AS THE COPING. FIBER CANT STRIP SLOPED 1/4":12" TOWARDS ROOF. ROOF MEMBRANE RUN UP AND OVER FIBER CANT TO LAP WOOD BLOCKING AT FRONT FACE. FACTORY PAINTED 24 GAUGE METAL COPING WITH 4" DROP FRONT, BACK AND ENDS (WHERE SHOWN). WALL FINISH AS SCHEDULED. DOUBLE 2X TOP PLATE. PLYWOOD SUBSTRATE. SEE SHEET A1.0 AND STRUCTURAL FOR ADDITIONAL DETAILS. 3 6 5 4 1 2 7 9 8 9 1 2 3 4 5 6 7 8 9 BUILDING PARAPET NOTE: SEE ALSO PLUMBING DRAWINGS HOT WATER INTAKE OR EXHAUST FLUE PIPE CLAMP-BOLT TO ANGLE, TYP. OF 2 2x2x1/8" ANGLE - LAG BOLT TO PARAPET @ BLKG. & CUT & BEND @ 90 DEG. ANGLE 14" MIN. MEMBRANE ROOF FLASHING BOOT ROOFING MEMBRANE RIGID INSUL. BD. FASTEN PVC TUBE TO TRUSS BELOW ROOF DECK WITH GALV. STEEL U-CLAMP WOOD TRUSS CHORD (TYP.) WOOD TRUSS WEB (TYP.) EXTEND PVC PIPE A MIN. OF 24" BELOW PLYWD. ROOF DECK ROOF PLYWOOD UTILITY LINES FOR ROOF TOP EQUIPMENT EXT. CLOSED CELL INSULATION FOAM TO SEAL PIPE 6" DIA. WHITE 40 SCHEDULE PV PIPE. 2-90 DEGREE PLUS VERTICAL THRU ROOF 8"MIN. MIN. 24 GA. G.I. CAP FLASHING SECURE W/ SCREW THRU STEEL/EPDM WASHER AS NEEDED FOR PROPER SECUREMENT (4 SIDES) 2x6 @ 16" O.C. 5/8" CDX PLYWOOD CAP SHEET OVER TOP OF SLEEPER EXTEND DOWN SIDES BY 2" (2) 2x12, RIP FOR LEVEL PLATFORM BASE FLASHING ROOFING MATERIAL NOTE: SET SUPPORTS ON SOLID NON-RIBBED NEOPRENE, AND SECURE LAG BOLTS THROUGH STEEL/NEOPRENE WASHER SCHEDULE ROOF DECK AND ROOF OPENING SUPPORT CONTACT LEE COBB WITH DURO-LAST AT 800-434-3876 FOR ROOF MEMBRANE QUESTIONS. 1/2" PLYWOOD SHEATHING MINIMUM 3/4" FURRING MINIMUM 1/16" EPDM HARDIE REVEAL PANEL VERTICAL SIDING BLUESKIN VP WATER RESISTIVE AIR BARRIER MEMBRANE FLASHING AND DRAINAGE PER FINISH REQUIREMENTS HEADER - SEE STRUCTURAL R.O. EXTERIOR INTERIOR SECTION A-A 30" 36"X 10 1/8"9 3/8"1 1/2"7 1/4" 3 1/4"3 1/2" 3 1/2" HATCH MATERIAL: GALVANIZED STEEL (PRIME PAINTED) COVER - 14 GA. GALV STEEL FRAME COVER - 14 GA. GALV STEEL FRAME CURB - 14 GA. GALV STEEL COVER LINER - 22 GA. GALV STEEL HATCH FINISH: GALV - PRIME PAINTED MANUFACTURER: PRECISION LADDERS, LLC OR EQUAL OUTSIDE PADLOCK PROVISION OUTSIDE HANDLE VINYL GRIP COVER REINFORCING CHANNEL (TYPICAL) 1" FIBERGLASS INSULATION EXTRUDED RUBBER GASKET HEAVY DUTY HINGE FRAME COVER W/ 3/8" PIVOT PIN COVER LINER ONE POINT LOCKING UNIT INSIDE PADLOCK PROVISION FRAME CURB PRESSURE INTENSIFIER HOLD OPEN ARM VINYL GRIP CLEAR OPENING CLEAR OPENINGA A4'-6" LENGTH OR LESS ONE POINT LATCH GREATER THAN 4'-6" TWO POINT LATCH CLEAR OPENING HOLD OPEN ARM ONE POINT LOCKING UNIT HEAVY DUTY HINGE PRESSURE INTENSIFIER NOTES: 1. ALL MOUNTING HARDWARE TO BE SUPPLIED BY OTHERS. 2. FOR OPERATING EFFICIENCY, HATCH HARDWARE VARIES BY SIZE EXAMPLE MODEL #: PH- A/G OPENING SIZE IN FEET-INCHES (PH-G2630) CONSTRUCTION A6.0 CON. @ STUD AND @ BLOCKING 3"=1'-0" 17 W.H. FLUE / INTAKE PIPE SUPPORT N.T.S. 13 PIPE HOOD N.T.S. 9 COPING JOINT DETAIL1 1/2"=1'-0"5 EXHAUST FAN CURB 1 1/2"=1'-0" 18 HVAC CURB 3"=1'-0" 14 PARAPET CAP DETAIL3"=1'-0"2 EXHAUST FAN CURB 1"=1'-0" 19 EQUIPMENT PLATFORM SUPPORT 3"=1'-0" 15 ROOF LADDER AND HATCH3"=1'-0"7 NOT USED 20 CRICKET 3"=1'-0" 16 SEALED PIPE FLASHING 1 1/2"=1'-0" 12 PARAPET CORNER 3"=1'-0" 8 ROOF LADDERN.T.S.4 DETAILS - ROOF 9853 N MICHIGAN RD. CARMEL, IN 46032 TB21-10 GGD 08.06.2021PERMIT / BID: ISSUES AND REVISIONS: CHECKED BY: DRAWN BY: PROJECT NO.: KDI ENDEAVOR - REMODEL 62 SEATS / 3,011 +/- S.F. TACO BELL, CARMEL, IN A R C H I T E C T S 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com Rebecca L. Olson, AIA #AR11500059 IAN AI ND REGISTER E D REBECCAL.O L SONSTATE OF ARCHITEC T NO. AR11500059 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED 09/23/21