2X WOOD STUDS
PLYWOOD SUBSTRATE FOR EXTERIOR WALLS
FLASHING TAPE AT ALL VERTICAL PARAPET TRANSITIONS. EXTEND TAPE 12"
OUTWARD AND UPWARD FROM CORNER AS SHOWN. LAP CORNERS WITH
ANGLED TAPE AS SHOWN TO INSURE FULL COVERAGE AT CORNERS
DOUBLE 2X TOP PLATE.
PAINTED 24 GAUGE PARAPET COPING. SLOPE 1/4:1 TOWARDS ROOF WITH
FIBER CANT STRIPS UNDER COPING. LAP FRONT AND BACK EDGE 2" DOWN
VERTICAL FACE. LAP EXPOSED COPING EDGE EXPOSED ENDS AT
VERTICAL PARAPET TRANSITION.
WRAP WALL FINISH ONTO VERTICAL FACE OF PARAPET TRANSITION
EXTERIOR FINISH ON OUTER SURFACE OF EXTERIOR WALL. THICKNESS
PER THE EXTERIOR ELEVATIONS ON SHEET A300 AND A301.
TERMINATION BAR AT VERTICAL TRANSITION OF WALL FINISH AND
MEMBRANE ROOFING. SEAL VERTICAL GAP BETWEEN TERMINATION BAR
AND FINISH PER ROOFING MANUFACTURER SPECIFICATIONS.
ROOFING MEMBRANE ON BACKSIDE OF PARAPET.
1 - PRE-WATERPROOFING
2 - FINISH-WATERPROOFING
1 TO
2
IMPORTANT: ONLY FASTEN PARAPET COPING ALONG THE FRONT AND BACK VERTICAL EDGE. NEVER ON TOP OF COPING.
1
3
4
2
5
6
5
4
7
8
9
1
2
3
4
5
6
7
8
9
BUILDING PAPER OVER PLYWOOD
BACK SIDE OF BOX
FRONT OF BOX
FLASHING TAPE AROUND BOX
8 x 8 x 4 STEEL HOSE BIB BOX.
HOSE BIB
SUBSTRATE
BACK SIDE OF PLYWOOD SHEATHING
HOSE BIB BOX
COLD WATER LINE TO HOSE BIB
2x6 WOOD WALL STUD
NOTE: HOSE BIB BOX SHALL BE ACUDOR-ARVB OR EQUAL
LOCKING DOOR
EXTERIOR FINISH
HARDIE REVEAL PANEL SIDING
MIN. 1/16" EPDM
MIN. 3/4" FURRING
1/2" PLYWOOD SHEATHING
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
SA FLEXIBLE
COUNTERFLASHING
VENT STRIP
PRE-FINISHED FLASHING W/
DRIP EDGE RETURN 3" HORIZ.
AND 4" VERT. OVER WRB AT
WALL OPENING
SEALANT W/ BACKER ROD
SILICONE. ANODIZED
ALUMINUM WINDOW FRAME -
SEE WINDOW SCHEDULE.
ALIGN FRAME AS SHOWN.
FACE OF HARDIE PANEL
BEYOND
5/8" GYP. BD.
RETURN WRB 5"
OVER WALL
OPENING SIDES
HEADER - SEE
STRUCTURAL
STOREFRONT
BACK PLATE TO
SUPPORT SHIM
3/8" SHIM
LAG BOLT &
WASHER
EXTERIOR INTERIOR
R.O.
R.O.
7/8"
SILICONE
SEALANT OVER
LAG BOLT
LOG BOLT &
WASHER
3/8" PLASTIC
SHIM
SOLID SURFACE
SILL
FLASHING TAPE
OVER BLDG.
PAPER
5/8" GYPSUM
BOARD
NOTE: SEE DETAIL 16/6.1 FOR ADDITIONAL INFORMATION REGARDING
WATER PROOFING AT AND NEAR WINDOWS AND DOORS
ANODIZED ALUMINUM
WINDOW FRAME - SEE
WINDOW SCHEDULE. ALIGN
FRAME AS SHOWN.
ANODIZED ALUM. SILL
RECEPTOR. W/ WEEP HOLES
SEALANT W/ BACKER ROD
ANODIZED ALUM. FLASHING
HORIZONTAL EDGE TRIM
HARDIE REVEAL PANEL SIDING
SILL FLASHING
MIN. 1/16" EPDM
MIN. 3/4" FURRING
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
1/2" PLYWOOD SHEATHING
EXTERIOR INTERIOR
NOTE: SEE DETAIL 16/6.1 FOR ADDITIONAL INFORMATION REGARDING
WATER PROOFING AT AND NEAR WINDOWS AND DOORS
EXTERIOR
INTERIOR
SEALANT W/ BACKER ROD
ANODIZED ALUMINUM
FLASHING TO MATCH THE
DOOR FRAME COLOR
SEALANT FLASHING
HARDIE REVEAL PANEL SIDING
1/2" PLYWOOD SHEATHING
BLUESKIN VP WATER
RESISTIVE AIR BARRIER
MEMBRANE
MIN. 3/4" FURRING
MIN. 1/16" EPDM
5/8" GYPSUM BOARD
ANODIZED ALUMINUM
WINDOW FRAME - SEE
WINDOW SCHEDULE
HOLD 3/8" SPACE FOR
BACKER ROD
ANODIZED ALUMINUM
WINDOW FRAME - ALIGN
FRAME WITH FACE OF OPAQUE
PANEL FRAME
SEALANT W/ BACKER ROD
ANODIZED ALUM. FLASHING
SELF-ADHERED
SILL FLASHING
FACE OF HARDIE PANEL
BEYOND
EXISTING
GYPSUM BOARD
20 GA. S.S. WALL
GUARD - TOP OF
SILL JAMB TO
JAMB - ATTACH
W/ CONST.
ADHESIVE
EXTERIOR INTERIOR
BACKER AND
SEALANT ROD
SILL FLASHING
ANODIZED ALUM.
FLASHING TO MATCH THE
DOOR FRAME COLOR
OVER AIR SPACE
SHIM
20 GA. S.S. WALL GUARD -
TYP. @ SILL, JAMB &
HEAD. ATTACH W/ CONST.
ADHESIVE
EXTERIOR INTERIOR
PLYWOOD SHEATHING TO
MATCH EXISTING BLDG.
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
PAINTABLE METAL FLASHING
SEALANT & BACKER ROD
SERVICE DOOR - SEE DOOR
SCHEDULE - ALIGN FRAME
WITH FACE OF SHEATHING 4" @ HEAD2" @ JAMB3/8" SHIM, LAG
BOLT & WASHER
HEADER - SEE
STRUCTURAL
GYPSUM BOARD
SHTG. TO
MATCH EXIST.
CONDITIONS
2X FRAMING
EXTERIOR INTERIOR
1"MAX.NOTE: SEE FLOOR FINISH PLAN FOR FLOOR FINISHES
EXISTING SLAB / FOUNDATION
(SHOWN SHADED)
ADA COMPLIANT
ALUMINUM
THRESHOLD -
SET IN SEALANT
FINISH FLOOR
OVER CONCRETE
SLAB
SERVICE DOOR -
SEE DOOR
SCHEDULE AND
SCOPE OF WORK
EXTERIOR
INTERIOR
BACKER AND SEALANT ROD
SILL FLASHING
ANODIZED ALUM. FLASHING
TO MATCH THE DOOR FRAME
COLOR OVER AIR SPACE
EXISTING GYPSUM BOARD
1"MAX.EXTERIOR INTERIOR
PRE-MOLDED
EXPANSION
JOINT
ADA COMPLIANT
ALUMINUM
THRESHOLD -
SET IN SEALANT
CONCRETE SLAB
ANODIZED
ALUMINUM DOOR
- SEE DOOR
SCHEDULE
1/2" PLYWOOD
SHEATHING
MIN. 3/4" FURRING
MIN. 1/16" EPDM
HARDIE TRIM
2X FRAMING
5/8" GYPSUM BOARD
BACKER AND SEALANT ROD
SILL FLASHING
ANODIZED ALUM. FLASHING
TO MATCH THE DOOR FRAME
COLOR
BLUESKIN VP WATER
RESISTIVE AIR BARRIER
MEMBRANE
INSULATED GLASS
DOOR, SEE SCHEDULE
MIN. 3/4" FURRING
MIN. 1/16" EPDM
HARDIE BOARD
PAINTED METAL
FLASHING
HORIZONTAL EDGE
TRIM
EXTERIOR GRADE
PLYWOOD
BLUESKIN VP WATER
RESISTIVE AIR BARRIER
MEMBRANE
J-BOX MOUNT TO
SUPPORTING
STRUCTURE. PROVIDE
POSITIVE SEAL FROM
BOX TO WEATHER
BARRIER
CONDUIT / PIPE
AIR SEAL
2X STRUCTURE
BACKWRAP OPENINGS
2X FRAMING HEADER - SEE
STRUCTURAL
1/2" GYP. BD.5 1/2" IF 2X47 1/2" IF 2X62" 1/2"
DOUBLE STUDS AT JAMB AND HEAD
WITH ANCHOR STRAP
HM FRAME
WD. DOOR
SEALANT
5/8" GYPSUM
BOARD
PROVIDE GYP. BD. RETURN
TO FRAME
EXISTING MASONRY VENEEREXISTING EXTERIOR WALL (SHADED)SEALANT
EXISTING
MASONRY
VENEER
EXISTING EXTERIOR WALL (SHADED)
EXISTING
GYPSUM BOARD
PROVIDE GYP. BD.
RETURN TO FRAME
EXISTING EXTERIOR WALL (SHADED)EXISTING MASONRY VENEER
2" MIN. TO 4" MAX. E.I.F.S.
FINISH. SEE ALSO 1/A6.2
NEW OR EXIST.
STOOP PENDING
LOCATION
PLYWOOD SHEATHING
EXTERIOR FINISH MATERIAL
BLOCKING AS REQUIRED
PVC (SCH 40) BUSHING - FILL WITH
SEALANT
FASTENER AS REQUIRED
WASHER
NOTE:
INSTALL BUSHING AFTER E.I.F.S.
APPLICATION HAS HARDENED.
DRILL HOLE SLIGHTLY LARGER
THAN BUSHING THROUGH
INSULATION ONLY, STOP AT
PLYWOOD. CAULK OPENING PRIOR
TO INSERTING FASTENER TO SEAL
PENETRATION.
CONSTRUCTION
A6.1
PARAPET CAP & TRANSITION N.T.S. 13
JAMB SERVICE DOOR 3"=1'-0" 9 WINDOW SILL AT DRIVE-THRU3"=1'-0" 5
STOREFRONT DOOR SILL 3"=1'-0" 10 WINDOW JAMB AT DRIVE-THRU 3"=1'-0" 6 TYPICAL WINDOW SILL3"=1'-0"2
CONNECTION THRU EXIST. FINISH 1"=1'-0" 11
HOSE BIB BOX 3"=1'-0" 12 THRESHOLD @ SERVICE DOOR3"=1'-0" 8 NOT USED4
DETAILS -
DOORS / WINDOWS
HEAD / JAMB @ SERVICE DOOR 3"=1'-0" 7 TYPICAL WINDOW JAMB3"=1'-0"3
TYPICAL WINDOW HEAD3"=1'-0" 1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
DOOR JAMB 3"=1'-0" 16
CO2 FILL / J-BOX 3"=1'-0" 17
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
CASED OPENING DETAIL 3"=1'-0" 14
HEAD/JAMB @ H.M. DOOR 3"=1'-0" 15
STANDARD DETAIL. FIELD
VERIFY ACTUAL CONDITIONS
STANDARD DETAIL. FIELD
VERIFY ACTUAL CONDITIONS
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED