HomeMy WebLinkAbout3-Taco Bell - 08.06.2021 - A7.0 Finish Floor Plan2X4
2X42X4 2X4 2X4 2X62X62X62X42X42X4
B-2
T-2
B-2
T-2
B-2
T-2
B-2
T-2
B-2
T-2
B-2
T-2
1
1111
1
1
1
1212
12
12
12
12
8
A6.3 (TYP.)
8
A6.3 (TYP.)
7
A6.3 (TYP.)
VESTIBULE #1
FREEZERCOOLER WASHING
PREP
TB COOK
OFFICE
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
PASSAGE
B-2
T-2
1
12
W-3
W-3
2
2
2
2
2
2
2
3
3 3
6
T-2
4
4
4
4
4
4
5
7
A6.3 (TYP.)4'-0"5
B-2
T-2
1
12
6
2
2
8
8
9
EQ. EQ.7
10
FRP-1
10
FRP-1
10
FRP-1
10
FRP-1
10
FRP-1
10
FRP-1
FINISH
FLOOR
A7.0
PLAN
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
FINISH FLOOR PLAN1/4"=1'-0" 1
N
FLOOR FINISH NOTES KEY NOTES
1. DENOTES FINISH MATERIAL. REFER TO SHEET A7.2 FOR FINISHES.
2. TILE JOINT (U.N.O.)
- QUARRY FLOOR TILE: 1/4"
- PORCELAIN FLOOR TILE: 3/16"
- GLAZED WALL TILE: 1/8"
- BASE, TRIM AND ACCESSORIES: MATCH ADJOINING TILE UNITS
3. TILE INSTALLATIONS REQUIRE MANUFACTURER'S STANDARD MOLDED CORNERS AT BOTH INSIDE AND OUTSIDE
CORNERS.
4. ALL BASE TILE SHALL BE SANITARY COVE STYLE WITH 3/8" MIN. RADIUS UNLESS NOTED OTHERWISE.
5. SEE SCOPE OF WORK SHEETS FOR RESPONSIBILITIES.
6. PROVIDE CLEAR SILICONE CAULK WHERE F.R.P. STOPS AT TOP OF COVE BASE.
7. TILE CHIPPING AROUND CORE DRILL HOLES FOR SEATING FIXTURE WILL NOT BE ACCEPTED.
XX 1 6" COVE TILE BASE. SEE DETAIL.
EXISTING TILE FLOORING AND SANITARY COVE TILE BASE IN BACK OF HOUSE TO REMAIN. PROTECT FROM
DAMAGE. PATCH GROUT WHERE NEEDED. STEAM CLEAN AND DEGREASE FLOOR PRIOR TO EQUIPMENT MOVE IN.
EXISTING METAL PANEL FLOORING AND METAL BASE IN DRY STORAGE / COOLER / FREEZER TO REMAIN. PROTECT
FROM DAMAGE.
EXISTING FLOOR DRAINS TO REMAIN.
PROVIDE FLOOR DRAIN AS REQUIRED IN NEW RESTROOMS. FLOOR DRAIN TO BE FLUSH WITH FLOOR FINISH.
FLOAT FLOOR TILE FOR FLUSH TRANSITION.
START POINT FOR FLOOR TILE. (FULL TILE)
ALIGN NEW FLOOR FINISH TRANSITION WITH WALL, AS SHOWN.
PROVIDE FLOOR DRAIN AS REQUIRED UNDER NEW SELF-SERVE SODA STATION TABLE. FLOOR DRAIN TO BE
FLUSH WITH FLOOR FINISH.
NEW F.R.P. WALL FINISH AT KITCHEN / B.O.H. AS REQUIRED.
SANITARY TILE BASE IN RESTROOM.
INSTALL FLOOR TILE IN A STRAIGHT STACK BOND.
2
3
4
5
6
7
8
9
10
11
12
09/23/21