PLUMBING SCHEDULE APLUMBING SCHEDULE A
PLUMBING LEGEND DGENERAL NOTES E
TW
FW
SD
CD
HWR
HW
CW
G
SS
GW
XXX
ITEM FIXTURE MANUFACTURER / MODEL NUMBERDESCRIPTION
F.C.O.FLOOR CLEANOUT OR CLEANOUT TO
GRADE
FW
H.B.
TW
S.O.C.
S.O.V.
P.T.R.V.
C.V.
C.W.
B.V.
E.C.O.
FU
BFP
EXTERIOR CLEAN OUT
COLD WATER BELOW GRADE
FILTERED WATER
PREMIXED TEMPERATURE WATER
SHUT-OFF GAS COCK
PRESS-TEMPERATURE RELIEF VALVE
SHUT-OFF GATE VALVE
BALL VALVE
CHECK VALVE
HOSE BIBB
BACK FLOW PREVENTER
FIXTURE UNIT
WALL CLEANOUTW.C.O.
R.D.
Y.B.
ABBREV. SYMBOLS DESCRIPTION
YARD BOX
ROOF DRAIN
V.T.R.
A.P.
V.B.F.
V.C.P.
A.C.P.
C.I.
U.T.R.
(E)
H.D.
F.D.
F.S.
OFD
A.F.F.
G.L.
(N) NEW
HUB DRAIN
GAS LINE
ABOVE FINISHED FLOOR
FLOOR SINK
OVERFLOW DRAIN
CAST IRON
VITRIFIED CLAY PIPE
UP THRU ROOF
ASBESTOS CEMENT PIPE
EXISTING
FLOOR DRAIN
VENT THRU ROOF
ACCESS PANEL
VENT BELOW FLOOR
G
CW
HW
H.W.R.
V.
C.D.
S.D.
HOT WATER RETURN
CONDENSATE DRAIN
SANITARY VENT
STORM DRAIN
GAS / GAS STUB
HOT WATER / HW STUB
COLD WATER / CW STUB
PLUMBING EQUIPMENT DESIGNATION
KITCHEN EQUIPMENT NUMBER: REFER TO
SOIL OR WASTE (GREASE WASTE)/WASTE STUB
KITCHEN EQUIP. DRAWINGS FOR DESCRIPTION.
SOIL OR WASTE (SANITARY)/ WASTE STUB
X-X 0000
SOIL OR
WASTE VENT COLD
WATER
HOT
WATER
TEMP'D
WATER
WASTE
FU
WATER
FU
FCO 1
FLOOR
CLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED
HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE / MODEL: 6000Z
ZURN / MODEL: Z-1400
WCO 1
WALL
CLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS
PLUG, WITH STAINLESS STEEL ACCESS COVER.
JOSAM / MODEL: 58510
WADE / MODEL: 8560E
ZURN / MODEL: Z-1446-BP
S 3
3-COMP.*
SINK INDIRECT -- 1/2" 1/2" -- -- 3
SINK, FAUCET, 0.65 GPM NOZZLE, DRAIN, & GEN IV POWER SOAK STANDARD, GEN III IS AN
OPTION FOR FRANCHISES
--
--
--
S 4 PREP SINK INDIRECT -- 1/2" 1/2" -- -- 2
SINK, FAUCET, 0.65 GPM NOZZLE, & DRAIN --
--
--
MV 1
MIXING
VALVE -- -- 1/2" 1/2" -- -- --
THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER,
CHECK VALVES SIZE PER PIPE CONNECTIONS.
POWERS SERIES LF495
LAWLER SERIES 310
LEONARD SERIES 170
RO 1
REVERSE
OSMOSIS INDIRECT -- 1/2" -- -- -- --
REVERSE OSMOSIS FILTER SYSTEM
BY OWNER
SEE TO DETAIL 9/P6.0
WADE / SHOKSTOP
JOSAM / MODEL: 75000
ZURN / SHOKTROL
1. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.
2. ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED IN
PLACE.
3. VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISE THE SEWER SYSTEM AS
REQUIRED.
4. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODES. PROVIDE DEEP SEAL
TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS.
5. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL
CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY
INSTALLATION.
6. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE
NON-ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
7. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND
10 FEET FROM ANY OUTSIDE AIR INTAKE.
8. PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.
9. INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER
AND WASTE LINES TO BE CHROME PLATED.
10. PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OF
EQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODE AND
RESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OF
EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THE GAS
METER.
11. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS.
12. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH-IN SCHEDULE & FOR ADDITIONAL WORK TO
BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH-IN PLUMBING AND FINAL CONNECTIONS TO KITCHEN
EQUIPMENT SHALL BE MADE BY THE CONTRACTOR U.O.N.
13. REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS.
14. ALL GAS LINES SHALL BE SUPPORTED SEE SPECS.
15. ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE.
16. PROVIDE WATER HAMMER ARRESTOR FOR ALL HAND SINKS, URINAL WATER LINES AND QUICK CLOSING
EQUIPMENT.
17. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THE
DIAMETER OF THE INDIRECT DRAIN.
18. PRIOR TO COMMENCING WORK ON THIS PROJECT, VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL
EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE
THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY.
19. COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY
DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS.
20. FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION.
BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0" A.F.F.
21. PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TO UNITS AND ALL FINAL
CONNECTIONS REQUIRED FOR OPERATION.
22. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY
FROM WHAT IS SHOWN. THEREFORE, VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO
CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY
FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
23. ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N.
24. ALL WATER LINES SHALL BE FLUSHED PRIOR TO CONNECTING ANY FIXTURES OR EQUIPMENT.
25. PROVIDE ESCUTCHEON PLATES AND SILICONE SEALANT AT ALL UTILITY PENETRATIONS INTO WALLS, CEILINGS,
AND FLOORS. DO NOT USE CAULKS OR EXPANDING FOAMS FOR SEALANT.
26. CVPVC SCHEDULE 40 WASTE PIPE CAN BE SUBSTITUTED FOR BLACK IRON WASTE PIPE WHERE ALLOWED BY
LOCAL MUNICIPALITIES.
27. PEX PLASTIC TUBING AND FITTING CAN BE USED AS AN OPTION, ALL INSTALLATION SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND SHALL COMPLY WITH SECTION
605.10.1 AND SECTION 605.10.2.
WC 1
WATER
CLOSET 4" 2" 1/2" -- -- 4 2
AM. STD. "CADET" / MODEL: 2467.100
KOHLER "HIGHLINE" / MODEL: K-3519
CRANE "ECONMISER" / MODEL: 31888
WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE,
ELONGATED BOWL, ADA COMPLIANT, 1.1 GPF, WITH OPEN FRONT SEAT LESS COVER,
OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLUSHMATE OR EQUAL.
PROVIDE TANK COVER LOCKS. FLUSH LEVERS SHALL BE RIGHT HAND OR LEFT HAND AS
REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE
REQUIREMENTS
DRAIN COLD WATER HOT WATER
FIXTURE NO.
DRAIN
D.F.U.
COLD WATER HOT WATER
D.F.U.
F.U.
C.W.
TOTAL
C.W.
TOTAL
H.W.
F.U.
H.W.
TOTAL
3 - COMPARTMENT SINK * 1 -- -- 3 3 3 3
FLOOR SINK 5 4 20 -- -- -- --
TOTAL - - 67 -- 20.75 -- 14.25
MOP SINK 1 2 2 2.25 2.25 2.25 2.25
RETHERMALIZER* 1 - - -- -- 1.0 1.0
HUB DRAIN 1 3 3 -- -- -- --
FLOOR DRAIN 9 3 27 -- -- -- --
HOSE BIBB/WATER FILTRATION UNIT 2/1 -- -- 2.5:1/1 3.5 -- --
PREP SINK * 1 -- -- 2 2 2 2
HAND SINK 2 2 4 1.5 3 1.5 3
LAVATORY 2 1 2 1.5 3 1.5 3
WATER CLOSET 2 4 8 2 4 -- --
*FIXTURE HAS INDIRECT WASTE TO FLOOR SINK
USE 1-1/2" CW SERVICE
USE 4" SANITARY (MIN)43 DFU
20.75 FU = 20 GPM
USE 1-1/4" HW SERVICE14 .25 FU =17 GPM
DRAIN: GW
COLD WATER:
HOT WATER:
PROBABLE DEMANDS/
AND PIPE SIZING
REQUIREMENTS: USE 4" SANITARY (MIN)24 DFUDRAIN: SAN
GREEN
GREEN
GREEN
FD 1 FLOOR DRAIN
(3")
3" 2" -- -- -- 2 --
LIGHT DUTY ADJUSTABLE PVC WITH THREADED ADAPTOR AND 5" DIAMETER NICKEL BRONZE
RING AND FASTENED GRATE
ZURAM / MODEL: FD-2210
SIOUX CHIEF 842
OATEY 72000
FS 1 FLOOR SINK 4" 2" -- -- -- 6 --
LIGHT DUTY, ACID RESISTANCE, WHITE PVC FLOOR SINK W/ 12" SQURE WHIT PVC HALF GRATE
AND STAINLESS STEEL DEBRIS BUCKET WITH LIFTING HANDEL.
SIOUX CHIEF / MODEL: 861-4PNDW
FS 2 FLOOR SINK 4" 2" -- -- -- 6 --
PVC 12" SQUARE FLOOR SINK, 6" DEEP, WITH ALUMINUM DOME STRAINER
AND NICKEL BRONZE HINGED TOP.
SIOUX / MODEL: 861-4-PND
GI 1
GREASE
INTERCEPTOR 4" -- -- -- -- -- --
JENSEN PRECAST 1,000 GALOON GREASE INTERCEPTOR WITH SAMPLE BOX
FINAL SIZE TO BE DETERMINED BY LOCAL BUILDING AUTHORITY
--
--
--
L 1 LAVATORY 1-1/4" 1-1/2" -- -- 1/2" 2 1.5
WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT SEE 8/P6.0,
4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER.
BRAIDED WATER LINES. FAUCET: FURNISHED BY OWNER-INSTALLED BY G.C. ELECTRONIC
HANDWASHING FAUCET, SLOAN BATTERY FAUCET. ADA COMPLIANT, 0.5 GPM AERATOR.
A.S. COMRADE/ MODEL: 0124.131
CRANE "HARWICH" / MODEL: 1412V
SLOAN FAUCETS SF-2350
S.O.V. ANSUL SHUT-OFF GATE VALVE
U UNION (LINE SIZE)
P.O.C. POINT OF CONNECTION
*. IF GEN POWER SOAK SINK USED THEN ADD A MIXING VALVE TO SINK ABOVE SUSPENDED CEILING.
WATER CALCULATION'S B
WH 1
WATER
HEATERS -- -- 1" 1" -- -- --
GAS FIRED TANKLESS WATER HEATER, 96% THERMAL EFF., 199,000 BTUH INPUT EA, 5.6 GPM
@67 F . RISE REC. RATE, 3" PVC FLUE & AIR INTAKE, ASME RTD TEMP.
& PRESS. REL. VALVE, ELECTRONIC IGNITION SYSTEM AND ELETRONIC CONTROLS.
NAVIEN NPE-240A
ALL WORK SHALL COMPLY WITH
THE 2006 INTERNATIONAL
PLUMBING CODE.
GREASE INTERCEPTOR DETAIL
9853 N MICHIGAN RD.
CARMEL, IN 46032
FDA-IN-01-21
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
ENDEAVOR - REMODEL
62 SEATS +/- / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
MISSOURI
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
CERTIFICATE OF AUTHORITY NO. 201808201274213
08/06/2021
09.10.2021COMMENTS
09.22.2021COMMENTS
P1.0
PLUMBING
SCHEDULES
AND NOTES
JTJ
DN
09/23/21