HomeMy WebLinkAbout5-Taco Bell - 08.06.2021 - P3.0 Water-Gas PlanWATER & GAS PLAN 1/4"=1'-0" A WATER & GAS PLAN NOTES CGAS LOAD SUMMARY D WATER FIXTURE SUMMARY E KEY NOTES B A B C D E F 12 11 10 9 8 7 6 5 4 3 2 1 TABLE TO CALCULATE WATER FIXTURE UNITS PLUMING FIXTURE WATER FIXTURE UNITS NUMBER OF FIXTURES TOTAL WATER FIXTURE UNITS WATER CLOSET 4 2 8 LAVATORIES 2 2 4 HAND SINKS 2 2 4 MOP SINK 2 1 2 3-COMPARTMENT SINK 4 1 4 1-COMPARTMENT SINK 3 1 3 SODA SYSTEM 1 1 1 ICE MACHINE 1 2 2 TOTAL WATER FIXTURE UNITS 28.0 28 WFU (22GPM) WATER PIPE SIZE= 1-1/2" WATER DISTRIBUTION PIPING IS SHOWN ABOVE FINISH CEILING. UNDER SLAB DISTRIBUTION ALLOWED AT CONTRACTOR OPTION. COORDINATE ALL DETAILS. NO ROOF PENETRATIONS PERMITTED WITHIN THE ROOF "WATER VALLEYS", REFER TO ROOF PLAN FOR LOCATIONS. FLUSH ALL WATER SUPPLY LINES OF ALL DEBRIS AND IMPURITIES PRIOR TO CONNECTING TO WATER FILTERS. PROVIDE REDUCED PRESSURE BACKFLOW TO SERVE CARBONATOR , DRAIN RELIEF TO FLOOR SINK WITH AIR GAP. PROVIDE A VENTED DOUBLE CHECK VALVE W/ATMOSPHERIC PORT FOR THE WATER LINES SUPPLY LINES TO FOOD SERVICE EQUIPMENT (ASSE -1022.) EQUIPMENT VENDER TO FOLLOW MANUFACTURE'S REQUIREMENTS TO INSTALL DOUBLE CHECK VALVE ON EQUIPMENTS WHERE APPLICABLE. A. B. C. D. E. F. 1218 CFH = 1,218,000 BTUH RETHERMALIZER DOUBLE FRYER TOTAL DEMAND BASIS OF DESIGN GAS DEMAND SCHEDULE WH-1 RTU-2 RTU-1 110 CFH 110 CFH 398 CFH 350 CFH 250 CFH NOTE: COORDINATE GAS DEMAND REQUIREMENTS AND PIPE SIZING WITH SITE-SPECIFIC RTU DESIGN. PIPE SIZE BASED ON 135' OF PIPE AND 7" W.C. (2) PATIO HEATERS (25 CFH / EACH) NA & WH-2 1/2" S-546 S-285 S-547 S-544 3" SSOLENOID VALVE BELOW CEILING 1-1/4" 1" HW C-077 C-107 P-315 S-600 S-375 S-513 S-284 (E)MOP SINK N-043 (E) SINK (E) SINK S-286 S-600 S-550 B-XX1 S-600 S-540 3/4" EXISTING FIXTURE TO REMAIN. REPLACE EXISTING FIXTURE WITH NEW SPECIFIED. RECONNECT ALL EXISTING PLUMBING TO NEW FIXTURE. ROUTE TO CONNECT TO EXISTING SUPPLY PIPING IN SPACE. VERIFY EXACT SIZE AND LOCATIONS IN FIELD PRIOR TO WORK. NEW TANKLESS WATER HEATER. ROUTE NEW HOT AND COLD WATER CONNECTIONS TO EXISTING WATER HEATER AND ASSOCIATED SUPPLY PIPING IN SPACE. ROUTE NEW 1-1/4" GAS PIPING FROM NEW EQUIPMENT TO CONNECT TO EXISTING COOKLINE GAS PIPING IN AREA. VERIFY EXACT SIZE AND LOCATION IN FIELD PRIOR TO WORK. EMERGENCY GAS SHUT-OFF VALVE TO BE LOCATED ABOVE CEILING. ROUTE NEW 3/4" FILTERED WATER TO FIXTURES. 3/4 CW DOWN ALONG WALL TO WATER FILTER S-286. SEE DETAIL 1/P3.0. BUNDLED SYRUP LINES TO BEVERAGE DISPENSERS S-284 & S-285 AND FILTERED WATER LINES TO ICE MAKERS S-513 AND FROZEN BEVERAGE DISPENSER S-739. SEE DRAWINGS A2.0 AND P4.0. 5 7 6 4 3 2 1 8 14 15 3" PVC COMBUSTION AIR AND VENT FOR WATER HEATER. SEE M2.1. 1/2" HOT WATER DOWN IN WALL TO RETHERMALIZER. PROVIDE SHUT-OFF VALVE OUTSIDE OF WALL FOR CONNECTION TO RETHERMALIZER. 1/2" COLD WATER TO REVERSE OSMOSIS FILTER P-315 AND 1/2" FILTER WATER FROM REVERSE OSMOSIS FILTER. PROVIDE SHUT-OFF VALVE ON CW PIPE PRIOR TO CONNECTION TO FILTER. SEE DETAIL 9 / P4.0. 1/2" COLD WATER. CONNECT TO WATER FILTER FOR BUNN POD BREWER S-547. PROVIDE SHUT-OFF VALVE PRIOR TO CONNECTION TO THE WATER FILTER. RUN GAS PIPE 18" A.F.F. WITH DIRT LEGS FOR GAS HOSE KITS TO COOKING EQUIPMENT. HARD GAS LINE BEHIND COOKING EQUIPMENT SHALL NOT BE MORE THAN 6" MAX. FROM THE WALL SURFACE. GAS DIRT LEG W/ GAS COCK TO COOKING EQUIPMENT. PROVIDE FLEXIBLE GAS HOSE KIT FOR CONNECTION TO COOKING EQUIPMENT. SEE 5/P5.0 FOR SIZES. EXISTING GREASE RECOVERY SYSTEM AND ALL ASSOCIATED PLUMBING TO BE REMOVED. VERIFY EXACT LOCATION IN FIELD PRIOR TO WORK. 12 11 10 9 13 1 1 1 2 3 3 4 5 6 73 3 8 8 8 8 S-739 9 10 3 11 12 13 14FILTERED WATER ISOMETRIC N.T.S. 1 S-513 S-513 * * F1 F2 F1 S-285 S-284 F2 * * F3 F3 F1 S-546 S-739* 15 S-286 3/4" COLD WATER FILTERED WATER SUPPLIED VIA SYRUP BUNDLE. REFER TO 11/P6.0. SEE SCOPE OF WORK FOR RESPONSIBILITIES.* FILTERED EQUIPMENT AND LINES: - WATER FILTER FILTERED LINE (COLD WATER) - ICE MAKER - ABOVE SELF-SERVE BEVERAGE DISPENSER * - ICE MAKER - ABOVE DRIVE-THRU BEVERAGE DISPENSER * - DRIVE-THRU BEVERAGE DISPENSER * - SELF-SERVE BEVERAGE DISPENSER * - ICED TEA BREWER - FROZEN BEVERAGE DISPENSER * S-286 S-284 S-285 S-513 S-513 S-546 S-739 S 4 S 3 WC 1 WC 1L 1L 1 RO 1 WH 1 3/4" 1/2"1/2" (E)WH 9853 N MICHIGAN RD. CARMEL, IN 46032 FDA-IN-01-21 08.06.2021PERMIT / BID: ISSUES AND REVISIONS: CHECKED BY: DRAWN BY: PROJECT NO.: ENDEAVOR - REMODEL 62 SEATS +/- / 3,011 +/- S.F. TACO BELL, CARMEL, IN A C H I T E C T S 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com Rebecca L. Olson, AIA #AR11500059 MISSOURI 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 CERTIFICATE OF AUTHORITY NO. 201808201274213 08/06/2021 P3.0 WATER AND GAS PLAN JTJ DN 09/23/21