HomeMy WebLinkAbout5-Taco Bell - 08.06.2021 - P4.0 Plumbing DetailsDRINK SYSTEM SCHEMATIC N.T.S. 11 DRINK SYSTEM SCHEMATIC DETAIL N.T.S. 16 TWYMF0021/2" TEMPERED WATER TO LAVATORIES SHUT-OFF VALVE (TYP) CHECK VALVE (TYP) DOMESTIC CW DOMESTIC HW THERMOMETER 1/2" LINE 1MV TEMPERING VALVE N.T.S. 17 REVERSE OSMOSIS SYSTEM N.T.S. 9 RTU CONDENSATE N.T.S. 13 WATER FILTRATION SCHEMATIC N.T.S. 6 YMF003WALL LAVATORY FLOOR MOUNT UPRIGHT SUPPORT 4x4 WELDED BASE PLATE W/ (4) 1/2" HILTI KWIK BOLT II OR EQUAL FINISH FLOOR WATER FILTER SYSTEM N.T.S. 4LAVATORY SUPPORT N.T.S. 8 TANKLESS WATER HEATERS N.T.S. 2 WATER LINE CO2 LINE TPS024FROZEN BEVERAGE DISPENSER 3/8" FILTERED WATER LINE 3/8" x 1/4" SHUT OFF VALVE 3/8" CO2 LINE FILTERED WATER LINE TO D/T DRINK DISPENSER CO2 LINE TO D/T DRINK DISPENSER TEE OFF FROM D/T DRINK DISPENSER CO2 LINE AND RUN TO FBD TEE OFF FROM D/T DRINK DISPENSER FILTERED WATER LINE AND RUN TO FBD FILTERED WATER AND CO2 LINES VIA SYRUP BUNDLE SEE 11/P6.0 FOR PLUMBING CONNECTIONS OF ADDITIONAL EQUIPMENT TO FILTER SYSTEM. IF TUBES ARE EXPOSED, PROVIDE STAINLESS STEEL WALL COVER 1. 2. 3. 4. 5. 6. 7. GENERAL NOTES: OVERALL DIMENSIONS 21" WIDE x 12" DEEP x 48 1/2" HIGH SEE SCOPE OF WORK FOR ADDITIONAL INFORMATION. INSTALLATION MUST COMPLY WITH STATE OR LOCAL PLUMBING CODES. THE UNIT MUST BE PROTECTED AGAINST FREEZING. USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. SEE SHT. A2.0 FOR LOCATION. WB2-M3-22-003 WATER BOOST MODULAR FILTRATION (WBMF) SYSTEM FILTER LINE F2 SUPPLIES BUNDLED TUBE BY PEPSI 1. ICE MACHINES FILTER LINE F1 SUPPLIES BUNDLED TUBE BY PEPSI 1. DRIVE THRU DRINK STATION 2. SELF SERVE DRINK STATION ALL WORK THIS DETAIL PER DETAILS 6, 11 & 12/P6.0 3/4" COLD WATER INLET TO 1/2" COPPER LINE AND FITTINGS AT FILTER. 3/4" OUTLET W/ INTEGRAL BACKFLOW PREVENTER, EQUAL TO WATTS REGULATOR CO. SERIES 007 AND SERVICE BALL VALVE. 2 1 2 KEY NOTES: 1 F2 F1 TPW001WASTE WATER INDIRECT TO FLOOR SINK/HUB DRAIN TEST PORT PRESSURE GAUGE STORAGE TANK SHUT-OFF VALVE PRESSURE REGULATOR GATE VALVE WATER FROM WATER SOFTENER - PRIOR TO WATER HTR.FILTERFILTERYMR008WATER TO CHEESE MELTER LINE AFTER PRESSURE REGULATOR SHALL BE 3/8" PLASTIC LINE CONNECTING AT THE TOP OF THE PRODUCTION LINE UTILITY CHASE. PREFILTER CARTRIDGE R.O. MEMBRANE SEE WASTE PLAN FOR CONDENSATE LINE BELOW ROOF REMOVABLE THREADED CAP FOR CLEAN-OUT & WINTER DRAINING CONNECTION TO DRAIN PAN FULL SIZE VENT TO ATMOSPHERE RETURN CONDENSATE DRAIN LINE THROUGH CURB OR THROUGH THE SINGLE MEMBRANE ROOF W/ MFR. APPROVED BOOT FLASHING. CONNECT TO MAIN ABOVE CEILING AND TERMINATE 2" ABOVE RIM OF MOP SINK. INSULATE ALL PIPING BEYOND THIS PENETRATION EQUIPMENT CURB 6" 4"3"CD RTU DRINK MACH. BUNDLE CONFIG. NTS 12 ICE MAKER CARB PUMP DRINKING Co2 SYRUP BUNDLEWATER & Co2 BUNDLE 9 FLAVORS & 4 LINES FOR FUTURE APPROX. 41 2" DIA. APPROX. 71 2" DIA TPS030TPS030DRIVE THRU DRINK COUNTER DINING ROOM FLOOR SINK DRINK DISPENSER ROOF CEILING BAG N BOX RACK 1/2 I.D. LINE WATER REGULATOR - 60PSI BULK CO2 TANK REMOTE ROOFTOP CONDENSER REMOTE ROOFTOP CONDENSER OVERALL FILTER DIMENSIONS: 21" WIDE x 12" DEEP x 48 1/2" HIGH SEE DETAIL SCOPE OF WORK FOR SCOPE DEFINITIONS. ROUGH-INS SHALL BE PROVIDED BY THE CONTRACTOR. INSTALLATION MUST COMPLY WITH ANY STATE OR LOCAL PLUMBING CODES. THE FILTER MUST BE PROTECTED AGAINST FREEZING. USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. SEE THE EQUIPMENT PLAN FOR LOCATION. SEE DETAIL 12 THIS SHEET FOR BUNDLE DETAILS "Y" FOR ICE MACHINES SUPPLY LINES SHALL BE INSTALLED @ FILTER OUTLET. BACKFLOW PREVENTERS FOR FILTER ASSEMBLY ARE PROVIDED. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. CO2 SECONDARY REGULATOR 90-100 PSI GENERAL NOTES: NOTE INSTALL ELECTRICAL, WATER, AND DRAIN IN ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL CODES. EQUIPMENT RATING: ED250 DISPENSER - 115V, 3.5 AMPS ED300 DISPENSER - 115V, 4.0 AMPS CARBONATOR - 115V, 60 Hz, 7.0 AMPS BOOSTER ASSEMBLY - 115V. 60 Hz, 6.5 AMPS SYRUP WATER FILTER THERE ARE TWO SELF-SERVE DRINK/ICE SYSTEMS WHICH SHARE A COMMON FLOOR SINK WITH THE D/T DRINK/ICE SYSTEM. SYRUP SYRUP SYRUP SYRUP SYRUP SYRUPSYRUP SYRUP SYRUP SYRUP SYRUP I EC CITY WATER SUPPLY 3/8" SHUT-OFF VALVE REFRIGERANT LINES REFRIGERANT LINES 3/8" Co2 LINE KEY NOTES: 1 BACK ROOM CARBONATOR MOTOR DRINK COUNTER ICE TEA BREWER ICE MACHINE FRUITISTA MACHINE 3/8" FILTERED WATER LINE TO DINING & DRIVE THRU A. WATER LINE TO ICE MACHINE B. WATERLINE TO WATER DISPENSER VALVE C. WATERLINE TO CARBONATOR 4 14 - 3/8" SYRUP LINE BUNDLE 2 1/2 X 3/8 X 3/8 "Y"3 3/8" SHUT OFF VALVES BARB FITTINGS. TYP @ ALL"Y"s 9 STAINLESS CHASE SURFACE MOUNTED FROM CEILING TO TOP OF ICE MACHINE 6 PRE-SET Co2 REGULATOR7 SURFACE MOUNTED S.S. CHASE; ONE FOR EACH BUNDLE. SEE DTL. 19/A6.4 8 BUNDLED TUBING CEILING PENETRATION. SEE DETAIL 18/A6.4 5 DRINK SYSTEM BUNDLED TUBING. SEE DETAIL 12/P6.0 10 DRINK DISPENSER ICE MACHINE OPENING IN WALL FOR DINING ROOM DRINK DRAIN LINE. SEE 11/A6.4 2 4 3/8" FILTERED WATERLINE - ICE TEA, FRUITISTA, DRINK MACHINES & ICE MACHINES 11 10 5 58 8 ICEMAKER DRAINDISPENSER DRAIN 11 4C 2 6 6 ELECTRICAL FOR DRINK SYSTEM. SEE SHEET E3.0 13 13 1 7 3/8" LINE FOR PRESSURIZE FILTERED WATER 12 12 7 12 CARBONATOR MOTOR 13 1 TYPICAL FOR 6 LINES BUNDLES OF 6 WATER LINES AND 1 Co2 LINE 3 9 3 9 1 1 4A 4B 4C 2 1 4A 4B 9 39 3 SYRUP LINE "T" SPLICES SHALL BE DONE BELOW THE D/T DRINK TABLE. ONCE SYRUP LINES HAVE BEEN SPLICE COMBINE 14 SYRUP LINES, 3 WATER LINES AND 1 Co2 LINE AND RUN TRHOUGH IN-WALL OPENING TO THE SELF SERVE DRINK STATION AND CONNECT LINES AS SHOWN. WATER HEATER SCHEDULE N.T.S. 7 QTY MODEL # 2 NPE-240A DESCRIPTION NAVIEN TANKLESS WATER HEATERS 1 MFK7 MANIFOLD KIT * 1 DET12 EXPANSION TANK 1 HAL ALARM LIGHT W/ INSTALLATION INSTRUCTIONS 1 PK100 STAND * THE FOLLOWING ARE INCLUDED IN THE MANIFOLD KIT: QTY DESCRIPTION QTY DESCRIPTION1 3/4" BLK GAS COCK 1 3" PVC 90° 1 3/4" BLK UNION 1 1/2" PVC STREET 90° 1 3/4" BLK TEE 1 1/2" PVC 90° ELBOW 1 3/4" BLK CAP 3 3/4" x 2 1/2" BLK NIPPLE 1 3/4" x 4 BLK NIPPLE 1 3/4" THD BALL VALVE 2 1 1/2" FX UNION 6 1 1/2" CXC 90 1 1 1/2" CXC TEE 2 1 1/2" BALL VALVES CXC 1 1 1/2" CHECK VALVES CXC 1 1 1/2" GALV ST 90 1 1 1/2" CX ST 901 HPT-507 1/2" P-TRAP 1 1/2" P4 SMA 1 1 1/2" x 1 1/2" x 1/2" TEE COPPER 1 DIAL THERMOMETER 1 1/2" COPPER FEMALE FITTING ADAPTER PREP LINES CHEESE MELTER R.O. SYSTEMDRY PRODUCTION LINE SUPPLY MAIN FROM METER C254 P452 N043 C107 B-223 Nxxx ICED TEA BREWER CARBONATOR 2 CARBONATOR 1 DRIVE-THRU DRINK SYSTEM SELF-SERVE DRINK SYSTEM VALVE MANIFOLD SELF-SERVE ICE MACHINE DRIVE-THRU ICE MACHINE S570 S570 S284 S285 S513 S513 SEE 11/P6.0 FOR PLUMBING CONNECTIONS OF ADDITIONAL EQUIPMENT TO FILTER SYSTEM. SURFLO DRINK/ ICE FILTRATION S286 S546 BUNN HOT WATER IN-LINE POLY FILTER FROZEN BEVERAGE DISPENSER S739 TPS031UTILITY - GENERAL KITCHEN (HOT) POWER SOAK @ 3 COMP. SINK FLOW ARROW POINT OF CONNECTION (PEPSI) POINT OF CONNECTION (GC) UTILITY - TOILET ROOMS / GENERAL KITCHEN (COLD) LEGEND RETHERMALIZER KITCHEN EQUIPMENT # (SHEET A2.0) SYSTEM WATER HEATER S547BUNN POD BREWER EXHAUST 6' 1'-2' INTAKE BALL VALVE UNION PIPE TO HUB DRAIN ROOF 2' MIN EXHAUST 6' 1'-2' INTAKE PRESSURE RELIEF VALVE EXIST. WATER HOT WATER SUPPLY LINE GAS SUPPLY LINE ROOF 2' MIN PRIMARY SUB 1 PROVIDE RAIN CAP HEATER NAVIEN WATER HEATER COLD WATER SUPPLY LINE AQUAREX WK1 WATER CONDTIONER OR EQUAL 110V-11W 9853 N MICHIGAN RD. CARMEL, IN 46032 FDA-IN-01-21 08.06.2021PERMIT / BID: ISSUES AND REVISIONS: CHECKED BY: DRAWN BY: PROJECT NO.: ENDEAVOR - REMODEL 62 SEATS +/- / 3,011 +/- S.F. TACO BELL, CARMEL, IN A C H I T E C T S 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com Rebecca L. Olson, AIA #AR11500059 MISSOURI 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 CERTIFICATE OF AUTHORITY NO. 201808201274213 08/06/2021 P4.0 PLUMBING DETAILS JTJ DN 09/23/21