HomeMy WebLinkAboutTaco Bell Carmel, IN - Permit-Bid - 08.06.2021X
X
AXXXX
X
X
X AXXX
X
AXXX
NAME
Taco Bell
ENDEAVOR REMODEL
9853 NORTH MICHIGAN ROAD
CARMEL, IN 46032
TITLE SHEET
T1.0
DEVELOPER / TENANT
NORTH MICHIGAN HOLDINGS, LLC
7162 READING ROAD, SUITE 730
CINCINNATI, OH 45237
CONTACT: MARK D. AYER / MIKE NEIMIEC
PHONE: 513.608.3619 / 773.793.0703
PREVIOUS BURGER KING OPERATED BUILDING TO BE REMODELED INTO TACO BELL RESTAURANT USE. SITE
WORK TO INCLUDE NEW DRIVE-THRU LANE EQUIPMENT. INTERIOR TO HAVE FULL REMODEL TO RESTAURANT
USE. EXTERIOR TO HAVE NEW SIGNAGE AND AWNING INSTALLED.
BUILDING AREA AND OCCUPANT LOAD:
TYPE AREA FACTOR OCCUPANTS
PUBLIC - DINING ROOM 932 N.S.F. 62 SEATS (1004.4) 62
PUBLIC - CUSTOMER AREA 118 N.S.F. 1:5 SF 24
KITCHEN - COMMERCIAL 565 G.S.F. 1:200 SF 3
STORAGE 475 G.S.F. 1:300 SF 2
OFFICE 40 G.S.F. 1:100 SF 1
PASSAGE 88 N.S.F. 0 0
VESTIBULE 117 N.S.F. 0 0
COOLER / FREEZER 224 G.S.F. 0 0
RESTROOMS 133 G.S.F. 0 0
MISC. 319 G.S.F. 0 0
TOTAL 3,011 G.S.F. 92
DESCRIPTION OF PROJECT:
LEGAL JURISDICTION: CITY OF CARMEL
BUILDING CODE: 2014 INDIANA BUILDING CODE (2012 IBC)
BUILDING AREA: 3,011 S.F. SEATING: 62
OCCUPANCY: A-2
TYPE CONSTRUCTION: V-B
2012 INDIANA PLUMBING CODE (2006 IPC)
2014 INDIANA MECHANICAL CODE (2012 IMC)
2009 INDIANA ELECTRICAL CODE (NFPA 70-2008)
2014 INDIANA FIRE CODE (2012 IFC)
2009 ICC A117.1 ACCESSIBILITY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1, 2007)
REFER TO CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS
FOR SPECIFIC SYMBOLS
ROOM NAME
SHEET NUMBER
ELEVATION NUMBER
CEILING HEIGHT
SECTION NUMBER
SECTION SHEET
DETAIL NUMBER
DETAIL SHEET
REVISION NUMBER
BLDG. HEIGHT
REFERENCE POINT
ELEV. LETTER
ELEV. SHEET
DOOR NUMBER
WINDOW NUMBER / DECOR ITEM NUMBER
EXTERIOR WALL FINISH NUMBER
KEY NOTE NUMBER
EQUIPMENT NUMBER
ROOM FINISH NUMBER
1. GENERAL CONTRACTOR (G.C.) TO PROVIDE AND PAY FOR ALL SPECIAL INSPECTIONS REQUIRED.
2. ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE INDIANA STATE BUILDING CODE,
INTERNATIONAL BUILDING CODE, AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF
THE CITY OF CARMEL, IN.
3. ALL ELEMENTS NECESSARY TO CREATE A LEGALLY OCCUPIABLE BUILDING SHALL BE PROVIDED.
4. G.C. TO PROVIDE AS-BUILT DOCUMENTS TO TENANT PRIOR TO PROJECT CLOSE OUT.
5. ALL MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS ARE RESPONSIBLE FOR ALL MECHANICAL,
ELECTRICAL, AND PLUMBING ITEMS PER CODE.
6. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. LATEST EDITION) ARE A PART OF
THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE.
7. DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE.
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION. SHOP DRAWINGS
SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO FABRICATION OF ANY ITEM. FAILURE TO
ADHERE TO THIS PROCEDURE SHALL PLACE FULL RESPONSIBILITY FOR ANY ERRORS DIRECTLY UPON THE
CONTRACTOR.
8. GENERAL CONTRACTOR AND ALL APPLICABLE SUBCONTRACTORS RESPONSIBLE FOR REMOVAL AND
DISPOSAL OF ANY EXISTING STRUCTURES, SITE CONDITIONS, ETC. FOUND ON SITE AND TO COORDINATE WITH
ALL LOCAL AUTHORITIES HAVING JURISDICTION FOR THE PROPER REMOVAL AND DISPOSAL OF EXISTING
STRUCTURES, SITE CONDITIONS, ETC. SEE ALSO CIVIL DRAWINGS FOR GEOTECHNICAL REPORT.
9. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY
DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO
STARTING WORK.
10. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY FLYNN RESTAURANT GROUP, IN WRITING, PRIOR TO
INSTALLATION.
11. G.C. IS RESPONSIBLE FOR SUBMITTAL, PAYING FEES AND OBTAINING ALL PERMITS ASSOCIATED WITH THE
PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, HOOD ANSUL, OR
OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT, ETC. G.C. REQUIRED TO PAY FOR TEMPORARY
FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER.
12. G.C. SHALL PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME
OF CONSTRUCTION.
13. IT IS THE G.C.'S RESPONSIBILITY TO CONFIRM THE AVAILABLE "RESIDUAL" WATER PRESSURE, PRIOR TO THE
START OF ANY WORK, AND NOTIFY THE TENANT IF THE AVAILABLE PRESSURE IS NOT ADEQUATE TO SERVICE
THE ANSUL SYSTEM OR OTHER PRESSURE SENSITIVE EQUIPMENT.
14. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AS REQUIRED TO SAFELY INSTALL NEW WORK. THIS
WORK SHALL BE THE FULL RESPONSIBILITY OF THE CONTRACTOR AND NO ACT, DIRECTIONS OR REVIEW OF
ANY SYSTEM OR METHOD BY THE ARCHITECT SHALL CHANGE OR AFFECT THE CONTRACTOR'S
RESPONSIBILITY IN THIS MATTER. SEE ALSO STRUCTURAL DRAWINGS.
15. G.C. SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS
OTHERWISE NOTED.
16. SCOPE OF WORK AND SPECIFICATIONS DOCUMENTS ARE INCLUDED AS CONTRACT DOCUMENTS FOR THIS
PROJECT. IF THEY HAVE NOT BEEN PROVIDED TO YOU FOR THIS PROJECT, PLEASE ASK TENANT FOR A COPY
OF APPLICABLE SECTION.
17. G.C. SHALL PROVIDE WARRANTY DOCUMENTATION FOR ANY/ALL NEW WORK PERFORMED AT THE
CONCLUSION OF THE PROJECT.
18. DRAWINGS ARE BASED ON EXISTING BUILDING SURVEY DOCUMENTS RECEIVED 4/20/2021 PREPARED BY IFTI
PROVISION SOLUTIONS. ARCHITECT NOT LIABLE FOR THE ACCURACY OF EXISTING BUILDING CONDITIONS.
FIRE SPRINKLER: NOT REQUIRED PER 903.2.1.2
NUMBER OF EXITS REQUIRED - DINING ROOM (1015.1): 2
NUMBER OF PUBLIC ACCESSIBLE ENTRANCES / EXITS (1007.1): 2
REQUIRED ASSEMBLY AISLE WIDTH (1028.9.1 (4) (EX.1)): 36"
REQUIRED AISLE ACCESS WAY (1028.10.1.1 - LESS THAN 12 FEET LENGTH): 12"
PLUMBING FIXTURE REQUIREMENTS PER TABLE 2902.1
TOTAL OCCUPANTS = 92 (46 WOMEN / 46 MEN)
CLASSIFICATION: ASSEMBLY (A-2)
REQUIRED PROVIDED
WOMEN MEN
0.61 0.61
0.23 0.23
1 1
WATER CLOSETS (1:75)
LAVATORIES (1:200)
SERVICE SINK
DRINKING FOUNTAIN NOT REQUIRED: TABLE 2902.1 (h)
ARCHITECT
FINN DANIELS ARCHITECTS
2145 FORD PARKWAY, SUITE 301
ST. PAUL, MN 55116
CONTACT: GREG DAHLING
PHONE: 651.888.6884 PERMIT / BID08.06.2021ISSUED FOR CITY PLANNING REVIEW
ISSUED FOR BID / PERMIT / CONSTRUCTION
ISSUED FOR PRELIMINARY REVIEW
ISSUED FOR CONSTRUCTION WITH REVISED INFO
ISSUED FOR BID
X'-X"
XX-X
DIRECTION OF DETAIL
X
AXXX
X
X
X
X
X-XXX
X'-XX"
ELEV.
PROJECT GENERAL NOTES VICINITY MAP
GENERAL DRAWING SYMBOLS
PROJECT DIRECTORY SHEET INDEX
PROJECT/CODE SUMMARY
T1.0 TITLE SHEET
GENERAL PROJECT INFORMATION
ARCHITECTURAL
A1.1 DOOR & WINDOW ELEVATIONS & SCHEDULES
A1.0 FLOOR PLAN
MECH. / ELEC. ENGINEER
CASE ENGINEERING, INC.
796 MERUS COURT
ST. LOUIS, MO 63026
CONTACT: NICK BASLER (MECH)
PHONE: 636.349.1600
N
A2.1 EQUIPMENT SCHEDULE
A4.0 EXTERIOR ELEVATIONS
A4.1 EXTERIOR ELEVATIONS
A6.0 CONSTRUCTION DETAILS - ROOF
A2.0 SEATING AND EQUIPMENT PLAN
A3.0 ROOF PLAN
A6.1 CONSTRUCTION DETAILS - DOORS / WINDOWS
A6.3 FINISH DETAILS
A6.4 CEILING DETAILS
A7.0 FINISH FLOOR PLAN
A7.1 REFLECTED CEILING PLAN
MECHANICAL / PLUMBING / ELECTRICAL
D1.0 DEMOLITION FLOOR PLAN
A8.0 INTERIOR ELEVATIONS - DINING ROOM
A8.1 ENLARGED PLANS AND ELEVATIONS
A7.2 FINISH SCHEDULE
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
WOMEN MEN
1 1
1 1
A8.2 INTERIOR ELEVATIONS - KITCHEN
A8.3 INTERIOR ELEVATIONS - KITCHEN
M1.0 MECHANICAL SCHEDULES AND NOTES
M2.1 MECHANICAL ROOF PLAN
M3.0 MECHANICAL DETAILS
P1.0 PLUMBING SCHEDULES AND NOTES
P2.0 WASTE AND VENT PLAN
P3.0 WATER AND GAS PLAN
P4.0 PLUMBING DETAILS
E2.0 RISER DIAGRAM AND LEGEND
E2.1 PANEL SCHEDULES AND LOAD SUMMARY
E2.2 ELECTRICAL SCHEDULES
E3.0 FLOOR POWER PLAN
E3.1 ENLARGED POWER PLAN AND DETAILS
E3.2 ROOF POWER PLAN
E4.0 LIGHTING PLAN AND SCHEDULE
E5.0 COMMUNICATIONS PLAN
E6.0 ELECTRICAL DETAILS
E6.1 ELECTRICAL DETAILS
E7.0 ELECTRICAL DETAILS
T2.0 LIFE SAFETY PLAN
SITE
A0.0 SITE PLAN
A0.1 SITE DETAILS
A0.2 SITE DETAILS
D1.1 DEMOLITION REFLECTED CEILING PLAN
M2.0 DUCT AND DIFFUSER PLAN
09/23/21
W/H
2X4
2X42X4 2X4 2X4 2X62X62X62X42X42X4
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
OFFICE
FIRE AND LIFE
SAFEY PLAN
T2.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
FIRE AND LIFE SAFETY PLAN1/4"=1'-0" 1
CODE LEGEND
KEY NOTES
1 G.C. TO PROVIDE AND INSTALL OCCUPANT LOAD SIGN ON WALL AT
9'-6" A.F.F. SIGN TO READ "MAXIMUM OCCUPANCY 92 PERSONS".
FINAL COORDINATE DETAILS AND LOCATION WITH LOCAL
AUTHORITY HAVING JURISDICTION PRIOR TO INSTALL.
PROPOSED LOCATION OF "K" CLASS FIRE EXTINGUISHER.
COORDINATE FINAL LOCATION WITH LOCAL AUTHORITY HAVING
JURISDICTION PRIOR TO INSTALL.
PROPOSED LOCATION OF "ABC" CLASS FIRE EXTINGUISHER.
COORDINATE FINAL LOCATION WITH LOCAL AUTHORITY HAVING
JURISDICTION PRIOR TO INSTALL.
2
3
NOT USED
N
EXIT
FE PROPOSED FIRE EXTINGUISHER
LOCATIONS (FINAL COORDINATE
QUANTITY AND LOCATIONS WITH LOCAL
AUTHORITY HAVING JURISDICTION
PRIOR TO INSTALL.)
EXIT ACCESS TRAVEL DISTANCE
(LENGTH AS NOTED ON PLAN)
3
FE
FE
FE
∂COMMON PATH OF
EGRESS TRAVEL = 4 FT.
∂EXIT ACCESS TRAVEL
DISTANCE = 60 FT. (DINING EXIT)
AND 57 FT. (SERVICE EXIT)
EXIT ACCESS TRAVEL
DISTANCE = 35 FT.
EXIT ACCESS TRAVEL
DISTANCE = 37 FT.
EXIT ACCESS TRAVEL
DISTANCE = 51 FT.
3
2
1
(2) OCCUPANT
(3) OCCUPANT
(1) OCCUPANT
(31) OCCUPANT
(56) OCCUPANT
09/23/21
W/H
1
1
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
DRY STORAGEDRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
1
12 2
2
2
3
7
TYP.
7
TYP.
7
TYP.
7
TYP.
7
TYP.
7
TYP.
7
TYP.
4
4
4
4
4
44
4
4
5
6 6
8 8
9
9
27
10
10
10
10
10
4
10
11
12
12 12
9
9
13 13
OFFICE
15
16
16
17
2
19
20 20
21
21
21
21
21 21 21
22
22
22
22
23
23
23
23
23 23 23 23
23
23
24 29
25
26
28
28
1 1
1
1
1 1
1
23
30
14
14
14
14
14
11
DEMOLITION
FLOOR
D1.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
DEMOLITION FLOOR PLAN 1/4"=1'-0" 1
N
TYPICAL EXISTING WALL TO REMAIN. PROTECT FROM DAMAGE. REFER TO BALANCE OF
DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING EQUIPMENT, FIXTURE, FURNITURE, ETC. TO REMAIN. PROTECT FROM DAMAGE.
REFER TO BALANCE OF DRAWINGS FOR ADDITIONAL INFO.
DEMOLITION ITEMS AS INDICATED (SEE KEY NOTES)
PLAN
GENERAL NOTES WALL LEGEND
1. DRAWINGS OF EXISTING CONDITIONS HAVE BEEN COMPILED FROM EXISTING DATA SUPPLIED BY THE OWNER TO
THE ARCHITECT. THE ARCHITECT MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED FOR THE ACCURACY OF
THE COMPLETENESS OF THE EXISTING INFORMATION RECORDED. THE CONTRACTOR SHALL FIELD VERIFY ALL
EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT
MIGHT ARISE IN THE COURSE OF THE DEMOLITION WORK.
2. THE OWNER RESERVES THE RIGHT TO SALVAGE ANY DEMOLISHED ITEM. VERIFY ITEMS TO BE SALVAGED WITH THE
OWNER PRIOR TO THE START OF DEMOLITION. REMOVE, PROTECT, CLEAN, REPAIR FOR REUSE AND TURN OVER
SUCH ITEMS AS DIRECTED BY THE OWNER.
3. DEMOLITION & REMOVAL OF SYSTEMS NOTED INCLUDES ALL WORK REQUIRED TO ACHIEVE SCOPE OF NEW WORK
AND DESIGN INTENT.
4. THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING CONDITIONS CAUSED BY CONTRACTOR OR
SUBCONTRACTORS, AND SHALL REPAIR ANY DAMAGES TO TENANT'S SATISFACTION. DURING CONSTRUCTION
CONTRACTOR TO PROTECT ADJACENT SURFACE FINISHES TO REMAIN AS REQUIRED.
5. WHERE WALLS, FINISHES, ETC. ARE REMOVED, REMAINING SURFACES ARE TO BE REPAIRED FOR NEW
CONSTRUCTION / FINISHES.
6. INSPECT INTERIOR AND EXTERIOR WALLS. REPLACE ANY DAMAGED SUBSTRATE WALLS, ETC. INSPECT DINING
ROOM WINDOWS & WALLS BELOW WINDOWS FOR EVIDENCE OF MOISTURE DAMAGE & IMPROPERLY INSTALLED
FLASHING. NOTIFY ARCHITECT AND TENANT IMMEDIATELY IF ANY DAMAGE IS FOUND.
7. SEE SITE PLAN FOR ANY SITE DEMOLITION WORK.
8. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL DEMOLITION WORK.
9. SEE MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS FOR MECHANICAL, ELECTRICAL, PLUMBING DEMOLITION
WORK.
KEY NOTES
1 REMOVE EXISTING WALL PARTITIONS, SHOWN DASHED.
REMOVE EXISTING DOOR AND FRAME.
MODIFY EXISTING OPENING AS REQUIRED FOR NEW DOOR
SCHEDULED.
ALL EXISTING KITCHEN EQUIPMENT / FIXTURES TO BE REMOVED
AND DISCARDED, U.N.O. (SOME FIXTURES SHOWN THESE PLANS
MAY ALREADY BE REMOVED - COORDINATE EXACT SCOPE ON SITE)
REMOVE EXISTING COUNTERTOP, UNDER COUNTER WALL, AND
ALL ASSOCIATED COMPONENTS.
EXISTING TOILET ROOM ACCESSORIES (SOAP DISPENSER, PAPER
TOWEL DISPENSER, ETC.) TO BE REMOVED.
EXISTING FIXTURES / MILLWORK / FURNITURE TO BE REMOVED.
EXISTING PLUMBING FIXTURES TO BE REMOVED.
EXISTING TILE FLOORING, TILE BASE, WAINSCOT AND CHAIR RAIL
AT FRONT OF HOUSE TO BE REMOVED.
EXISTING BACK OF HOUSE TILE FLOORING AND BASE TO REMAIN.
PROTECT FROM DAMAGE.
CAREFULLY REMOVE EXISTING TILE BASE THIS WALL AND RETAIN
FOR REUSE ON NEW BACK OF HOUSE WALL.
EXISTING METAL PANEL WALLS, CEILING AND FLOOR FINISHES TO
REMAIN AT DRY STORAGE, COOLER AND FREEZER. PROTECT FROM
DAMAGE.
EXISTING ELECTRICAL EQUIPMENT. SEE ELECTRICAL DRAWINGS
FOR SCOPE OF WORK.
REMOVE EXISTING F.R.P. WALL FINISH AT KITCHEN/B.O.H. AND
REPLACE WITH NEW AS SCHEDULED.
EXISTING OFFICE DESK COUNTER TO BE REMOVED. EXISTING
WALL SHELVING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING HAND SINK TO REMAIN. ASSOCIATED SOAP DISPENSER,
SANITIZER DISPENSER AND PAPER TOWEL DISPENSER TO BE
REMOVED AND REPLACED WITH NEW.
EXISTING RECESSED FLOOR MOP SINK TO REMAIN. PROTECT
FROM DAMAGE.
NOT USED.
EXISTING TANKLESS WATER HEATER TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING WALK-IN COOLER / FREEZER TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING SOLID SURFACE WINDOW SILL TO BE REMOVED. PREP
SILL FOR NEW SOLID SURFACE TOP AS SCHEDULED.
EXISTING ENTRY DOOR TO REMAIN. PROTECT FROM DAMAGE.
EXISTING ALUMINUM FRAMED WINDOW TO REMAIN. PROTECT
FROM DAMAGE.
EXISTING DRIVE-THRU WINDOW TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING EXTERIOR SIGNAGE ON TOWER ABOVE TO BE REMOVED
AND REPLACED WITH NEW. SEE EXTERIOR ELEVATIONS FOR
ADDITIONAL INFORMATION.
PORTION OF EXISTING BACK OF HOUSE FLOORING TO BE
REMOVED AS REQUIRED FOR NEW WALL CONSTRUCTION
SCHEDULED. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
PORTION OF EXISTING BACK OF HOUSE FLOORING TO BE
REMOVED AS REQUIRED FOR REMODELED SERVING AREA. SEE
SHEET A7.0 FOR EXTENTS.
EXISTING WALK-IN COOLER / FREEZER SEPARATION WALL AND
DOOR TO BE REMOVED AND RELOCATED. SEE SHEET A1.0 FOR
ADDITIONAL INFORMATION. PATCH/REPAIR COOLER FLOOR AS
REQUIRED.
REMOVE EXISTING DRIVE-THRU WINDOW. INFILL OPENING WITH
NEW CONSTRUCTION TO MATCH EXISTING ADJACENT
CONSTRUCTION.
EXTENT OF WALL REMOVAL TO ALIGN WITH EXISTING MENU SOFFIT
AS SHOWN.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
09/23/21
SS
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
DRY STORAGEDRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
OFFICE
1
1
2
2
2 TB COOK
2
3 4
5
5 5
6
7
8
9
9
9
9
9
10
10
10
10
10
10 11
11
11
11
11
12
1212
13
13
13
13
13
13
14
1414
14
15 15
16
16
16
16
16
16
1717
17
17
2018 18
18 18
18
18 18
18
18
18
24 23
21
DEMOLITION
REFLECTED
D1.1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
DEMOLITION FLOOR PLAN 1/4"=1'-0" 1
N
TYPICAL EXISTING WALL TO REMAIN. PROTECT FROM DAMAGE. REFER TO BALANCE OF
DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING EQUIPMENT, FIXTURE, FURNITURE, ETC. TO REMAIN. PROTECT FROM DAMAGE.
REFER TO BALANCE OF DRAWINGS FOR ADDITIONAL INFO.
DEMOLITION ITEMS AS INDICATED (SEE KEY NOTES)
CEILING PLAN
GENERAL NOTES WALL LEGEND
1. DRAWINGS OF EXISTING CONDITIONS HAVE BEEN COMPILED FROM EXISTING DATA SUPPLIED BY THE OWNER TO
THE ARCHITECT. THE ARCHITECT MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED FOR THE ACCURACY OF
THE COMPLETENESS OF THE EXISTING INFORMATION RECORDED. THE CONTRACTOR SHALL FIELD VERIFY ALL
EXISTING CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT
MIGHT ARISE IN THE COURSE OF THE DEMOLITION WORK.
2. THE OWNER RESERVES THE RIGHT TO SALVAGE ANY DEMOLISHED ITEM. VERIFY ITEMS TO BE SALVAGED WITH THE
OWNER PRIOR TO THE START OF DEMOLITION. REMOVE, PROTECT, CLEAN, REPAIR FOR REUSE AND TURN OVER
SUCH ITEMS AS DIRECTED BY THE OWNER.
3. DEMOLITION & REMOVAL OF SYSTEMS NOTED INCLUDES ALL WORK REQUIRED TO ACHIEVE SCOPE OF NEW WORK
AND DESIGN INTENT.
4. THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING CONDITIONS CAUSED BY CONTRACTOR OR
SUBCONTRACTORS, AND SHALL REPAIR ANY DAMAGES TO TENANT'S SATISFACTION. DURING CONSTRUCTION
CONTRACTOR TO PROTECT ADJACENT SURFACE FINISHES TO REMAIN AS REQUIRED.
5. WHERE WALLS, FINISHES, ETC. ARE REMOVED, REMAINING SURFACES ARE TO BE REPAIRED FOR NEW
CONSTRUCTION / FINISHES.
6. INSPECT INTERIOR AND EXTERIOR WALLS. REPLACE ANY DAMAGED SUBSTRATE WALLS, ETC. INSPECT DINING
ROOM WINDOWS & WALLS BELOW WINDOWS FOR EVIDENCE OF MOISTURE DAMAGE & IMPROPERLY INSTALLED
FLASHING. NOTIFY ARCHITECT AND TENANT IMMEDIATELY IF ANY DAMAGE IS FOUND.
7. SEE SITE PLAN FOR ANY SITE DEMOLITION WORK.
8. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL DEMOLITION WORK.
9. SEE MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS FOR MECHANICAL, ELECTRICAL, PLUMBING DEMOLITION
WORK.
KEY NOTES
1 EXISTING CEILING AT BACK OF HOUSE TO REMAIN, U.N.O.
PROTECT FROM DAMAGE. SEE REFLECTED CEILING PLAN FOR
ADDITIONAL INFORMATION.
AT AREA SHOWN HATCHED - EXISTING CEILING GRID TO REMAIN.
SEE REFLECTED CEILING PLAN FOR NEW WORK REQUIRED.
EXISTING CEILING TILES TO BE REMOVED AND REPLACED WITH
NEW AS SCHEDULED.
EXISTING SOFFIT TO BE REMOVED. PATCH ADJACENT FINISHES TO
REMAIN.
EXISTING SOFFIT TO REMAIN. PROTECT FROM DAMAGE.
EXISTING METAL PANEL CEILING IN DRY STORAGE / COOLER /
FREEZER TO REMAIN. PROTECT FROM DAMAGE.
EXISTING EXHAUST HOOD TO REMAIN. PROTECT FROM DAMAGE.
EXISTING CEILING GRID,TILES, LIGHT FIXTURES AND MECHANICAL
REGISTERS ABOVE SERVING AREA TO BE REMOVED. SEE
REFLECTED CEILING PLAN FOR NEW WORK REQUIRED THIS AREA.
PORTION OF EXISTING BACK OF HOUSE CEILING GRID AND TILES
TO BE REMOVED AS REQUIRED FOR NEW WALL CONSTRUCTION
SCHEDULED. SEE REFLECTED CEILING PLAN FOR ADDITIONAL
INFORMATION.
EXISTING FLOATING A.C.T. CEILING AND ASSOCIATED LIGHTING TO
BE REMOVED IN ITS ENTIRETY.
EXISTING LIGHTING IN BACK OF HOUSE TO BE REMOVED AND
REPLACED WITH NEW LED FIXTURES. SEE REFLECTED CEILING
PLAN FOR ADDITIONAL INFORMATION.
EXISTING EXIT LIGHT TO BE REMOVED AND REPLACED WITH NEW.
SEE REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION.
EXISTING LIGHT FIXTURES IN DRY STORAGE / COOLER / FREEZER
TO BE REMOVED AND REPLACED WITH NEW LED FIXTURES TO
MATCH EXISTING.
EXISTING BACK OF HOUSE MECHANICAL REGISTERS TO BE
REMOVED AND REPLACED WITH NEW.
EXISTING FRONT OF HOUSE MECHANICAL REGISTERS TO BE
REMOVED. EXISTING DUCTWORK TO BE REUSED. SEE A204 AND
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING RESTROOM CEILING, LIGHTING, MECHANICAL REGISTERS
AND SPEAKER TO BE REMOVED. SEE REFLECTED CEILING PLAN
FOR ADDITIONAL INFORMATION.
EXISTING PENDANT LIGHT TO BE REMOVED.
EXISTING LIGHT FIXTURES ATTACHED TO STRUCTURE TO BE
REMOVED. SEE REFLECTED CEILING PLAN FOR ADDITIONAL
INFORMATION.
EXISTING FABRIC AWNINGS TO BE REMOVED AND REPLACED WITH
NEW AS SCHEDULED. SEE EXTERIOR ELEVATIONS FOR ADDITIONAL
INFORMATION.
NOT USED.
EXISTING AWNING TO BE REMOVED IN ITS ENTIRETY. PATCH AND
REPAIR EXISTING ADJACENT FINISHES SCHEDULED TO REMAIN AS
REQUIRED.
AREA OF REMOVED/RELOCATED COOLER/FREEZER WALL AND
DOOR. PATCH/REPAIR COOLER CEILING AS REQUIRED.
NOT USED.
EXISTING FAN COIL TO BE RELOCATED AS REQUIRED FOR NEW
LOCATION OF COOLER/FREEZER WALL. EVALUATE AND MODIFY AS
REQUIRED FOR NEW FREEZER SIZE.
EXISTING FAN COIL LOCATION. EVALUATE AND MODIFY AS
REQUIRED FOR NEW COOLER SIZE.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
09/23/21
N69D03'23"E 274.51'35' INGRESS/EGRESS
EASEMENT
\A1;5' BUFFERYARD S69D03'23"W 276.55'\A1;5' BUFFERYARD
\A1;60' FRONT YARD SETBACK \A1;30' GREENBELT\A1;6' LANDSCAPE STRIP\A1;8' UTILITY EASEMENT\A1;10' BUFFERYARDS20D56'37"E 173.20'
N21D11'28"W 117.30'N18D19'42"W 55.96'40' UTILITY, DRAINAGE& INGRESS/EGRESS EASEMENTU.S. 421 (MICHIGAN ROAD)DTPTTC6" VERTICALPVC PIPED
DD
S DTELEPHONE TELEPHONE(4) POWER(4) POWER(1) TELEPHONE(1) CABLE(1) TELEPHONE(1) CABLE(5) POWER(5) POWER(4) POWERDSTR No. 1332 SAN MHN RIM ELEV 882.7910"Ø PVC PIPE N INV 870.5410"Ø PVC PIPE S INV 870.588"Ø PVC PIPE W INV 870.60UT UT
UTUTSANSANSAN SANSAN SANSAN SANSAN
SAN SAN
\A1;65.62' R/W\A1;61.49' R/W\A1;65.62' R/WRIGHT-OF-WAY
1
A0.1
4
A0.1
1
1
1
1
2
3
4
5 7
A0.16
80'-0"DRIVE-THRU WINDOW TOCENTERLINE OF SPEAKER BOX SITE
PLAN
A0.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
SITE PLAN 1"=20'-0" 1
KEY NOTES
1 PROPERTY LINE.
REMOVE EXISTING DRIVE-THRU MENU BOARD AND BRICK BASE.
REMOVE EXISTING CANOPY AND SPEAKER BOX.
REMOVE EXISTING HEIGHT BAR AND FOUNDATION AND REPLACE
WITH NEW. SEE DETAILS FOR ADDITIONAL INFORMATION.
EXISTING TRASH ENCLOSURE TO REMAIN. PROTECT FROM
DAMAGE. REPLACE EXISTING WOOD GATE FINISH WITH NEW
MAINTENANCE FREE DECKING FINISH. SEE DETAILS FOR
ADDITIONAL INFORMATION.
NEW DRIVE-THRU EQUIPMENT LOCATIONS. SEE DETAILS FOR
ADDITIONAL INFORMATION.
EXISTING SITE, LANDSCAPING,
LIGHTING, ETC. TO REMAIN,
UNLESS NOTED OTHERWISE.
NOT USED
2
3
4
5
N
6
09/23/21
9'-6"MATCHEXISTING2'-2" 1'-0"FACE OF CURB
CLEARANCE BAR, SEE
6/A0.1 FOR FOOTING
DETAIL. PLACE IN SAME
POSITION AS EXISTING
HEIGHT BAR SCHEDULED
TO BE REMOVED.
6" DIA. CONCRETE FILLED
30" HIGH BOLLARD. SEE
DETAIL 3/A0.1.
EXISTING CAP
FLASHING TO
REMAIN
EXISTING BRICK
VENEER TO REMAIN
EXISTING CONCRETE
BLOCK TO REMAIN
EXISTING GATE POST
TO REMAIN
EXISTING GATE POST
TO REMAIN
EXISTING GATE POST
TO REMAIN
EXISTING BRICK
VENEER TO REMAIN
EXISTING CONCRETE
BLOCK TO REMAIN
EXISTING GATE
FRAMING, SHOWN
DASHED, TO REMAIN.
GATE FINISH TO BE COMPOSITE PVC DECKING 1X6
SQ. EDGE W/ 1/8" MIN. GAP. (COLOR: LIGHT GRAY -
COORDINATE WITH FLYNN RESTAURANT GROUP
AND CITY REQUIREMENTS). SECURE WITH 2 COATED
DECK SCREWS AT EACH TOP, BOTTOM AND
MID-POINT FRAMING MEMBERS - COUNTERSINK.
SQ. CUT AT TOP AND BOTTOM - LENGTH OF NEW
PVC DECKING TO BE THE SAME AS THE EXISTING
FINISH SCHEDULED TO BE REMOVED.
EXISTING GATE
FRAMING, SHOWN
DASHED, TO REMAIN.
NOTES:
1. ALL AREAS OF THE MENU BOARD MUST BE VISIBLE
TO THE DRIVER LOCATED AT THE SPEAKER POST.
ASSUME DRIVERS LOCATION IS 24" FROM FACE OF
CURB, CENTERED ON THE SPEAKER POST.
2. CENTER OF MENU BOARD TO BE 5'-6" TO 9'-0" FROM
DRIVERS POINT OF VIEW.
3. PROVIDE (2) 1" CONDUITS FROM BUILDING TO
SPEAKER POST FOR LOW VOLTAGE WIRING.
DIGITAL MENU BOARD (60.7"
WIDE) WITH FRONT SWING
UP ACCESS. SEE 6/A0.1 AND
2/A0.2 FOR FOUNDATION
DETAILS.
6" DIA. CONCRETE FILLED 30"
HIGH BOLLARD. SEE DETAIL
3/A0.1.
SPEAKER POST WITH
DRIVE-THRU HEARING
IMPAIRED SIGNAGE, SEE
2/A0.1 FOR FOOTING DETAIL.
CANOPY, SEE DETAIL 2/A0.1
FOR FOOTING DETAIL
OUTLINE OF CANOPY ABOVE
FACE OF CURB
80'-0"TO CENTER OF DRIVE-THRU WINDOW℄3'-7" 2'-6"1'-0"
1'-4" 2'-10"
2'-8"℄℄ ℄ ℄
℄
7
7
°
ESTIMATED POSITION OF
DRIVERS HEAD ALIGNED
WITH CENTER OF
SPEAKER POST
SITE
DETAILS
A0.1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
N
ENLARGED MENU BOARD DETAIL 3/8"=1'-0" 1
SCOPE OF WORK FOR DIGITAL MENU BOARD INSTALL AND VENDORS
∂ RSCS TO SUPPLY DIGITAL MENU BOARD AND CABLE
∂ SIGN VENDOR TO SUPPLY ANCHOR BOLTS AND BOLT PATTERN TO G.C.
∂ SITE SURVEY - SIGN VENDOR.
REMODEL (SUCCESSOR MANDATORY - MIDTERM OPTIONAL FOR FZ)
1. EXISTING FOOTING (SKIP TO STEP 4) - SIGN VENDOR.
2. TRENCHING / CONDUIT - SIGN VENDOR
3. FORMING / FOUNDATION / ANCHOR-BOLTS (SKIP TO STEP 5) - SIGN VENDOR.
4. ANCHOR BOLTS - SIGN VENDOR.
5. DIGITAL MENU BOARD INSTALL - SIGN VENDOR
6. DIGITAL MENU BOARD CABLE PULL - SIGN VENDOR
7. DIGITAL MENU BOARD FINAL CONNECTION AND SYSTEM CHECK - SIGN
VENDOR.
REMODEL NEW BUILDING RETROFIT
FOUNDATION IS FURTHER
THAN 6'
USING EXISTING
FOUNDATION (ALTHOUGH
NOT RECOMMENDED
INTEGRATED CANOPY
EXISTS
BOLLARDS NEEDED - DO
NOT PLACE IN FRONT OF
MENU BOARD
RECOMMEND NEW FOUNDATION
WORK FOUNDATION PERFORMED
BY G.C.
-
-
WORK PERFORMED BY SIGNAGE
INSTALLER
N/A
N/A
N/A
WORK PERFORMED BY
SIGNAGE INSTALLER
RECOMMEND NEW
FOUNDATION WORK
PERFORMED BY G.C.
-
-
WORK PERFORMED BY
SIGNAGE INSTALLER
MENU BOARD SCOPE OF WORK
CANOPY AND SPEAKER FOOTINGN.T.S. 2
BOLLARD AT DRIVE-THRU 3/4"=1'-0" 3 CLEARANCE BAR PLACEMENT DETAIL3/8"=1'-0"4
CLEARANCE BAR FOOTING N.T.S. 5 MENU FOUNDATION N.T.S. 6 TRASH ENCLOSURE ELEVATION3/8"=1'-0"7
N
COORDINATE FOUNDATION / ANCHOR BOLT
REQUIREMENTS WITH DIGITAL MENU BOARD
SUPPLIER AS REQUIRED FOR INSTALLATION
ON SPECIAL FOUNDATION WITH BRICK
VENEER AND CONCRETE SILL BLOCK TOP.
SEE 2/A0.2.
09/23/21
DIGITAL MENU
BOARD - SEE 1/A0.2
FOR DETAILS
PRECAST CONCRETE
CAP TO MATCH
EXISTING CONDITION
REMOVED (BY G.C.)
BRICK VENEER TO
MATCH EXISTING
CONDITION
REMOVED ( BY G.C.)
GRADE
MENU BOARD
FOUNDATION
DESIGNED BY SIGN
VENDOR1'-4"PER SIGN
VENDOR
4"8"PER SIGNVENDOR\A1;VENDOR1'-4"5'-8"
(ADJUST AS NEEDED BASED ON FINAL
MENU BOARD WIDTH - 4"± PAST
OUTER EDGE OF MENU BOARD)
4"8"PER SIGNVENDORDIGITAL MENU
BOARD - SEE 1/A0.2
FOR DETAILS
PRECAST CONCRETE
CAP TO MATCH
EXISTING CONDITION
REMOVED (BY G.C.)
BRICK VENEER TO
MATCH EXISTING
CONDITION
REMOVED ( BY G.C.)
GRADE
MENU BOARD
FOUNDATION
DESIGNED BY SIGN
VENDOR
60.7" WIDE MENU BOARD
(FINAL VERIFY)
SITE
DETAILS
A0.2
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
MENU BOARD CUT SHEETS N.T.S. 1 MENU BOARD FOUNDATION DETAILN.T.S.2
09/23/21
W/H
2X4
2X42X4 2X4 2X4 2X62X62X62X42X42X4
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
2
A8.1
2
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
OFFICE
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S
SERVING
VESTIBULE #2
1
2
3
4
5
6 7
8
1
A4.1
1
A4.0
2
A4.1
3
A4.1ALIGN5
TYP.
5
TYP.
5
TYP.
5
TYP.
6
6
10
14
13
12
9 9
1
2 4 A8.0
1
2
1
3 A8.2
5
4
6
4 A8.2
7
9
10
12 A8.2
2
4
3
5 A8.3
13
118 A8.2
PASSAGE
1
A8.3
3
5 A8.0
6
7
10
A8.0
MEN'S
4
11ALIGNALIGNALIGN14
14
1
A8.1 8'-7 1/2"3'-6"
9'-6 1/2"13'-7" 3'-8 1/4" 6'-0 1/2"8A
A8.0
8B
A8.0
18
A6.3
7'-2"
7
7
15
3'-0"
FLOOR
PLAN
A1.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
WALL LEGEND FLOOR PLAN NOTES
KEY NOTES
1
FLOOR PLAN 1/4"=1'-0" 1
NOT USED.
EXISTING PIPE BOLLARD TO REMAIN.
NOT USED.
KEEP CLEAR FOR UTILITIES AND SYRUP LINES.
STAINLESS STEEL CORNER GUARD / WALL CAP (TM-2), TYP. ALL
CORNERS IN BACK OF HOUSE FROM REAR WALL TO THE KITCHEN
SIDE OF THE SERVICE COUNTER.
SYRUP LINE CHASE (ABOVE).
RELOCATED EXISTING WALK-IN COOLER / FREEZER SEPARATION
WALL AND DOOR. CONTRACTOR TO FIELD VERIFY EXISTING
LIGHTING, FAN COILS, CONDENSERS, ETC. AND MODIFY AS
REQUIRED FOR NEW WALL / DOOR LOCATION.
NOT USED.
EXISTING ELECTRICAL EQUIPMENT TO REMAIN. PROTECT FROM
DAMAGE.
DOOR OPTIONAL - COORDINATE WITH OWNER. PROVIDE CASED
OPENING IF NO DOOR CHOSEN PER 14/A6.1.
PROVIDE NEW ACOUSTIC BATT INSULATION AS NOTED IN THE
WALL LEGEND AT EXISTING WALLS IF NONE EXISTS.
NEW FRONT COUNTER ASSEMBLY BY FURNITURE / DECOR
VENDOR.
EXISTING OFFICE COUNTERTOP TO BE REMOVED AND REPLACED
WITH NEW. EXISTING WALL SHELVING TO REMAIN AS IS. PROTECT
FROM DAMAGE.
CORNER GUARD TILE SCHLUTER.
INFILL WINDOW OPENING WITH EXTERIOR WALL CONSTRUCTION
TO MATCH EXISTING ADJACENT CONDITIONS.
N
DIMENSIONS:
1. ALL DIMENSIONS ARE TO FACE OF SHEATHING U.N.O. FOR NEW WALLS. DIMENSIONS TO EXISTING WALLS ARE TO
FACE OF EXISTING SHEATHING.
2. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQUIRED. NET CLEARANCE FROM FACE OF WALL /
WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES WITH VENDOR PRIOR TO INTERIOR WALL FRAMING.
WINDOWS / DOORS:
1. SEE SHEET A1.1 FOR WINDOW TYPES AND DOOR SCHEDULE.
2. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING.
FINISH SUBSTRATES:
1. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN LIEU OF GYP. BD. AT ALL WALLS
EXCEPT SHEARWALL SURFACES, U.N.O.
2. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF
INTERNATIONAL" APPROVED SEALANTS.
3. ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE, U.N.O.
DECOR:
1. SEE A2.0 FOR SEATING PLAN AND DETAILS.
2. SEE A7.0 FOR FLOOR FINISHES.
3. SEE A8.0, A8.1, A8.2 AND A8.3 FOR WALL FINISHES.
4. SEE A7.1 FOR CEILING FINISHES.
GENERAL:
1. PROVIDE THREE FIRE EXTINGUISHERS - (2) 10 LB. BC AND (1) 10 LB. ABC - TO COMPLY WITH LOCAL FIRE CODE.
LOCATE PER DIRECTION OF FIRE MARSHALL OR LOCAL AUTHORIZING AGENT FOR ADDITIONAL INFORMATION SEE
SHEET A2.0.
2. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ON NON-BEARING INTERIOR
PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE.
2
3
4
5
6
7
8
9
10
11
12
13
14
WALL HEIGHTS:
ALL INTERIOR NON-BEARING WALLS GO TO BOTTOM OF TRUSS, U.N.O. REFER TO STRUCTURE.
WALL SUBSTRATES:
∂ DINING ROOM:
1/2" GYPSUM WALLBOARD FROM FLOOR SLAB TO 6" ABOVE CEILING HEIGHT U.N.O. SEE 6 & 8/A6.3 (NOTE: THE
CEMENT BOARD SPECIFICATION IS DESIGNED TO ALLOW THE G.C. FLEXIBILITY.)
∂KITCHEN WALLS:
1/2" CEMENT WALLBOARD FROM SLAB TO 12" A.F.F. AT 12" A.F.F., USE 1/2" CDX PLYWOOD WITH F.R.P. SURFACE
FINISH TO 6" ABOVE CEILING HEIGHT U.N.O. IF DOUBLE SIDE SHEAR WALL PLYWOOD IS SPECIFIED. THE
PLYWOOD SHALL BE CONTINUOUS FROM SILL PLATE TO TOP PLATE. SEE 4/A6.3.
∂RESTROOM WALLS:
5/8" CEMENT WALLBOARD FROM T.O. FULL HEIGHT OF TILE FINISH SCHEDULED WITH 5/8" HI-IMPACT BRAND XP
WALLBOARD, TYPE X CORE FROM T.O. CEMENT BOARD TO 6" ABOVE CEILING HEIGHT U.N.O. NO SUBSTITUTIONS
ALLOWED. FINISH AS SCHEDULED.
∂ALL OTHER FRAME WALL CONDITIONS:
1/2" CEMENT WALLBOARD FROM T.O. SLAB TO 12" A.F.F., WITH 1/2" GYPSUM WALLBOARD FROM T.O. CEMENT
BOARD TO 6" ABOVE CEILING HEIGHT U.N.O. FINISH AS SCHEDULED.
TYPICAL INTERIOR WALL: WOOD STUDS AT 16" O.C. AS INDICATED. (2X4, 2X6 OR 2X8 WOOD STUDS
AS INDICATED)
INTERIOR SOUND-RATED WALL: TYPICAL INTERIOR WALL WITH 3 1/2" OR 5 1/2", UNFACED
FIBERGLASS BATT INSULATION. (2X4 OR 2X6 WOOD STUDS AS INDICATED)
EXTERIOR WALL INFILL: INFILL WALL AS REQUIRED. NEW CONSTRUCTION TO MATCH EXISTING
ADJACENT WALL CONSTRUCTION. NEW TO BE FLUSH WITH EXISTING.
EXISTING WALL: EXISTING WALL PARTITION TO REMAIN. PROTECT FROM DAMAGE. PROVIDE NEW
WALL SUBSTRATE AS INDICATED.
EXISTING WALL - NEW INSULATION: EXISTING WALL PARTITION TO REMAIN. PROTECT FROM
DAMAGE. PROVIDE NEW 3 1/2" OR 5 1/2", UNFACED FIBERGLASS BATT INSULATION (2X4 OR 2X6
WOOD STUDS) AND WALL SUBSTRATE AS INDICATED.
15
09/23/21
FINISH FLOOR 3'-4"(34" MIN. TO48" MAX.)KICK PLATE ON
PUSH SIDE ONLY
SIGN WHERE
REQUIRED PER
2009 A117.1
COAT HOOK ON
INSIDE OF ROOM
C
15
A6.1
15
A6.1
3'-4"(34" MIN. TO48" MAX.)KICK PLATE ON
PUSH SIDE ONLY
DOOR AND FRAME
EPOXY PAINTED COLOR
BOTH SIDES
E
P-4
C 6"3'-0" 6" 6"
D
15
A6.1
15
A6.1
A B
NOT USED NOT USED NOT USED
DOOR & WINDOW
ELEVATIONS
A1.1
& SCHEDULES
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
DOOR SCHEDULE DOOR SCHEDULE NOTES NOTES
1. LAMINATE DOORS 6, 7, 8 & 9 AND PAINT FRAMES 6, 7, 8, 9 & 10. SEE INTERIOR
ELEVATION, SHEET A8.0, A8.1 & A8.2.
2. ALL HARDWARE SHALL BE US32D U.N.O.
3. ALL HOLLOW METAL FRAMES SHALL BE 16 GA. STEEL U.N.O.
4. ALL LOCKS SHALL BE FALCON 6 PIN INTERCHANGEABLE CORE SUPPLIED AND
INSTALLED BY THE G.C. ALL EXTERIOR LOCKS SHALL BE PROVIDED WITH
CONSTRUCTION CORES. ALL PERMANENT CORES SHALL BE KEYED ALIKE.
5. PERMANENT CORES SHALL BE SHIPPED TO THE RESTAURANT GENERAL MANAGER.
6. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY.
7. LOCKNET SECURITY DOOR. COMPLETE DOOR, FRAME AND HARDWARE PACKAGE
PROVIDED BY RSCS FACILITIES CONNECTIONS.
8. PROVIDE PUSH / PULL PLATES. IF REQUIRED BY LOCAL CODE, STOREFRONT DOOR
PANIC HARDWARE SHALL BE DOR-O-MATIC 2092 RIM PANIC HARDWARE AND EXTERIOR
PULLS WITH QUALITY #520 DOOR PULL.
9. MOUNT KICK PLATE ON PUSH SIDE ONLY.
10. MAXIMUM DOOR OPERATING PRESSURE: 5 LBS INTERIOR, 8.5 LBS EXTERIOR.
11. ADA COMPLIANT ACCESSIBILITY SIGNAGE, INCLUDE BRAILLE AS REQUIRED BY LOCAL
JURISDICTION - (1) MEN, (1) WOMEN.
12. RESTROOM SIGN REQUIRED.
13. INSTALL WITH APPLIED DOORS STOPS AND WEATHER STRIPS.
14. FRAMES SHALL BE PAINTED. SEE INTERIOR AND EXTERIOR ELEVATION.
15. PROVIDE LATCH AND STRIKE PLATE HARDWARE BY DOOR MANUFACTURER TO BE
COMPATIBLE WITH LOCK.
16. PROVIDE 2" REMOVABLE ASTRAGAL FROM INSIDE ONLY.
17. OPTIONAL HARDWARE AT RESTROOM DOOR (COORDINATE WITH OWNER):
OCCUPANCY INDICATION DEADBOLT, FALCON D271
PUSH PLATE, ROCKWOOD 70F - 8" X 16"
PULL PLATE, TRIMCO 1017-3B - 4" X 16"
18. G.C. TO TRIM DOOR SWEEP TO FIT DOOR.
19. EXISTING DOORS AND FRAME TO REMAIN. COORDINATE WITH OWNER EXTENT OF
HARDWARE REPLACEMENT. REPLACE ALL EXISTING HARDWARE WITH NEW TO MATCH
EXISTING - FIELD VERIFY. (IE: HINGES, CLOSERS, PUSH BAR, PULL, CYLINDER,
WEATHERSTRIPPING, SWEEP, THRESHOLD, ETC.) COORDINATE KEYING OF LOCKS WITH
TENANT.
20. DOOR HARDWARE SHALL BE US32D FINISH, (COLOR TO MATCH ANODIZED ALUM.
STOREFRONT.)
21. PROVIDE SIGN STATING "THIS DOOR FOR EMERGENCY USE ONLY".
22. MOUNT DOOR CLOSER ON STORAGE SIDE.
23. "GAP" EXISTS. REPLACE EXISTING WEATHERSTRIPPING AND SWEEP.
1. DIMENSIONS ON THIS DRAWING ARE TO FRAME EDGE. REFER TO SHEETS A1.0 FOR
ROUGH OPENING DIMENSIONS.
2. ENTIRE STOREFRONT SYSTEM SHALL BE ANODIZED ALUMINUM. (MATCH EXISTING)
3. SEE SCHEDULE FOR GLASS TYPES.
4. REFER TO FLOOR PLAN, ELEVATIONS AND WALL SECTIONS FOR ROUGH OPENING
DIMENSIONS.
5. ALL STOREFRONT MATERIAL AND GLAZING SHALL BE SUPPLIED AND INSTALLED BY
G.C., U.N.O.
NATIONAL ACCOUNTS SUPPLIER
INTERIOR DOORS, FRAMES &
HARDWARE
LOCKNET
CONSTRUCTION@LOCKNET.COM
800 JOHN C. WATTS DR.
NICHOLASVILLE, KY 40356
PHONE: 855-432-4613 FAX: 877-887
HAMILTON PARKER
JIM CAMPBELL
PHONE: 614-358-7806
EMAIL:
JIMCAMPBELL@HAMILTONPARKER.COM
GLAZING SCHEDULE
NOTE:
SHADING COEFFICIENT SPECIFICATION PER LOCAL CODE REQUIREMENTS. DAYTIME
VISIBILITY INTO DINING ROOM SHALL BE MAINTAINED
**** ALL STOREFRONT GLAZING SHALL BE LOW "E" SOLAR GLASS ****
1" INSULATED GLASS
1" INSULATED TEMPERED GLASS
1/4" TEMPERED GLASS
SAFETY GLASS BY MANUFACTURER
B
A
C
D
DOOR
NUMBER DOOR SIZE TYPEDOORFRAME1 2 3 4 1 2 3 4 1 2 3 1 2 3 1 2 3 1 3 4 1 2 3 45 6 7 5 6
DOOR NOTES
PUSHPULL2
BUTTS LOCKS CLOSERS KICK PLATE THRESHOLD DOOR STOP MISCELLANEOUS
SEE DOOR TYPE ELEVATIONSONE PAIR OFFSET PIVOTS PER DOOR MANUFACTURER, TOP &BOTTOM1 1/2 PR. MCKINNEY #TA2731, 4 1/2" X 4 1/2"CONTINUOUS HINGE INCLUDED IN PACKAGEH.D. TYPE 304 S.S. BOBRICK SPRING LOADEDYALE B-PB5401LN (PASSAGE)YALE B-PB5407LNICFULL LENGTH LATCH PROTECTION INCLUDED IN PACKAGEPANIC HARDWARE INCLUDED IN PACKAGEFALCON C953-7 OR C987-7 AS REQUIREDFALCON "T" SERIES - PRIVACY SETFALCON 1690 CONCEAL VERTICAL PANIC HARDWAREDORMA 8616 X 689CLOSER INCLUDED IN PACKAGEDORMA 7414 ARP SNB 689STAINLESS STEEL 10" X .050 X 2" LESS THAN DOOR WIDTHKICK PLATE INCLUDED IN PACKAGETHRESHOLD INCLUDED IN PACKAGEFLOOR STOP - ROCKWOOD 441 CUHINGE STOP - ROCKWOOD 532 NPWALL STOP - ASA 0714 COAT HOOK WITH BUMPERPUSH PLATE ROCKWOOD 70F - 8" X 16"PULL PLATE TRIMCO 1017-3B - 4" X 16"XCLUDER PEST CONTROL DOOR SWEEP #162622SWEEP (VISTA 231 STANDARD) NGP 101VAUNDERCUT 3/4"PROVIDE A SIGN STATING "THIS DOOR TO REMAIN UNLOCKEDDURING BUSINESS HOURS"COAT HOOK - BOBRICKDOOR SIGNACCESSIBLE ALUMINUM THRESHOLD BY DOOR MANUF.(PROVIDE SQUARED EDGE @ INT. TO RECEIVE TILE FINISH)1 3'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20
2 3'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20
DOOR TYPES3/8"=1'-0" 1
NOT USED2
4 3'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20
3 3'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20
5 4'-0" X 7'-0" (E) (E) (E) 4, 5, 19, 20, 23
6 3'-0" X 7'-0" C WD HM X X X X X X 2, 3, 6, 9, 10, 11, 12, 14, 17
7 3'-0" X 7'-0" C WD HM X X X X X X 2, 3, 6, 9, 10, 11, 12, 14, 17
8 3'-0" X 7'-0" E WD HM X X X X X 2, 3, 6, 9, 10, 14 (DOOR OPTIONAL
- COORDINATE W/ OWNER)
09/23/21
W/H
2X4 2X42X4 2X4 2X4 2X62X62X62X42X42X4
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
OFFICE
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
G-281
DINING
CUSTOMER
WOMEN'S
SERVING
1
A8.1
VESTIBULE #2
F-500
F-920
S-444
B-405
S-544
S-443
F-915
F-915
S-739
B-405
U-061
U-070
K-490
U-100
U-121
U-152
F-165
F-174
S-483
L-043
(x4)
U-063
S-027
S-026
C-077 C-107
K-383 R-031
K-522
K-522
K-523 K-523 K-523
P-673
K-XX3 K-XX1 K-XX2 K-XX2 K-XX2 K-XX1
K-XX1K-XX2 K-XX2 K-XX2
C-400
B-406
K-221
N-043
K-602
K-602
K-XX2 K-XX2
K-XX2 K-XX2
K-XX2
K-XX2
K-XX2
K-XX1K-XX1
K-XX1 K-XX1
S-580
B-381
B-XX1
S-600
S-550
S-540
S-286
B-599
P-547
B-405
U-209
U-238
B-405
U-209
U-238
S-600
6
7
U-250 S-024 U-208
U-238
S-489
C-254
U-250 C-197
S-065
U-250S-023 U-208
U-238
S-489
C-254
U-250
C-197
P-362C
S-274
S-739A
S-283
S-285
S-482
S-513
S-547
S-544
S-546
S-600
6
S-204
U-011
U-238
U-239
U-100
U-121
U-152
F-165
U-070
U-062
U-100
S-570
S-254
S-349
U-130
U-131
U-135
U-136
2
A8.1
1
2
3
4 5
G-258
G-280
G-282 G-258
G-280
G-281
L-150
PASSAGE
F-262
P-452
P-315 P-550
B-405
K-210
N-130
N-171
MEN'S
3
3
3
3
3
K-490
U-061
U-070
K-490
U-100
U-121
U-152
F-165
U-131
U-135
U-136 S-375
S-284
S-513
S-570
K-420
3'-0"
S-287
B-241
B-251
B-290
B-405
8
P-417
N-698
B-241
B-251
B-290
B-405
8
K-132
SEATING AND
EQUIPMENT
A2.0
PLAN
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
SEATING AND EQUIPMENT PLAN1/4"=1'-0" 1 KEY NOTES
QTY. NAME REMARKSX
2 OVERLAP BELLS SEE A600 FOR LOCATIONSG-280
2 OVERLAP BELLS SEE A600 FOR LOCATIONSG-281
2 ANSWER IS TACOS SEE A600 FOR LOCATIONSG-258
NOT USED
1 EXISTING ELECTRICAL PANELS TO REMAIN.
EXISTING EXHAUST HOOD ABOVE TO REMAIN.
MAINTAIN 36" MIN. CLEAR ACCESSIBLE AISLE EGRESS PATHS TO
EXIT DOORS, 32" AT DOORWAYS AND CASED OPENINGS. (42" AISLE
REQUIRED WHEN AISLE SERVES MORE THAN 50 SEATS)
ALERT LIGHT BOX FOR 3-COMP POWER SOAK.
EXISTING PULL STATION TO REMAIN.
COORDINATE LOCATION OF PVC SYRUP CHASE FROM ABOVE
CEILING DOWN TO COUNTER.
TANKLESS WATER HEATERS. SEE PLUMBING DRAWINGS. (1
EXISTING / 1 NEW)
EXISTING HAND SINK TO REMAIN CLEAN/REPAIR/REFURBISH TO
"LIKE NEW".
2
3
4
5
6
7
SHELVING QUANTITIES GENERAL NOTES ARTWORK SCHEDULE
DECOR:
1. REFER TO SC SHEETS FOR SCOPE OF WORK RESPONSIBILITY.
2. - SYMBOL DENOTES A HANDICAP ACCESSIBLE TABLE.
LINEAR FEETSTORAGE TYPE
DRY STORAGE
REFRIGERATED STORAGE
FROZEN STORAGE
TOTAL
75
24
18
117
N
FAMILY FRAME SIZE
B
B
B
F01 28X40
F01 28X40
F01 28X40
1 OVERLAP BELLS SEE A600 FOR LOCATIONSG-282 B F01 28X40
8
09/23/21
EQUIPMENT
SCHEDULE
A2.1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
EQUIPMENT SCHEDULE LEGEND
B CONTRACTOR BUILDING ELEMENT
NO. QTY.G.C. INST. ITEM DESCRIPTION MFR. AND MODEL NUMBER PLUMB ELEC GAS REMARKS
B-049 0 X ROOF LADDER PRECISION LADDER #PH-G2-6X3-0
B-050 0 X ROOF HATCH PRECISION LADDER #PH-G-2-6X3-0
B-140 0 X DT WINDOW
B-219 0 X WATER HEATER DUNNAGE RACK NEW AGE INDUSTRIAL CORP., INC #98147
B-223 0 X 98% HIGH EFFICIENCY 120 MBH, 60 GAL. GAS WATER HEATER A.O. SMITH BTH 120 60 CYCLONE HE X X
B-241 4 X SOAP DISPENSER (WALL MOUNT) KAY 3741
B-251 2 X SANITIZER DISPENSER (WALL MOUNT) KAY 3741
B-253 0 X PAPER TOWEL DISPENSER / TRASH 12 GAL. BOBRICK #B-3944
B-265 2 X MIRROR, 18" X 36" BOBRICK #B-165-1836
B-275 2 X TOILET PAPER DISPENSER BOBRICK #B-2890
B-290 2 X PAPER TOWEL DISPENSER BOBRICK #B-262
B-300 2 X GRAB BAR 1 1/2" DIA. X 36" S.S. FINISH BOBRICK #B6806X36
B-305 2 X GRAB BAR 1 1/2" DIA. X 42" S.S. FINISH BOBRICK #B6806X42
B-310 2 X GRAB BAR VERTICAL 1 1/2" DIA. X 18" S.S. FINISH BOBRICK #B6806X18
B-320 0 CHANGING STATION
B-381 1 X CO2 CARBON DIOSIDE SENSOR / WARNING LOGICO2 CO2 MK9 SENSOR X
B-400 3 X WASTE BASKET - 32 GALLON RUBBERMAID #2632 (GREY)
B-405 7 X WASTE BASKET
B-406 1 X WASTE BASKET RUBBERMAID 28 QT #2956 (BLACK)
B-410 1 X SANITARY NAPKIN RECEPTACLE RUBBERMAID #6140
B-599 1 X MOP SINK SHELVING SPG #WST806Y
C COOKING EQUIPMENT
C-077 1 X DUAL FRYER FRYMASTER #2FQG30U X X COMES WITH GAS HOSE KIT (OPTIONAL: PITCO #TB-SSHLV14-2/FD VS7)
C-107 1 X RETHERMALIZER PITCO #TB-SRTG14-2 X X X
C-197 2 X TOASTER, SPLIT LID PROLUXE SL 1266TB X POWERED BY PRODUCTION LINE - (OPTIONAL: STAR #PSC14DTB)
C-254 2 X CHEESE MELTER (SINLGE) A.J. ANTUNES #CM-100 X X POWERED BY PRODUCTION LINE
C-400 1 X RETHERMALIZER TIMER FAST #TBZAP12120V X
E EXHAUST HOODS/FIRE SUPP.
E-107 0 X KITCHEN HOOD STRATOVENT #TBG365OVBD6FT3IN X
E-108 0 X STROTEVENT 106 IN H X 111 IN L BACK SPLASH STROTEVENT MODEL #BACKSPLASH06X111FLA X
E-272 0 X TIMER OUTLET X
F OFFICE/EMPLOYEE/MUSIC/MISC.
F-014 1 X FILE CABINET (2 DRAWER HIGH) 18X36X72H HON #582LL
F-021 1 X CHAIR - OFFICE HON #4609AB10 IN OFFICE AREA, SEE SHEET A8.2
F-022 1 X LICENSE FRAME (BLACK) CREATIVE PALETTE TB30 X IN OFFICE AREA, SEE SHEET A8.2
F-026 1 X DESK LAMP TBD IN OFFICE AREA, SEE SHEET A8.2
F-030 1 X COAT HOOK ISS #HOOK246R2Y X IN OFFICE AREA, SEE SHEET A8.2
F-040 1 OFFICE COMPUTER POS PROVIDED X IN OFFICE AREA, SEE SHEET A8.2
F-050 1 CREDIT CARD SATELLITE ROUTER JUNCTION
F-060 1 MONITOR - OFFICE YUM
F-080 1 OFFICE PRINTER / COPIER / FAX / SCANNER POS PROVIDED X
F-090 1 UPS (UN-INTERUPTABLE POWER SUPPLY) POS PROVIDED X
F-102 1 X MONEY COUNTER TELLERMATE #TIXR3000 X IN OFFICE AREA, SEE SHEET A8.2
F-131 1 SPEAKERS MOOD MEDIA LOCAL LEASE X
F-165 3 X FRONT LOAD SAFE PERMA VAULT #PRO-10TM
F-174 1 SAFE WITH TOUCH SCREEN CONTROLS X
F-211 1 X CLOCK B&B SYSTEMS #02100100 IN OFFICE AREA, SEE SHEET A8.2
F-262 2 X 6 COUNT EMPLOYEE LOCKERS E76000235 LYON WORKPLACE 12" X 18" X 78" GREY X IN OFFICE AREA, SEE SHEET A8.2
F-270 1 X FIRST AID KIT PROSTAT FIRST AID LCC #2617 X IN OFFICE AREA, SEE SHEET A8.2
F-500 2 STACKABLE HIGH CHAIR
F-504 1 DVR & MONITOR
F-915 2 FLOOR MAT CREWSAFE, ENTRANCE I #41150012 RUBBERIZED - 3'-5', RIBBED, CHARCOAL, WSM #800503
F-920 1 RUBBER MAT CREWSAFE, WSM#800507
K WORKSTATIONS/SHELVING/CARTS
K-132 1 CART, CLOSING MADE SIMPLE SPG / ISS (ALTERNATE: METRO) #WST1434Y
K-210 1 PREP SINK WORKSTATION 50 TRACK SPG / ISS (ALTERNATE: METRO) #WST255E, WALL TRAX SYSTEM FOR 1-COMP SINK, 16X50X40 + ACC
K-221 1 X 3 COMP SINK WORKSTATION 96 TRACK SPG / ISS (ALTERNATE: METRO) #DS1F, WALL TRAX SYSTEM FOR 3 COMP SINK, (3) 18X24 GRIDS + ACC
K-383 1 FRY WORKSTATION 30D X 78H X 36 IN. SPG / ISS (ALTERNATE: METRO) #WST1724E, 36 IN. CRISPY FRYSTATION
K-420 1 SHELF, BEV PLATFORM 18X24 SPG / ISS (ALTERNATE: METRO) #WST34Y: F/CARBONATOR, &/OR RECIRC PUMP
K-490 3 SHELVING 18X24X24, 2-TIER SPG / ISS (ALTERNATE: METRO) #WST440Y
K-522 2 SHELVING 18X60X76, 5-TIER, SMALL PACKAGING SPG / ISS (ALTERNATE: METRO) #WST1548Y
K-523 3 SHELVING 18X60X76, 3-TIER, CUP & LID SPG / ISS (ALTERNATE: METRO) #WST1580Y
K-525 0 SHELVING 18X48X76, 5-TIER SPG / ISS (ALTERNATE: METRO) #WST1613Y
K-602 2 SHELVING 18X36X86, 5-TIER, DRY STORAGE SPG / ISS (ALTERNATE: METRO) #WST238Y
K-607 0 SHELVING 18X72X86, 5-TIER SPG / ISS (ALTERNATE: METRO)
K-657 0 X SHELVING 24X72X86, 5-TIER SPG / ISS (ALTERNATE: METRO) #SU247285Y: WALK-IN COOLER 24X72X86
K-698 0 SHELVING 18X24X74, 5-TIER SPG / ISS (ALTERNATE: METRO) #SU186075Y
K-699 0 SHELVING 18X60X74, 5-TIER SPG / ISS (ALTERNATE: METRO) #SU186075Y
L LIGHTING/SIGNAGE/MENU BOARD
L-043 4 X DIGITAL MENU BOARD STRATACACHE, LG 43" DISPLAY X
N-043 1 X 3-COMP POWER SOAK 102 UNIFIED #PS6750 X X
N-062 0 X STAINLESS STEEL WALL MOUNTED SINK WITH FAUCET AERO #HS-MOD X
N-071 0 X MOP SINK FAUCET T&S B-2465 X
N-130 1 X 1 COMP PREP SINK FAUCET T&S B-0831-WA X FRANCHISE OPTION N-134: T&S B-2465
N-141 2 X WALL MOUNTED LAVATORY AMERICAN STANDARDS BRAND X
N-146 2 X FAUCET (RESTROOMS) T&S FAUCET B-0831-WA X 2" TWIST TYPE FOR N-698
N-171 1 LEVER WASTE DRAIN X
N-208 0 X MOP SINK AERO #3MP-2121-6/1P X INCLUDES (2) 24X36 WALL PANELS
N-698 1 X 1 COMP PREP SINK 53W X 27D X 35 1/2H AERO #2F1211617LR X
N SINKS/DISHWASHERS
NO. QTY.G.C. INST. ITEM DESCRIPTION MFR. AND MODEL NUMBER PLUMB ELEC GAS REMARKS
P-315 1 X REVERSE OSMOSIS SYSTEM 3M #56123-06, FSTM-075 X INSTALL OVER FLOOR SINK
P-362C 1 X FLEX DUAL LINE SERTEK
P-417 1 X 8-CHANNEL TIMER FAST #KTRACK2S4TB X
P-452 2 X HOT WATER SYSTEM BUNN-MACHINE #43600.0014 X X
P-547 1 STORAGE BINS THE WASSERSTROM CO. #P434 3-COMPARTMENT BIN - 12 GAL. EA. - BLUE/YELLOW/WHITE
P-550 1 X KNIFE RACK EDLUND #KR-699
P-673 1 WORK TABLE
P FOOD PREPARATION
R REFRIGERATION
R-209 0 FRY STATION REACH-IN FREEZER (LEFT HINGED) DELFIELD #GBF1P-SH-IK-TB2 X OPTION: RIGHT HINGED VERSION - DELFIELD #GBF1P-SH-TB2
S SERVING/DRIVE-THRU
S-023 1 X WARMER, EVO CARTER HOFFMAN X MOUNT ON PRODUCTION LINE OVER SHELF
S-024 1 X WARMER, EVO CARTER HOFFMAN X MOUNT ON PRODUCTION LINE OVER SHELF
S-026 1 X HEAT CABINET - FULL HEIGHT - (1) RH CRESCOR #H137S27D1TB X W/ 8 SHELVES EACH
S-027 1 X HEAT CABINET - FULL HEIGHT - (1) LH CRESCOR #H137S27D1TB X W/ 8 RACKS
S-065 1 X DESSERT TOWER HATCO #GRBW-24D
S-204 1 X DRIVE-THRU TIMER SYSTEM HME #C11422TB X
S-254 1 CONDIMENT RACK PRONTO #CHPWO446
S-274 1 X DRIVE-THRU BEVERAGE WORKSTATION SPG WST1242TA OPTIONAL: METRO
S-283 1 X DRINK STAGER WITHOUT STRAW HOLDER WST788E
S-284 1 BEVERAGE DISPENSER - SELF-SERVE CORNELIUS 611057625 X X SEE SCOPE OF WORK (PEPSI)
S-285 1 BEVERAGE DISPNSER - DRIVE-THRU SERVEND X X SEE SCOPE OF WORK (PEPSI)
S-286 1 X WATER FILTER SYSTEM SHURFLO #WB6-M3-22-003 FRANCHISEES CAN US SELECTO #TB5/620-5
S-287 1 X ISS-TABLE, DT, TB, 24 IN X 36 IN PREASSEMBLED FBD #1273610021 X X
S-349 1 DRIVE-THRU PICK UP WORKSTATION 30S42 SPG OPTIONAL: METRO
S-375 1 X DRINK STATION CARTER-HOFFMAN X S/S, INSULATED DRAIN TROUGH, WEIGHT RATED
S-443 1 X LID DISPENSER CAL-MIL ADA TB103
S-444 1 X NAPKIN DISPENSER TOR XPRESSNAP #5555100
S-482 1 CUP DISPENSER A.J. ATUNES #DACS60 W/ ANGLED MOUNTING BRACKET OMNITEAM CDB-DTA
S-483 1 CUP DISPENSER A.J. ATUNES #DACS50 MOUNTED ON 2 IN. STAINLESS STEEL WHEELS
S-489 2 SCALE EDLUND 10#X.1OZ, ELECTRONIC, EDLUND #DS-10 CSTM; WSM #113464
S-513 2 ICE MAKER (PLACED ON TOP OF DRINK MACHINES) MANITOWOC, KMS-1401MLJ X X
S-540 1 PEPSI BOOSTER TANK X X SEE SCOPE OF WORK (PEPSI)
S-544 4 ICE TEA URN BUNN / TDO-N-3.5
S-546 1 X ICED TEA BREWER TETLEY TB3Q X X
S-547 1 POD COFFEE BREWER MY CAFE AP AUTOPOD #42300.0008 X
S-550 1 BAG-IN-BOX SYRUP RACK CORNELIUS / REMCOR BNP12B8P X FLO-3REG-2CRB (BY PEPSI)
S-570 2 CARBONATOR CORNELIUS / REMCOR X X SHELF MOUNTED BELOW EACH DRINK (BY PEPSI)
S-580 1 CO2 BULK TANK MVE #11805373
S-600 4 BUNDLED SYRUP LINES CORNELIUS / REMCOR TUBE BUNDLE X SEE SCOPE OF WORK (PEPSI)
S-739 1 X FROZEN BERAGE DISPENSER, REMOTE FBD #12-7362-00021 X X MUST ORDER REMOTE CONDENSER S-739A FREEZE TRANSFORMER
S-739A 1 X FREEZE TRANSFORMER X
S-740 1 X FROZEN BEVERAGE CONDENSER, REMOTE FBD #12-3003-0006 X X 40 IN X 17 IN X 21 IN 208 SINGLE PHASE 2 WIRE 15 AMP, 105LB
U SECURITY/COMM./FIRE PROT./POS
U-011 1 BASE STATION - DT COMM. SYSTEM HME #C40000-5-HS3-TB
U-052 1 X SECURITY SYSTEM ADT #3BCZTB X
U-061 2 CREDIT CARD READER X
U-062 1 DRIVE-THRU CREDIT CARD READER VERIFONE P400 X
U-063 2 ALARM SENSOR X
U-070 3 RECIEPT PRINTER EPSON X 2 FOR F/C AND 1 DT 5.71 IN X 7.68 IN X 5.83 IN
U-100 4 POS / ORDER ENTRY TERMINAL X 2 FOR F/C AND 1 DT
U-121 3 CASH DRAWER BRACKETS #SU186075Y 2 PER CASH DRAWER
U-135 2 KIOSK TABLET SSP X
U-136 2 VERIFONE (CREDIT CARD MACHINE) SSP X
U-152 3 CASH DRAWER IBM, NCR & PAR 2 FOR F/C AND DT
U-208 2 MONITOR SUPPORT ARM FACILITY SOLUTIONS KIT, TB, 39 L - CRADLE NOT INCLUDED
U-209 2 MONITOR SUPPORT ARM FACILITY SOLUTIONS KIT, TB, 24.25 L MONITOR SUPPORT ARM, CRADLE NOT INCLUDED
U-238 5 KITCHEN MONITOR IBM, NCR & PAR MONITOR ON STAND
U-239 1 MONITOR CEILING MOUNTED BRACKET IBM, NCR & PAR
U-250 4 BUMP BAR WITH MOUNTING PLATE IBM, NCR & PAR WITH MOUNTING PLATE
W WALK-IN COOLER/FREEZER
W-059 0 X WALK-IN ICS / NORLAKE #105181 X X
QUICKSERV #SC4030BR-SELF CLOSING, R/H
HANDLE, OPENS RIGHT
RUBBERIZED - BLACK 2X8, 1/4 NON SLIP CORRUGATED TOP & RUBBER
NO-SLIP BACK ENTRANCE
GEN IV POWERSOAK INCLUDES T&S FAUCET #B-2475-PS-OH (FRANCHISE
OPTION: GEN III)
WHITE VITREOUS CHINA WALL MOUNTED LAVATORY WITH ACCESSORIES.
N-141 IS METERED FAUCET. FAUCET, LAVATORY, CENTERSET MIXING,
#B-0890-WS
ALT. NOTE: BAG HOLDER NO LONGER INCLUDED WITH PRODUCTION
LINE - REFER TO EQUIP. PLAN FOR ORIENTATION AND NUMBER OF LINES
EACH SYSTEM = WATER HEATER #43600.0014, BRACKET #13125.0003,
SHELF #12599.0000, SCALE INHIBITOR #39000.0001
W/ ROOF MOUNTED CONDENSERS HOSHIZAKI FRANCHISEES CAN USE
HOSHISAKI KMS-1230
COMBO, TB, #105181, BUDGETARY 19-4X7X9-2 OAD, MEDIUM BUILDING
PROTOTYPE, INCLUDES LED
K-XX1 7 SHELVING 24X42X86, 5-TIER SPG / ISS (ALTERNATE: METRO) #TBD
K-XX2 13 SHELVING 24X48X86, 5-TIER SPG / ISS (ALTERNATE: METRO) #TBD
K-XX3 1 SHELVING 24X42X66, 4-TIER SPG / ISS (ALTERNATE: METRO) #TBD
SEE PLAN FOR OPENING DIRECTION.
"DARK BRONZE" ANODIZED FINISH
B-XX1 1 X TANKLESS WATER HEATERS (SEE PLUMBING DWGS.) NAVIEN #NPE-240A X X
B-100 0 X DOOR AND FRAME LOCKNET SERVICE DOOR AS SCHEDULED ON PLANS
F-452 0 X OVAL BABY CHANGING STATION DIAPER-DEPOT #4300
L-150 1 X SECURITY DOOR DANGER SIGN ADVERCO #ADVCUSTOM ORDERED DIRECT FROM YRFS
P-147 1 X COFFEE BREWER AERO MFR. CO., INC. #100215 X
U-131 2 MOUNTING PLATE SSP
R-031 1 FRY STATION REACH-IN HALF HIGH FREEZER (RIGHT HINGED) DELFIELD #E30601054 X
U-130 1 KIOSK TOWER ONE PER STORE
B-XX2 2 X XLERATOR SURFACE MOUNTED HAND DRYER EXCEL #XL-C X
09/23/21
1
TYP.
1
TYP.
OPEN TO
BELOW
1
TYP.
1
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
2
TYP.
3
3
3
4
5
6
6
6
6
6
6
66
6
6
6
7 7
8
9
9
9
9
9
9
10
10
10
10 10 14
1010
10
10 10
11
11
12
13
ROOF
PLAN
A3.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
ROOF PLAN 1/4"=1'-0" 1
ROOF PLAN NOTES KEY NOTES
NOT USED
N
1 EXISTING ROOFING SYSTEM TO REMAIN. PROTECT FROM DAMAGE. PATCH
AND REPAIR AS REQUIRED.
EXISTING PARAPET CAP FLASHING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING R.T.U. TO REMAIN. PROTECT FROM DAMAGE.
EXISTING EXHAUST HOOD EXHAUST SYSTEM. SEE MECHANICAL
DRAWINGS.
EXISTING RESTROOM EXHAUST FAN TO BE REMOVED. SEE MECHANICAL
DRAWINGS FOR NEW.
EXISTING ROOFTOP BRACING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING WALK-IN COOLER AND FREEZER CONDENSERS TO REMAIN.
PROTECT FROM DAMAGE.
EXISTING ROOFTOP EQUIPMENT TO REMAIN. PROTECT FROM DAMAGE.
EXISTING SCUPPER AND DOWNSPOUT TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING FABRIC AWNINGS TO BE REMOVED AND REPLACED WITH NEW.
SEE EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.
EXISTING ICE MACHINE CONDENSERS TO BE REMOVED AND REPLACED
WITH NEW.
NEW FRUITISTA CONDENSER.
EXISTING ROOF LADDER TO REMAIN. PROVIDE SECURITY DOOR AT
BOTTOM OF LADDER (1/8" ALUMINUM SHEET METAL DOOR. WIDTH OF
LADDER. WITH ALUMINUM PIANO HINGE. ALUMINUM LOCK LOOP AND
HANDLE / LATCH HINGE WELDED TO DOOR AND CONTINUOUS BRACKET
AT 36" A.F.F.)
EXISTING FABRIC AWNING TO BE REMOVED IN ITS ENTIRETY. PATCH AND
REPAIR EXISTING ADJACENT FINISHES AS REQUIRED.
WATERPROOFING:
1. PAINT UNDERSIDE OF PARAPET CAP FLASHING WITH FACTORY
BONDED PAINT GRIP OR PRIMER.
2. TOP NAILING AT PARAPET CAP FLASHING WILL NOT BE ACCEPTED.
3. PENETRATIONS IN ROOFING MEMBRANE AND FLASHING SHALL ONLY
BE MADE AS INDICATED ON THE DRAWINGS OR SPECIFICATIONS.
4. SEE SPECIFICATIONS FOR SEALANT SPECIFICATIONS.
5. ALL SHEET METAL FLASHING SHALL BE 22 GA. MIN.
MISCELLANEOUS:
1. ROOF PENETRATIONS CLOSER THAN 12" FROM ANOTHER WILL NOT BE
ALLOWED.
2. EXHAUST FANS MIN. 10'-0" AWAY FROM ALL AIR INTAKE / SUPPLY.
3. LOCATE WALK-IN CONDENSERS ON ROOF ONLY IF REQUIRED BY
CODE.
2
3
4
5
6
7
8
9
10
11
12
13
14
09/23/21
2 2 2 2 2
2
3
TYP.
4
TYP.
5
TYP.
6
TYP.
7
TYP.
8 8 8 88
9
EXTERIOR
ELEVATIONS
A4.0
SOUTH ELEVATION1/4"=1'-0" 1
NOT USED 2
QTY ITEM DESCRIPTION ELEC. QTY ITEM DESCRIPTION ELEC.
NOTE: SIGNAGE UNDER SEPARATE PERMIT
V-04.42 1 42" SWINGING BELL PURPLE LOGO - FACE LIT
(13.53 S.F.)X
V-09.14W 1 14" WHITE CHANNEL LETTERS - WALL
MOUNTED (9.9 S.F.)X
V-XXX V-XXX
GENERAL NOTES CANOPY AND BUILDING ACCENT SCHEDULE SIGN SCHEDULE
EXTERIOR FINISH SCHEDULE EXTERIOR ELEVATION KEY NOTES
1 EXISTING SIGNAGE TO BE REMOVED AND REPLACED WITH NEW TACO BELL SIGNAGE AS
SCHEDULED. SEE SIGN SCHEDULE FOR ADDITIONAL INFORMATION.
EXISTING METAL FRAMED AWNINGS TO REMAIN. EXISTING FABRIC TO BE REMOVED AND
REPLACED WITH NEW PURPLE FABRIC (COLOR TO MATCH SW PURPLE TB2603C).
EXISTING CONCRETE BLOCK TO REMAIN. PROTECT FROM DAMAGE.
EXISTING BRICK VENEER TO REMAIN. PROTECT FROM DAMAGE.
EXISTING BUILT UP E.I.F.S. CORNICE TO REMAIN. PROTECT FROM DAMAGE.
EXISTING PARAPET CAP FLASHING TO REMAIN. PROTECT FROM DAMAGE.
EXISTING CONCRETE ACCENT TO REMAIN. PROTECT FROM DAMAGE.
EXISTING ANODIZED ALUMINUM FRAMED GLAZING SYSTEM TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING ANODIZED ALUMINUM FRAMED ENTRY DOOR TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING DRIVE-THRU WINDOW TO REMAIN. PROTECT FROM DAMAGE.
REMOVE EXISTING DRIVE-THRU WINDOW. INFILL WALL. NEW CONSTRUCTION TO MATCH
EXISTING ADJACENT CONSTRUCTION.
EXISTING METAL FRAMED AWNING TO BE REMOVED. PATCH AND REPAIR ADJACENT
FINISHES TO REMAIN AS REQUIRED.
MISCELLANEOUS:
1. SEE SHEET A1.1 "WINDOW TYPES" FOR WINDOW ELEVATIONS.
SEALERS (REFER TO SPECIFICATIONS):
1. SEALANT AT ALL WALL AND ROOF PENETRATIONS.
2. SEALANT AT ALL WINDOW AND DOOR FRAMES AT HEAD AND JAMB. DO NOT SEAL
SILL AT WINDOWS.
3. APPLY NEOPRENE GASKET (CONTINUOUS) BETWEEN BUILDING AND CANOPY.
"CRITICAL" DIMENSIONS:
1. REQUIRED CLEAR OPENING WIDTH TO ENSURE COORDINATION WITH STANDARD
SIGNAGE / BUILDING ELEMENTS DIMENSIONS.
NOTE: NO EXTERIOR SIGNS ARE WITHIN THE SCOPE OF WORK COVERED BY THE
BUILDING PERMIT APPLICATION. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR COORDINATING THE INSTALLATION OF ALL EXTERIOR SIGNS AND INSTALLATION OF
REQUIRED BLOCKING AND ELECTRICAL CONNECTIONS FOR FINAL APPROVED SIGNS.
SYMBOL AREA MANUFACTURER COLOR CONTACT INFORMATION
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
EXTERIOR ARTWORK SCHEDULE
QTY. ITEMX
0 CAMO PATTERN- EXPRESSION PANEL (4'X8')G-510
0 G-511
0 G-512
CAMO PATTERN - EXPRESSION PANEL (4'X8')
CAMO PATTERN- EXPRESSION PANEL (4'X8')
1
HARDIE REVEAL PANEL JAMES HARDIE REVEAL PANEL SYSTEM - CYBERSPACE (SW7076), SEMI-GLOSS
SEE A7.2
2
AWNINGS SIGNAGE VENDOR BLACK BY SIGNAGE VENDOR
-
3
CORNER TOWER WESTERN STATE T-GROOVE 24 GA. PAINTED 18" PANEL - WEATHERED RUSTIC
-
4
5
6 -
7 -
8
9
10
11 -
0G-607 CAMO PATTERN - ART FILM (WINDOW)
SEE A7.2
SEE A7.2
SEE A7.2
SIDING JAMES HARDIE ARTISAN V-GROOVE 144"L X 8.25"W; 7" EXPOSURE COMES PRIMED FOR PAINT
- WORLDLY GRAY (SW7043), SEMI-GLOSS
DOWNSPOUTS - WORLDLY GRAY (SW7043), SEMI-GLOSS
HARDIE TRIM JAMES HARDIE HARDIE TRIM 5/4 SMOOTH 1" X 5.5" - CYBERSPACE (SW7076), SEMI-GLOSS
SCUPPERS - WORLDLY GRAY (SW7043), SEMI-GLOSS
HOLLOW METAL DOOR - SW PURPLE TB2603C, SEMI-GLOSS
NOT USED
RECESS OF SIDE ENTRY PORTAL WESTERN STATE T-GROOVE 24 GA. PAINTED 18" PANEL - WEATHERED RUSTIC
HARDIE REVEAL PANEL JAMES HARDIE REVEAL PANEL SYSTEM - SW PURPLE TB2603C, SEMI-GLOSS
0G-607 CAMO PATTERN - EXTERIOR MURAL (17'X8')
SEE A7.2
SEE A7.2
METAL PARAPET CAP - 24 GA. GALVANIZED - CYBERSPACE (SW7076) KYNAR 500 COATING
10
NEW PURPLE FABRIC TO BE INSTALLED ON EXISTING
METAL FRAMED AWNINGS (SIZE VARIES - VERIFY ON SITE
PRIOR TO ORDERING) COLOR TO MATCH SW PURPLE
TB2603C
EXISTING EXTERIOR WALL FINISHES, PARAPET CAP,
SCUPPERS, DOWNSPOUTS, WINDOWS, ENTRY DOORS,
ETC. TO REMAIN, UNLESS NOTED OTHERWISE.
2
3
4
5
6
7
8
9
10
11
12
2
09/23/21
EQUAL EQUAL
EQ. 1'-2" 8 1/8"3'-6" EQ.1
1
V-04.42
V-09.14W
2 2 2
12 2 2
2
22 2 2
3
TYP.
4
TYP.
5
TYP.
6
TYP.
7
TYP.
3
TYP.
4
TYP.
5
TYP.
6
TYP.
7
TYP.
3
TYP.
4
TYP.
5
TYP.
6
TYP.
7
TYP.
8
88 8
9
10
11
EXTERIOR
ELEVATIONS
A4.1
NORTH ELEVATION1/4"=1'-0" 1
WEST ELEVATION 1/4"=1'-0" 2 EAST ELEVATION1/4"=1'-0"3
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
EXISTING EXTERIOR WALL FINISHES, PARAPET CAP,
SCUPPERS, DOWNSPOUTS, WINDOWS, ENTRY DOORS,
ETC. TO REMAIN, UNLESS NOTED OTHERWISE.
EXISTING EXTERIOR WALL FINISHES, PARAPET CAP,
SCUPPERS, DOWNSPOUTS, WINDOWS, ENTRY DOORS,
ETC. TO REMAIN, UNLESS NOTED OTHERWISE.
EXISTING EXTERIOR WALL FINISHES, PARAPET CAP,
SCUPPERS, DOWNSPOUTS, WINDOWS, ENTRY DOORS,
ETC. TO REMAIN, UNLESS NOTED OTHERWISE.
09/23/21
NOTE: G.C. TO PROVIDE BLOCKING
AND INSTALL THE LADDER
ROOF
DECK
6"4'-0"TYP.ASREQUIRED8" 15'-10"(FIELD VERIFY WITH FINAL INSTALLED ROOF STRUCTURE HEIGHT)1'-6"1'-0"TYP.1/8" MOLDED
POLYURETHANE
SAFETY CAPS
2 1/2" ALUMINUM
CHANNEL
SIDERAIL (6005-T5)
2 1/4" SERRATED
ALUMINUM TREAD
(6005-T5)
16'
17 7/8"7 1/4"PLAN BRACKET DETAIL
4 1/2 "8 1
/
2
"3"1/4"
9/16"40" MINIMUMKITCHEN HOOD EXHAUST FAN
HINGED BASE FOR SERVICING /
CLEANING
SEAL WITH APPROVED
MATERIAL
PRE-FABRICATED VENTILATED
CURB EXTENSION
NEMA 3R FUSED DISCONNECT,
MOUNT TO HINGED BASE, SEE
ELECTRICAL
SHEET METAL COUNTER
FLASHING - WRAPS TOP AND
OUTSIDE OF CURB, EXTENDING
OVER BASE FLASHING
PRE-FABRICATED GALVANIZED
STEEL CURB WITH INSULATION
DUCT WRAP - SEE MECHANICAL
MINIMUM 16 GAUGE WELDED
DUCT
NOTE: EXHAUST FAN SHALL
BE LEVEL WITHIN 1/8" OVER
WIDTH OF CURB
SCHEDULE ROOF DECK AND ROOF OPENING SUPPORT
4"
SL
O
P
E
SLOP
E
24 GAUGE G.I. COVER PLATE
SET INTO SEALANT BEAD
APPLIED ALONG BOTH SIDES OF
JOINT - SECURE USING SCREW
THRU STEEL / NEOPRENE
WASHER CENTERED OVER 1/4"
GAP BETWEEN ADJACENT
SECTIONS OF NEW COPING.
SCREW THRU NEOPRENE
WASHER @ 30" O.C. @ INSIDE
FACE ONLY
SECURE OUTSIDE FACE
OF METAL SECTIONS
USING TWO NAILS THRU
SLOTTED HOLES UNDER
COVER PLATE
24 GAUGE G.I. CAP FLASHING
COUNTER FLASH @
EXTERIOR FACE
NOTE: JOINTS ARE TO OCCUR AT 10'-0" MAX.8" MIN.STANDARD CURB BASE, FASTEN
PER MANUFACTURERS
RECOMMENDATIONS
ELECTRICAL CONDUIT
GALVANIZED NAILS @ 6" O.C.
SCREW THRU NEOPRENE
WASHER, 3 PER SIDE
PREFABRICATED CUSTOM CURB
FLASHING
(2) TAPERED 2X12 WOOD CURB
OVER 2X SECURED TO DECK
ROOFING MATERIAL
8" MIN.TYPICAL VENT PIPE
S.S. BAND POSITIONED 1/4"
FROM TOP OF STACK FLASHING
DURO-LAST PRE-FABRICATED
VENT STACK FLASHING
DURO-LAST ROOFING
MATERIAL OVER RIGID
INSULATION
2X SOLID BLOCKING STACKED
WITH DRILLED HOLE FOR PIPE
PENETRATION
SEALANT AT PENETRATION
SCHEDULE ROOF
DECK AND ROOF
OPENING SUPPORT
NOTE:
EXHAUST FAN SHALL
BE LEVEL WITHIN 1/8"
OVER WIDTH OF CURB
SCHEDULE ROOF DECK AND
ROOF OPENING SUPPORT
FLASHING PAINT TO
MATCH FINISH
ROOFING PER ROOF
PLAN
(2) - 2X6 STUDS
EACH SIDE OF
BLOCKING
LEDGER OR TRUSS
SEE PLAN
STRAP CONNECTION
PER STRUCTURAL
EXTERIOR FINISH
1/2" PLYWOOD
SHEATHING 4"NOTES: 8" MINIMUMT.O. CURB TO T.O. ROOF1'-2"HVAC UNIT
UNIT COUNTER FLASHING WITH
NEOPRENE PERIMETER GASKET
1" HEAD NAILS AT 6" O.C.
KNOCK-DOWN FLAT METAL CURB
- SEE SCOPE OF WORK
5/8" PLYWOOD SECURED TO
CURB
CURB FLASHING
TAPERED SLEEPER TO LEVEL
CURB
ROOFING MATERIAL OVER RIGID
INSULATION
NOTE: RTU SHALL BE
LEVEL WITHIN 1/8" OVER
LENGTH OF EQUIPMENTSCHEDULE ROOF DECK AND ROOF OPENING SUPPORT
60 MIL. TPO SINGLE PLY ROOF
MEMBRANE
BUILT-UP RIGID INSULATION
CRICKET OVER ROOFING RIGID
INSULATION OVER 2X FRAMING
SLOPE PER ROOF PLAN
PLYWOOD ROOF DIAPHRAGM
PROVIDE A WOOD NAILER TO MATCH THE THICKNESS OF THE WALL FINISH.
APPROXIMATELY 1" THICK IS TYPICAL BUT MAY VARY. TOP OF WOOD NAILER
SHALL BE FLUSH WITH TOP OF WALL FINISH. THE WOOD NAILER SHALL EXTEND
AT LEAST 1/2" INCH BEYOND THE LOWER HORIZONTAL EDGE OF THE PARAPET
COPING TO ALLOW FOR PROPER FASTENING.
FASTENERS USED TO ATTACH THE COPING TO WOOD NAILERS, MUST BE SPACED
NO GREATER THAN 18" ON CENTER.
ALLOW FOR 1/8" EXPANSION GAP BETWEEN 10'-0" LENGTHS OF COPING. PROVIDE
COPING JOINT COVERS BETWEEN ENDS OF COPING PIECES AND AT CORNERS.
JOINT COVERS SHOULD BE MADE FROM THE SAME MATERIAL AS THE COPING
AND SHOULD LAP THE JOINTS A MINIMUM OF 6" ON EITHER SIDE. JOINT COVERS
SHALL BE FASTENED THE SAME WAY AS THE COPING.
FIBER CANT STRIP SLOPED 1/4":12" TOWARDS ROOF.
ROOF MEMBRANE RUN UP AND OVER FIBER CANT TO LAP WOOD BLOCKING AT
FRONT FACE.
FACTORY PAINTED 24 GAUGE METAL COPING WITH 4" DROP FRONT, BACK AND
ENDS (WHERE SHOWN).
WALL FINISH AS SCHEDULED.
DOUBLE 2X TOP PLATE.
PLYWOOD SUBSTRATE. SEE SHEET A1.0 AND STRUCTURAL FOR ADDITIONAL
DETAILS.
3 6
5
4
1
2
7
9
8
9
1
2
3
4
5
6
7
8
9
BUILDING PARAPET
NOTE:
SEE ALSO PLUMBING DRAWINGS
HOT WATER INTAKE OR
EXHAUST FLUE
PIPE CLAMP-BOLT TO ANGLE,
TYP. OF 2
2x2x1/8" ANGLE - LAG BOLT TO
PARAPET @ BLKG. & CUT &
BEND @ 90 DEG. ANGLE
14"
MIN.
MEMBRANE ROOF
FLASHING BOOT
ROOFING
MEMBRANE
RIGID INSUL. BD.
FASTEN PVC
TUBE TO TRUSS
BELOW ROOF
DECK WITH GALV.
STEEL U-CLAMP
WOOD TRUSS
CHORD (TYP.)
WOOD TRUSS
WEB (TYP.)
EXTEND PVC PIPE A
MIN. OF 24" BELOW
PLYWD. ROOF DECK
ROOF PLYWOOD
UTILITY LINES FOR
ROOF TOP
EQUIPMENT
EXT. CLOSED CELL
INSULATION FOAM TO
SEAL PIPE
6" DIA. WHITE 40
SCHEDULE PV PIPE. 2-90
DEGREE PLUS VERTICAL
THRU ROOF
8"MIN. MIN. 24 GA. G.I. CAP
FLASHING SECURE W/ SCREW
THRU STEEL/EPDM WASHER
AS NEEDED FOR PROPER
SECUREMENT (4 SIDES)
2x6 @ 16" O.C.
5/8" CDX PLYWOOD
CAP SHEET OVER
TOP OF SLEEPER
EXTEND DOWN
SIDES BY 2"
(2) 2x12, RIP FOR
LEVEL PLATFORM
BASE FLASHING
ROOFING MATERIAL
NOTE:
SET SUPPORTS ON SOLID
NON-RIBBED NEOPRENE, AND
SECURE LAG BOLTS THROUGH
STEEL/NEOPRENE WASHER
SCHEDULE ROOF DECK AND
ROOF OPENING SUPPORT
CONTACT LEE COBB WITH
DURO-LAST AT 800-434-3876
FOR ROOF MEMBRANE
QUESTIONS.
1/2" PLYWOOD SHEATHING
MINIMUM 3/4" FURRING
MINIMUM 1/16" EPDM
HARDIE REVEAL PANEL
VERTICAL SIDING
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
FLASHING AND DRAINAGE PER
FINISH REQUIREMENTS
HEADER - SEE STRUCTURAL
R.O.
EXTERIOR INTERIOR
SECTION A-A
30" 36"X
10 1/8"9 3/8"1 1/2"7 1/4" 3 1/4"3 1/2" 3 1/2"
HATCH MATERIAL:
GALVANIZED STEEL (PRIME PAINTED)
COVER - 14 GA. GALV STEEL
FRAME COVER - 14 GA. GALV STEEL
FRAME CURB - 14 GA. GALV STEEL
COVER LINER - 22 GA. GALV STEEL
HATCH FINISH:
GALV - PRIME PAINTED
MANUFACTURER:
PRECISION LADDERS, LLC OR EQUAL
OUTSIDE PADLOCK
PROVISION
OUTSIDE HANDLE
VINYL GRIP
COVER REINFORCING
CHANNEL (TYPICAL)
1" FIBERGLASS
INSULATION
EXTRUDED RUBBER
GASKET
HEAVY DUTY HINGE
FRAME COVER W/
3/8" PIVOT PIN
COVER LINER
ONE POINT LOCKING
UNIT
INSIDE PADLOCK
PROVISION
FRAME CURB PRESSURE
INTENSIFIER
HOLD OPEN ARM
VINYL GRIP
CLEAR OPENING
CLEAR OPENINGA A4'-6" LENGTH OR LESS ONE
POINT LATCH GREATER THAN
4'-6" TWO POINT LATCH
CLEAR OPENING
HOLD OPEN
ARM
ONE POINT
LOCKING
UNIT
HEAVY DUTY
HINGE
PRESSURE
INTENSIFIER
NOTES:
1. ALL MOUNTING HARDWARE TO BE SUPPLIED BY OTHERS.
2. FOR OPERATING EFFICIENCY, HATCH HARDWARE VARIES BY SIZE EXAMPLE
MODEL #: PH- A/G OPENING SIZE IN FEET-INCHES (PH-G2630)
CONSTRUCTION
A6.0
CON. @ STUD AND @ BLOCKING 3"=1'-0" 17 W.H. FLUE / INTAKE PIPE SUPPORT N.T.S. 13 PIPE HOOD N.T.S. 9 COPING JOINT DETAIL1 1/2"=1'-0"5
EXHAUST FAN CURB 1 1/2"=1'-0" 18 HVAC CURB 3"=1'-0" 14 PARAPET CAP DETAIL3"=1'-0"2
EXHAUST FAN CURB 1"=1'-0" 19 EQUIPMENT PLATFORM SUPPORT 3"=1'-0" 15 ROOF LADDER AND HATCH3"=1'-0"7
NOT USED 20 CRICKET 3"=1'-0" 16 SEALED PIPE FLASHING 1 1/2"=1'-0" 12 PARAPET CORNER 3"=1'-0" 8 ROOF LADDERN.T.S.4
DETAILS -
ROOF
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
09/23/21
NOTES
2X WOOD STUDS
PLYWOOD SUBSTRATE FOR EXTERIOR WALLS
FLASHING TAPE AT ALL VERTICAL PARAPET TRANSITIONS. EXTEND TAPE 12"
OUTWARD AND UPWARD FROM CORNER AS SHOWN. LAP CORNERS WITH
ANGLED TAPE AS SHOWN TO INSURE FULL COVERAGE AT CORNERS
DOUBLE 2X TOP PLATE.
PAINTED 24 GAUGE PARAPET COPING. SLOPE 1/4:1 TOWARDS ROOF WITH
FIBER CANT STRIPS UNDER COPING. LAP FRONT AND BACK EDGE 2" DOWN
VERTICAL FACE. LAP EXPOSED COPING EDGE EXPOSED ENDS AT
VERTICAL PARAPET TRANSITION.
WRAP WALL FINISH ONTO VERTICAL FACE OF PARAPET TRANSITION
EXTERIOR FINISH ON OUTER SURFACE OF EXTERIOR WALL. THICKNESS
PER THE EXTERIOR ELEVATIONS ON SHEET A300 AND A301.
TERMINATION BAR AT VERTICAL TRANSITION OF WALL FINISH AND
MEMBRANE ROOFING. SEAL VERTICAL GAP BETWEEN TERMINATION BAR
AND FINISH PER ROOFING MANUFACTURER SPECIFICATIONS.
ROOFING MEMBRANE ON BACKSIDE OF PARAPET.
1 - PRE-WATERPROOFING
2 - FINISH-WATERPROOFING
1 TO
2
IMPORTANT: ONLY FASTEN PARAPET COPING ALONG THE FRONT AND BACK VERTICAL EDGE. NEVER ON TOP OF COPING.
1
3
4
2
5
6
5
4
7
8
9
1
2
3
4
5
6
7
8
9
BUILDING PAPER OVER PLYWOOD
BACK SIDE OF BOX
FRONT OF BOX
FLASHING TAPE AROUND BOX
8 x 8 x 4 STEEL HOSE BIB BOX.
HOSE BIB
SUBSTRATE
BACK SIDE OF PLYWOOD SHEATHING
HOSE BIB BOX
COLD WATER LINE TO HOSE BIB
2x6 WOOD WALL STUD
NOTE: HOSE BIB BOX SHALL BE ACUDOR-ARVB OR EQUAL
LOCKING DOOR
EXTERIOR FINISH
HARDIE REVEAL PANEL SIDING
MIN. 1/16" EPDM
MIN. 3/4" FURRING
1/2" PLYWOOD SHEATHING
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
SA FLEXIBLE
COUNTERFLASHING
VENT STRIP
PRE-FINISHED FLASHING W/
DRIP EDGE RETURN 3" HORIZ.
AND 4" VERT. OVER WRB AT
WALL OPENING
SEALANT W/ BACKER ROD
SILICONE. ANODIZED
ALUMINUM WINDOW FRAME -
SEE WINDOW SCHEDULE.
ALIGN FRAME AS SHOWN.
FACE OF HARDIE PANEL
BEYOND
5/8" GYP. BD.
RETURN WRB 5"
OVER WALL
OPENING SIDES
HEADER - SEE
STRUCTURAL
STOREFRONT
BACK PLATE TO
SUPPORT SHIM
3/8" SHIM
LAG BOLT &
WASHER
EXTERIOR INTERIOR
R.O.
R.O.
7/8"
SILICONE
SEALANT OVER
LAG BOLT
LOG BOLT &
WASHER
3/8" PLASTIC
SHIM
SOLID SURFACE
SILL
FLASHING TAPE
OVER BLDG.
PAPER
5/8" GYPSUM
BOARD
NOTE: SEE DETAIL 16/6.1 FOR ADDITIONAL INFORMATION REGARDING
WATER PROOFING AT AND NEAR WINDOWS AND DOORS
ANODIZED ALUMINUM
WINDOW FRAME - SEE
WINDOW SCHEDULE. ALIGN
FRAME AS SHOWN.
ANODIZED ALUM. SILL
RECEPTOR. W/ WEEP HOLES
SEALANT W/ BACKER ROD
ANODIZED ALUM. FLASHING
HORIZONTAL EDGE TRIM
HARDIE REVEAL PANEL SIDING
SILL FLASHING
MIN. 1/16" EPDM
MIN. 3/4" FURRING
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
1/2" PLYWOOD SHEATHING
EXTERIOR INTERIOR
NOTE: SEE DETAIL 16/6.1 FOR ADDITIONAL INFORMATION REGARDING
WATER PROOFING AT AND NEAR WINDOWS AND DOORS
EXTERIOR
INTERIOR
SEALANT W/ BACKER ROD
ANODIZED ALUMINUM
FLASHING TO MATCH THE
DOOR FRAME COLOR
SEALANT FLASHING
HARDIE REVEAL PANEL SIDING
1/2" PLYWOOD SHEATHING
BLUESKIN VP WATER
RESISTIVE AIR BARRIER
MEMBRANE
MIN. 3/4" FURRING
MIN. 1/16" EPDM
5/8" GYPSUM BOARD
ANODIZED ALUMINUM
WINDOW FRAME - SEE
WINDOW SCHEDULE
HOLD 3/8" SPACE FOR
BACKER ROD
ANODIZED ALUMINUM
WINDOW FRAME - ALIGN
FRAME WITH FACE OF OPAQUE
PANEL FRAME
SEALANT W/ BACKER ROD
ANODIZED ALUM. FLASHING
SELF-ADHERED
SILL FLASHING
FACE OF HARDIE PANEL
BEYOND
EXISTING
GYPSUM BOARD
20 GA. S.S. WALL
GUARD - TOP OF
SILL JAMB TO
JAMB - ATTACH
W/ CONST.
ADHESIVE
EXTERIOR INTERIOR
BACKER AND
SEALANT ROD
SILL FLASHING
ANODIZED ALUM.
FLASHING TO MATCH THE
DOOR FRAME COLOR
OVER AIR SPACE
SHIM
20 GA. S.S. WALL GUARD -
TYP. @ SILL, JAMB &
HEAD. ATTACH W/ CONST.
ADHESIVE
EXTERIOR INTERIOR
PLYWOOD SHEATHING TO
MATCH EXISTING BLDG.
BLUESKIN VP WATER RESISTIVE
AIR BARRIER MEMBRANE
PAINTABLE METAL FLASHING
SEALANT & BACKER ROD
SERVICE DOOR - SEE DOOR
SCHEDULE - ALIGN FRAME
WITH FACE OF SHEATHING 4" @ HEAD2" @ JAMB3/8" SHIM, LAG
BOLT & WASHER
HEADER - SEE
STRUCTURAL
GYPSUM BOARD
SHTG. TO
MATCH EXIST.
CONDITIONS
2X FRAMING
EXTERIOR INTERIOR
1"MAX.NOTE: SEE FLOOR FINISH PLAN FOR FLOOR FINISHES
EXISTING SLAB / FOUNDATION
(SHOWN SHADED)
ADA COMPLIANT
ALUMINUM
THRESHOLD -
SET IN SEALANT
FINISH FLOOR
OVER CONCRETE
SLAB
SERVICE DOOR -
SEE DOOR
SCHEDULE AND
SCOPE OF WORK
EXTERIOR
INTERIOR
BACKER AND SEALANT ROD
SILL FLASHING
ANODIZED ALUM. FLASHING
TO MATCH THE DOOR FRAME
COLOR OVER AIR SPACE
EXISTING GYPSUM BOARD
1"MAX.EXTERIOR INTERIOR
PRE-MOLDED
EXPANSION
JOINT
ADA COMPLIANT
ALUMINUM
THRESHOLD -
SET IN SEALANT
CONCRETE SLAB
ANODIZED
ALUMINUM DOOR
- SEE DOOR
SCHEDULE
1/2" PLYWOOD
SHEATHING
MIN. 3/4" FURRING
MIN. 1/16" EPDM
HARDIE TRIM
2X FRAMING
5/8" GYPSUM BOARD
BACKER AND SEALANT ROD
SILL FLASHING
ANODIZED ALUM. FLASHING
TO MATCH THE DOOR FRAME
COLOR
BLUESKIN VP WATER
RESISTIVE AIR BARRIER
MEMBRANE
INSULATED GLASS
DOOR, SEE SCHEDULE
MIN. 3/4" FURRING
MIN. 1/16" EPDM
HARDIE BOARD
PAINTED METAL
FLASHING
HORIZONTAL EDGE
TRIM
EXTERIOR GRADE
PLYWOOD
BLUESKIN VP WATER
RESISTIVE AIR BARRIER
MEMBRANE
J-BOX MOUNT TO
SUPPORTING
STRUCTURE. PROVIDE
POSITIVE SEAL FROM
BOX TO WEATHER
BARRIER
CONDUIT / PIPE
AIR SEAL
2X STRUCTURE
BACKWRAP OPENINGS
2X FRAMING HEADER - SEE
STRUCTURAL
1/2" GYP. BD.5 1/2" IF 2X47 1/2" IF 2X62" 1/2"
DOUBLE STUDS AT JAMB AND HEAD
WITH ANCHOR STRAP
HM FRAME
WD. DOOR
SEALANT
5/8" GYPSUM
BOARD
PROVIDE GYP. BD. RETURN
TO FRAME
EXISTING MASONRY VENEEREXISTING EXTERIOR WALL (SHADED)SEALANT
EXISTING
MASONRY
VENEER
EXISTING EXTERIOR WALL (SHADED)
EXISTING
GYPSUM BOARD
PROVIDE GYP. BD.
RETURN TO FRAME
EXISTING EXTERIOR WALL (SHADED)EXISTING MASONRY VENEER
2" MIN. TO 4" MAX. E.I.F.S.
FINISH. SEE ALSO 1/A6.2
NEW OR EXIST.
STOOP PENDING
LOCATION
PLYWOOD SHEATHING
EXTERIOR FINISH MATERIAL
BLOCKING AS REQUIRED
PVC (SCH 40) BUSHING - FILL WITH
SEALANT
FASTENER AS REQUIRED
WASHER
NOTE:
INSTALL BUSHING AFTER E.I.F.S.
APPLICATION HAS HARDENED.
DRILL HOLE SLIGHTLY LARGER
THAN BUSHING THROUGH
INSULATION ONLY, STOP AT
PLYWOOD. CAULK OPENING PRIOR
TO INSERTING FASTENER TO SEAL
PENETRATION.
CONSTRUCTION
A6.1
PARAPET CAP & TRANSITION N.T.S. 13
JAMB SERVICE DOOR 3"=1'-0" 9 WINDOW SILL AT DRIVE-THRU3"=1'-0" 5
STOREFRONT DOOR SILL 3"=1'-0" 10 WINDOW JAMB AT DRIVE-THRU 3"=1'-0" 6 TYPICAL WINDOW SILL3"=1'-0"2
CONNECTION THRU EXIST. FINISH 1"=1'-0" 11
HOSE BIB BOX 3"=1'-0" 12 THRESHOLD @ SERVICE DOOR3"=1'-0" 8 NOT USED4
DETAILS -
DOORS / WINDOWS
HEAD / JAMB @ SERVICE DOOR 3"=1'-0" 7 TYPICAL WINDOW JAMB3"=1'-0"3
TYPICAL WINDOW HEAD3"=1'-0" 1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
DOOR JAMB 3"=1'-0" 16
CO2 FILL / J-BOX 3"=1'-0" 17
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
CASED OPENING DETAIL 3"=1'-0" 14
HEAD/JAMB @ H.M. DOOR 3"=1'-0" 15
STANDARD DETAIL. FIELD
VERIFY ACTUAL CONDITIONS
STANDARD DETAIL. FIELD
VERIFY ACTUAL CONDITIONS
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
NOT
USED
09/23/21
24" MIN.EQ. NOTE: CAULK ALL SEAMS AT WALL SURFACE.1" 2" FLANGE
BENT 90 DEG.EQ. EQ. 16 GA. BRUSHED
STAINLESS STEEL. 1/2"
HEM ON TOP, FRONT AND
BOTTOM EDGES.
BOTTOM EDGE OF SPLASH
GUARD SHALL BE EVEN W/
THE EDGE OF THE
HIGHEST ADJ. SINK.
EXTEND FRONT OF PANEL
TO FRONT EDGE OF ADJ.
SINK. APPROX. 24" (SEE
PLAN)
1/2" RAD. EASED CORNER
(TYP.)1"(4) #12 S.S. WOOD
SCREWS 3/4" LG. W/ S.S.
WASHERS.
SE
E
P
L
A
N
6" 1'-6"FASTEN 2X BLOCKING
TO FACE OF ADJACENT
WALL OR TRUSS
PLUMBER'S TAPE STRAP
7" DIAMETER OPENING IN
CEILING TILE
6" PVC
SYRUP LINE BUNDLE
THROUGH CEILING
SECTION VIEW
PANEL WALL
FOOD GRADE RTV SEALANT
INTERIOR BASE COVE TRIM
FLOORING AS SCHEDULED
CONCRETE PAD
HIT FASTENER
1 1/4" TEK SCREW
DYNATROL SEALANT
4 1/2"
MIN.
4 1/2"
MIN.
NOTE:
VIEW IS LOOKING UP AT WALL
BEHIND SERVICE COUNTER AND
BOTTOM OF MENU BOARD SOFFIT
MONITOR. SEE
SHEET A2.0
MONITOR BASE
ATTACHMENT.
PROVIDE WD. BLKG.
WALL BEHIND
DATA OUTLET. SEE
ELECTRICAL
DRAWINGS
ELECTRICAL OUTLET.
SEE ELECTRICAL
DRAWINGS
TILE OR STONE
SUBSTRATE
TILE OR STONE
TILE OR STONE
SUBSTRATE
TILE OR STONE
DRINK LINES FROM WATER FILTER SYRUP
RACK AND CO2 CANISTER IN BACK OF
KITCHEN ABOVE CEILING
LINE OF CEILING PERIMETER
STAINLESS STEEL DRINK LINE
CHASE. 4"D X 10"W X 30"H
WITH 1" FLANGES - FASTEN
WITH STAINLESS STEEL
SCREWS CLEAR CAULK
DRINK LINE THROUGH
OPENINGS IN TABLE
OUTLINE OF DRINK
AND ICE MACHINE
SUBSTRATE PER PLAN
FRP
CONTINUOUS SOLID
BLOCKING BETWEEN
STUDS AT CEILING LINE
CEILING TILE AND GRID
WALL FINISH PER INTERIOR
ELEVATIONS
WALL SUBSTRATE PER
SHEET A1.0
COVE BASE TILE - SET
FLUSH WITH FLOOR TILE
COVE BASE TILE - SET
FLUSH WITH FLOOR TILE
SILICONE SEALANT
WALL FINISH PER INTERIOR
ELEVATIONS
WALL SUBSTRATE PER
SHEET A1.0
SANITARY COVE BASE TILE
- SET FLUSH WITH FLOOR
TILE
J-MOLD SET IN SILICONE
SEALANT FILL J-MOLD W/
SILICONE PRIOR TO
INSTALLING FRP, WIPE OFF
EXCESS
WALL FINISH PER INTERIOR
ELEVATIONS
WALL SUBSTRATE PER
SHEET A1.0
WALL FINISH PER INTERIOR
ELEVATIONS
WALL SUBSTRATE PER
SHEET A1.0
COVE BASE TILE - SET
FLUSH WITH FLOOR TILE1'-0"WALL SUBSTRATE PER SHT.
A1.0
WALL FINISH PER INTERIOR
ELEVATIONS
12" HIGH CEMENT BOARD
J-MOLD SET IN SILICONE
SEALANT - FILL J-MOLD W/
SILICONE PRIOR TO
INSTALLING FRP, WIPE OFF
EXCESS
SILL GASKET - TYP.
COVE BASE TILE - SET
FLUSH W/ FLOOR TILE
1/2" PLYWOOD SHEATHING
WALL SUBSTRATE PER SHT.
A1.0
WALL FINISH PER INTERIOR
ELEVATIONS
12" HIGH CEMENT BOARD
SILL GASKET - TYP.
COVE BASE TILE - SET
FLUSH W/ FLOOR TILE
SILICONE SEALANT
5/8" GYPSUM BOARD
3/4"3 1/2"SEALANT
CHAIR RAIL
WALL COVERING
WAINSCOTING
NOTE: SEE INTERIOR
ELEVATIONS FOR FINISHES
12"CEMENT BOARDSILICONE SEALANTSEE FLOOR PLAN6'-0" MAX.3 1/2"EQ. EQ.8"
EQ. EQ.2" X 2" X 14 GAUGE STEEL TUBE
WELDED TO 3 1/2" X 8" X 3/8"
THICK STEEL PLATE, 5'-0" O.C.
STEEL PLATE BOLTED TO SLAB
WITH (2) 5/8" DIA. HILTI KB-TZ.
IMBED 3 1/8" ICC-ESR-1917
1"1"
WALL CAP, SEE FINISH PLANS
AND FURNITURE / DECOR
DRAWINGS
BLACK REVEAL, PAINTED
2X4 FRAMING AT 16" O.C., TYP.
1/2" PLYWOOD SHEATHING
WAINSCOT AS SCHEDULED
TILE BASE AS SCHEDULED
5"5" HIGH CEMENT BOARD
BEHIND BASE TILE
BOTTOM TRACK WITH
POWER-DRIVEN FASTENERS @
16" O.C. MAX. ICC-ESR-1752
FOH WALL FINISH
FRP PANEL AND TRIM
DEEPER GROUT BACKING
@ FOH BASE TILE
TRIM CORNER OF FOH
BASE TILE
FOH TILE BASE
BOH TILE BASE
DEEPER GROUT BED @
FOH FLOOR TILE FLOAT TO
BOH TILE LEVEL
THINNER GROUT BASE BEHIND THE BOH TILE
BASE BECAUSE BOH TILE BASE IS THICKER THAN
THE FOH BASE. NOTE: THIS WILL TYP. OCCUR OH
SHORT WALLS ONLY.
NOTE: THIS DETAIL SHOW A 90 DEGREE CORNER. ADAPT THIS DETAIL
AND APPLY WHERE WALLS EXTEND INTO SPACE.
FASTEN S.S. WITH
CONSTR. ADHESIVE
EXTEND S.S. WALL
GUARD BEYOND
SURFACE OF WALL.
THE DEPTH OF THE
TILE AND RETURN
TO THE WALL.
20 GA. S.S. WALL
GUARD FROM TOP
OF TILE BASE TO
CEILING
GROUT LINE
FRP WALL FINISH
S.S. WALL GUARD
FLUSH WITH
SURFACE OF FRP
TILE WALL BASE
S.S. WALL GUARD
FLUSH WITH TILE
FLOOR
FLOOR TILE
FINISH
A6.3
SCHLUTER JOLLY CORNER GUARD N.T.S. 17 SPLASH GUARD 1"=1'-0" 9 BASE @ DINING EXT. SIDE WALLS3"=1'-0" 5
S.S. CORNER & END WALL GUARD N.T.S. 14 CHAIR RAIL DETAIL 3"=1'-0" 10 BASE @ EXT. WALL3"=1'-0" 6
SCHLUTER CORNER GUARD N.T.S. 15 RETHERMALIZER RAIL DETAIL1'-0"=1'-0" 11
BASE @ KITCHEN WALL 3"=1'-0" 16 RETHERMALZIER RAIL @ FLOOR 3"=1'-0" 12 BASE @ DINING ROOM INT. WALL3"=1'-0" 8 BASE @ KITCHEN WALL3"=1'-0"4
DETAILS
BASE IN RESTROOM 3"=1'-0" 7 KITCHEN FINISH AT CEILING3"=1'-0"3
WALL MOUNT MONITOR1 1/2"=1'-0" 2
WALK-IN FLOOR / BASE1 1/2"=1'-0" 1
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
TILE BASE TRANSITION 1'-0" = 1'-0" 13
NOT
USED
NOT
USED
NOT
USED
LOW WALL DETAIL 3" = 1'-0" 18
SYRUP BUNDLE CLG. 1"=1'-0" 19
SYRUP CHASE ON WALL 1"=1'-0" 20
NOT
USED
NOT
USED
09/23/21
OPEN TO STRUCTURE
1/2" GYP. BD.
5/8" TYPE 'X' GYP. BD. TAPED
AND FINISH SMOOTH FOR
PAINT FINISH AS
SCHEDULED
WOOD STUD
FRAMING AS
SCHEDULED
NOTE: VERIFY ASSEMBLY WITH
TRUSS MANUFACTURER WHERE
1 HR ASSEMBLY IS REQUIRED
FURRING
CHANNEL AT
24" O.C. 20
GAUGE 2" MAX.
8 GA. HANGER WIRE
TO STRUCTURE
ABOVE, 4'-0" O.C. WITH
4 WIRES SPLAYED
90^ IN 4 DIRECTIONS,
45 DEG. MAX. FROM
CEILING PLANE
TYPE "S" SCREW
@ 8" O.C.
5/8" GYP. BD. TYPE "X" ALL
EDGES SUPPORTED
1 1/2" COLD ROLLED
STEEL AT 48" O.C., 20
GAUGE
20 GAUGE WIRE45°45°4
5
°45°LATERAL BRACING: 4-12 GA. WIRES SECURED
TO MAIN RUNNER WITHIN 2" OF CROSS RUNNER
INTERSECTION AND SPLAYED 90° FROM EACH
OTHER AT ANGLE NOT TO EXCEED 45° FROM
THE PLANE OF THE CEILING TYP. @ 12'-0" EA.
WAY BEGINNING 6'-0" MAX. FROM WALL.
ANCHOR WIRES TO
STRUCTURE ABOVE
MAIN RUNNER CROSS RUNNER
AT SUSPENDED CEILING
VERTICAL HANGER WIRE AT
4'-0" O.C. W/ (2) 1 1/2" X 9" GA.
STAPLES @ LOOP AND (1)
ACROSS LAP. 3 FULL TURNS
MINIMUM WITHIN 3" LENGTH
AT OPEN GRID: VERTICAL
SUSPENSION WITH
THREADED ROD PER OTHER
DETAILS
NOTE:
∂ALL WIRES 12 GA.
∂PROVIDE 6" CLEARANCE AT ALL PIPES AND DUCTS, ETC.
∂BRACING WIRES MUST BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH
A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200
POUNDS OR THE ACTUAL LOADS, WHICHEVER IS GREATER, WITH A SAFETY FACTOR
OF 2
ACOUSTICAL CEILING TILE WITH
WALL ANGLE
2X4 WOOD STUD FRAMING
5/8" TYPE 'X' GYP. BD. TAPED AND
FINISH SMOOTH FOR PAINT
FINISH AS SCHEDULED.
1/2" GYP. BD. TAPED AND FINISH
SMOOTH FOR PAINT FINISH AS
SCHEDULED
ACOUSTICAL CEILING TILE
WITH WALL ANGLE
METAL STUD
TYPE 'X' GYPSUM BOARD
TAPED AND FINISH
SMOOTH FOR PAINT
FINISH
WALL
BEYOND
5/8" GYPSUM BOARD
ACOUSTICAL CEILING TILE
WITH WALL ANGLE
4'-0" 12'-0" 4'-0"MAX.SEE
PLAN
16'-0" 12'-0" 4'-0"3/8"MIN. CLR.8" ELEVATION 45°3/8"
MIN. CLR.
MIN. #12 GAUGE
ACOUSTICAL CEILING
NOTE: TILE 2 ADJACENT WALLS TO
CEILING MAIN AND CROSS RUNNER
CEILING GRID USES #12
GAUGE SPLAY WIRE
HANGERS AT 45° AND 90°
TO EACH OTHER (4 WIRES)
BEGINNING 48" FROM
STARTING POINT OF GRID
AND TILE LAYOUT AND IN
BOTH DIRECTIONS AT 12'-0"
THEREAFTER ALL
CLEARANCES. TIES TO
WALL, ETC. TO CONFORM
TO STATE AND LOCAL
CODES.
LATERAL FORCE BRACING MEMBERS MUST BE SPACED A MINIMUM OF
6" FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT
PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES.
BRACING WIRES MUST BE ATTACHED TO THE GRID AND TO THE
STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN
LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL LOADS,
WHICHEVER IS GREATER, WITH A SAFETY FACTOR OF 2.
LIGHT FIXTURE (LESS THAN 56 LBS.)
PROVIDE MINIMUM OF 2 SCREWS AT
OPPOSITE CORNERS OF SUPPORT
WIRES, OR SCREW ON T-BAR SAFETY
CLIPS AT SIDES OR ENDS.
TWO (2) NO. 12 GAUGE WIRES
MUST BE SECURED FROM LIGHT
AND MECHANICAL FIXTURES AT
OPPOSING CORNERS ALONG
WITH FIXTURES DIAGONAL
WIRES MAY BE SLACK
FOUR (4) NO. 12 GAUGE WIRES
MUST BE ATTACHED TO THE
GRID MEMBERS WITHIN 3" OF
EACH CORNER OF EACH
FIXTURES WHEN INTERMEDIATE
CEILING SYSTEMS ARE USED
SUSPENDED CEILING GRID
CEILING
A6.4
GYPSUM BOARD TRANSITION 3"=1'-0" 17 SUSPENDED ACOUSTICAL CEILING 3"=1'-0" 9 CEILING HEADER TRANSITION3"=1'-0"5
SUSPENDED CEILING GRID 1'-0"=1'-0" 10
DETAILS
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
GYPSUM BOARD CEILING3"=1'-0" 6
CEILING TRANSITION 3"=1'-0" 11
LIGHT FIXTURE AT SUSPENDED CEILING N.T.S. 8
ALLOWABLE CEILING SPANS - L/2403
CEILING SPAN TABLE NOTES:
(EXAMPLE: 6" = 600 X 1/100 INCHES) ALL
MEMBER DEPTHS ARE TAKEN IN 1/A100
INCHES. FOR ALL "T" SECTIONS MEMBER
DEPTH IS THE INSIDE DIMENSION.
MEMBER DEPTH: FLANGE WIDTH:
(EXAMPLE: 1 5/8" = 1.625"
~ 162 X 1/100 INCHES)
ALL FLANGE WIDTHS ARE
TAKEN IN 1/A100 INCHES
STYLE:
(EXAMPLE: STUD OR JOIST SECTION = S )
THE FOUR ALPHA CHARACTERS UTILIZED BY
THE DESIGNATOR SYSTEM ARE:
S = STUD OR JOIST, T = TRACK, U = CHANNEL,
F = FURRING
(EXAMPLE: 0.054 IN. = 54
MILS; 1 MIL = 1/1000 IN.)
MATERIAL THICKNESS IS
THE MINIMUM BASE
METAL THICKNESS IN
MILS. MINIMUM BASE
METAL THICKNESS
REPRESENTS 95% OF
THE DESIGN THICKNESS
-
MATERIAL THICKNESS:
600 S 162 54
1. VALUES ARE FOR SINGLE SPANS.
2. ALLOWABLE CEILING SPAN CALCULATIONS BASE ON 33KSI YIELD STRENGTH STEEL.
3. FOR FULLY BRACED CEILINGS, USE MID-SPAN BRACED VALUES.
4. END BEARING LENGTH = 1" MINIMUM.
SECTION (MIL.)
4 PSF
LATERAL SUPPORT OF COMPRESSION FLANGE
UNSUPPORTED JOIST SPACING
(IN.) .O.C.
MID-SPAN JOIST SPACING
(IN.) O.C.
12" 16" 24" 12" 16" 24"
NOTE: ALL JOIST INFORMATION IS BASED ON STEEL STUD MANUFACTURERS ASSOCIATION
(SSMA) ICC ESR-3064P
362S125
362S125
362S125
362S125
362S125
362S137
362S137
362S137
362S162
362S162
400S125
400S125
400S125
400S125
400S137
400S137
400S137
400S162
400S162
600S125
600S125
600S125
600S125
600S137
600S137
600X162
600X162
INDICATES THAT WEB STIFFENERS ARE REQUIRED AT ENDS
18
27
30
33
43
27
33
43
33
43
27
30
33
43
27
33
43
33
43
27
30
33
43
33
43
33
43
9'-3"
10'-8"
11'-0"
11'-5"
12'-8"
12'-0"
12'-11"
14'-3"
14'-8"
16'-2"
10'-11"
11'-4"
11'-9"
13'-0"
12'-4"
13'-3"
14'-7"
15'-0"
16'-7"
12'-5"
12'-9"
13'-2"
14'-6"
14'-11"
16'-3"
16'-11"
18'-5"
8'-7"
9'-10"
10'-2"
10'-7"
11'-8"
11'-2"
11'-11"
13'-2"
13'-7"
14'-11"
10'-1"
10'-5"
10'-10"
12'-0"
11'-5"
12'-3"
13'-6"
13'-11"
15'-3"
11'-6"
11'-10"
12'-3"
13'-4"
13'-9"
15'-0"
15'-8"
17'-0"
7'-7"
8'-10"
9'-1"
9'-5"
10'-5"
10'-0"
10'-8"
11'-8"
12'-2"
13'-4"
9'-1"
9'-4"
9'-8"
10'-8"
10'-3"
10'-11"
12'-0"
12'-6"
13'-8"
10'-4"
10'-8"
11'-0"
11'-11"
12'-5"
13'-5"
14'-1"
15'-3"
12'-8"
15'-0"
15'-6"
16'-2"
17'-9"
17'-2"
18'-4"
20'-0"
20'-10"
22'-8"
15'-5"
16'-0"
16'-7"
18'-3"
17'-7"
18'-9"
20'-7"
21'-5"
23'-4"
17'-11"
18'-5"
18'-11"
20'-6"
21'-5"
23'-1"
24'-5"
26'-4"
11'-7"
13'-11"
14'-4"
14'-10"
16'-5"
15'-11"
16'-11"
18'-6"
18'-11"
20'-7"
14'-3"
14'-9"
15'-3"
16'-10"
16'-4"
17'-4"
19'-0"
19'-10"
21'-7"
16'-6"
17'-1"
17'-7"
19'-0"
19'-10"
21'-5"
22'-8"
24'-4"
10'-0"
12'-4"
12'-10"
13'-3"
14'-8"
14'-3"
15'-2"
16'-7"
16'-6"
18'-0"
12'-9"
13'-2"
13'-8"
15'-0"
14'-8"
15'-7"
17'-0"
17'-9"
19'-4"
14'-9"
15'-3"
15'-10"
17'-0"
17'-10"
19'-3"
20'-5"
21'-11"
NOT USED4
NOT USED 7
NOT USED 13
CEILING HEADER TRANSITION 3"=1'-0" 14 NOT USED 18
DIGITAL MENU BOARD N.T.S. 20
STANDARD DETAIL - SITE CONDITIONS MAY VARY. FIELD VERIFY AND
COORDINATE WITH SUPPLIER ANY ADJUSTMENTS NECESSARY.
09/23/21
2X4
2X42X4 2X4 2X4 2X62X62X62X42X42X4
B-2
T-2
B-2
T-2
B-2
T-2
B-2
T-2
B-2
T-2
B-2
T-2
1
1111
1
1
1
1212
12
12
12
12
8
A6.3 (TYP.)
8
A6.3 (TYP.)
7
A6.3 (TYP.)
VESTIBULE #1
FREEZERCOOLER WASHING
PREP
TB COOK
OFFICE
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
PASSAGE
B-2
T-2
1
12
W-3
W-3
2
2
2
2
2
2
2
3
3 3
6
T-2
4
4
4
4
4
4
5
7
A6.3 (TYP.)4'-0"5
B-2
T-2
1
12
6
2
2
8
8
9
EQ. EQ.7
10
FRP-1
10
FRP-1
10
FRP-1
10
FRP-1
10
FRP-1
10
FRP-1
FINISH
FLOOR
A7.0
PLAN
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
FINISH FLOOR PLAN1/4"=1'-0" 1
N
FLOOR FINISH NOTES KEY NOTES
1. DENOTES FINISH MATERIAL. REFER TO SHEET A7.2 FOR FINISHES.
2. TILE JOINT (U.N.O.)
- QUARRY FLOOR TILE: 1/4"
- PORCELAIN FLOOR TILE: 3/16"
- GLAZED WALL TILE: 1/8"
- BASE, TRIM AND ACCESSORIES: MATCH ADJOINING TILE UNITS
3. TILE INSTALLATIONS REQUIRE MANUFACTURER'S STANDARD MOLDED CORNERS AT BOTH INSIDE AND OUTSIDE
CORNERS.
4. ALL BASE TILE SHALL BE SANITARY COVE STYLE WITH 3/8" MIN. RADIUS UNLESS NOTED OTHERWISE.
5. SEE SCOPE OF WORK SHEETS FOR RESPONSIBILITIES.
6. PROVIDE CLEAR SILICONE CAULK WHERE F.R.P. STOPS AT TOP OF COVE BASE.
7. TILE CHIPPING AROUND CORE DRILL HOLES FOR SEATING FIXTURE WILL NOT BE ACCEPTED.
XX 1 6" COVE TILE BASE. SEE DETAIL.
EXISTING TILE FLOORING AND SANITARY COVE TILE BASE IN BACK OF HOUSE TO REMAIN. PROTECT FROM
DAMAGE. PATCH GROUT WHERE NEEDED. STEAM CLEAN AND DEGREASE FLOOR PRIOR TO EQUIPMENT MOVE IN.
EXISTING METAL PANEL FLOORING AND METAL BASE IN DRY STORAGE / COOLER / FREEZER TO REMAIN. PROTECT
FROM DAMAGE.
EXISTING FLOOR DRAINS TO REMAIN.
PROVIDE FLOOR DRAIN AS REQUIRED IN NEW RESTROOMS. FLOOR DRAIN TO BE FLUSH WITH FLOOR FINISH.
FLOAT FLOOR TILE FOR FLUSH TRANSITION.
START POINT FOR FLOOR TILE. (FULL TILE)
ALIGN NEW FLOOR FINISH TRANSITION WITH WALL, AS SHOWN.
PROVIDE FLOOR DRAIN AS REQUIRED UNDER NEW SELF-SERVE SODA STATION TABLE. FLOOR DRAIN TO BE
FLUSH WITH FLOOR FINISH.
NEW F.R.P. WALL FINISH AT KITCHEN / B.O.H. AS REQUIRED.
SANITARY TILE BASE IN RESTROOM.
INSTALL FLOOR TILE IN A STRAIGHT STACK BOND.
2
3
4
5
6
7
8
9
10
11
12
09/23/21
S
S
S
S
S
CL-3
9'-6"
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
OFFICE
DRY STORAGEDRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
3
3
4
5
6
11
12
13
14 24
15
17
4
18
77
77
7
7 7
7
7
7
23
CL-2
8'-6" (E)±
CL-2
8'-6" (E)±
EXIST
8'-6" (E)±
EXIST
8'-6" (E)±
EXIST
8'-6" (E)±
CL-2
8'-6" (E)±EXIST
7'-6" (E)±
EXIST
7'-6" (E)±
EXIST
7'-6" (E)±
CL-16
8'-6"
P-1
CL-16
8'-6"
P-1
2
2
2
8
8
8
9
9 9
16
19
19
19
19
19
21
TYP.
21
TYP.
21
TYP.
21
TYP.
21
TYP.
7'-0"
FRP-1
25
(E)±
26 26
26
PASSAGE
EQ. EQ.EQ. EQ.
EQ. EQ.EQ.EQ. EQ.EQ.EQ.EQ. 6122'-4"4'-7 1/2"4'-7" 2'-2"
1'-3"6'-3 1/8" 8'-4 3/4"2'-6" 2'-6" 2'-6"4'-6 1/4" 2'-2" 1'-9 1/4" 6'-2" 6'-2" 1'-11" 5'-10 3/4" 6'-2" 6'-2"
EQ. EQ.EQ. 3'-0" 3'-0" 3'-0" EQ.\A1;EQ.16
22
CL-16
9'-0"
P-1
CL-1
9'-6"
CL-1
9'-6"
CL-1
9'-6"
CL-1
9'-6"
CL-1
9'-6"
10 10
10
10
10 27
27
EQ. EQ.EQ. EQ.1
20
TYP.
17
1
1
1
1EQ.EQ. EQ. EQ.
4
20
TYP.
REFLECTED
CEILING
A7.1
PLAN
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
REFLECTED CEILING PLAN 1/4"=1'-0" 1
N
KEY NOTES
1 LOCATE GRID PER EQUAL / EQUAL DIMENSIONS SHOWN.
AT AREA SHOWN HATCHED. EXISTING CEILING GRID TO BE
PAINTED AS SCHEDULED. REPLACE EXISTING CEILING TILES WITH
NEW AS SCHEDULED.
NON-INSULATED BUNDLED SYRUP LINES FOR DRINK SYSTEM. SEE
SCOPE OF WORK.
6" DIAMETER PVC STUB THROUGH CEILING, SEE DETAIL 19/A6.3
EXISTING HOOD TO REMAIN. PROTECT FROM DAMAGE. MODIFY
ANSUL HEAD LOCATIONS AS REQUIRED FOR NEW EQUIPMENT
SCHEDULED.
FOR ROUGH FRAMING OPENINGS SEE AIR DEVICE SCHEDULE (TYP.
ALL RESTROOMS).
REPLACE EXISTING AWNINGS WITH NEW. SEE EXTERIOR
ELEVATIONS FOR ADDITIONAL INFORMATION.
EXISTING CEILING TILE AND GRID TO REMAIN IN BACK OF HOUSE,
U.N.O. PROTECT FROM DAMAGE.
EXISTING METAL CEILING AT DRY STORAGE / COOLER / FREEZER
TO REMAIN. PROTECT FROM DAMAGE.
COORDINATE LOCATIONS AND QUANTITIES OF SPEAKERS AT
DINING / CUSTOMER AREA CEILING WITH OWNER.
UTILITY CHASE BY 3RD PARTY VENDOR TO CEILING.
EMERGENCY DUAL HEAD FIXTURE. SEE ELECTRICAL DRAWINGS.
SECURITY STROBE LIGHT, REFER TO ELECTRICAL DRAWINGS.
EXISTING FAN COIL FOR WALK-IN COOLER TO REMAIN. PROTECT
FROM DAMAGE.
ALERT LIGHT BOX FOR 3-COMP POWER SOAK MOUNTED AT
CENTERLINE OF BOX 7'-11" A.F.F.
AT AREA OF NEW WALL CONSTRUCTION - MODIFY CEILING TILES
AND GRID AS REQUIRED.
STAINLESS STEEL SYRUP CHASE ON WALL. SEE 20/A6.3
WATER INLET CHASE FOR CHEESE MELTER SCREWED TO HEATED
AIR SCREEN.
EXISTING DIFFUSERS AT BACK OF HOUSE TO BE REMOVED AND
REPLACED WITH NEW.
NEW FRONT OF HOUSE MECHANICAL DIFFUSERS. REFER TO
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
REPLACE EXISTING LIGHTING IN BACK OF HOUSE WITH NEW LED
LIGHT FIXTURES.
EXTEND EXISTING SOFFIT AS REQUIRED, IN CONFIGURATION
SHOWN, TO NEW WALL SCHEDULED.
DIGITAL MENU BOARDS INSTALLED DIRECT TO WALL / SOFFIT. SEE
ALSO A8.0 AND 20/A6.3. G.C. TO PROVIDE PLYWOOD BACKING AND
BLOCKING IN WALL FOR MOUNTING AS REQUIRED. SEE
ELECTRICAL DRAWINGS FOR POWER / DATA REQUIRED.
RELOCATE EXISTING FAN COIL FOR WALK-IN FREEZER AS
REQUIRED FOR NEW FREEZER WALL INSTALLATION.
EXISTING SOFFIT TO REMAIN. PROTECT FROM DAMAGE. PAINT AS
SCHEDULED.
EXISTING DRY STORAGE / COOLER / FREEZER LIGHT FIXTURE TO
BE REPLACED WITH NEW LED FIXTURE TO MATCH EXISTING TO BE
REMOVED.
ALIGN SOFFIT WITH WALL, AS SHOWN.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
REFLECTED CEILING PLAN NOTESCEILING SYMBOL LEGEND
DIMENSIONS:
1. ALL DIMENSIONS ARE TO FACE OF FINISH U.N.O.
CEILING FINISHES:
1. REFER TO ROOM FINISH SCHEDULE (SEE SHEET A7.2) FOR CEILING FINISHES.
SUSPENDED CEILING:
1. ACOUSTICAL PANEL INSTALLATION: INSTALL ACOUSTICAL PANELS WITH EDGES IN CLOSE CONTACT WITH METAL
SUPPORTS AND IN TRUE ALIGNMENT.
2. ALLOWABLE VARIATIONS FROM FLAT AND LEVEL SURFACE: 1/8" IN 10'-0" MAX.
3. ALLOWABLE VARIATIONS FROM PLUMB OF GRID MEMBERS: AS CAUSED BY ECCENTRIC LOADS, 2° MAX.
4. INSTALL SYSTEM AFTER MAJOR ABOVE CEILING WORK IS COMPLETE. COORDINATE LOCATIONS OF HANGERS WITH
RELATED WORK.
5. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
GYPSUM BOARD CEILING:
1. SUBSTRATE SHALL BE 5/8" THICK GYP. BD.
2. ACOUSTICAL SEALANT: APPLY TO GYP. BD. PANELS AS INDICATED IN SPECIFICATIONS. GYP. BD. FINISHING AND
DECORATING: REFER TO DRAWINGS FOR TEXTURE AND FINISHES.
ELECTRICAL:
1. SEE ELECTRICAL DRAWINGS FOR FIXTURE SCHEDULE.
2'-0" x 4'-0" LED LIGHT FIXTURE
PENDANT LIGHT FIXTURE
PENDANT LIGHT FIXTURE
DOWN LIGHT (ATTACHED TO STRUCTURE) AT OPEN TO
DECK / RECESSED CAN LIGHT AT CEILINGS
1'-0" X 4'-0" LED LIGHT FIXTURE
EXIT / EMERGENCY LIGHT
EMERGENCY LIGHT
DOWN LIGHT AT WALK-IN COOLER / FREEZER (BY WALK-IN
MANUFACTURER)
NEW LED LIGHT FIXTURE IN DRY STORAGE / COOLER /
FREEZER TO MATCH EXISTING TO BE REMOVED
HVAC RETURN AIR GRILLE (SEE MECHANICAL PLANS)
HVAC SUPPLY DIFFUSER (SEE MECHANICAL PLANS)
SEE SHEET A6.4 FOR
STANDARD DETAILS
19
20
21
22
23
24
25
26
27
09/23/21
FINISH
SCHEDULE
A7.2
FLOORING
DESCRIPTION ALTERNATE / NOTE
WALL BASE
MFR: SHERWIN WILLIAMS
TYPE: SW7021
COLOR: SIMPLE WHITE
PRIMER: #023 (WHITE) FRESH START 100%
ACRYLIC
MFR: SHERWIN WILLIAMS
TYPE: TB2603C
COLOR: PURPLE
PRIMER: #023 (WHITE) FRESH START 100%
ACRYLIC
MFR: SHERWIN WILLIAMS
TYPE: SW7076
COLOR: CYBER SPACE
PRIMER: #023 (WHITE) FRESH START 100%
ACRYLIC
MFR: SHERWIN WILLIAMS
TYPE: SW7005
COLOR: PURE WHITE
PRIMER: #023 (WHITE) FRESH START 100%
ACRYLIC
CREATIVE MATERIALS CORP.
CONTACT: ALLISON PICHE
PHONE: 518.452.9694
DIRECT: 518.713.5395
APICHE@CREATIVEMATERIALSCORP.COM
JAMES HARDIE
CONTACT: MATT PETERSEN
PHONE: 707.536.6271
MATTHEW.PETERSEN@
JAMESHARDIE.COM
MARLITE
CONTACT: JOHN DEMATOS
PHONE: 800.877.1221
MOBILE: 217.361.5453
JDEMARTOS@MARLITE.COM
SHERWIN WILLIAMS
CONTACT: SUNNY PATEL
PHONE: 619.990.1920
SUNDEEPKUMAR.PATEL@SHERWIN.COM
WESTERN STATES METAL ROOFING
CONTACT: CAMERON BERG
PHONE: 602.245.8323
CAMERON@WESTERSTATESMETAL
ROOFING.COM
CORIAN
CONTACT: DAVID GREENING
PHONE: 614.975.6700
DAVID.P.GREENING@DUPONT.COM
WOLF GORDON
CONTACT: JESSICA ROSE
PHONE: 213.999.1141
JESSICA.ROSE@WOLFGORDON.COM
MAPEI
CONTACT: LISA FYKE
PHONE: 909.247.5324
LFYKE@MAPEI.COM
USG CORPORATION
CONTACT: TRAVIS TOMANEK
PHONE: 440.541.3972
TTOMANEK@USG.COM
SYM.
DESCRIPTION ALTERNATE / NOTE SYM.
WALL FINISHES
DESCRIPTION ALTERNATE / NOTESYM.
P-1
P-2
P-3
P-4
DESCRIPTION ALTERNATE / NOTE SYM. DESCRIPTION ALTERNATE / NOTESYM.
METAL TRANSITIONS LAMINATES
DESCRIPTION ALTERNATE / NOTE SYM.
CEILINGS
NOT USED CONTACTS
FINISH SCHEDULE LEGEND
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
PAINT SHEEN
CEILING/SOFFIT: FLAT
WALLS: EGGSHELL
TRIM/BOH: SEMI-GLOSS
CR-1
DINING CHAIR RAIL PROVIDED BY DECOR VENDOR
(SEE DECOR PACKAGE) AND INSTALLED BY G.C.
MFR: SW
TYPE: CHAIR RAIL W/ ROUTE
COLOR: SW7043 WORLDLY GRAY SEMI-GLOSS
SIZE: 31/2" H. X 3/4" D.
MFR: WOLF GORDON
TYPE: 'RAMPART' HIGH IMPACT WALL
COVERING
COLOR: FOUNDATION PIGMENT (GOH 12172606)
WC-1
RAILROAD INSTALLATION: THERE SHOULD BE NO
SEAMS ALONG WALLS
MFR: CREATIVE MATERIALS CORP.
TYPE: FORM
COLOR: ICE DECO MIX
SIZE: 8" X 8"
GROUT: MAPEI #47 CHARCOAL, 1/8" JOINT
WIDTH
W-1
RESTROOM ACCENT WALL TILE
MFR: CREATIVE MATERIALS CORP.
TYPE: FORM
COLOR: ICE
SIZE: 8" X 8"
GROUT: MAPEI #47 CHARCOAL, 1/8" JOINT
WIDTH
W-2
RESTROOM WALL TILE
MFR: CREATIVE MATERIALS CORP.
TYPE: SALVAGEWOOD
COLOR: WHITEWASH
SIZE: 3" X 36"
GROUT: MAPEI #01 ALABASTER, 1/8" JOINT
WIDTH
W-3
RUNNING BOND INSTALLATION OFFSET 25%
FRP-1
MFR: MARLITE
TYPE: FIBERGLASS REINFORCED PANEL
COLOR: SMOOTH SURFACE S100 S/2/S WHITE
NOTE: COORDINATE ALL TRIM PIECES WITH
F.R.P. MANUFACTURER
MFR: CREATIVE MATERIALS CORP.
TYPE: QUARRY
COLOR: PURITAN GREY #507
SIZE: 6" X 6"
GROUT: MAPEI #9 GRAY, 1/8" JOINT WIDTH
T-1
KERAPOXY GROUT IEG CQ
MFR: CREATIVE MATERIALS CORP.
TYPE: MOTIF GREY
COLOR: GREY
SIZE: 18" X 18"
GROUT: MAPEI #2 PEWTER, 1/8" JOINT WIDTH
T-2
MFR: CREATIVE MATERIALS CORP.
TYPE: QUARRY
COLOR: PURITAN GREY #507
SIZE: 6" X 6"
GROUT: MAPEI #9 GRAY, 1/8" JOINT WIDTH
B-1
KERAPOXY GROUT IEG CQ
MFR: CREATIVE MATERIALS CORP.
TYPE: MOTIF GREY
COLOR: GREY
SIZE: 6" X 12" COVE BASE
GROUT: MAPEI #2 PEWTER, 1/8" JOINT WIDTH
B-2
DESCRIPTION ALTERNATE / NOTESYM.
CORNER GUARDS
MT-1
TILE EDGE TRIM. SEE 17/A6.3MFR: SCHLUTER
TYPE: JOLLY
COLOR: A 100 AT - SATIN NICKEL ANODIZED
ALUMINUM
SIZE: 3/8"
MT-3
TILE EDGE TRIM. SEE 15/A6.3MFR: SCHLUTER
TYPE: RONDEC
COLOR: ALUMINUM
SIZE: 3/8"
DESCRIPTION ALTERNATE / NOTESYM.
SOLID SURFACE
L-1
MFR: WILSONART
TYPE: 4783K FINISH 7
COLOR: WHITE TIGRIS
OFFICE SHELVING LAMINATE
MFR: WILSONART
TYPE: Y0664K-12
COLOR: MOCHA ASH
SOFT GRAIN FINISH, RR/UTILITY DOORS. VERTICAL
GRADE PRODUCT CODE #362 IS .028" AND
HORIZONTAL GRADE PRODUCT CODE #372 IS .039".
L-2
CG-1
MFR: C.S. GROUP
TYPE: ACROVYN VA SERIES
COLOR: VA-034N #934 PEARL
SIZE: 3/4" X 3/4"
FOR PAINT MATCH P-1
MFR: C.S. GROUP
TYPE: ACROVYN VA SERIES
COLOR: VA-034N #262 DRIFTWOOD
SIZE: 3/4" X 3/4"
FOR PAINT MATCH CR-1 AND WC-1
CG-2
SS-1
MFR: CORIAN
TYPE: LAVA ROCK
COLOR: LAVA ROCK
CL-1
MFR: USG
TYPE: ACT SYSTEM, USG RADAR, CLIMAPLUS
PERFORMANCE SQ. EDGE
COLOR: #107 TAUPE
SIZE: 2'-0" X 2'-0"
GRID: USG DONN BRAND DX/DXL 15/16 TEE
SYSTEM, INTERMEDIATE DUTY #107
TAUPE
CL-2
MFR: USG
TYPE: ACT VINYL ROCK #1140 WASHABLE NON
PERFORATED
COLOR: WHITE
SIZE: 2'-0" X 4'-0"
GRID: WHITE SUSPENDED GRID WITH
ALUMINUM FLAME SPREAD RATING 0-25,
CLASS A
CL-3
CL-4
MFR: USG
TYPE: USG COMPASSO STANDARD
COLOR: #205 FLAT BLACK
SIZE: 10" PROFILE
NOTE: SEE PLANS AND DETAILS FOR MORE
INFORMATION
CL-16
MFR: -
TYPE: GYPSUM BOARD
COLOR: PAINTED PER REFLECTED CEILING PLAN
NOTE: SEE SHEET A6.4 FOR DETAILS
NOTE: SEE SHEET A6.4 FOR DETAILS
NOTE: SEE SHEET A6.4 FOR DETAILS
COUNTERTOPS / 24" DIAMETER TABLE TOP
PAINT SHEEN
CEILING/SOFFIT: FLAT
WALLS: EGGSHELL
TRIM/BOH: SEMI-GLOSS
PAINT SHEEN
CEILING/SOFFIT: FLAT
WALLS: EGGSHELL
TRIM/BOH: SEMI-GLOSS
PAINT SHEEN
CEILING/SOFFIT: FLAT
WALLS: EGGSHELL
TRIM/BOH: SEMI-GLOSS
STO CORP. (E.I.F.S.)
CONTACT: CHUCK DUFFIN
PHONE: 940.894.2092
CDUFFIN@STOCORP.COM
MFR: EGER ADVANTAGE
TYPE: FORMED PVC 2 X 2 TILES
COLOR: WHITE WITH EMBOSSED FINISH
GRID: ARMSTRONG PRELUDE XL 15/16"
EXPOSED TEE
COLOR: PRE-PAINTED WHITE
NOTE: FLAME SPREAD RATING 0-20, CLASS A
NOTE: SEE SHEET A6.4 FOR DETAILS
09/23/21
SS-1 TYP.
G-258
G-280 G-281
G-281
G-280
G-258 G-282
L-043
1
L-043
1
L-043
1
L-043
1
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
2
3
5
5
P-1TYP. P-1 TYP.
P-1 TYP.
P-1TYP.
P-1 TYP.
MT-3
MT-3
W-3
W-3
SS-1 TYP. SS-1 TYP.
SS-1 TYP. SS-1 TYP. SS-1 TYP. SS-1 TYP.
L-043
1
P-1P-1
L-2
P-3
L-2
P-3 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"6" 6"
6"6"
EQ.EQ.
EQ. EQ.
10
A6.3
10
A6.3
10
A6.3
10
A6.3
10
A6.36'-8"TYP.6'-8"TYP.5'-0"5'-0"P-1
OPEN TO
DRIVE-THRU
OPEN TO
KITCHEN
5
MT-3
W-3
6
W-3
B-2TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
P-1 TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
4
P-1TYP.
4'-0"
W-3 6 5
MT-3 EQ.EQ.6'-8"TYP.6'-8"TYP.P-1
10
A6.3
10
A6.3
B
A
4'-0" 3" \A1;3"3'-0"4'-0"3"B-2B-2
B-2B-2
WC-1WC-1
WC-1WC-1
SS-1 SOLID
SURFACE CAP
PROVIDED BY
FURNITURE /
DECOR
VENDOR
SS-1 SOLID
SURFACE CAP
PROVIDED BY
FURNITURE /
DECOR
VENDOR
LINE OF TABLE
OUTLETS TO BE
MOUNTED 4" ABOVE
TABLE HEIGHT
INTERIOR
ELEVATIONS -
A8.0
DINING ROOM
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
1
CUSTOMER AREA ELEVATION 3/8"=1'-0" 1
PASSAGE ELEVATION 3/8"=1'-0" 6
CUSTOMER AREA/DINING ROOM ELEVATION 3/8"=1'-0" 4 CUSTOMER AREA/DINING ROOM ELEVATION3/8"=1'-0"5
DINING AREA ELEVATION 3/8"=1'-0" 7
DINING AREA ELEVATION 3/8"=1'-0" 10
CUSTOMER AREA ELEVATION 3/8"=1'-0" 2
KEY NOTES
DIGITAL MENU BOARD. CENTER VERTICALLY ON SOFFIT. SEE ALSO
20/A6.4
'PLEASE ASK IF YOU NEED ASSISTANCE SIGN'. SMALLWARE
PACKAGE.
SS CORNER / END WALL CHANNEL GUARD, FULL HEIGHT.
CHAIR RAIL.
TILE EDGE TRIM.
STAINLESS STEEL SYRUP CHASE ON WALL.
2
3
4
5
6
CUSTOMER AREA ELEVATION3/8"=1'-0" 3
NOT USED9 QUE WALL ELEVATION 3/8"=1'-0" 8
09/23/21
24" MIN.
42" MAX.18" MIN. 1 1/2"12" 42"
39" TO 41"39" TO 41" 18"16" TO 18"
12" 24"17" TO 19"33" TO 36"(TOP OF G.B.)40" MAX.BOTTOM OFREFLECTIVESURFACE34" MAX.9" MIN. CLR.44" MAX.27"CLEAR20" MAX.
8"34" MAX. TOFOLD DOWNTABLEGRAB BARS,
TYP.
TOILET
PAPER
DISPENSER
DISPENSER
LOCATION
AREA
SANITARY
NAPKIN
DISPOSAL AT
WOMEN'S
FLUSH
CONTROL
AT OPEN
SIDE OF
WATER
CLOSET
DRAIN PIPE,
HOT WATER TO
BE INSULATED
SOAP
DISPENSER
SURFACE
MOUNTED
MIRROR WITH
FRAME
48" MAX.(TO PULL DOWN HANDLE)CL
27" MIN.KNEECLEARANCE48" MAX.2X4 2X4 2X4 2X62X62X6HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
B-310
B-275
B-305
B-410B-300
WOMEN'S MEN'S
4A
4B
4C
4D A8.1
3A
3B
3C
3D A8.1
13
F-014
F-080
F-040
F-060
4
10
F-026
F-131
14
F-050
9
9
F-060
F-504
12
99
F-504
10
10
F-014
F-090
F-040
F-060
9
F-030
F-022
10
F-211
F-040
F-080
9
14
F-050
F-504
U-052
F-014
A B C D
F-270
U-052F-102
5A
5B
5C
5D A8.1
F-131
F-026
F-060
5
F-021
F-504
F-050
F-040 F-080 F-014
F-022
F-030
4'-6"HOLD4 1/2" 6'-5 3/4"±6"9'-0" 6 1/2" 9'-0" 6 1/2"
1'-8" 1'-8"1'-6"1'-6"1'-6"1'-6"B-XX2
N-141
N-146
B-265
B-310
B-275
B-305
B-300
B-XX2
N-141
N-146
B-265
W-1
B-2
B-300
B-305
B-310
B-275
N-146
N-141
15
B-XX2
W-2
B-2
B-300
B-305
B-310
L-2
P-3
(FRAME)
(DOOR)
W-2
B-2
B-XX2
B-265
N-146
N-141
15
W-2
B-2
A B C D
W-1
B-2
B-300
B-305
B-310
B-275
N-146
N-141
15
B-410
B-XX2 B-XX2
B-265
N-146
N-141
15
W-2
B-2
L-2
P-3
(FRAME)
(DOOR)
W-2
B-2
W-2
B-2
B-300
B-305
B-310
A B C D
B-241 B-241
B-241
B-241
ENLARGED
PLANS AND
A8.1
ELEVATIONS
1. PROVIDE PROPER BLOCKING AT WALL RECESSED MOUNTED
ACCESSORIES.
2. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE
INSTALLED PER ADA REQUIREMENTS. REFER TO DETAIL 6/A8.1.
3. REFER TO FLOOR PLAN NOTE FOR BLOCKING AND SUBSTRATE
NOTES.
4. REFER TO DETAIL 6/A8.1 FOR MOUNTING HEIGHTS AND
CLEARANCES OF ACCESSORIES AND FIXTURE.
5. ALL DIMENSIONS THIS DRAWING ARE TO FINISH SURFACE.
6. SEE SHEET A2.1 FOR EQUIPMENT SCHEDULE.
FIXTURE HEIGHTS1/2"=1'-0" 6
GENERAL NOTES
KEY NOTES
1 NOT USED.
NOT USED.
TELEPHONE TERMINAL BOARD.
DESK LAMP.
UNDER COUNTER KEYBOARD TRAY.
NOT USED.
NOT USED.
NOT USED.
EXISTING SHELF TO REMAIN. PROTECT FROM DAMAGE.
COUNTER BY G.C. - FINISH WITH PLASTIC LAMINATE (L-1)
DUCT SMOKE DETECTOR RESET SWITCH.
TECH-IN-A-BOX (WALL MOUNT RACK ENCLOSURE CABINETS):
REFER TO ELECTRICAL DRAWINGS. G.C. TO PROVIDE BLOCKING
WHERE REQUIRED.
DOOR IS OPTIONAL. COORDINATE WITH OWNER.
PROVIDE POWER FOR F-050.
PROVIDE POWER FOR N-146.
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
2
3
4
5
6
7
8
9
11
12
13
14
15
10
ENLARGED RESTROOM PLAN 3/8"=1'-0" 1 ENLARGED OFFICE PLAN3/8"=1'-0" 2
N N
MEN'S RESTROOM ELEVATIONS 3/8"=1'-0" 3
WOMEN'S RESTROOM ELEVATIONS3/8"=1'-0" 4
OFFICE ELEVATIONS 3/8"=1'-0" 5
09/23/21
LOCATE ELEC.
STUB FOR
BUNN HERE
9
S-482
S-274
S-547
S-283
S-285
S-513
5
11
U-238
U-239
U-152
S-349
F-165
U-100
P-417
C-400
S-550
S-286
S-540S-600 B-599
OPEN TO
DRY
STORAGE
OPEN TO
PREP /
UTILITY
OPEN TO
KITCHEN
B-406 N-043
K-221
13
P-452
P-673
K-523
B-381
S-580
S-570
U-011
S-204
15
14
6
2
S-600
S-513
S-285
S-283
S-546
S-274
S-482
S-544
S-547
12
B-599
EXISTING
ELECTRICAL
EQUIPMENT
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
21
P-1 TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
21
P-1 TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
21
P-1 TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
21
P-1 TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
21
P-1TYP.
B-2
WC-1
CR-1
TYP.
TYP.
TYP.
21
P-1TYP.
3
3 3 L-043
20
4
4
8 17 W-3
P-1
22
19
23
EXISTING STAINLESS STEEL
WALL FINISH TO REMAINFRP-1 FRP-1
FRP-1 FRP-1
EXIST
TYP.
EXIST
TYP.
EXIST
TYP.
EXIST
TYP.
EXIST
TYP.
EXIST
TYP.
3 3 3
3 3
F-262 F-262
K-XX3 K-383 R-031
P-452
P-315
P-673
P-550
N-698
N-130
N-171
B-405
K-210
C-107 C-077
FRP-1
B-290
B-241
B-251
B-290
B-241
B-251
P-1
CL-1
FRP-1
FRP-1
F-090
K-490
F-165
7
U-152
U-121
U-100
U-070
U-061
U-100
U-070
U-061
S-483 K-490
F-090
K-490 B-405 F-174
U-152
U-121
F-165
3
S-739
S-274
EXIST
TYP.
1
S-254
INTERIOR
ELEVATIONS -
A8.2
KITCHEN
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
EXISTING OFFICE WINDOW TO REMAIN.
STAINLESS STEEL SYRUP CHASE ON WALL.
SS CORNER / END WALL CHANNEL GUARD. FULL HEIGHT.
EXISTING RECESSED TILE MOP SINK AND FAUCET TO
REMAIN. PROTECT FROM DAMAGE.
STAINLESS STEEL CHASE FOR SYRUP LINES AND ICE
MACHINE REFRIGERANT LINES.
DRIVE-THRU TIMER DISPLAY UNIT.
HOLD-UP BUTTON.
EXISTING ANSUL PULL STATION TO REMAIN.
FILTER FOR HOT WATER SYSTEM.
AREA OF EXTERIOR WALL INFILL. EXISTING OPENING IN
DRY STORAGE WALL PANEL TO REMAIN. PROVIDE S.S.
CLOSURE STRIP AROUND PERIMETER AS REQUIRED.
CEILING MOUNT MONITOR BRACKET.
ADJACENT TABLE TOPS TO BE INSTALLED AT SAME LEVEL.
ADJUST IN THE FIELD AS REQUIRED.
CUT WALL-HANGING TRACK TO ALLOW SPACE FOR CLICK
AND CLEAN SYSTEM.
DT TIMER SIGNAL PROCESSOR.
DT TIMER ETHERNET SWITCH.
NOT USED.
EXISTING WALK-IN COOLER / FREEZER TO REMAIN.
PROTECT FROM DAMAGE.
UTILITY CHASE.
EXISTING STAINLESS STEEL WALL PANEL BEHIND HOOD TO
REMAIN. PROTECT FROM DAMAGE.
DIGITAL MENU BOARD. CENTER VERTICALLY ON SOFFIT.
SEE ALSO 20/A6.4.
CHAIR RAIL.
TILE EDGE TRIM.
EXISTING EXHAUST HOOD TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING TANKLESS WATER HEATER TO REMAIN. PROTECT
FROM DAMAGE.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
KEY NOTES
19
20
21
22
18
23
24
17
VEST. ELEV. 3/8"=1'-0" 1 VESTIBULE ELEVATION 3/8"=1'-0" 2 VESTIBULE ELEVATION 3/8"=1'-0" 3 VESTIBULE ELEVATION3/8"=1'-0"5
VESTIBULE ELEVATION 3/8"=1'-0" 6
VEST. ELEV. 3/8"=1'-0" 4
DRIVE-THRU / TB COOK / KITCHEN ELEVATION 3/8"=1'-0" 7 UTILITY ELEVATION3/8"=1'-0"8
KITCHEN ELEVATION 3/8"=1'-0" 9 WASHING / KITCHEN / SERVING ELEVATION 3/8"=1'-0" 10 UTILITY ELEVATION3/8"=1'-0"11
SERVING / DRIVE-THRU ELEVATION 3/8"=1'-0" 12 UTILITY / PREP ELEVATION3/8"=1'-0" 13
09/23/21
18
P-362C
S-024
C-203
S-065
C-250
18
C-203
S-065
S-023
P-362C
C-250
K-523 K-523 K-523
S-550
B-XX1
24
EXIST
TYP.
K-XX1 K-XX2 K-XX2 K-XX2 K-XX1
EXISTING METAL PANEL
WALL FINISH TO REMAIN
EXISTING METAL PANEL
WALL FINISH TO REMAIN
K-XX1 K-XX2 K-XX2 K-XX2
EXISTING METAL PANEL
WALL FINISH TO REMAIN
EXISTING METAL PANEL
WALL FINISH TO REMAIN
K-XX1 K-XX1
OPEN TO
KITCHEN
K-XX1
P-547
10
FRP-1
INTERIOR
ELEVATIONS -
A8.3
KITCHEN
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
EXISTING OFFICE WINDOW TO REMAIN.
STAINLESS STEEL SYRUP CHASE ON WALL.
SS CORNER / END WALL CHANNEL GUARD. FULL HEIGHT.
EXISTING RECESSED TILE MOP SINK AND FAUCET TO
REMAIN. PROTECT FROM DAMAGE.
STAINLESS STEEL CHASE FOR SYRUP LINES AND ICE
MACHINE REFRIGERANT LINES.
DRIVE-THRU TIMER DISPLAY UNIT.
HOLD-UP BUTTON.
EXISTING ANSUL PULL STATION TO REMAIN.
FILTER FOR HOT WATER SYSTEM.
AREA OF EXTERIOR WALL INFILL. EXISTING OPENING IN
DRY STORAGE WALL PANEL TO REMAIN. PROVIDE S.S.
CLOSURE STRIP AROUND PERIMETER AS REQUIRED.
CEILING MOUNT MONITOR BRACKET.
ADJACENT TABLE TOPS TO BE INSTALLED AT SAME LEVEL.
ADJUST IN THE FIELD AS REQUIRED.
CUT WALL-HANGING TRACK TO ALLOW SPACE FOR CLICK
AND CLEAN SYSTEM.
DT TIMER SIGNAL PROCESSOR.
DT TIMER ETHERNET SWITCH.
NOT USED.
EXISTING WALK-IN COOLER / FREEZER TO REMAIN.
PROTECT FROM DAMAGE.
UTILITY CHASE.
EXISTING STAINLESS STEEL WALL PANEL BEHIND HOOD TO
REMAIN. PROTECT FROM DAMAGE.
DIGITAL MENU BOARD. CENTER VERTICALLY ON SOFFIT.
SEE ALSO 20/A6.4.
CHAIR RAIL.
TILE EDGE TRIM.
EXISTING EXHAUST HOOD TO REMAIN. PROTECT FROM
DAMAGE.
EXISTING TANKLESS WATER HEATER TO REMAIN. PROTECT
FROM DAMAGE.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
KEY NOTES
19
20
21
22
18
23
24
17
UTILITY ELEVATION 3/8"=1'-0" 1 DRY STORAGE ELEVATION 3/8"=1'-0" 2 DRY STORAGE ELEVATION3/8"=1'-0"3
DRY STORAGE ELEVATION 3/8"=1'-0" 4 DRY STORAGE ELEVATION 3/8"=1'-0" 5 GTO DUEL LINE 3/8"=1'-0" 6 GTO DUEL LINE3/8"=1'-0"7
NOT USED9
NOT USED 10
MOP SINK INSTALLATION N.T.S. 8
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
PLUMBING SCHEDULE APLUMBING SCHEDULE A
PLUMBING LEGEND DGENERAL NOTES E
TW
FW
SD
CD
HWR
HW
CW
G
SS
GW
XXX
ITEM FIXTURE MANUFACTURER / MODEL NUMBERDESCRIPTION
F.C.O.FLOOR CLEANOUT OR CLEANOUT TO
GRADE
FW
H.B.
TW
S.O.C.
S.O.V.
P.T.R.V.
C.V.
C.W.
B.V.
E.C.O.
FU
BFP
EXTERIOR CLEAN OUT
COLD WATER BELOW GRADE
FILTERED WATER
PREMIXED TEMPERATURE WATER
SHUT-OFF GAS COCK
PRESS-TEMPERATURE RELIEF VALVE
SHUT-OFF GATE VALVE
BALL VALVE
CHECK VALVE
HOSE BIBB
BACK FLOW PREVENTER
FIXTURE UNIT
WALL CLEANOUTW.C.O.
R.D.
Y.B.
ABBREV. SYMBOLS DESCRIPTION
YARD BOX
ROOF DRAIN
V.T.R.
A.P.
V.B.F.
V.C.P.
A.C.P.
C.I.
U.T.R.
(E)
H.D.
F.D.
F.S.
OFD
A.F.F.
G.L.
(N) NEW
HUB DRAIN
GAS LINE
ABOVE FINISHED FLOOR
FLOOR SINK
OVERFLOW DRAIN
CAST IRON
VITRIFIED CLAY PIPE
UP THRU ROOF
ASBESTOS CEMENT PIPE
EXISTING
FLOOR DRAIN
VENT THRU ROOF
ACCESS PANEL
VENT BELOW FLOOR
G
CW
HW
H.W.R.
V.
C.D.
S.D.
HOT WATER RETURN
CONDENSATE DRAIN
SANITARY VENT
STORM DRAIN
GAS / GAS STUB
HOT WATER / HW STUB
COLD WATER / CW STUB
PLUMBING EQUIPMENT DESIGNATION
KITCHEN EQUIPMENT NUMBER: REFER TO
SOIL OR WASTE (GREASE WASTE)/WASTE STUB
KITCHEN EQUIP. DRAWINGS FOR DESCRIPTION.
SOIL OR WASTE (SANITARY)/ WASTE STUB
X-X 0000
SOIL OR
WASTE VENT COLD
WATER
HOT
WATER
TEMP'D
WATER
WASTE
FU
WATER
FU
FCO 1
FLOOR
CLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED
HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE / MODEL: 6000Z
ZURN / MODEL: Z-1400
WCO 1
WALL
CLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS
PLUG, WITH STAINLESS STEEL ACCESS COVER.
JOSAM / MODEL: 58510
WADE / MODEL: 8560E
ZURN / MODEL: Z-1446-BP
S 3
3-COMP.*
SINK INDIRECT -- 1/2" 1/2" -- -- 3
SINK, FAUCET, 0.65 GPM NOZZLE, DRAIN, & GEN IV POWER SOAK STANDARD, GEN III IS AN
OPTION FOR FRANCHISES
--
--
--
S 4 PREP SINK INDIRECT -- 1/2" 1/2" -- -- 2
SINK, FAUCET, 0.65 GPM NOZZLE, & DRAIN --
--
--
MV 1
MIXING
VALVE -- -- 1/2" 1/2" -- -- --
THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER,
CHECK VALVES SIZE PER PIPE CONNECTIONS.
POWERS SERIES LF495
LAWLER SERIES 310
LEONARD SERIES 170
RO 1
REVERSE
OSMOSIS INDIRECT -- 1/2" -- -- -- --
REVERSE OSMOSIS FILTER SYSTEM
BY OWNER
SEE TO DETAIL 9/P6.0
WADE / SHOKSTOP
JOSAM / MODEL: 75000
ZURN / SHOKTROL
1. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.
2. ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED IN
PLACE.
3. VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISE THE SEWER SYSTEM AS
REQUIRED.
4. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODES. PROVIDE DEEP SEAL
TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS.
5. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL
CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY
INSTALLATION.
6. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE
NON-ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
7. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND
10 FEET FROM ANY OUTSIDE AIR INTAKE.
8. PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.
9. INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER
AND WASTE LINES TO BE CHROME PLATED.
10. PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OF
EQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODE AND
RESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OF
EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THE GAS
METER.
11. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS.
12. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH-IN SCHEDULE & FOR ADDITIONAL WORK TO
BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH-IN PLUMBING AND FINAL CONNECTIONS TO KITCHEN
EQUIPMENT SHALL BE MADE BY THE CONTRACTOR U.O.N.
13. REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS.
14. ALL GAS LINES SHALL BE SUPPORTED SEE SPECS.
15. ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE.
16. PROVIDE WATER HAMMER ARRESTOR FOR ALL HAND SINKS, URINAL WATER LINES AND QUICK CLOSING
EQUIPMENT.
17. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THE
DIAMETER OF THE INDIRECT DRAIN.
18. PRIOR TO COMMENCING WORK ON THIS PROJECT, VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL
EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE
THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY.
19. COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY
DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS.
20. FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION.
BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0" A.F.F.
21. PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TO UNITS AND ALL FINAL
CONNECTIONS REQUIRED FOR OPERATION.
22. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY
FROM WHAT IS SHOWN. THEREFORE, VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO
CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY
FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
23. ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N.
24. ALL WATER LINES SHALL BE FLUSHED PRIOR TO CONNECTING ANY FIXTURES OR EQUIPMENT.
25. PROVIDE ESCUTCHEON PLATES AND SILICONE SEALANT AT ALL UTILITY PENETRATIONS INTO WALLS, CEILINGS,
AND FLOORS. DO NOT USE CAULKS OR EXPANDING FOAMS FOR SEALANT.
26. CVPVC SCHEDULE 40 WASTE PIPE CAN BE SUBSTITUTED FOR BLACK IRON WASTE PIPE WHERE ALLOWED BY
LOCAL MUNICIPALITIES.
27. PEX PLASTIC TUBING AND FITTING CAN BE USED AS AN OPTION, ALL INSTALLATION SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND SHALL COMPLY WITH SECTION
605.10.1 AND SECTION 605.10.2.
WC 1
WATER
CLOSET 4" 2" 1/2" -- -- 4 2
AM. STD. "CADET" / MODEL: 2467.100
KOHLER "HIGHLINE" / MODEL: K-3519
CRANE "ECONMISER" / MODEL: 31888
WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE,
ELONGATED BOWL, ADA COMPLIANT, 1.1 GPF, WITH OPEN FRONT SEAT LESS COVER,
OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLUSHMATE OR EQUAL.
PROVIDE TANK COVER LOCKS. FLUSH LEVERS SHALL BE RIGHT HAND OR LEFT HAND AS
REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE
REQUIREMENTS
DRAIN COLD WATER HOT WATER
FIXTURE NO.
DRAIN
D.F.U.
COLD WATER HOT WATER
D.F.U.
F.U.
C.W.
TOTAL
C.W.
TOTAL
H.W.
F.U.
H.W.
TOTAL
3 - COMPARTMENT SINK * 1 -- -- 3 3 3 3
FLOOR SINK 5 4 20 -- -- -- --
TOTAL - - 67 -- 20.75 -- 14.25
MOP SINK 1 2 2 2.25 2.25 2.25 2.25
RETHERMALIZER* 1 - - -- -- 1.0 1.0
HUB DRAIN 1 3 3 -- -- -- --
FLOOR DRAIN 9 3 27 -- -- -- --
HOSE BIBB/WATER FILTRATION UNIT 2/1 -- -- 2.5:1/1 3.5 -- --
PREP SINK * 1 -- -- 2 2 2 2
HAND SINK 2 2 4 1.5 3 1.5 3
LAVATORY 2 1 2 1.5 3 1.5 3
WATER CLOSET 2 4 8 2 4 -- --
*FIXTURE HAS INDIRECT WASTE TO FLOOR SINK
USE 1-1/2" CW SERVICE
USE 4" SANITARY (MIN)43 DFU
20.75 FU = 20 GPM
USE 1-1/4" HW SERVICE14 .25 FU =17 GPM
DRAIN: GW
COLD WATER:
HOT WATER:
PROBABLE DEMANDS/
AND PIPE SIZING
REQUIREMENTS: USE 4" SANITARY (MIN)24 DFUDRAIN: SAN
GREEN
GREEN
GREEN
FD 1 FLOOR DRAIN
(3")
3" 2" -- -- -- 2 --
LIGHT DUTY ADJUSTABLE PVC WITH THREADED ADAPTOR AND 5" DIAMETER NICKEL BRONZE
RING AND FASTENED GRATE
ZURAM / MODEL: FD-2210
SIOUX CHIEF 842
OATEY 72000
FS 1 FLOOR SINK 4" 2" -- -- -- 6 --
LIGHT DUTY, ACID RESISTANCE, WHITE PVC FLOOR SINK W/ 12" SQURE WHIT PVC HALF GRATE
AND STAINLESS STEEL DEBRIS BUCKET WITH LIFTING HANDEL.
SIOUX CHIEF / MODEL: 861-4PNDW
FS 2 FLOOR SINK 4" 2" -- -- -- 6 --
PVC 12" SQUARE FLOOR SINK, 6" DEEP, WITH ALUMINUM DOME STRAINER
AND NICKEL BRONZE HINGED TOP.
SIOUX / MODEL: 861-4-PND
GI 1
GREASE
INTERCEPTOR 4" -- -- -- -- -- --
JENSEN PRECAST 1,000 GALOON GREASE INTERCEPTOR WITH SAMPLE BOX
FINAL SIZE TO BE DETERMINED BY LOCAL BUILDING AUTHORITY
--
--
--
L 1 LAVATORY 1-1/4" 1-1/2" -- -- 1/2" 2 1.5
WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT SEE 8/P6.0,
4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER.
BRAIDED WATER LINES. FAUCET: FURNISHED BY OWNER-INSTALLED BY G.C. ELECTRONIC
HANDWASHING FAUCET, SLOAN BATTERY FAUCET. ADA COMPLIANT, 0.5 GPM AERATOR.
A.S. COMRADE/ MODEL: 0124.131
CRANE "HARWICH" / MODEL: 1412V
SLOAN FAUCETS SF-2350
S.O.V. ANSUL SHUT-OFF GATE VALVE
U UNION (LINE SIZE)
P.O.C. POINT OF CONNECTION
*. IF GEN POWER SOAK SINK USED THEN ADD A MIXING VALVE TO SINK ABOVE SUSPENDED CEILING.
WATER CALCULATION'S B
WH 1
WATER
HEATERS -- -- 1" 1" -- -- --
GAS FIRED TANKLESS WATER HEATER, 96% THERMAL EFF., 199,000 BTUH INPUT EA, 5.6 GPM
@67 F . RISE REC. RATE, 3" PVC FLUE & AIR INTAKE, ASME RTD TEMP.
& PRESS. REL. VALVE, ELECTRONIC IGNITION SYSTEM AND ELETRONIC CONTROLS.
NAVIEN NPE-240A
ALL WORK SHALL COMPLY WITH
THE 2012 INDIANA PLUMBING CODE.
9853 N MICHIGAN RD.
CARMEL, IN 46032
FDA-IN-01-21
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
ENDEAVOR - REMODEL
62 SEATS +/- / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
MISSOURI
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
CERTIFICATE OF AUTHORITY NO. 201808201274213
08/06/2021
P1.0
PLUMBING
SCHEDULES
AND NOTES
JTJ
DN
09/23/21
WASTE & VENT PLAN 1/4"=1'-0" A
WASTE & VENT PLAN NOTES CWATER HEATER CONDENSATE DETAIL E KEY NOTES B
A
B
C
D
E
F
12 11 10 9 8 7 6 5 4 3 2 1
YMF0121"MAX.HUB DRAIN/FLOOR SINK
NOT TO EXCEED 1" A.F.F.
3" PVC EXHAUST
DUCT
1/2" VINYL OR PVC CONDENSATE
DRAIN. MUST INCLUDE LOOP AIR
TRAP. 1/4"/ FT MIN. SLOPE
6"WATER HEATER
90° ELBOW WITH TAP PROVIDED BY
MANUFACTURER
WATER HEATER PLATFORM
TOP OF LOOP MUST BE BELOW
BOTTOM OF EXHAUST ELBOW.
NOT USED D
9
8
7
6
5
4
3
2
1A.
B.
C.
D.
E.
F.
G.
H.
NO ROOF PENETRATIONS PERMITTED WITHIN ROOF WATER PLY. REFER TO ROOF PLAN
FOR LOCATIONS.
REFER TO RISER DIAGRAM ON SHEET P5.0 FOR ALL WASTE AND VENT SIZES.
STORM WATER PIPING IS SIZED FOR A RAINFALL OF 4" PER HOUR. ADJUST ROOF DRAIN
(RD-1) SIZE AND STORM PIPE SIZES PER THE LOCAL RAINFALL REQUIREMENTS AND BY
THE AUTHORITY HAVING JURISDICTION. PIPE SHALL DISCHARGE OVER DRIVE-THRU
ROADWAY CURB OR AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION.
INSULATE ALL HORIZONTAL RUNS OF STORM DRAINAGE PIPING ABOVE THE CEILING OR
EXPOSED WITH 1" CLOSED CELLULAR INSULATION WITH VAPOR BARRIER JACKET THAT
CAN BE PAINTED.
4" SECONDARY DRAIN OUTLET SHALL EXTEND 2" BEYOND FINISHED WALL. SEE
ARCHITECTURAL DRAWING A4.0 FOR INSTALLATION PROCEDURE AND A4.1 FOR EXACT
LOCATION OF DRAIN OUTLET.
COORDINATE LOCATION OF STORM WATER PIPING ABOVE CEILING WITH ALL TRADES
PRIOR TO INSTALLATION.
SEE ARCHITECTURAL PLANS FOR DOWNSPOUT LOCATIONS
VERIFY WITH THE LOCAL BUILDING AUTHORITY THAT CONDENSATE DRAINAGE CAN BE
ROUTED TO THE MOP SINK.
UNDERGROUND SANITARY PIPE SHALL BE NO HUB CAST IRON PIPE FOR THE
FIRST 10 FEET FROM CONNECTION TO FLOOR SINK FS-2, OUTWARD.
REPLACE EXISTING FLOOR DRAIN WITH NEW HUB DRAIN. PROVIDE CONDENSATE
LINE AND DRAIN LINE FROM ICE MACHINE TO NEW HUB DRAIN, PROVIDE AIR GAP
PER LOCAL CODE. SEE P6.0
PROVIDE WASTE LINES FROM BEVERAGE UNIT TO HD / FS, PROVIDE AIR GAP PER
LOCAL CODE. SEE P6.0
ROUTE TO CONNECT TO EXISTING GREASE WASTE PIPING IN SPACE. VERIFY
EXACT SIZE, LOCATION, AND INVERT IN FIELD PRIOR TO WORK.
ROUTE TO CONNECT TO EXISTING VENT PIPING IN SPACE. VERIFY EXACT SIZE
AND LOCATION IN FIELD PRIOR TO WORK.
RUN DRAIN LINE FROM S/S DRINK MACHINE TO EXISTING HUB DRAIN BENEATH
D/T DRINK MACHINE. SEE DETAIL P6.0 AS REFERENCE FOR INDIRECT WASTE
PIPING. CONFIRM IF HUB DRAIN EXISTS, PROVIDE NEW FLOOR SINK AS
REQUIRED.
PIPE 3-COMPARTMENT SINK INDIRECTLY CONNECTED TO EXISTING HUB DRAIN
BELOW.
POINT OF CONNECTION TO EXISTING SANITARY PIPING IN SPACE. VERIFY EXACT
SIZE, LOCATION, AND INVERT IN FIELD PRIOR TO WORK.
ROUTE DRAIN FOR REVERSE OSMOSIS DISCHARGE TO FLOOR SINK. ENSURE
PROPER AIR GAP.
(E)1500 GALLON GREASE
INTERCEPTOR
(E)FD
(E)HUB
DRAIN
(E)HUB
DRAIN
(E)FD
(E)HUB
DRAIN
(E)SAN
S-284
2
3
S-513
(E)FD
(E)FD
FS 2
1
4
5
S-546
S-285
S-547
S-544
6
7
(E)HAND
SINK
(E)HAND
SINK
(E)MOP
SINK
5
8
4"
4" 4" 4" 4"
2"2" 2" 2"
2"
2"
2"
WC 1 WC 1
FD 1FD 1
L 1L 1
9
(E)HUB
DRAIN
FS 1
S 4
4
S 3
(E)FD
3"
3"
5
10 REMOVE AND CAP EXISTING FIXTURE. PATCH AND REPAIR TO MATCH EXISTING.
10 10
9853 N MICHIGAN RD.
CARMEL, IN 46032
FDA-IN-01-21
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
ENDEAVOR - REMODEL
62 SEATS +/- / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
MISSOURI
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
CERTIFICATE OF AUTHORITY NO. 201808201274213
08/06/2021
P2.0
WASTE AND
VENT PLAN
JTJ
DN
09/23/21
WATER & GAS PLAN 1/4"=1'-0" A
WATER & GAS PLAN NOTES CGAS LOAD SUMMARY D WATER FIXTURE SUMMARY E KEY NOTES B
A
B
C
D
E
F
12 11 10 9 8 7 6 5 4 3 2 1
TABLE TO CALCULATE WATER FIXTURE UNITS
PLUMING FIXTURE WATER FIXTURE
UNITS
NUMBER OF
FIXTURES
TOTAL WATER
FIXTURE UNITS
WATER CLOSET 4 2 8
LAVATORIES 2 2 4
HAND SINKS 2 2 4
MOP SINK 2 1 2
3-COMPARTMENT SINK 4 1 4
1-COMPARTMENT SINK 3 1 3
SODA SYSTEM 1 1 1
ICE MACHINE 1 2 2
TOTAL WATER FIXTURE UNITS 28.0
28 WFU (22GPM) WATER PIPE SIZE= 1-1/2"
WATER DISTRIBUTION PIPING IS SHOWN ABOVE FINISH CEILING. UNDER SLAB
DISTRIBUTION ALLOWED AT CONTRACTOR OPTION. COORDINATE ALL DETAILS.
NO ROOF PENETRATIONS PERMITTED WITHIN THE ROOF "WATER VALLEYS", REFER TO
ROOF PLAN FOR LOCATIONS.
FLUSH ALL WATER SUPPLY LINES OF ALL DEBRIS AND IMPURITIES PRIOR TO
CONNECTING TO WATER FILTERS.
PROVIDE REDUCED PRESSURE BACKFLOW TO SERVE CARBONATOR , DRAIN RELIEF TO
FLOOR SINK WITH AIR GAP.
PROVIDE A VENTED DOUBLE CHECK VALVE W/ATMOSPHERIC PORT FOR THE WATER
LINES SUPPLY LINES TO FOOD SERVICE EQUIPMENT (ASSE -1022.)
EQUIPMENT VENDER TO FOLLOW MANUFACTURE'S REQUIREMENTS TO INSTALL DOUBLE
CHECK VALVE ON EQUIPMENTS WHERE APPLICABLE.
A.
B.
C.
D.
E.
F.
1218 CFH =
1,218,000 BTUH
RETHERMALIZER
DOUBLE FRYER
TOTAL DEMAND
BASIS OF DESIGN
GAS DEMAND SCHEDULE
WH-1
RTU-2
RTU-1
110 CFH
110 CFH
398 CFH
350 CFH
250 CFH
NOTE:
COORDINATE GAS DEMAND REQUIREMENTS
AND PIPE SIZING WITH SITE-SPECIFIC RTU
DESIGN.
PIPE SIZE BASED ON 135' OF PIPE AND
7" W.C.
(2) PATIO HEATERS
(25 CFH / EACH)
NA
& WH-2
1/2"
S-546
S-285
S-547
S-544 3" SSOLENOID VALVE
BELOW CEILING 1-1/4"
1"
HW
C-077
C-107 P-315
S-600
S-375
S-513
S-284
(E)MOP
SINK
N-043
(E) SINK
(E) SINK
S-286
S-600
S-550 B-XX1
S-600
S-540
3/4"
EXISTING FIXTURE TO REMAIN.
REPLACE EXISTING FIXTURE WITH NEW SPECIFIED. RECONNECT ALL
EXISTING PLUMBING TO NEW FIXTURE.
ROUTE TO CONNECT TO EXISTING SUPPLY PIPING IN SPACE. VERIFY EXACT
SIZE AND LOCATIONS IN FIELD PRIOR TO WORK.
NEW TANKLESS WATER HEATER. ROUTE NEW HOT AND COLD WATER
CONNECTIONS TO EXISTING WATER HEATER AND ASSOCIATED SUPPLY
PIPING IN SPACE.
ROUTE NEW 1-1/4" GAS PIPING FROM NEW EQUIPMENT TO CONNECT TO
EXISTING COOKLINE GAS PIPING IN AREA. VERIFY EXACT SIZE AND
LOCATION IN FIELD PRIOR TO WORK.
EMERGENCY GAS SHUT-OFF VALVE TO BE LOCATED ABOVE CEILING.
ROUTE NEW 3/4" FILTERED WATER TO FIXTURES.
3/4 CW DOWN ALONG WALL TO WATER FILTER S-286. SEE DETAIL 1/P3.0.
BUNDLED SYRUP LINES TO BEVERAGE DISPENSERS S-284 & S-285 AND
FILTERED WATER LINES TO ICE MAKERS S-513 AND FROZEN BEVERAGE
DISPENSER S-739. SEE DRAWINGS A2.0 AND P4.0.
5
7
6
4
3
2
1
8
14
15
3" PVC COMBUSTION AIR AND VENT FOR WATER HEATER. SEE M2.1.
1/2" HOT WATER DOWN IN WALL TO RETHERMALIZER. PROVIDE SHUT-OFF
VALVE OUTSIDE OF WALL FOR CONNECTION TO RETHERMALIZER.
1/2" COLD WATER TO REVERSE OSMOSIS FILTER P-315 AND 1/2" FILTER
WATER FROM REVERSE OSMOSIS FILTER. PROVIDE SHUT-OFF VALVE ON
CW PIPE PRIOR TO CONNECTION TO FILTER. SEE DETAIL 9 / P4.0.
1/2" COLD WATER. CONNECT TO WATER FILTER FOR BUNN POD BREWER
S-547. PROVIDE SHUT-OFF VALVE PRIOR TO CONNECTION TO THE WATER
FILTER.
RUN GAS PIPE 18" A.F.F. WITH DIRT LEGS FOR GAS HOSE KITS TO COOKING
EQUIPMENT. HARD GAS LINE BEHIND COOKING EQUIPMENT SHALL NOT
BE MORE THAN 6" MAX. FROM THE WALL SURFACE.
GAS DIRT LEG W/ GAS COCK TO COOKING EQUIPMENT. PROVIDE FLEXIBLE
GAS HOSE KIT FOR CONNECTION TO COOKING EQUIPMENT. SEE 5/P5.0
FOR SIZES.
EXISTING GREASE RECOVERY SYSTEM AND ALL ASSOCIATED PLUMBING TO
BE REMOVED. VERIFY EXACT LOCATION IN FIELD PRIOR TO WORK.
12
11
10
9
13
1
1
1
2
3
3
4
5
6
73
3
8
8
8
8 S-739
9
10
3
11
12
13
14FILTERED WATER ISOMETRIC N.T.S. 1
S-513
S-513
*
*
F1
F2
F1
S-285
S-284
F2
*
*
F3
F3
F1
S-546
S-739*
15
S-286
3/4" COLD
WATER
FILTERED WATER SUPPLIED VIA SYRUP BUNDLE. REFER TO 11/P6.0. SEE
SCOPE OF WORK FOR RESPONSIBILITIES.*
FILTERED EQUIPMENT AND LINES:
- WATER FILTER
FILTERED LINE (COLD WATER)
- ICE MAKER - ABOVE SELF-SERVE BEVERAGE DISPENSER *
- ICE MAKER - ABOVE DRIVE-THRU BEVERAGE DISPENSER *
- DRIVE-THRU BEVERAGE DISPENSER *
- SELF-SERVE BEVERAGE DISPENSER *
- ICED TEA BREWER
- FROZEN BEVERAGE DISPENSER *
S-286
S-284
S-285
S-513
S-513
S-546
S-739
S 4
S 3
WC 1 WC 1L 1L 1
RO 1
WH 1
3/4"
1/2"1/2"
(E)WH
9853 N MICHIGAN RD.
CARMEL, IN 46032
FDA-IN-01-21
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
ENDEAVOR - REMODEL
62 SEATS +/- / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
MISSOURI
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
CERTIFICATE OF AUTHORITY NO. 201808201274213
08/06/2021
P3.0
WATER AND
GAS PLAN
JTJ
DN
09/23/21
DRINK SYSTEM SCHEMATIC N.T.S. 11
DRINK SYSTEM SCHEMATIC DETAIL N.T.S. 16 TWYMF0021/2" TEMPERED WATER TO
LAVATORIES
SHUT-OFF VALVE (TYP)
CHECK VALVE (TYP)
DOMESTIC CW
DOMESTIC HW
THERMOMETER
1/2" LINE
1MV
TEMPERING VALVE N.T.S. 17 REVERSE OSMOSIS SYSTEM N.T.S. 9 RTU CONDENSATE N.T.S. 13
WATER FILTRATION SCHEMATIC N.T.S. 6 YMF003WALL
LAVATORY
FLOOR MOUNT UPRIGHT SUPPORT
4x4 WELDED BASE PLATE W/ (4) 1/2"
HILTI KWIK BOLT II OR EQUAL
FINISH FLOOR
WATER FILTER SYSTEM N.T.S. 4LAVATORY SUPPORT N.T.S. 8
TANKLESS WATER HEATERS N.T.S. 2
WATER LINE
CO2 LINE
TPS024FROZEN
BEVERAGE
DISPENSER
3/8" FILTERED
WATER LINE
3/8" x 1/4" SHUT
OFF VALVE
3/8" CO2 LINE
FILTERED WATER LINE
TO D/T DRINK
DISPENSER
CO2 LINE TO D/T DRINK
DISPENSER
TEE OFF FROM D/T
DRINK DISPENSER CO2
LINE AND RUN TO FBD
TEE OFF FROM D/T
DRINK DISPENSER
FILTERED WATER LINE
AND RUN TO FBD
FILTERED WATER
AND CO2 LINES VIA
SYRUP BUNDLE
SEE 11/P6.0 FOR PLUMBING
CONNECTIONS OF ADDITIONAL
EQUIPMENT TO FILTER SYSTEM.
IF TUBES ARE EXPOSED, PROVIDE
STAINLESS STEEL WALL COVER
1.
2.
3.
4.
5.
6.
7.
GENERAL NOTES:
OVERALL DIMENSIONS 21" WIDE x 12" DEEP x 48 1/2" HIGH
SEE SCOPE OF WORK FOR ADDITIONAL INFORMATION.
INSTALLATION MUST COMPLY WITH STATE OR LOCAL PLUMBING
CODES.
THE UNIT MUST BE PROTECTED AGAINST FREEZING.
USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL
THREADED PARTS; NO PIPE DOPE.
DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR
WHERE TEMPERATURE EXCEEDS 100 F.
SEE SHT. A2.0 FOR LOCATION.
WB2-M3-22-003
WATER BOOST MODULAR FILTRATION (WBMF) SYSTEM
FILTER LINE F2 SUPPLIES
BUNDLED TUBE BY PEPSI
1. ICE MACHINES
FILTER LINE F1 SUPPLIES
BUNDLED TUBE BY PEPSI
1. DRIVE THRU DRINK STATION
2. SELF SERVE DRINK STATION
ALL WORK THIS DETAIL PER DETAILS 6, 11 & 12/P6.0
3/4" COLD WATER INLET TO 1/2" COPPER LINE AND FITTINGS AT FILTER.
3/4" OUTLET W/ INTEGRAL BACKFLOW PREVENTER, EQUAL TO WATTS
REGULATOR CO. SERIES 007 AND SERVICE BALL VALVE.
2
1
2
KEY NOTES:
1
F2 F1
TPW001WASTE WATER INDIRECT TO
FLOOR SINK/HUB DRAIN
TEST
PORT PRESSURE
GAUGE
STORAGE
TANK
SHUT-OFF
VALVE
PRESSURE
REGULATOR
GATE
VALVE
WATER FROM
WATER
SOFTENER -
PRIOR TO
WATER HTR.FILTERFILTERYMR008WATER TO
CHEESE MELTER
LINE AFTER PRESSURE REGULATOR
SHALL BE 3/8" PLASTIC LINE
CONNECTING AT THE TOP OF THE
PRODUCTION LINE UTILITY CHASE.
PREFILTER
CARTRIDGE R.O.
MEMBRANE
SEE WASTE PLAN FOR
CONDENSATE LINE BELOW ROOF
REMOVABLE THREADED CAP FOR
CLEAN-OUT & WINTER DRAINING
CONNECTION TO DRAIN PAN
FULL SIZE VENT TO ATMOSPHERE
RETURN CONDENSATE DRAIN LINE
THROUGH CURB OR THROUGH THE
SINGLE MEMBRANE ROOF W/ MFR.
APPROVED BOOT FLASHING.
CONNECT TO MAIN ABOVE CEILING
AND TERMINATE 2" ABOVE RIM OF
MOP SINK. INSULATE ALL PIPING
BEYOND THIS PENETRATION
EQUIPMENT CURB
6" 4"3"CD
RTU
DRINK MACH. BUNDLE CONFIG. NTS 12
ICE MAKER
CARB PUMP
DRINKING
Co2
SYRUP BUNDLEWATER & Co2 BUNDLE
9 FLAVORS & 4
LINES FOR
FUTURE
APPROX.
41
2" DIA.
APPROX.
71
2" DIA TPS030TPS030DRIVE THRU
DRINK
COUNTER
DINING ROOM
FLOOR SINK
DRINK
DISPENSER
ROOF
CEILING
BAG N BOX RACK
1/2 I.D. LINE
WATER
REGULATOR -
60PSI
BULK CO2 TANK
REMOTE
ROOFTOP
CONDENSER
REMOTE
ROOFTOP
CONDENSER OVERALL FILTER DIMENSIONS:
21" WIDE x 12" DEEP x 48 1/2" HIGH
SEE DETAIL SCOPE OF WORK FOR SCOPE
DEFINITIONS.
ROUGH-INS SHALL BE PROVIDED BY THE
CONTRACTOR.
INSTALLATION MUST COMPLY WITH ANY
STATE OR LOCAL PLUMBING CODES.
THE FILTER MUST BE PROTECTED AGAINST
FREEZING.
USE ONLY TEFLON (HIGH-LOW
TEMPERATURE) TAPE TO SEAL THREADED
PARTS; NO PIPE DOPE.
DO NOT INSTALL WHERE LINE PRESSURE
EXCEEDS 125 PSI OR WHERE
TEMPERATURE EXCEEDS 100 F.
SEE THE EQUIPMENT PLAN FOR LOCATION.
SEE DETAIL 12 THIS SHEET FOR BUNDLE
DETAILS
"Y" FOR ICE MACHINES SUPPLY LINES
SHALL BE INSTALLED @ FILTER OUTLET.
BACKFLOW PREVENTERS FOR FILTER
ASSEMBLY ARE PROVIDED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
CO2
SECONDARY
REGULATOR
90-100 PSI
GENERAL NOTES:
NOTE INSTALL ELECTRICAL, WATER, AND DRAIN IN
ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL
CODES.
EQUIPMENT RATING:
ED250 DISPENSER - 115V, 3.5 AMPS
ED300 DISPENSER - 115V, 4.0 AMPS
CARBONATOR - 115V, 60 Hz, 7.0 AMPS
BOOSTER ASSEMBLY - 115V. 60 Hz, 6.5 AMPS
SYRUP
WATER FILTER
THERE ARE TWO SELF-SERVE DRINK/ICE
SYSTEMS WHICH SHARE A COMMON FLOOR
SINK WITH THE D/T DRINK/ICE SYSTEM.
SYRUP SYRUP
SYRUP SYRUP SYRUP
SYRUPSYRUP SYRUP
SYRUP SYRUP SYRUP
I
EC
CITY
WATER
SUPPLY
3/8"
SHUT-OFF
VALVE
REFRIGERANT
LINES
REFRIGERANT
LINES
3/8" Co2 LINE
KEY NOTES:
1
BACK ROOM
CARBONATOR
MOTOR
DRINK
COUNTER
ICE TEA
BREWER
ICE MACHINE
FRUITISTA
MACHINE
3/8" FILTERED WATER LINE TO DINING & DRIVE THRU
A. WATER LINE TO ICE MACHINE
B. WATERLINE TO WATER DISPENSER VALVE
C. WATERLINE TO CARBONATOR
4
14 - 3/8" SYRUP
LINE BUNDLE
2
1/2 X 3/8 X 3/8 "Y"3
3/8" SHUT OFF VALVES
BARB FITTINGS. TYP @
ALL"Y"s
9
STAINLESS CHASE
SURFACE MOUNTED FROM
CEILING TO TOP OF ICE
MACHINE
6
PRE-SET Co2 REGULATOR7
SURFACE MOUNTED S.S.
CHASE; ONE FOR EACH
BUNDLE. SEE DTL. 19/A6.4
8
BUNDLED TUBING CEILING
PENETRATION. SEE DETAIL 18/A6.4
5
DRINK SYSTEM BUNDLED
TUBING. SEE DETAIL
12/P6.0
10
DRINK
DISPENSER
ICE MACHINE
OPENING IN WALL FOR
DINING ROOM DRINK
DRAIN LINE. SEE
11/A6.4
2 4
3/8" FILTERED
WATERLINE - ICE TEA,
FRUITISTA, DRINK
MACHINES & ICE
MACHINES
11
10
5 58 8
ICEMAKER
DRAINDISPENSER DRAIN
11
4C
2
6 6
ELECTRICAL FOR DRINK
SYSTEM. SEE SHEET E3.0
13
13
1
7
3/8" LINE FOR
PRESSURIZE FILTERED
WATER
12
12
7
12
CARBONATOR
MOTOR
13
1
TYPICAL FOR 6 LINES
BUNDLES OF 6 WATER LINES
AND 1 Co2 LINE
3
9
3
9
1
1
4A
4B
4C
2
1
4A
4B
9 39
3
SYRUP LINE "T" SPLICES SHALL BE DONE BELOW THE D/T DRINK
TABLE. ONCE SYRUP LINES HAVE BEEN SPLICE COMBINE 14 SYRUP
LINES, 3 WATER LINES AND 1 Co2 LINE AND RUN TRHOUGH IN-WALL
OPENING TO THE SELF SERVE DRINK STATION AND CONNECT LINES
AS SHOWN.
WATER HEATER SCHEDULE N.T.S. 7
QTY MODEL #
2 NPE-240A
DESCRIPTION
NAVIEN TANKLESS WATER HEATERS
1 MFK7 MANIFOLD KIT *
1 DET12 EXPANSION TANK
1 HAL ALARM LIGHT W/ INSTALLATION INSTRUCTIONS
1 PK100 STAND
* THE FOLLOWING ARE INCLUDED IN THE MANIFOLD KIT:
QTY DESCRIPTION QTY DESCRIPTION1 3/4" BLK GAS COCK 1 3" PVC 90°
1 3/4" BLK UNION 1 1/2" PVC STREET 90°
1 3/4" BLK TEE 1 1/2" PVC 90° ELBOW
1 3/4" BLK CAP
3 3/4" x 2 1/2" BLK NIPPLE
1 3/4" x 4 BLK NIPPLE
1 3/4" THD BALL VALVE
2 1 1/2" FX UNION
6 1 1/2" CXC 90
1 1 1/2" CXC TEE
2 1 1/2" BALL VALVES CXC
1 1 1/2" CHECK VALVES CXC
1 1 1/2" GALV ST 90
1 1 1/2" CX ST 901 HPT-507 1/2" P-TRAP
1 1/2" P4 SMA
1 1 1/2" x 1 1/2" x 1/2" TEE COPPER
1 DIAL THERMOMETER
1 1/2" COPPER FEMALE FITTING ADAPTER
PREP LINES
CHEESE MELTER
R.O. SYSTEMDRY PRODUCTION LINE
SUPPLY MAIN FROM METER
C254
P452
N043
C107
B-223
Nxxx
ICED TEA BREWER
CARBONATOR 2
CARBONATOR 1
DRIVE-THRU DRINK
SYSTEM
SELF-SERVE DRINK
SYSTEM
VALVE MANIFOLD
SELF-SERVE
ICE MACHINE
DRIVE-THRU
ICE MACHINE
S570
S570
S284
S285
S513
S513
SEE 11/P6.0 FOR PLUMBING
CONNECTIONS OF ADDITIONAL
EQUIPMENT TO FILTER SYSTEM.
SURFLO DRINK/
ICE FILTRATION S286
S546
BUNN HOT WATER
IN-LINE POLY
FILTER
FROZEN BEVERAGE
DISPENSER
S739
TPS031UTILITY - GENERAL KITCHEN
(HOT)
POWER SOAK @ 3 COMP. SINK
FLOW ARROW
POINT OF CONNECTION (PEPSI)
POINT OF CONNECTION (GC)
UTILITY - TOILET ROOMS / GENERAL KITCHEN (COLD)
LEGEND
RETHERMALIZER
KITCHEN EQUIPMENT #
(SHEET A2.0)
SYSTEM
WATER
HEATER
S547BUNN POD BREWER
EXHAUST
6'
1'-2'
INTAKE
BALL VALVE
UNION
PIPE TO
HUB DRAIN
ROOF
2' MIN
EXHAUST
6'
1'-2'
INTAKE
PRESSURE
RELIEF
VALVE
EXIST.
WATER
HOT WATER SUPPLY LINE
GAS SUPPLY LINE
ROOF
2' MIN
PRIMARY SUB 1
PROVIDE
RAIN CAP
HEATER
NAVIEN
WATER
HEATER
COLD WATER
SUPPLY LINE
AQUAREX WK1
WATER CONDTIONER
OR EQUAL
110V-11W
9853 N MICHIGAN RD.
CARMEL, IN 46032
FDA-IN-01-21
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
ENDEAVOR - REMODEL
62 SEATS +/- / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
MISSOURI
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
CERTIFICATE OF AUTHORITY NO. 201808201274213
08/06/2021
P4.0
PLUMBING
DETAILS
JTJ
DN
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21
09/23/21