Loading...
HomeMy WebLinkAbout0-Taco Bell - 08.06.2021 - T1.0 Title SheetX X AXXXX X X X AXXX X AXXX NAME Taco Bell ENDEAVOR REMODEL 9853 NORTH MICHIGAN ROAD CARMEL, IN 46032 TITLE SHEET T1.0 DEVELOPER / TENANT NORTH MICHIGAN HOLDINGS, LLC 7162 READING ROAD, SUITE 730 CINCINNATI, OH 45237 CONTACT: MARK D. AYER / MIKE NEIMIEC PHONE: 513.608.3619 / 773.793.0703 PREVIOUS BURGER KING OPERATED BUILDING TO BE REMODELED INTO TACO BELL RESTAURANT USE. SITE WORK TO INCLUDE NEW DRIVE-THRU LANE EQUIPMENT. INTERIOR TO HAVE FULL REMODEL TO RESTAURANT USE. EXTERIOR TO HAVE NEW SIGNAGE AND AWNING INSTALLED. BUILDING AREA AND OCCUPANT LOAD: TYPE AREA FACTOR OCCUPANTS PUBLIC - DINING ROOM 932 N.S.F. 62 SEATS (1004.4) 62 PUBLIC - CUSTOMER AREA 118 N.S.F. 1:5 SF 24 KITCHEN - COMMERCIAL 565 G.S.F. 1:200 SF 3 STORAGE 475 G.S.F. 1:300 SF 2 OFFICE 40 G.S.F. 1:100 SF 1 PASSAGE 88 N.S.F. 0 0 VESTIBULE 117 N.S.F. 0 0 COOLER / FREEZER 224 G.S.F. 0 0 RESTROOMS 133 G.S.F. 0 0 MISC. 319 G.S.F. 0 0 TOTAL 3,011 G.S.F. 92 DESCRIPTION OF PROJECT: LEGAL JURISDICTION: CITY OF CARMEL BUILDING CODE: 2014 INDIANA BUILDING CODE (2012 IBC) BUILDING AREA: 3,011 S.F. SEATING: 62 OCCUPANCY: A-2 TYPE CONSTRUCTION: V-B 2012 INDIANA PLUMBING CODE (2006 IPC) 2014 INDIANA MECHANICAL CODE (2012 IMC) 2009 INDIANA ELECTRICAL CODE (NFPA 70-2008) 2014 INDIANA FIRE CODE (2012 IFC) 2009 ICC A117.1 ACCESSIBILITY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1, 2007) REFER TO CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS ROOM NAME SHEET NUMBER ELEVATION NUMBER CEILING HEIGHT SECTION NUMBER SECTION SHEET DETAIL NUMBER DETAIL SHEET REVISION NUMBER BLDG. HEIGHT REFERENCE POINT ELEV. LETTER ELEV. SHEET DOOR NUMBER WINDOW NUMBER / DECOR ITEM NUMBER EXTERIOR WALL FINISH NUMBER KEY NOTE NUMBER EQUIPMENT NUMBER ROOM FINISH NUMBER 1. GENERAL CONTRACTOR (G.C.) TO PROVIDE AND PAY FOR ALL SPECIAL INSPECTIONS REQUIRED. 2. ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE INDIANA STATE BUILDING CODE, INTERNATIONAL BUILDING CODE, AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY OF CARMEL, IN. 3. ALL ELEMENTS NECESSARY TO CREATE A LEGALLY OCCUPIABLE BUILDING SHALL BE PROVIDED. 4. G.C. TO PROVIDE AS-BUILT DOCUMENTS TO TENANT PRIOR TO PROJECT CLOSE OUT. 5. ALL MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS ARE RESPONSIBLE FOR ALL MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PER CODE. 6. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. 7. DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO FABRICATION OF ANY ITEM. FAILURE TO ADHERE TO THIS PROCEDURE SHALL PLACE FULL RESPONSIBILITY FOR ANY ERRORS DIRECTLY UPON THE CONTRACTOR. 8. GENERAL CONTRACTOR AND ALL APPLICABLE SUBCONTRACTORS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ANY EXISTING STRUCTURES, SITE CONDITIONS, ETC. FOUND ON SITE AND TO COORDINATE WITH ALL LOCAL AUTHORITIES HAVING JURISDICTION FOR THE PROPER REMOVAL AND DISPOSAL OF EXISTING STRUCTURES, SITE CONDITIONS, ETC. SEE ALSO CIVIL DRAWINGS FOR GEOTECHNICAL REPORT. 9. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. 10. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY FLYNN RESTAURANT GROUP, IN WRITING, PRIOR TO INSTALLATION. 11. G.C. IS RESPONSIBLE FOR SUBMITTAL, PAYING FEES AND OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, HOOD ANSUL, OR OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT, ETC. G.C. REQUIRED TO PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. 12. G.C. SHALL PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME OF CONSTRUCTION. 13. IT IS THE G.C.'S RESPONSIBILITY TO CONFIRM THE AVAILABLE "RESIDUAL" WATER PRESSURE, PRIOR TO THE START OF ANY WORK, AND NOTIFY THE TENANT IF THE AVAILABLE PRESSURE IS NOT ADEQUATE TO SERVICE THE ANSUL SYSTEM OR OTHER PRESSURE SENSITIVE EQUIPMENT. 14. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AS REQUIRED TO SAFELY INSTALL NEW WORK. THIS WORK SHALL BE THE FULL RESPONSIBILITY OF THE CONTRACTOR AND NO ACT, DIRECTIONS OR REVIEW OF ANY SYSTEM OR METHOD BY THE ARCHITECT SHALL CHANGE OR AFFECT THE CONTRACTOR'S RESPONSIBILITY IN THIS MATTER. SEE ALSO STRUCTURAL DRAWINGS. 15. G.C. SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS OTHERWISE NOTED. 16. SCOPE OF WORK AND SPECIFICATIONS DOCUMENTS ARE INCLUDED AS CONTRACT DOCUMENTS FOR THIS PROJECT. IF THEY HAVE NOT BEEN PROVIDED TO YOU FOR THIS PROJECT, PLEASE ASK TENANT FOR A COPY OF APPLICABLE SECTION. 17. G.C. SHALL PROVIDE WARRANTY DOCUMENTATION FOR ANY/ALL NEW WORK PERFORMED AT THE CONCLUSION OF THE PROJECT. 18. DRAWINGS ARE BASED ON EXISTING BUILDING SURVEY DOCUMENTS RECEIVED 4/20/2021 PREPARED BY IFTI PROVISION SOLUTIONS. ARCHITECT NOT LIABLE FOR THE ACCURACY OF EXISTING BUILDING CONDITIONS. FIRE SPRINKLER: NOT REQUIRED PER 903.2.1.2 NUMBER OF EXITS REQUIRED - DINING ROOM (1015.1): 2 NUMBER OF PUBLIC ACCESSIBLE ENTRANCES / EXITS (1007.1): 2 REQUIRED ASSEMBLY AISLE WIDTH (1028.9.1 (4) (EX.1)): 36" REQUIRED AISLE ACCESS WAY (1028.10.1.1 - LESS THAN 12 FEET LENGTH): 12" PLUMBING FIXTURE REQUIREMENTS PER TABLE 2902.1 TOTAL OCCUPANTS = 92 (46 WOMEN / 46 MEN) CLASSIFICATION: ASSEMBLY (A-2) REQUIRED PROVIDED WOMEN MEN 0.61 0.61 0.23 0.23 1 1 WATER CLOSETS (1:75) LAVATORIES (1:200) SERVICE SINK DRINKING FOUNTAIN NOT REQUIRED: TABLE 2902.1 (h) ARCHITECT FINN DANIELS ARCHITECTS 2145 FORD PARKWAY, SUITE 301 ST. PAUL, MN 55116 CONTACT: GREG DAHLING PHONE: 651.888.6884 PERMIT / BID08.06.2021ISSUED FOR CITY PLANNING REVIEW ISSUED FOR BID / PERMIT / CONSTRUCTION ISSUED FOR PRELIMINARY REVIEW ISSUED FOR CONSTRUCTION WITH REVISED INFO ISSUED FOR BID X'-X" XX-X DIRECTION OF DETAIL X AXXX X X X X X-XXX X'-XX" ELEV. PROJECT GENERAL NOTES VICINITY MAP GENERAL DRAWING SYMBOLS PROJECT DIRECTORY SHEET INDEX PROJECT/CODE SUMMARY T1.0 TITLE SHEET GENERAL PROJECT INFORMATION ARCHITECTURAL A1.1 DOOR & WINDOW ELEVATIONS & SCHEDULES A1.0 FLOOR PLAN MECH. / ELEC. ENGINEER CASE ENGINEERING, INC. 796 MERUS COURT ST. LOUIS, MO 63026 CONTACT: NICK BASLER (MECH) PHONE: 636.349.1600 N A2.1 EQUIPMENT SCHEDULE A4.0 EXTERIOR ELEVATIONS A4.1 EXTERIOR ELEVATIONS A6.0 CONSTRUCTION DETAILS - ROOF A2.0 SEATING AND EQUIPMENT PLAN A3.0 ROOF PLAN A6.1 CONSTRUCTION DETAILS - DOORS / WINDOWS A6.3 FINISH DETAILS A6.4 CEILING DETAILS A7.0 FINISH FLOOR PLAN A7.1 REFLECTED CEILING PLAN MECHANICAL / PLUMBING / ELECTRICAL D1.0 DEMOLITION FLOOR PLAN A8.0 INTERIOR ELEVATIONS - DINING ROOM A8.1 ENLARGED PLANS AND ELEVATIONS A7.2 FINISH SCHEDULE 9853 N MICHIGAN RD. CARMEL, IN 46032 TB21-10 GGD 08.06.2021PERMIT / BID: ISSUES AND REVISIONS: CHECKED BY: DRAWN BY: PROJECT NO.: KDI ENDEAVOR - REMODEL 62 SEATS / 3,011 +/- S.F. TACO BELL, CARMEL, IN A R C H I T E C T S 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116 651.690.5525 www.finn-daniels.com Rebecca L. Olson, AIA #AR11500059 IAN AI ND REGISTER E D REBECCAL.O L SONSTATE OF ARCHITEC T NO. AR11500059 WOMEN MEN 1 1 1 1 A8.2 INTERIOR ELEVATIONS - KITCHEN A8.3 INTERIOR ELEVATIONS - KITCHEN M1.0 MECHANICAL SCHEDULES AND NOTES M2.1 MECHANICAL ROOF PLAN M3.0 MECHANICAL DETAILS P1.0 PLUMBING SCHEDULES AND NOTES P2.0 WASTE AND VENT PLAN P3.0 WATER AND GAS PLAN P4.0 PLUMBING DETAILS E2.0 RISER DIAGRAM AND LEGEND E2.1 PANEL SCHEDULES AND LOAD SUMMARY E2.2 ELECTRICAL SCHEDULES E3.0 FLOOR POWER PLAN E3.1 ENLARGED POWER PLAN AND DETAILS E3.2 ROOF POWER PLAN E4.0 LIGHTING PLAN AND SCHEDULE E5.0 COMMUNICATIONS PLAN E6.0 ELECTRICAL DETAILS E6.1 ELECTRICAL DETAILS E7.0 ELECTRICAL DETAILS T2.0 LIFE SAFETY PLAN SITE A0.0 SITE PLAN A0.1 SITE DETAILS A0.2 SITE DETAILS D1.1 DEMOLITION REFLECTED CEILING PLAN M2.0 DUCT AND DIFFUSER PLAN 09/23/21