HomeMy WebLinkAbout0-Taco Bell - 08.06.2021 - T2.0 Fire-Life Safety PlanW/H
2X4
2X42X4 2X4 2X4 2X62X62X62X42X42X4
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
HAND DRYERXLERATOR XL-C9 1/2"W x 6 11/16"D x 1211/16"H
VESTIBULE #1
FREEZERCOOLER
WASHING
PREP
TB COOK
DRY STORAGE
DRIVE-THRU
KITCHEN
UTILITY
DINING
CUSTOMER
WOMEN'S MEN'S
SERVING
VESTIBULE #2
OFFICE
FIRE AND LIFE
SAFEY PLAN
T2.0
9853 N MICHIGAN RD.
CARMEL, IN 46032
TB21-10
GGD
08.06.2021PERMIT / BID:
ISSUES AND REVISIONS:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
KDI
ENDEAVOR - REMODEL
62 SEATS / 3,011 +/- S.F.
TACO BELL, CARMEL, IN
A R C H I T E C T S
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116
651.690.5525
www.finn-daniels.com
Rebecca L. Olson, AIA #AR11500059
IAN AI
ND
REGISTER
E
D REBECCAL.O
L
SONSTATE OF
ARCHITEC T
NO. AR11500059
FIRE AND LIFE SAFETY PLAN1/4"=1'-0" 1
CODE LEGEND
KEY NOTES
1 G.C. TO PROVIDE AND INSTALL OCCUPANT LOAD SIGN ON WALL AT
9'-6" A.F.F. SIGN TO READ "MAXIMUM OCCUPANCY 92 PERSONS".
FINAL COORDINATE DETAILS AND LOCATION WITH LOCAL
AUTHORITY HAVING JURISDICTION PRIOR TO INSTALL.
PROPOSED LOCATION OF "K" CLASS FIRE EXTINGUISHER.
COORDINATE FINAL LOCATION WITH LOCAL AUTHORITY HAVING
JURISDICTION PRIOR TO INSTALL.
PROPOSED LOCATION OF "ABC" CLASS FIRE EXTINGUISHER.
COORDINATE FINAL LOCATION WITH LOCAL AUTHORITY HAVING
JURISDICTION PRIOR TO INSTALL.
2
3
NOT USED
N
EXIT
FE PROPOSED FIRE EXTINGUISHER
LOCATIONS (FINAL COORDINATE
QUANTITY AND LOCATIONS WITH LOCAL
AUTHORITY HAVING JURISDICTION
PRIOR TO INSTALL.)
EXIT ACCESS TRAVEL DISTANCE
(LENGTH AS NOTED ON PLAN)
3
FE
FE
FE
∂COMMON PATH OF
EGRESS TRAVEL = 4 FT.
∂EXIT ACCESS TRAVEL
DISTANCE = 60 FT. (DINING EXIT)
AND 57 FT. (SERVICE EXIT)
EXIT ACCESS TRAVEL
DISTANCE = 35 FT.
EXIT ACCESS TRAVEL
DISTANCE = 37 FT.
EXIT ACCESS TRAVEL
DISTANCE = 51 FT.
3
2
1
(2) OCCUPANT
(3) OCCUPANT
(1) OCCUPANT
(31) OCCUPANT
(56) OCCUPANT
09/23/21