Loading...
HomeMy WebLinkAboutGN010.0GENERAL NOTES: THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. BUILDING PERFORMANCE:BUILDING PERFORMANCE: HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF REGIONAL AND LOCAL CODES. SEE CALCULATIONS. PORCHES, DECKS, FOUNDATION, FIREPLACE ENCLOSURES, AND GARAGE AREAS NOT INCLUDED IN LIVING AREA. ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR. ALL PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK OR FOAM. DISCLAIMER: To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all dimensions and enclosed drawing. Francium LLC is not liable for errors once construction has begun. While every effort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. DOOR/WINDOW NOTES: Every bedroom shall be provided with an egress window with finish sill height not greater than 44" above the finish floor height and shall have a minimum accessible area of 5.7 sq. ft. Egress windows shall not have an accessible area less than 20" wide or 24" high. All walk-thru doors shall be solid core Interior doors shall be painted or stained. Exterior exit doors will be 36" min. net clear doorway shall be 32" min. Door shall be accessible from inside without the use of a key or any special knowledge or effort. Glazing in doors shall be dual pane safety glass with min. u-value of 0.60. GRADING NOTES: 1CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UTILITIES. 2 PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. 3 FINAL GRADE TO CONVEY SURFACE DRAINAGE TOWARD ROCK CHANNELS AND DISPERSION TRENCHES. 4 AREAS TO BE FILLED SHALL BE CLEARED, GRUBBED TO REMOVE TREES, VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL AND STRIPPED OF TOPSOIL. 5 PLACE FILL SLOPES WITH A GRADIENT STEEPER THAT 3:1 IN LIFTS NOT TO EXCEED 8 INCHES, AND MAKE SURE EACH LIFT IS PROPERLY COMPACTED. >1-HOUR FIRE-RATING FRAMING NOTES: 1PROVIDE FIRE BLOCKING, DRAFT STOPS AND FIRE STOPS AS PER I.R.C. SEC R302.1(1) 2 ALL VERTICAL ANNULAR OPENINGS CREATED BY MECHANICAL ELEMENTS MUST BE SEALED BY ASTM E 814-RATED FIRE- BARRIER SEALANT. 3 HORIZONTAL ANNULAR OPENINGS MUST BE SEALED BY AN ASTM E 814-RATED SEALANT AS PER EVERY SIX (6) FEET BETWEEN OPENINGS. 4 MID-SPAN BLOCKING IN THE FORM OF STANDARD-GRADE LUMBER TO BE USED BETWEEN ALL EXTERIOR AND INTERIOR STUDS, EVERY TEN (10) VERTICAL FEET BETWEEN FLOOR PLATFORMS. 5 TYPE-X (1/2" or 5/8") FIRE-RATED DRYWALL SHALL BE USED ON ALL EXTERIOR-FACING WALLS.FRANCIUM LLC4242 N College AveIndianapolis, IN 46205-1930email: info@fr-87.comphone: 317.513.5790Date: Thursday, August 26, 2021File: 8-circle-DR-20210729Revised:8 Circle DRgarage addition / siding revisionCOPYRIGHT Francium LLC. This drawing is the property of Francium LLC and cannot be copied or reproduced without the permission of Francium. All revisions shall be documented and sent to Francium for review before being reissued for PERMITTING or CONSTRUCTION. AA0.0 Begin PAGE 1 of 10 BUILDING & DESIGN SPECIFICATION frBegin(0) 09/27/21