HomeMy WebLinkAbout42300016 - GR3 87 - Truss DetailsDE
DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under
my direct supervision and control based on the parameters provided by Stark Truss Inc.
Job: 2107035-12T
29 truss design(s)
86641-W1
09/10/2021
Samuel A. Greenberg, P.E.
Indiana Reg. #19700485
Indiana Residential Building Code 2020 based on IRC 2018 with Indiana specific amendments.
675 IAC 14-4.4-81 Section R802.10.1; truss design drawings, R802.10.1; truss design drawings shall
be provided to the building official as required by the General Administrative Rules (675 IAC 12) for
Class 1 structures or by local ordinance for Class 2 structures.
Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural
gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length
is the distance from the top chord to bottom chord.
The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown. The suitability and use of this
component for any particular building is the responsibility of the building designer, per
ANSI/TPI 1-2014 Chapter 2.
Warning !—Verify design parameters and read notes before use.
These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of
design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is
for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,
quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss
Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate
Institute, 583 D’Onofrio Drive, Madison, WI 53719
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=4x6
=4x8
=8x8
=3x5 =4x4
=8x8
=3x5
=8x8
=4x8
=4x6
10
13 14 9 15 16 178 18 19 7 20 21
6
51
421211
3
T1 T1
W1 W1
B1 B1
W3 W4
W5
W4 W3
W2 W2
4-9-4
4-9-4
4-5-12
9-3-0
4-5-12
13-8-12
4-9-4
18-6-0
4-6-5
4-6-5
4-6-5
18-6-0
4-8-11
13-11-11
4-8-11
9-3-01-2-67-4-6Scale = 1:36.6
Plate Offsets (X, Y):[4:0-0-0,0-0-0], [6:Edge,0-2-0], [7:0-3-8,0-4-4], [8:0-4-0,0-4-8], [9:0-3-8,0-4-4]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.24 Vert(LL)-0.05 8-9 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.63 Vert(CT)-0.10 8-9 >999 180
TCDL 10.0 Rep Stress Incr NO WB 0.69 Horz(CT)0.02 6 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 198 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud *Except* W1:2x6 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)6=3422/0-6-0, (min. 0-2-14), 10=3624/0-6-0, (min. 0-3-1)
Max Horiz 10=-193 (LC 10)
Max Uplift 6=-516 (LC 13), 10=-546 (LC 12)
Max Grav 6=3704 (LC 2), 10=3921 (LC 2)
1 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4200/595, 2-11=-3192/497, 3-11=-3177/526, 3-12=-3177/526, 4-12=-3192/497, 4-5=-4199/594, 1-10=-3057/453,5-6=-3058/452
BOT CHORD 10-13=-241/657, 13-14=-241/657, 9-14=-241/657, 9-15=-507/3365, 15-16=-507/3365, 16-17=-507/3365, 8-17=-507/3365,
8-18=-432/3366, 18-19=-432/3366, 7-19=-432/3366, 7-20=-105/558, 20-21=-105/558, 6-21=-105/558
WEBS 2-9=-124/1028, 2-8=-1058/275, 3-8=-475/3190, 4-8=-1058/274, 4-7=-123/1027, 1-9=-359/2929, 5-7=-362/2939
NOTES
1)2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.
Web connected as follows: 2x4 - 1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided todistribute only loads noted as (F) or (B), unless otherwise indicated.
3)Unbalanced roof live loads have been considered for this design.
4)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
6)Unbalanced snow loads have been considered for this design.
7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 546 lb uplift at joint 10 and 516 lb uplift at joint 6.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 689 lb down and 97 lb up at 0-11-4, 686 lb down and 99 lb up at 2-11-4,686 lb down and 99 lb up at 4-11-4, 686 lb down and 99 lb up at 6-11-4, 686 lb down and 99 lb up at 8-11-4, 686 lb down and 99 lb up at 10-11-4, 686 lb down and 98 lb upat 12-11-4, and 686 lb down and 98 lb up at 14-11-4, and 686 lb down and 98 lb up at 16-11-4 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (lb/ft)
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
G01 1 22107035-12T Common Girder Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:QoPRQyZgDhnSpyIinKS6iYySXEo-KHYwtVEPhX95qHJBPblUE__2NfEiHTFjcq0PsQyf449
Continued on page 2
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Vert: 1-3=-51, 3-5=-51, 6-10=-20
Concentrated Loads (lb)
Vert: 13=-644 (B), 14=-641 (B), 15=-641 (B), 16=-641 (B), 17=-641 (B), 18=-641 (B), 19=-641 (B), 20=-641 (B), 21=-641 (B)
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
G01 1 22107035-12T Common Girder Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 2
ID:QoPRQyZgDhnSpyIinKS6iYySXEo-KHYwtVEPhX95qHJBPblUE__2NfEiHTFjcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=4x6
=4x8
=8x8
=3x5 =4x6
=8x8
=3x5
=8x8
=4x8
=4x6
10
13 14 9 15 16 178 18 19 7 20 21
6
51
421211
3
T1 T1
W1 W1
B1B1
W3 W4
W5
W4 W3
W2 W2
4-9-4
4-9-4
4-5-12
9-3-0
4-5-12
13-8-12
4-9-4
18-6-0
4-6-5
4-6-5
4-6-5
18-6-0
4-8-11
13-11-11
4-8-11
9-3-01-2-67-4-6Scale = 1:36.6
Plate Offsets (X, Y):[4:0-0-0,0-0-0], [6:Edge,0-2-0], [7:0-3-8,0-4-8], [8:0-4-0,0-4-8], [9:0-3-8,0-4-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.26 Vert(LL)-0.06 8-9 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.72 Vert(CT)-0.12 8-9 >999 180
TCDL 10.0 Rep Stress Incr NO WB 0.79 Horz(CT)0.02 6 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 198 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud *Except* W1:2x6 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-7-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)6=3842/0-6-0, (min. 0-3-5), 10=4074/0-6-0, (min. 0-3-8)
Max Horiz 10=-193 (LC 8)
Max Uplift 6=-582 (LC 13), 10=-616 (LC 12)
Max Grav 6=4232 (LC 2), 10=4486 (LC 2)
3 3FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4796/668, 2-11=-3640/552, 3-11=-3626/582, 3-12=-3626/582, 4-12=-3641/552, 4-5=-4794/668, 1-10=-3481/505,5-6=-3482/505
BOT CHORD 10-13=-251/732, 13-14=-251/732, 9-14=-251/732, 9-15=-566/3848, 15-16=-566/3848, 16-17=-566/3848, 8-17=-566/3848,
8-18=-493/3848, 18-19=-493/3848, 7-19=-493/3848, 7-20=-115/636, 20-21=-115/636, 6-21=-115/636
WEBS 2-9=-147/1211, 2-8=-1203/293, 3-8=-536/3684, 4-8=-1202/293, 4-7=-147/1208, 1-9=-411/3353, 5-7=-415/3364
NOTES
1)2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc.Web connected as follows: 2x4 - 1 row at 0-9-0 oc.2)All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to
distribute only loads noted as (F) or (B), unless otherwise indicated.
3)Unbalanced roof live loads have been considered for this design.
4)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever leftand right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
6)Unbalanced snow loads have been considered for this design.
7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 582 lb uplift at joint 6 and 616 lb uplift at joint 10.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 810 lb down and 112 lb up at 0-11-4, 808 lb down and 113 lb up at 2-11-4,
808 lb down and 113 lb up at 4-11-4, 808 lb down and 113 lb up at 6-11-4, 808 lb down and 113 lb up at 8-11-4, 808 lb down and 113 lb up at 10-11-4, 808 lb down and 113
lb up at 12-11-4, and 808 lb down and 113 lb up at 14-11-4, and 807 lb down and 114 lb up at 16-11-4 on bottom chord. The design/selection of such connection device(s) is
the responsibility of others.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (lb/ft)
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
G02 1 22107035-12T Common Girder Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:bj9tQ9JZckbfFU2dPLZeDdySXDq-oU5I5rF1SqHySRuNyJGjnCXBn2YQ0ursrUlzPsyf448
Continued on page 2
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Vert: 1-3=-51, 3-5=-51, 6-10=-20
Concentrated Loads (lb)
Vert: 13=-740 (F), 14=-737 (F), 15=-737 (F), 16=-737 (F), 17=-737 (F), 18=-737 (F), 19=-737 (F), 20=-737 (F), 21=-737 (F)
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
G02 1 22107035-12T Common Girder Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 2
ID:bj9tQ9JZckbfFU2dPLZeDdySXDq-oU5I5rF1SqHySRuNyJGjnCXBn2YQ0ursrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=2x4
=3x5
=3x5
=3x5
=4x4
=3x8
=3x5
=3x5
=3x5
=2x4
12
15 11 16 17 10 18 9 19
8
71
62
1413
53
4
T1 T1
W1 W1
B1
W2 W2
W3 W4
W5
W4 W3
0-10-12
12-10-12
0-10-12
-0-10-12
2-10-4
8-10-4
2-10-4
6-0-0
3-1-12
12-0-0
3-1-12
3-1-12
2-10-4
8-10-4
2-10-4
6-0-0
3-1-12
12-0-0
3-1-12
3-1-121-7-115-7-11Scale = 1:31.7
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.26 Vert(LL)-0.02 9-10 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.34 Vert(CT)-0.03 9-10 >999 180
TCDL 10.0 Rep Stress Incr NO WB 0.46 Horz(CT)0.01 8 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 142 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)8=2186/0-6-0, (min. 0-1-14), 12=2436/0-6-0, (min. 0-2-2)
Max Horiz 12=-171 (LC 10)
Max Uplift 8=-344 (LC 13), 12=-382 (LC 12)
Max Grav 8=2415 (LC 2), 12=2688 (LC 2)
5 5FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-13=-2402/339, 3-13=-2341/350, 3-4=-1985/339, 4-5=-1985/339, 5-14=-2270/340, 6-14=-2331/329, 2-12=-2329/349,
6-8=-2264/340
BOT CHORD 11-16=-278/1955, 16-17=-278/1955, 10-17=-278/1955, 10-18=-227/1897, 9-18=-227/1897
WEBS 2-11=-258/2140, 6-9=-249/2075, 3-11=-78/509, 3-10=-552/161, 4-10=-315/1989, 5-10=-462/149, 5-9=-64/401
NOTES
1)2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Web connected as follows: 2x4 - 1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to
distribute only loads noted as (F) or (B), unless otherwise indicated.
3)Unbalanced roof live loads have been considered for this design.
4)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
6)Unbalanced snow loads have been considered for this design.
7)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 382 lb uplift at joint 12 and 344 lb uplift at joint 8.
10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 808 lb down and 113 lb up at 1-7-4, 808 lb down and 113 lb up at 3-7-4,808 lb down and 113 lb up at 5-7-4, and 808 lb down and 113 lb up at 7-7-4, and 808 lb down and 113 lb up at 9-7-4 on bottom chord. The design/selection of suchconnection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (lb/ft)
Vert: 1-2=-51, 2-4=-51, 4-6=-51, 6-7=-51, 8-12=-20
Concentrated Loads (lb)
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
G03 1 22107035-12T Common Girder Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:By20VZvgJUer?sjrDQQu9lySXD4-oU5I5rF1SqHySRuNyJGjnCXCt2eT0z1srUlzPsyf448
Continued on page 2
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
Vert: 15=-737 (B), 16=-737 (B), 17=-737 (B), 18=-737 (B), 19=-737 (B)
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
G03 1 22107035-12T Common Girder Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 2
ID:By20VZvgJUer?sjrDQQu9lySXD4-oU5I5rF1SqHySRuNyJGjnCXCt2eT0z1srUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4 =3x4
=3x4
=4x4
=3x4
=3x4
25
24 23 22 21 20 19 18 17 16 15
14
1 13
122
113
26 27
104
95
6 8
7
W1
T1 T1
W1
B1 B2
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
ST1
0-10-12
18-10-12
0-10-12
-0-10-12
9-0-0
9-0-0
9-0-0
18-0-0
18-0-01-7-117-7-11Scale = 1:39
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.21 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.11 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.29 Horz(CT)0.00 14 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR
BCDL 10.0 Weight: 93 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 18-0-0.
(lb) -Max Horiz 25=-226 (LC 14)
Max Uplift All uplift 100 (lb) or less at joint(s) 16, 17, 18, 20, 21, 23 except
14=-201 (LC 13), 15=-195 (LC 12), 24=-214 (LC 13), 25=-226
(LC 12)
Max Grav All reactions 250 (lb) or less at joint(s) 14, 16, 17, 18, 19, 20,
21, 23 except 15=269 (LC 15), 24=290 (LC 14), 25=253 (LC
15)
7 7FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 6-7=-144/313, 7-8=-144/313
WEBS 7-19=-266/64
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) -0-10-12 to 2-1-4, Exterior(2N) 2-1-4 to 9-0-0, Corner(3R) 9-0-0 to 12-0-0, Exterior(2N) 12-0-0 to 18-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
7)All plates are 1.5x4 MT20 unless otherwise indicated.
8)Gable requires continuous bottom chord bearing.
9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10)Gable studs spaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 23, 18, 17, 16 except (jt=lb) 25=225, 14=200,
24=214, 15=194.
13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
GE01 1 12107035-12T Common Supported Gable Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:3reQNbbh47UlR5O0S5nZCBySXZQ-OvQASpD99vvNb_9oHAj09ZviPrgGpgxQ9XXIoXyf44B
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4 =3x4
=3x4
=4x4
=3x4
=3x4
24
23 22 21 20 19 18 17 16 15 14
13
1
122
113
25
104
5 9
6 8
7
W1
T1 T2
W1
B1 B2
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
ST1
0-10-12
-0-10-12
9-0-0
9-0-0
9-0-0
18-0-0
18-0-01-7-117-7-11Scale = 1:39
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.20 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.11 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.28 Horz(CT)0.00 13 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR
BCDL 10.0 Weight: 92 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 18-0-0.
(lb) -Max Horiz 24=220 (LC 13)
Max Uplift All uplift 100 (lb) or less at joint(s) 15, 16, 17, 19, 20, 22 except
13=-199 (LC 15), 14=-183 (LC 12), 23=-228 (LC 13), 24=-223
(LC 12)
Max Grav All reactions 250 (lb) or less at joint(s) 13, 15, 16, 17, 18, 19,
20, 22 except 14=275 (LC 15), 23=287 (LC 14), 24=262 (LC
31)
8 8FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 6-7=-144/302, 7-8=-144/302
WEBS 7-18=-254/63
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) -0-10-12 to 2-1-4, Exterior(2N) 2-1-4 to 9-0-0, Corner(3R) 9-0-0 to 12-0-0, Exterior(2N) 12-0-0 to 17-10-4 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
7)All plates are 1.5x4 MT20 unless otherwise indicated.
8)Gable requires continuous bottom chord bearing.
9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10)Gable studs spaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 20, 22, 17, 16, 15 except (jt=lb) 24=223, 13=198,
23=227, 14=182.
13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
GE02 1 12107035-12T Common Supported Gable Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:QpSJQJfqvf61YtHzFfMkvEySXZL-KHYwtVEPhX95qHJBPblUE__2yfMnHZejcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x6
=3x4
=4x4
=3x6
27
26 25 24 23 22 21 20 19 18 17
16
151
142133
2928124
115
106
97
8
W1
T1 T1
W1
B1 B2
ST6
ST5
ST4
ST3
ST2
ST1
ST5
ST4
ST3
ST2
ST1
0-10-12
21-10-12
0-10-12
-0-10-12
10-6-0
10-6-0
10-6-0
21-0-0
21-0-01-7-118-7-11Scale = 1:43.7
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.18 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.18 Horz(CT)0.00 16 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR
BCDL 10.0 Weight: 114 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud *Except* ST6:2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 8-21
MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 21-0-0.
(lb) -Max Horiz 27=-253 (LC 14)
Max Uplift All uplift 100 (lb) or less at joint(s) 16, 18, 19, 20, 22, 23, 25
except 17=-143 (LC 17), 26=-147 (LC 16), 27=-118 (LC 12)
Max Grav All reactions 250 (lb) or less at joint(s) 16, 18, 19, 20, 21, 22,
23, 25, 27 except 17=266 (LC 31), 26=276 (LC 30)
9 9FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-27=-252/216, 6-7=-153/282, 7-8=-187/342, 8-9=-187/342, 9-10=-154/282
WEBS 8-21=-303/109, 3-27=-342/301, 13-16=-304/263
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) -0-10-12 to 2-1-4, Exterior(2N) 2-1-4 to 10-6-0, Corner(3R) 10-6-0 to 13-6-0, Exterior(2N) 13-6-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical
left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
7)All plates are 1.5x4 MT20 unless otherwise indicated.8)Gable requires continuous bottom chord bearing.
9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10)Gable studs spaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 22, 23, 25, 20, 19, 18 except (jt=lb) 27=117, 26=147,
17=142.
13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
GE03 1 12107035-12T Common Supported Gable Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:FypahMjbUVsBGok7bvT88VySXZF-oU5I5rF1SqHySRuNyJGjnCXD32iO02LsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x5
=3x4
=4x4
=3x5
26
25 24 23 22 21 20 19 18 17 16
15
14
1 13212
28311
27
4 10
5 9
86
7
W1
T1 T2
W1
B1 B2
ST6
ST5
ST4
ST3
ST2
ST1
ST5
ST4
ST3
ST2
ST1
0-10-12
21-10-12
10-6-0
10-6-0
10-6-0
21-0-0
21-0-01-7-118-7-11Scale = 1:43.7
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.17 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.18 Horz(CT)0.00 15 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR
BCDL 10.0 Weight: 113 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud *Except* ST6:2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 7-20
MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 21-0-0.
(lb) -Max Horiz 26=-246 (LC 14)
Max Uplift All uplift 100 (lb) or less at joint(s) 15, 17, 18, 19, 21, 22, 24
except 16=-146 (LC 17), 25=-142 (LC 16), 26=-120 (LC 12)
Max Grav All reactions 250 (lb) or less at joint(s) 15, 17, 18, 19, 20, 21,
22, 24, 26 except 16=258 (LC 31), 25=288 (LC 30)
10 10FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-159/275, 6-7=-192/335, 7-8=-192/335, 8-9=-159/275
WEBS 7-20=-295/114, 2-26=-327/301, 12-15=-310/252
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-1-12 to 3-1-12, Exterior(2N) 3-1-12 to 10-6-0, Corner(3R) 10-6-0 to 13-6-0, Exterior(2N) 13-6-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical
left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
7)All plates are 1.5x4 MT20 unless otherwise indicated.8)Gable requires continuous bottom chord bearing.
9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10)Gable studs spaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 21, 22, 24, 19, 18, 17 except (jt=lb) 26=120, 25=142,
16=145.
13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
GE04 1 12107035-12T Common Supported Gable Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:uLYptRLPC7AYBytR3QjL6fyMw4C-oU5I5rF1SqHySRuNyJGjnCXDF2iM02LsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=2x4
=4x4
=2x4
16
15 14 13 12 11
10
1 9
2 8
3 7
4 6
5
W1
T1T1
W1
B1
ST3
ST2
ST1
ST2
ST1
0-10-12
-0-10-12
0-10-12
12-10-12
6-0-0
12-0-0
6-0-0
6-0-0
12-0-01-7-115-7-11Scale = 1:30.1
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.14 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.12 Horz(CT)0.00 10 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR
BCDL 10.0 Weight: 56 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 12-0-0.
(lb) -Max Horiz 16=174 (LC 15)
Max Uplift All uplift 100 (lb) or less at joint(s) 10, 12, 14, 16 except
11=-102 (LC 17), 15=-103 (LC 16)
Max Grav All reactions 250 (lb) or less at joint(s) 10, 11, 12, 13, 14, 15, 16
11 11FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-118/266, 4-5=-118/266
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) -0-10-12 to 2-0-0, Exterior(2N) 2-0-0 to 6-0-0, Corner(3R) 6-0-0 to 9-0-0, Exterior(2N) 9-0-0 to 12-10-12 zone; cantilever left and right exposed ; end vertical left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
7)All plates are 1.5x4 MT20 unless otherwise indicated.
8)Gable requires continuous bottom chord bearing.
9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).10)Gable studs spaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 16, 12, 14 except (jt=lb) 11=101, 15=102.
13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
GE05 1 12107035-12T Common Supported Gable Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:0VIcM5qccyt2D0Lg3bc0TBySXZ7-oU5I5rF1SqHySRuNyJGjnCXDl2iT03OsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
412
=3x4
=6x8
=4x4
=3x4
=2x4
=4x6
=5x6
=4x4
=6x8
=3x4
42 43 44
15
14 41 13 12 45 11
10
91
8237
3738
363946
3540
5
T1T1
W1W1
B2B1
W11W2W10W3
W9W4W8
W7W6
W5
ST6
ST4
ST5
ST3
ST2
ST1
ST7
ST8
ST9
ST10
ST11
0-3-11 0-4-12
0-10-12
-0-10-12
0-10-12
21-10-12
0-8-15
0-8-15
0-10-0
21-0-0
4-6-13
20-2-0
4-6-14
5-3-14
5-1-3
15-7-3
5-2-2
10-6-0
0-0-15
0-8-15
0-2-0
20-4-0
0-8-0
21-0-0
0-8-0
0-8-0
6-1-2
20-2-0
6-1-11
6-10-10
7-2-4
14-0-141-3-134-9-13Scale = 1:39.2
Plate Offsets (X, Y):[5:0-2-0,0-0-8], [12:0-3-0,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.37 Vert(LL)0.18 12-13 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(CT)-0.14 12-13 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.63 Horz(CT)-0.03 14 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 112 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 5-7-2 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)11=789/0-4-0, (min. 0-1-8), 14=783/0-4-0, (min. 0-1-8)
Max Horiz 11=-31 (LC 17)
Max Uplift 11=-386 (LC 13), 14=-383 (LC 12)
Max Grav 11=895 (LC 2), 14=887 (LC 2)
12 12FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-35=-999/1237, 6-35=-1051/1226, 4-40=-1062/1236, 5-40=-1009/1248
BOT CHORD 14-41=-995/981, 13-41=-995/981, 13-42=-817/820, 42-43=-817/820, 43-44=-817/820, 12-44=-817/820, 12-45=-1021/967,11-45=-1021/967
WEBS 7-11=-264/160, 3-14=-271/164, 6-11=-1075/1045, 4-14=-1078/1046, 5-12=-405/266, 5-13=-414/276
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Exterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 10-6-0, Exterior(2R) 10-6-0 to 13-6-0, Interior (1) 13-6-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical left
and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
7)All plates are 1.5x4 MT20 unless otherwise indicated.
8)Gable studs spaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 386 lb uplift at joint 11 and 383 lb uplift at joint 14.
11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
GE06 1 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:2eJj9XkDXCZDTfXlUwvm3JySXU4-oU5I5rF1SqHySRuNyJGjnCXA32dV0xJsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4
=3x6
=4x4
=4x4
=5x8
=4x4
=3x6 =3x4
10
9
8
1 7
62
11 16
53
1512
1413
4
T1 T1
W1 W1
B1 B1
W4
W3W3W2 W2
0-10-12
18-10-12
0-10-12
-0-10-12
4-7-6
9-0-0
4-7-6
13-7-6
4-4-10
18-0-0
4-4-10
4-4-10
9-0-0
9-0-0
9-0-0
18-0-01-7-117-7-11Scale = 1:38.8
Plate Offsets (X, Y):[9:0-4-0,0-3-4]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.33 Vert(LL)-0.12 8-9 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.65 Vert(CT)-0.25 9-10 >848 180
TCDL 10.0 Rep Stress Incr YES WB 0.47 Horz(CT)0.02 8 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 85 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)8=680/0-6-0, (min. 0-1-8), 10=680/0-6-0, (min. 0-1-8)
Max Horiz 10=226 (LC 15)
Max Uplift 8=-110 (LC 17), 10=-110 (LC 16)
Max Grav 8=771 (LC 2), 10=771 (LC 2)
13 13FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-12=-630/129, 12-13=-573/137, 4-13=-547/157, 4-14=-547/157, 14-15=-573/137, 5-15=-630/129
BOT CHORD 9-10=-113/604, 8-9=-60/534
WEBS 4-9=-53/399, 3-10=-656/96, 5-8=-656/96
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior (1) 12-0-0 to 18-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 10 and 110 lb uplift at joint 8.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T01 1 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:JfoXXwX_xnBpBxnpTmfcqQySXYD-KHYwtVEPhX95qHJBPblUE__0ufDPHWajcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=1.5x4
=3x5
=3x8
=MT18HS 6x12
=4x10
=4x6
=3x8
=4x10
=MT18HS 6x12
=3x8
=3x5
=1.5x4
14 13 9 8
71
12 11 10
2 6
201553
16 19
17 18
4
T1 T1
W1 W1
B1 B1
B2
B3
B2
W5
W4W4
W2 W2
W3 W3
0-10-12
18-10-12
0-10-12
-0-10-12
2-6-15
18-0-0
2-6-15
2-6-15
6-5-1
9-0-0
6-5-1
15-5-1
2-6-0
2-6-0
2-6-0
18-0-0
6-6-0
9-0-0
6-6-0
15-6-01-7-111-0-07-7-11Scale = 1:40.7
Plate Offsets (X, Y):[3:0-2-4,0-2-0], [5:0-2-4,0-2-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.55 Vert(LL)-0.05 10-11 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.72 Vert(CT)-0.12 10-11 >999 180 MT18HS 197/144
TCDL 10.0 Rep Stress Incr YES WB 0.40 Horz(CT)0.11 8 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 88 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)8=680/0-6-0, (min. 0-1-8), 14=680/0-6-0, (min. 0-1-8)
Max Horiz 14=-226 (LC 14)
Max Uplift 8=-110 (LC 17), 14=-110 (LC 16)
Max Grav 8=771 (LC 2), 14=771 (LC 2)
14 14FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-638/112, 3-15=-573/114, 3-16=-749/110, 16-17=-633/121, 4-17=-631/141, 4-18=-631/152, 18-19=-633/132,5-19=-749/123, 5-20=-573/110, 6-20=-638/107, 2-14=-791/138, 6-8=-791/146
BOT CHORD 11-12=-238/981, 10-11=-137/833
WEBS 4-11=-9/423, 5-11=-389/248, 3-11=-444/270, 2-13=-60/576, 6-9=-58/576
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior (1) 12-0-0 to 18-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)All plates are MT20 plates unless otherwise indicated.
7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 14 and 110 lb uplift at joint 8.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T02 2 12107035-12T Roof Special Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:asaB7055CJNM7kvuxTMeWjySXN9-KHYwtVEPhX95qHJBPblUE__zVfCAHXijcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=1.5x4
=3x5
=3x8 =6x8
=4x10
=4x6
=3x8
=4x10
=6x8
=3x8
=3x5
=1.5x4
13 12 8 7
1
11 10 9
2 6
14 53
19
15 18
16 17
4
T1 T2
W1 W1
B1 B1
B2
B3
B2
W5
W4W4
W2 W2
W3 W3
1-0-80-10-12
-0-10-12
2-6-15
18-0-0
2-6-15
2-6-15
6-5-1
9-0-0
6-5-1
15-5-1
2-6-0
2-6-0
2-6-0
18-0-0
6-6-0
9-0-0
6-6-0
15-6-01-7-111-0-81-0-07-7-11Scale = 1:38.6
Plate Offsets (X, Y):[3:0-2-4,0-2-0], [5:0-2-4,0-2-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.55 Vert(LL)-0.05 9-10 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(CT)-0.12 9-10 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.40 Horz(CT)0.11 7 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 86 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)7=625/ Mechanical, (min. 0-1-8), 13=681/0-6-0, (min. 0-1-8)
Max Horiz 13=-201 (LC 14)
Max Uplift 7=-86 (LC 17), 13=-108 (LC 16)
Max Grav 7=706 (LC 2), 13=773 (LC 2)
15 15FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-14=-640/113, 3-14=-575/115, 3-15=-752/111, 15-16=-636/126, 4-16=-634/146, 4-17=-634/155, 17-18=-636/134,18-19=-731/128, 5-19=-752/111, 5-6=-646/102, 2-13=-793/142, 6-7=-728/104
BOT CHORD 10-11=-295/955, 9-10=-144/848, 8-9=-250/49
WEBS 4-10=-13/424, 5-10=-402/250, 3-10=-437/284, 2-12=-60/578, 6-8=-73/584
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior (1) 12-0-0 to 17-10-4 zone; cantilever left exposed ; end vertical left exposed;C-Cfor members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Refer to girder(s) for truss to truss connections.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 13 and 86 lb uplift at joint 7.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T03 3 12107035-12T Roof Special Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:tDVqbPAUZTGNTpxErR_HICySXN2-KHYwtVEPhX95qHJBPblUE__zVfCtHXojcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4
=3x6
=4x4
=4x4
=5x8
=4x4
=3x6 =3x4
9
8
7
1
2 6
10
15
53
1411
1312
4
T1 T2
W1 W1
B1 B1
W4
W3W3W2 W2
0-10-12
-0-10-12
4-7-6
13-7-6
4-7-6
9-0-0
4-4-10
4-4-10
4-4-10
18-0-0
9-0-0
9-0-0
9-0-0
18-0-01-7-111-0-87-7-11Scale = 1:38.8
Plate Offsets (X, Y):[8:0-4-0,0-3-4]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.33 Vert(LL)-0.12 7-8 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.65 Vert(CT)-0.25 7-8 >848 180
TCDL 10.0 Rep Stress Incr YES WB 0.48 Horz(CT)0.02 7 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 84 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)7=625/ Mechanical, (min. 0-1-8), 9=681/0-6-0, (min. 0-1-8)
Max Horiz 9=220 (LC 13)
Max Uplift 7=-87 (LC 17), 9=-109 (LC 16)
Max Grav 7=706 (LC 2), 9=773 (LC 2)
16 16FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-11=-633/128, 11-12=-575/136, 4-12=-549/156, 4-13=-549/156, 13-14=-576/136, 5-14=-634/128
BOT CHORD 8-9=-125/597, 7-8=-95/542
WEBS 4-8=-52/401, 3-9=-658/95, 5-7=-668/129
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 9-0-0, Exterior(2R) 9-0-0 to 12-0-0, Interior (1) 12-0-0 to 17-10-4 zone; cantilever left and right exposed ; end vertical left andright exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Refer to girder(s) for truss to truss connections.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 9 and 87 lb uplift at joint 7.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T04 6 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:8p9oozblXdxzvsEzp1m03hySXY7-KHYwtVEPhX95qHJBPblUE__0ufDOHWRjcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4
=3x8
=4x4
=4x4
=6x8
=4x4
=3x8 =3x4
10
9
8
7162
3 5
11 14
12 13
4
T1 T1
W1 W1
B1 B1
W3
W4
W3W2 W5
0-2-12
18-8-12
0-2-12
-0-2-12
4-2-14
4-2-14
4-2-15
18-6-0
5-0-1
14-3-1
5-0-2
9-3-0
9-3-0
9-3-0
9-3-0
18-6-01-2-67-4-6Scale = 1:37.8
Plate Offsets (X, Y):[9:0-4-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.38 Vert(LL)-0.14 9-10 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.69 Vert(CT)-0.28 9-10 >791 180
TCDL 10.0 Rep Stress Incr YES WB 0.42 Horz(CT)0.02 8 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 82 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)8=664/0-6-0, (min. 0-1-8), 10=664/0-6-0, (min. 0-1-8)
Max Horiz 10=-200 (LC 14)
Max Uplift 8=-99 (LC 17), 10=-86 (LC 16)
Max Grav 8=751 (LC 2), 10=751 (LC 2)
17 17FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-11=-697/124, 11-12=-626/134, 4-12=-607/154, 4-13=-607/154, 13-14=-626/134, 5-14=-697/123
BOT CHORD 9-10=-150/687, 8-9=-88/631
WEBS 4-9=-39/442, 3-10=-676/129, 5-8=-675/128
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-2-12 to 2-9-4, Interior (1) 2-9-4 to 9-3-0, Exterior(2R) 9-3-0 to 12-3-0, Interior (1) 12-3-0 to 18-8-12 zone; cantilever left and right exposed ; end vertical left andright exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint 10 and 99 lb uplift at joint 8.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T05 7 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:0aPJeLeGbrRPNTYk2tqyEXySXY3-KHYwtVEPhX95qHJBPblUE__0CfDlHXRjcq0PsQyf449
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4
=3x8 =4x4
=4x4
=5x10
=4x4
=3x8 =3x4
10
9
8
71
62
53
11 14
12 13
4
T1 T1
W1 W1
B1 B1
W2 W2
W4
W3 W3
0-10-12
21-10-12
0-10-12
-0-10-12
4-10-8
4-10-8
4-10-8
21-0-0
5-7-8
10-6-0
5-7-8
16-1-8
10-6-0
10-6-0
10-6-0
21-0-01-7-118-7-11Scale = 1:43.8
Plate Offsets (X, Y):[9:0-5-0,0-3-4]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.47 Vert(LL)-0.23 9-10 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.89 Vert(CT)-0.46 9-10 >541 180
TCDL 10.0 Rep Stress Incr YES WB 0.68 Horz(CT)0.02 8 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 97 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)8=786/0-6-0, (min. 0-1-8), 10=786/0-6-0, (min. 0-1-8)
Max Horiz 10=-253 (LC 14)
Max Uplift 8=-125 (LC 17), 10=-125 (LC 16)
Max Grav 8=891 (LC 2), 10=891 (LC 2)
18 18FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-11=-762/143, 11-12=-671/157, 4-12=-661/177, 4-13=-661/177, 13-14=-671/157, 5-14=-762/143, 2-10=-268/109,6-8=-268/109
BOT CHORD 9-10=-149/738, 8-9=-76/661
WEBS 3-10=-789/127, 5-8=-789/127, 4-9=-50/481
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 10-6-0, Exterior(2R) 10-6-0 to 13-6-0, Interior (1) 13-6-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 125 lb uplift at joint 10 and 125 lb uplift at joint 8.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T06 3 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:NYCCh2iOPO4hUEQirQQ7xaySXY_-oU5I5rF1SqHySRuNyJGjnCX8U2Wn0wYsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4
=3x8
=4x4
=4x4
=5x10
=4x4
=3x8 =3x4
9
8
7
6
51
42
1310
1211
3
T1 T2
W1 W1
B1 B1
W2 W2
W4
W3 W3
0-10-12
21-10-12
4-10-8
4-10-8
4-10-8
21-0-0
5-7-8
10-6-0
5-7-8
16-1-8
10-6-0
10-6-0
10-6-0
21-0-01-7-111-7-118-7-11Scale = 1:43.8
Plate Offsets (X, Y):[8:0-5-0,0-3-4]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.47 Vert(LL)-0.23 8-9 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.89 Vert(CT)-0.46 8-9 >540 180
TCDL 10.0 Rep Stress Incr YES WB 0.70 Horz(CT)0.02 7 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 96 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)7=787/0-6-0, (min. 0-1-8), 9=732/ Mechanical, (min. 0-1-8)
Max Horiz 9=-246 (LC 12)
Max Uplift 7=-125 (LC 17), 9=-102 (LC 16)
Max Grav 7=892 (LC 2), 9=827 (LC 2)
19 19FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-10=-765/142, 10-11=-674/156, 3-11=-663/176, 3-12=-663/176, 12-13=-673/156, 4-13=-764/142, 5-7=-268/109
BOT CHORD 8-9=-148/744, 7-8=-76/663
WEBS 2-9=-804/160, 4-7=-791/126, 3-8=-49/483
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) 0-1-12 to 3-1-12, Interior (1) 3-1-12 to 10-6-0, Exterior(2R) 10-6-0 to 13-6-0, Interior (1) 13-6-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Refer to girder(s) for truss to truss connections.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 102 lb uplift at joint 9 and 125 lb uplift at joint 7.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T07 2 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:HqIGv_QXQWQmzp7xWAyuY1ySXUT-oU5I5rF1SqHySRuNyJGjnCX8T2Wm0wKsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=2x4
=3x8 =4x4
=4x4
=5x10
=4x4
=3x8 =2x4
8
7
6
51
2 4
129
1110
3
T1 T1
W1 W1
B1 B1
W2 W5
W4
W3 W3
4-10-7
4-10-7
4-10-8
21-0-0
5-7-8
16-1-8
5-7-9
10-6-0
10-6-0
10-6-0
10-6-0
21-0-01-7-111-7-118-7-11Scale = 1:43.2
Plate Offsets (X, Y):[7:0-5-0,0-3-4]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.46 Vert(LL)-0.23 7-8 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.89 Vert(CT)-0.46 7-8 >540 180
TCDL 10.0 Rep Stress Incr YES WB 0.70 Horz(CT)0.02 6 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 95 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)6=733/0-6-0, (min. 0-1-8), 8=733/ Mechanical, (min. 0-1-8)
Max Horiz 8=-234 (LC 12)
Max Uplift 6=-101 (LC 17), 8=-101 (LC 16)
Max Grav 6=828 (LC 2), 8=828 (LC 2)
20 20FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-9=-767/141, 9-10=-676/155, 3-10=-665/175, 3-11=-665/175, 11-12=-676/155, 4-12=-767/141
BOT CHORD 7-8=-159/737, 6-7=-110/671
WEBS 2-8=-807/160, 4-6=-806/159, 3-7=-49/484
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) 0-1-12 to 3-1-12, Interior (1) 3-1-12 to 10-6-0, Exterior(2R) 10-6-0 to 13-6-0, Interior (1) 13-6-0 to 20-10-4 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)Refer to girder(s) for truss to truss connections.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 8 and 101 lb uplift at joint 6.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T08 7 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:AbYnlMU1UlwCSRRil01qjtySXUP-oU5I5rF1SqHySRuNyJGjnCX8c2Wm0wIsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
412
=1.5x4
=3x4
=6x8 =1.5x4
=4x4
=3x4
=4x6
=5x6
=4x4
=6x8 =1.5x4
=3x4
=1.5x4
23 24 25
15
14 22 13 12 26 11
10
918237
1819
172046
1621
5
T1T1
W1W1
B2B1
W11W2W10W3
W9W4W8
W7W6
W5
0-3-11 0-4-12
0-10-12
21-10-12
0-10-12
-0-10-12
0-8-15
0-8-15
0-10-0
21-0-0
4-6-13
20-2-0
4-6-14
5-3-14
5-1-3
15-7-3
5-2-2
10-6-0
0-0-15
0-8-15
0-2-0
20-4-0
0-8-0
21-0-0
0-8-0
0-8-0
6-1-2
20-2-0
6-1-11
6-10-10
7-2-4
14-0-141-3-134-9-13Scale = 1:39.2
Plate Offsets (X, Y):[12:0-3-0,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.37 Vert(LL)0.18 12-13 >999 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(CT)-0.14 12-13 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.63 Horz(CT)-0.03 14 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 89 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 5-7-2 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)11=789/0-4-0, (min. 0-1-8), 14=783/0-4-0, (min. 0-1-8)
Max Horiz 11=-31 (LC 17)
Max Uplift 11=-386 (LC 13), 14=-383 (LC 12)
Max Grav 11=895 (LC 2), 14=887 (LC 2)
21 21FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-16=-999/1237, 6-16=-1051/1226, 4-21=-1062/1236, 5-21=-1009/1248
BOT CHORD 14-22=-995/981, 13-22=-995/981, 13-23=-817/820, 23-24=-817/820, 24-25=-817/820, 12-25=-817/820, 12-26=-1021/967,
11-26=-1021/967
WEBS 7-11=-264/160, 3-14=-271/164, 6-11=-1075/1045, 4-14=-1078/1046, 5-12=-405/266, 5-13=-414/276
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 10-6-0, Exterior(2R) 10-6-0 to 13-6-0, Interior (1) 13-6-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 386 lb uplift at joint 11 and 383 lb uplift at joint 14.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T09 1 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:2eJj9XkDXCZDTfXlUwvm3JySXU4-oU5I5rF1SqHySRuNyJGjnCXA32dV0xJsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
412
=3x4
=5x6
=4x6
=3x8 =4x4
=3x4
=5x6
=3x4
=3x4
=3x4
=1.5x4
14
13 1211 19 10
9
81726
1617
153
518
4
T1T1
W1W1
B2B1
W2
W9W8
W4
W5 W6
W7
W3
0-4-12
0-10-12
-0-10-12
0-10-12
21-10-12
0-10-0
21-0-0
3-3-0
13-9-0
4-10-4
4-10-4
5-7-12
10-6-0
6-5-0
20-2-0
0-2-0
20-4-0
0-8-0
21-0-0
3-4-12
13-9-0
6-5-0
20-2-0
10-4-4
10-4-41-3-134-9-13Scale = 1:39.2
Plate Offsets (X, Y):[11:0-3-0,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.54 Vert(LL)-0.27 13-14 >600 240 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.73 Vert(CT)-0.55 13-14 >298 180
TCDL 10.0 Rep Stress Incr YES WB 0.35 Horz(CT)-0.01 14 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 89 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)10=284/0-4-0, (min. 0-1-8), 12=779/0-6-0, (min. 0-1-8),14=509/0-6-0, (min. 0-1-8)
Max Horiz 10=-31 (LC 17)
Max Uplift 10=-172 (LC 13), 12=-195 (LC 13), 14=-138 (LC 12)
Max Grav 10=358 (LC 37), 12=883 (LC 2), 14=577 (LC 2)
22 22FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-336/118, 3-18=-371/83, 4-18=-298/94, 7-9=-225/262
BOT CHORD 13-14=-147/610
WEBS 3-14=-565/199, 7-10=-338/296, 6-10=-414/243, 5-13=-52/542, 5-12=-785/159, 3-13=-362/220
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 10-6-0, Exterior(2R) 10-6-0 to 13-9-0, Interior (1) 13-9-0 to 21-10-12 zone; cantilever left and right exposed ; end vertical leftand right exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 138 lb uplift at joint 14, 172 lb uplift at joint 10 and 195 lb uplift at joint 12.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
T10 2 12107035-12T Common Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:JchEsNJpNeP?XOKhT9EiCDySXQl-oU5I5rF1SqHySRuNyJGjnCX7Q2YO0?psrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
8 12
=2x4
=3x4
=2x4
1 3
2
T1 T1
B1
0-5-3
2-11-11
1-0-10
2-6-8
1-5-13
1-5-13
2-11-111-0-20-0-40-8-7Scale = 1:19.1
Plate Offsets (X, Y):[2:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.06 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 3 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 6 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide.
REACTIONS (lb/size)1=107/3-0-7, (min. 0-1-8), 3=107/3-0-7, (min. 0-1-8)
Max Horiz 1=22 (LC 13)
Max Uplift 1=-17 (LC 16), 3=-17 (LC 17)
Max Grav 1=121 (LC 2), 3=121 (LC 2)
23 23FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)Unbalanced roof live loads have been considered for this design.2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consultqualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 1 and 17 lb uplift at joint 3.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 3.
11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V01 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:O?1TTZhOGZoDFN6zqLBI2MySXIW-oU5I5rF1SqHySRuNyJGjnCXF?2jl04DsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
8 12
=3x4
=4x4
=1.5x4 =3x4
1 3
4
109
2
T1 T1
B1
ST1
0-5-3
6-11-11
3-0-10
6-6-8
3-5-13
3-5-13
6-11-112-4-20-0-42-0-7Scale = 1:20.9
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.16 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.16 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.08 Horiz(TL)0.00 4 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 18 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)1=41/7-0-7, (min. 0-1-8), 3=41/7-0-7, (min. 0-1-8), 4=417/7-0-7,
(min. 0-1-8)
Max Horiz 1=-57 (LC 12)
Max Uplift 1=-2 (LC 16), 3=-12 (LC 17), 4=-71 (LC 16)
Max Grav 1=86 (LC 22), 3=86 (LC 23), 4=471 (LC 2)
24 24FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-328/262
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 3-6-3, Corner(3R) 3-6-3 to 6-6-3, Exterior(2N) 6-6-3 to 7-0-7 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2 lb uplift at joint 1, 12 lb uplift at joint 3 and 71 lb uplift at joint 4.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 3.11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V02 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:O?1TTZhOGZoDFN6zqLBI2MySXIW-oU5I5rF1SqHySRuNyJGjnCXDN2hC03ysrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x5
=4x4
=1.5x4 =3x5
1 3
4
9 12
1110
2
T1 T1
B1
ST1
0-5-3
10-11-11
5-0-10
10-6-8
5-5-13
5-5-13
10-11-113-8-20-0-43-4-7Scale = 1:25.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.49 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.38 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.21 Horiz(TL)0.00 4 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 30 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)1=-11/11-0-7, (min. 0-1-8), 3=-11/11-0-7, (min. 0-1-8),
4=803/11-0-7, (min. 0-1-8)
Max Horiz 1=91 (LC 13)
Max Uplift 1=-77 (LC 23), 3=-77 (LC 22), 4=-167 (LC 16)
Max Grav 1=47 (LC 35), 3=54 (LC 16), 4=909 (LC 2)
25 25FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-9=-292/355, 9-10=-279/399, 2-10=-276/468, 2-11=-271/468, 11-12=-275/399, 3-12=-288/355
BOT CHORD 1-4=-372/363, 3-4=-372/363
WEBS 2-4=-707/478
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 5-6-3, Corner(3R) 5-6-3 to 8-6-3, Exterior(2N) 8-6-3 to 11-0-7 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 1, 77 lb uplift at joint 3 and 167 lb uplift at joint 4.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 3.11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V03 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:O?1TTZhOGZoDFN6zqLBI2MySXIW-oU5I5rF1SqHySRuNyJGjnCX8H2ep01usrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4 =1.5x4 =1.5x4
=4x4
=1.5x4 =1.5x4 =1.5x4
=3x4
1 5
8 7 6
1413
42
3
T1 T1
B1
ST2
ST1 ST1
0-5-3
14-11-11
7-0-10
14-6-8
7-5-13
7-5-13
14-11-115-0-20-0-44-8-7Scale = 1:30.2
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.21 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.12 Horiz(TL)0.00 5 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 45 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS All bearings 15-0-7.
(lb) -Max Horiz 1=126 (LC 15)
Max Uplift All uplift 100 (lb) or less at joint(s) 1 except 6=-150 (LC 17),
8=-152 (LC 16)
Max Grav All reactions 250 (lb) or less at joint(s) 1, 5 except 6=392 (LC23), 7=323 (LC 2), 8=392 (LC 22)
26 26FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-306/245, 4-6=-306/245
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 7-6-3, Corner(3R) 7-6-3 to 10-6-3, Exterior(2N) 10-6-3 to 15-0-7 zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=151, 6=149.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 5.
11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V04 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:sBbrgvi01tw4tXh9O2iXbZySXIV-oU5I5rF1SqHySRuNyJGjnCXCY2iK03MsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4 =1.5x4 =1.5x4
=4x4
=1.5x4 =1.5x4 =1.5x4
=3x4
1 5
8 7 6
1413
2 4
3
T1 T1
B1
ST2
ST1 ST1
0-5-3
15-4-11
7-3-2
14-11-8
7-8-5
7-8-5
15-4-115-1-130-0-44-10-2Scale = 1:30.6
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.23 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.13 Horiz(TL)0.00 5 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH
BCDL 10.0 Weight: 47 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS All bearings 15-5-7.
(lb) -Max Horiz 1=-130 (LC 12)
Max Uplift All uplift 100 (lb) or less at joint(s) 1 except 6=-154 (LC 17),
8=-156 (LC 16)
Max Grav All reactions 250 (lb) or less at joint(s) 1, 5 except 6=400 (LC23), 7=335 (LC 2), 8=400 (LC 22)
27 27FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-7=-264/34, 2-8=-309/245, 4-6=-309/245
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 7-8-11, Corner(3R) 7-8-11 to 10-8-11, Exterior(2N) 10-8-11 to 15-5-7 zone; cantilever left and right exposed ; end vertical left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=155, 6=153.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 5.
11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V05 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:sBbrgvi01tw4tXh9O2iXbZySXIV-oU5I5rF1SqHySRuNyJGjnCXCL2iG028srUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x5
=4x4
=1.5x4 =3x5
1 3
4
9 12
1110
2
T1 T1
B1
ST1
0-5-3
11-4-11
5-3-2
10-11-8
5-8-5
5-8-5
11-4-113-9-130-0-43-6-2Scale = 1:26.3
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.53 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.24 Horiz(TL)0.01 4 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 31 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 9-9-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)1=-19/11-5-7, (min. 0-1-8), 3=-19/11-5-7, (min. 0-1-8),
4=849/11-5-7, (min. 0-1-8)
Max Horiz 1=-95 (LC 12)
Max Uplift 1=-86 (LC 23), 3=-86 (LC 22), 4=-179 (LC 16)
Max Grav 1=44 (LC 17), 3=59 (LC 16), 4=961 (LC 2)
28 28FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-9=-311/384, 9-10=-297/428, 2-10=-293/503, 2-11=-288/503, 11-12=-293/428, 3-12=-307/384
BOT CHORD 1-4=-396/380, 3-4=-396/380
WEBS 2-4=-753/501
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 5-8-11, Corner(3R) 5-8-11 to 8-8-11, Exterior(2N) 8-8-11 to 11-5-7 zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint 1, 86 lb uplift at joint 3 and 179 lb uplift at joint 4.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 3.11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V06 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:KO8DuFjeoA2xVhGLymDm8nySXIU-oU5I5rF1SqHySRuNyJGjnCX7f2dV01WsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
812
=3x4
=4x4
=1.5x4 =3x4
1 3
4
109
2
T1 T1
B1
ST1
0-5-3
7-4-11
3-3-2
6-11-8
3-8-5
3-8-5
7-4-112-5-130-0-42-2-2Scale = 1:21.4
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.19 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.18 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.09 Horiz(TL)0.00 4 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 19 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 7-4-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)1=38/7-5-7, (min. 0-1-8), 3=38/7-5-7, (min. 0-1-8), 4=452/7-5-7,
(min. 0-1-8)
Max Horiz 1=-60 (LC 12)
Max Uplift 1=-7 (LC 23), 3=-12 (LC 12), 4=-79 (LC 16)
Max Grav 1=86 (LC 22), 3=86 (LC 23), 4=511 (LC 2)
29 29FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-361/284
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 3-8-11, Corner(3R) 3-8-11 to 6-5-14, Exterior(2N) 6-5-14 to 7-5-7 zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 7 lb uplift at joint 1, 12 lb uplift at joint 3 and 79 lb uplift at joint 4.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 3.11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V07 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:KO8DuFjeoA2xVhGLymDm8nySXIU-oU5I5rF1SqHySRuNyJGjnCXDz2ht03ssrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
8 12
=2x4
=3x4
=2x4
1 3
2
T1 T1
B1
0-5-3
3-4-11
1-3-2
2-11-8
1-8-5
1-8-5
3-4-111-1-130-0-40-10-2Scale = 1:18
Plate Offsets (X, Y):[2:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.07 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 3 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 7 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-4-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide.
REACTIONS (lb/size)1=122/3-5-7, (min. 0-1-8), 3=122/3-5-7, (min. 0-1-8)
Max Horiz 1=-25 (LC 12)
Max Uplift 1=-19 (LC 16), 3=-19 (LC 17)
Max Grav 1=138 (LC 22), 3=138 (LC 23)
30 30FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)Unbalanced roof live loads have been considered for this design.2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consultqualified building designer as per ANSI/TPI 1.
4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
5)Unbalanced snow loads have been considered for this design.
6)Gable requires continuous bottom chord bearing.
7)Gable studs spaced at 4-0-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 19 lb uplift at joint 1 and 19 lb uplift at joint 3.
10)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 3.
11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V08 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:KO8DuFjeoA2xVhGLymDm8nySXIU-oU5I5rF1SqHySRuNyJGjnCXEh2ia04DsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
8 12
=2x4
=3x4
=2x4
1 3
2
T1 T1
B1
0-5-3
3-9-11
1-5-10
3-4-8
1-10-13
1-10-13
3-9-111-3-80-0-40-11-12Scale = 1:18.5
Plate Offsets (X, Y):[2:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.09 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 3 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 8 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide.
REACTIONS (lb/size)1=135/3-9-11, (min. 0-1-8), 3=135/3-9-11, (min. 0-1-8)
Max Horiz 1=-29 (LC 14)
Max Uplift 1=-21 (LC 16), 3=-21 (LC 17)
Max Grav 1=154 (LC 22), 3=154 (LC 23)
31 31FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)Unbalanced roof live loads have been considered for this design.2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)Gable requires continuous bottom chord bearing.6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 21 lb uplift at joint 1 and 21 lb uplift at joint 3.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V09 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:KO8DuFjeoA2xVhGLymDm8nySXIU-oU5I5rF1SqHySRuNyJGjnCXES2iS04DsrUlzPsyf448
DE Job # 86641-W1
Dansco Engineering,
LLC Date: 9/10/2021
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information.
8 12
=3x4
=4x4
=1.5x4 =3x4
1 3
4
9 10
2
T1 T1
B1
ST1
0-5-3
7-9-11
3-5-10
7-4-8
3-10-13
3-10-13
7-9-112-7-80-0-42-3-12Scale = 1:21.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.21 Vert(LL)n/a -n/a 999 MT20 197/144
Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.20 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.09 Horiz(TL)0.00 4 n/a n/a
BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 21 lb FT = 20%
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 7-9-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)1=37/7-9-11, (min. 0-1-8), 3=37/7-9-11, (min. 0-1-8),
4=479/7-9-11, (min. 0-1-8)
Max Horiz 1=-64 (LC 12)
Max Uplift 1=-10 (LC 23), 3=-13 (LC 12), 4=-86 (LC 16)
Max Grav 1=79 (LC 22), 3=79 (LC 23), 4=541 (LC 2)
32 32FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-386/214
NOTES
1)Unbalanced roof live loads have been considered for this design.
2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Exterior(2E) 0-0-6 to 3-0-6, Interior (1) 3-0-6 to 3-11-3, Exterior(2R) 3-11-3 to 6-10-14, Interior (1) 6-10-14 to 7-10-1 zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;
Ce=1.0; Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.5)Gable requires continuous bottom chord bearing.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10 lb uplift at joint 1, 13 lb uplift at joint 3 and 86 lb uplift at joint 4.
8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply DWH - Gramercy-3 Lot 87
V10 1 12107035-12T Valley Job Reference (optional)
Run: 8.42 S Dec 30 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Fri Sep 10 10:34:29 Page: 1
ID:KO8DuFjeoA2xVhGLymDm8nySXIU-oU5I5rF1SqHySRuNyJGjnCXCZ2gZ03msrUlzPsyf448