HomeMy WebLinkAboutGramercy West Carmel IN - Pool Permit Set_2021-04-22 242' - 0"25' - 0"3" MD 2" VAC 2" SK 2" SK 3" RET 2" FILL 6" BACKWASH STANDPIPE 1 2" SK2" RET 2" RET 2" SK 2" FILL 2" VAC 2" SK 2" RET 2" RET 2 2 3 R R R R R RR R R R 3 3 3 3 333 3 3 3" MD 4MD 4MD F 5 6 6 7 V 8 2" VAC 2" SK 3" RET 2" SK 3" MD 9 10 11 12 13 SK SK SKSK A. COORDINATE WITH CONSTRUCTION MANAGER TO SCHEDULE ANY REQUIRED SHUTDOWN AND RESTART OF BUILDING SERVICES. B. THIS CONTRACTOR SHALL COORDINATE THIS WORK WITH ALL OTHER TRADES. C. POOL SHALL MEET THE REQUIREMENTS LISTED IN THE VGBA ANSI/APSP-16 2011. D. ALL PIPING TO BE SCH 40 CPVC. AIR PRESSURE TESTING TO 20 PSIG FOR 24 HOURS E. POOL STRUCTURE: PNEUMATICALLY APPLIED CONCRETE (GUNITE). BOND BEAM WALL TO BE 10" THICK TO BOTTOM OF WALL AND FLOOR TO BE 8" THICK. GUNITE TO ME TRANSIT MIXED, MINIMUM 3500 PSI AT 28 DAYS. F. STEEL LAYOUT: SHALL BE 1/2" DIAMETER BARS AT 12" ON CENTER HORIZONTALLY AND VERTICALLY THROUGHOUT THE ENTIRE POOL. THREE (3) HORIZONTAL BARS AROUND THE PERIMETER OF POOL IN BOND BEAM. G. CIRCULATION SYSTEMS AND EQUIPMENT SHALL CONFORM TO NSF/ANSI 50-2009 AND BEAR THE NSF ENDORSEMENT SEAL, UNLESS THE MANUFACTURER CERTIFIES THE PRODUCTS ARE IN COMPLIANCE WITH NSF/ANSI 50-2009; OR BE OF A MATERIAL SUITABLE FOR WATER SUPPLY PIPING AS SPECIFIED IN INDIANA PLUMBING CODE. H. ALL EXPOSED PIPING SHALL BE COLOR CODED OR PROVIDED WITH PERMANENT LABELS OR TAGS FOR EASY IDENTIFICATION. I. A PRESSURE OR VACUUM GAUGE OR OTHER MEANS OF INDICATING SYSTEM CONDITION SHALL BE PROVIDED IN THE CIRCULATION SYSTEM IN AN ACCESSIBLE LOCATION. PROVIDE AN INDICATOR MEASURING THE RATE OF FLOW THROUGH THE FILTER SYSTEM WITH AN APPROPRIATE RANGE READABLE IN GALLONS PER MINUTE AND ACCURATE WITHIN TEN PERCENT (10%) ACTUAL. J. TIME CLOCKS SHALL NOT BE USED TO REGULATE THE OPERATION OF CIRCULATION SYSTEMS. K. FILTERS SHALL BE DESIGNED AND INSTALLED SO THAT FILTRATION SURFACES CAN BE INSPECTED AND SERVICED. L. ON PRESSURE-TYPE FILTERS, A MEANS SHALL BE PROVIDED TO PERMIT THE RELEASE OF AIR WHICH ENTERS THE FILTER TANK. ANY FILTER INCORPORATING AN AUTOMATIC INTERNAL AIR RELEASE AS ITS PRINCIPAL MEANS OF AIR RELEASE MUST HAVE LIDS WHICH PROVIDE A SLOW AND SAFE RELEASE OF PRESSURE AS A PART OF ITS DESIGN. ANY SEPARATION TANK USED IN CONJUNCTION WITH ANY FILTER TANK MUST HAVE A MANUAL MEANS OF AIR RELEASE OR LID WHICH PROVIDES A SLOW AND SAFE RELEASE OF PRESSURE AS THEY ARE OPENED AS A PART OF ITS DESIGN. M. PRESSURE FILTERS AND SEPARATION TANKS SHALL HAVE OPERATION AND MAINTENANCE INSTRUCTIONS PERMANENTLY INSTALLED ON THE FILTER OR SEPARATION TANK AND SHALL INCLUDE A PRECAUTIONARY STATEMENT WARNING NOT TO START UP THE SYSTEM AFTER MAINTENANCE WITHOUT FIRST OPENING THE AIR RELEASE AND PROPER REASSEMBLY OF THE FILTER AND SEPARATION TANK. THE STATEMENT MUST BE VISIBLE AND NOTICEABLE WITHIN THE AREA OF THE AIR RELEASE. N. PIPING FURNISHED WITH THE FILTER SHALL BE OF SUITABLE MATERIAL CAPABLE OF WITHSTANDING ONE AND ONE-HALF (1 1/2) TIMES THE WORKING PRESSURE. O. FILTER COMPONENTS WHICH REQUIRE SERVICING SHALL BE ACCESSIBLE FOR INSPECTION AND REPAIR WHEN INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. P. PUMPS AND MOTORS MUST BE ACCESSIBLE FOR INSPECTION AND SERVICE AND SHALL HAVE REMOVABLE STRAINERS. Q. ALL PUMP MOTORS SHALL HAVE AS A MINIMUM AN OPEN, DRIP-PROOF ENCLOSURE AND BE CONSTRUCTED ELECTRICALLY AND MECHANICALLY SO THEY WILL PERFORM SATISFACTORILY UNDER THE CONDITIONS OF LOAD AND ENVIRONMENT NORMALLY ENCOUNTERED IN SWIMMING POOL INSTALLATIONS. R. ALL PUMP MOTORS SHALL HAVE THERMAL OR CURRENT OVERLOAD PROTECTION, EITHER BUILT-IN OR IN THE LINE STARTER, TO PROVIDE LOCKED ROTOR AND RUNNING PROTECTION. S. THE MOTOR FRAME SHALL CONTAIN ADEQUATE PROVISIONS FOR PROPER GROUNDING. T. PRESSURE AND VACUUM GAUGES SHALL BE INSTALLED ON ALL SWIMMING POOLS AND THE VACUUM GAUGE SHALL BE INSTALLED AS CLOSE TO THE PUMP SUCTION INLET AS POSSIBLE AND STILL MAINTAIN AN ACCURATE READING; AND PRESSURE GAUGE SHALL BE INSTALLED ON THE FACE PIPING AHEAD OF THE FILTER OR ON THE TOP OF THE FILTER IN THE AREA OF GREATEST FILTER PRESSURE. U. WHERE A MECHANICAL PUMP SEAL IS PROVIDED, COMPONENTS OF THE SEAL MUST BE CORROSION-RESISTING AND CAPABLE OF OPERATING UNDER CONDITIONS NORMALLY ENCOUNTERED IN SWIMMING POOL OPERATION. V. WASTE WATER SHALL BE DISCHARGED TO A POINT IN ACCORDANCE WITH INDIANA ADMINISTRATIVE CODE 675 IAC 20-2-23, THE RULES OF THE WATER POLLUTION CONTROL BOARD, THROUGH AN APPROVED AIRGAP OR OTHER MEANS IN ACCORDANCE WITH INDIANA STATE PLUMBING CODE. W. DISINFECTANT EQUIPMENT AND CHEMICAL FEEDERS SHALL BE CAPABLE OF AUTOMATICALLY PROVIDING A CONTINUOUS RESIDUAL CHEMICAL EFFECT IN ACCORDANCE WITH 675 IAC 20-2-24. ALL SUCH EQUIPMENT SHALL BE OF AN APPROVED TYPE AND SHALL BE INSTALLED DOWNSTREAM (ON PRESSURE SIDE OF PUMP) FROM THE PUMP AND WIRED SO THEY WILL NOT OPERATE UNLESS THE FILTER PUMP IS OPERATING. POWER TO SHUT-OFF PUMP WHILE PUMP IS OFF. Z. POOL FINISH: BRITE WHITE AA. POOL INFORMATION: POOL VOLUME: 31,416 GALLONS TURNOVER: 6 HOURS REQUIRED GPM: 87.26 GPM RATE OF FILTRATION GPM: 106 GPM RATE OF FILTRATION: 15.01 GPM/SQ.FT. PUMP CAPACITY MAX GPM: 105 GPM TOTAL DYNAMIC HEAD: 60 FT. GENERAL NOTES CEN GINEERLANOISSORPEFIAN ADNI I ETRED SGERNo. PE11400027 STATE OF AAMERO N T.YAMAS HI T........................................................ . . ...... .................................THIS DRAWING AND ALL INFORMATION ON IT ISTHE PROPERTY OF DEEM MECHANICAL &ELECTRICAL, LLC. IT IS CONFIDENTIAL AND IT'SSUBMISSION OR DISTRIBUTION TO MEETOFFICIAL REGULATORY REQUIREMENTS OR FOROTHER PURPOSES IN CONNECTION WITH THISPROJECT IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF DEEMMECHANICAL & ELECTRICAL, LLC. COMMON LAWCOPYRIGHT OR OTHER RESERVED RIGHTS. THISDRAWING NOR ANY PART OF IT MAY NOT BEREPRODUCED, COPIED, EXHIBITED, ORDISTRIBUTED TO OTHERS NOR MAY ANY ARTICLEOR ITEM BE FABRICATED OR ASSEMBLED FROMTHIS DRAWING WITHOUT WRITTEN CONSENTFROM DEEM MECHANICAL & ELECTRICAL, LLC.DRAWING No. : DEEM MECHANICAL & ELECTRICAL, LLC. RESERVES THE RIGHT TO REVISE THE DESIGN OF THE ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDING THE CHANGES MEET THE DESIGN/BUILD SPECIFICATIONS FOR THIS PROJECT. DRAWN BY : DATE : SCALE : PROJECT NO. :6831 East 32nd Street, Suite 300 Indianapolis, IN 46226Office: 317.842.7662www.deemfirst.comPROJECT NAME :DRAWING TITLE :CERTIFIED BY : BASE SHEETS PROVIDED BY : ORIGINAL DRAWING IS : 24"x36"VICTORY SURFACES POOL DIVISIONAs indicated 4/22/2021 11:19:42 AMAuthor 04/19/2021 21014685 Lagerfield DriveCarmel, IN 46032POOL PIPING LAYOUT PLANBuckingham Construction Corp.GRAMERCY WESTPL201 1/4" = 1'-0"1 POOL PIPING PLAN # PLAN NOTES 1 REFER TO PL200 FOR BALANCE OF INFORMATION FOR POOL EQUIPMENT ROOM. 2 POOL UNDERWATER LED LIGHT. POWER AND ELECTRICAL CONDUIT BY DIV. 26. UNDERWATER LIGHTING SHALL PROVIDE AT LEAST FIVE-TENTHS (0.5) WATT OR EIGHT AND THIRTY-FIVE HUNDREDS (8.35) LUMENS PER SQUARE FOOT OF WATER SURFACE. LIGHTING OR LIGHTS FOR POOL DECK CONTROLS SHALL NOT BE ACCESSIBLE TO THE PUBLIC. 3 INLETS SHALL BE LOCATED TWELVE (12) INCHES BELOW THE WATER LINE AN NO HIGHER THEN THE WATERLINE. INLETS SHALL BE TWELVE (12) INCHES BELOW THE MIDPOINT ON THE SKIMMER THROAT. 4 OUTLET DRAIN COVERS AND GRATES SHALL BE INSTALLED IN SUCH AWAY THAT THEY CANNOT BE REMOVED WITHOUT THE USE OF TOOLS. MAIN OUTLETS SHALL CONFORM TO THE REQUIREMENTS OF ASME A112.19.8-2007. 5 SIDEWALL POOL WATER FILL WITH GRATE INSERT. 6 STAINLESS STEEL HANDRAIL 7 STAINLESS STEEL LADDER. 8 SIDEWALL VACUUM INLET WITH SELF-CLOSING AND SELF-LATCH COVER. VGB CERTIFIED. 9 3" MAIN DRAIN UP. 10 2" VACUUM UP. 11 2" SKIMMER UP. 12 3" RETURN FROM ABOVE. 13 2" POOL FILL FROM ABOVE.REVISION SCHEDULENo. DESCRIPTION DATE09/29/21