A. COORDINATE WITH CONSTRUCTION MANAGER TO SCHEDULE ANY
REQUIRED SHUTDOWN AND RESTART OF BUILDING SERVICES.
B. THIS CONTRACTOR SHALL COORDINATE THIS WORK WITH ALL OTHER
TRADES.
C. POOL SHALL MEET THE REQUIREMENTS LISTED IN THE VGBA
ANSI/APSP-16 2011.
D. ALL PIPING TO BE SCH 40 CPVC. AIR PRESSURE TESTING TO 20 PSIG
FOR 24 HOURS
E. POOL STRUCTURE: PNEUMATICALLY APPLIED CONCRETE (GUNITE).
BOND BEAM WALL TO BE 10" THICK TO BOTTOM OF WALL AND
FLOOR TO BE 8" THICK. GUNITE TO ME TRANSIT MIXED, MINIMUM
3500 PSI AT 28 DAYS.
F. STEEL LAYOUT: SHALL BE 1/2" DIAMETER BARS AT 12" ON CENTER
HORIZONTALLY AND VERTICALLY THROUGHOUT THE ENTIRE POOL.
THREE (3) HORIZONTAL BARS AROUND THE PERIMETER OF POOL IN
BOND BEAM.
G. CIRCULATION SYSTEMS AND EQUIPMENT SHALL CONFORM TO NSF/ANSI
50-2009 AND BEAR THE NSF ENDORSEMENT SEAL, UNLESS THE
MANUFACTURER CERTIFIES THE PRODUCTS ARE IN COMPLIANCE WITH
NSF/ANSI 50-2009; OR BE OF A MATERIAL SUITABLE FOR WATER
SUPPLY PIPING AS SPECIFIED IN INDIANA PLUMBING CODE.
H. ALL EXPOSED PIPING SHALL BE COLOR CODED OR PROVIDED WITH
PERMANENT LABELS OR TAGS FOR EASY IDENTIFICATION.
I. A PRESSURE OR VACUUM GAUGE OR OTHER MEANS OF INDICATING
SYSTEM CONDITION SHALL BE PROVIDED IN THE CIRCULATION SYSTEM
IN AN ACCESSIBLE LOCATION. PROVIDE AN INDICATOR MEASURING THE
RATE OF FLOW THROUGH THE FILTER SYSTEM WITH AN APPROPRIATE
RANGE READABLE IN GALLONS PER MINUTE AND ACCURATE WITHIN
TEN PERCENT (10%) ACTUAL.
J. TIME CLOCKS SHALL NOT BE USED TO REGULATE THE OPERATION OF
CIRCULATION SYSTEMS.
K. FILTERS SHALL BE DESIGNED AND INSTALLED SO THAT FILTRATION
SURFACES CAN BE INSPECTED AND SERVICED.
L. ON PRESSURE-TYPE FILTERS, A MEANS SHALL BE PROVIDED TO
PERMIT THE RELEASE OF AIR WHICH ENTERS THE FILTER TANK. ANY
FILTER INCORPORATING AN AUTOMATIC INTERNAL AIR RELEASE AS ITS
PRINCIPAL MEANS OF AIR RELEASE MUST HAVE LIDS WHICH PROVIDE
A SLOW AND SAFE RELEASE OF PRESSURE AS A PART OF ITS DESIGN.
ANY SEPARATION TANK USED IN CONJUNCTION WITH ANY FILTER TANK
MUST HAVE A MANUAL MEANS OF AIR RELEASE OR LID WHICH
PROVIDES A SLOW AND SAFE RELEASE OF PRESSURE AS THEY ARE
OPENED AS A PART OF ITS DESIGN.
M. PRESSURE FILTERS AND SEPARATION TANKS SHALL HAVE OPERATION
AND MAINTENANCE INSTRUCTIONS PERMANENTLY INSTALLED ON THE
FILTER OR SEPARATION TANK AND SHALL INCLUDE A PRECAUTIONARY
STATEMENT WARNING NOT TO START UP THE SYSTEM AFTER
MAINTENANCE WITHOUT FIRST OPENING THE AIR RELEASE AND PROPER
REASSEMBLY OF THE FILTER AND SEPARATION TANK. THE STATEMENT
MUST BE VISIBLE AND NOTICEABLE WITHIN THE AREA OF THE AIR
RELEASE.
N. PIPING FURNISHED WITH THE FILTER SHALL BE OF SUITABLE MATERIAL
CAPABLE OF WITHSTANDING ONE AND ONE-HALF (1 1/2) TIMES THE
WORKING PRESSURE.
O. FILTER COMPONENTS WHICH REQUIRE SERVICING SHALL BE
ACCESSIBLE FOR INSPECTION AND REPAIR WHEN INSTALLED
ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.
P. PUMPS AND MOTORS MUST BE ACCESSIBLE FOR INSPECTION AND
SERVICE AND SHALL HAVE REMOVABLE STRAINERS.
Q. ALL PUMP MOTORS SHALL HAVE AS A MINIMUM AN OPEN,
DRIP-PROOF ENCLOSURE AND BE CONSTRUCTED ELECTRICALLY AND
MECHANICALLY SO THEY WILL PERFORM SATISFACTORILY UNDER THE
CONDITIONS OF LOAD AND ENVIRONMENT NORMALLY ENCOUNTERED IN
SWIMMING POOL INSTALLATIONS.
R. ALL PUMP MOTORS SHALL HAVE THERMAL OR CURRENT OVERLOAD
PROTECTION, EITHER BUILT-IN OR IN THE LINE STARTER, TO PROVIDE
LOCKED ROTOR AND RUNNING PROTECTION.
S. THE MOTOR FRAME SHALL CONTAIN ADEQUATE PROVISIONS FOR
PROPER GROUNDING.
T. PRESSURE AND VACUUM GAUGES SHALL BE INSTALLED ON ALL
SWIMMING POOLS AND THE VACUUM GAUGE SHALL BE INSTALLED AS
CLOSE TO THE PUMP SUCTION INLET AS POSSIBLE AND STILL
MAINTAIN AN ACCURATE READING; AND PRESSURE GAUGE SHALL BE
INSTALLED ON THE FACE PIPING AHEAD OF THE FILTER OR ON THE
TOP OF THE FILTER IN THE AREA OF GREATEST FILTER PRESSURE.
U. WHERE A MECHANICAL PUMP SEAL IS PROVIDED, COMPONENTS OF
THE SEAL MUST BE CORROSION-RESISTING AND CAPABLE OF
OPERATING UNDER CONDITIONS NORMALLY ENCOUNTERED IN SWIMMING
POOL OPERATION.
V. WASTE WATER SHALL BE DISCHARGED TO A POINT IN ACCORDANCE
WITH INDIANA ADMINISTRATIVE CODE 675 IAC 20-2-23, THE RULES
OF THE WATER POLLUTION CONTROL BOARD, THROUGH AN APPROVED
AIRGAP OR OTHER MEANS IN ACCORDANCE WITH INDIANA STATE
PLUMBING CODE.
W. DISINFECTANT EQUIPMENT AND CHEMICAL FEEDERS
SHALL BE CAPABLE OF AUTOMATICALLY
PROVIDING A CONTINUOUS RESIDUAL CHEMICAL EFFECT IN
ACCORDANCE WITH 675 IAC 20-2-24. ALL SUCH EQUIPMENT SHALL
BE OF AN APPROVED TYPE AND SHALL BE INSTALLED DOWNSTREAM
(ON PRESSURE SIDE OF PUMP) FROM THE PUMP AND WIRED SO THEY
WILL NOT OPERATE UNLESS THE FILTER PUMP IS OPERATING. POWER
TO SHUT-OFF PUMP WHILE PUMP IS OFF.
Z. POOL FINISH: BRITE WHITE
AA. POOL INFORMATION:
POOL VOLUME: 31,416 GALLONS
TURNOVER: 6 HOURS
REQUIRED GPM: 87.26 GPM
RATE OF FILTRATION GPM: 106 GPM
RATE OF FILTRATION: 15.01 GPM/SQ.FT.
PUMP CAPACITY MAX GPM: 105 GPM
TOTAL DYNAMIC HEAD: 60 FT.
GENERAL NOTES
CEN GINEERLANOISSORPEFIAN ADNI
I ETRED
SGERNo.
PE11400027
STATE OF AAMERO N T.YAMAS
HI
T........................................................
.
.
...... .................................THIS DRAWING AND ALL INFORMATION ON IT ISTHE PROPERTY OF DEEM MECHANICAL &ELECTRICAL, LLC. IT IS CONFIDENTIAL AND IT'SSUBMISSION OR DISTRIBUTION TO MEETOFFICIAL REGULATORY REQUIREMENTS OR FOROTHER PURPOSES IN CONNECTION WITH THISPROJECT IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF DEEMMECHANICAL & ELECTRICAL, LLC. COMMON LAWCOPYRIGHT OR OTHER RESERVED RIGHTS. THISDRAWING NOR ANY PART OF IT MAY NOT BEREPRODUCED, COPIED, EXHIBITED, ORDISTRIBUTED TO OTHERS NOR MAY ANY ARTICLEOR ITEM BE FABRICATED OR ASSEMBLED FROMTHIS DRAWING WITHOUT WRITTEN CONSENTFROM DEEM MECHANICAL & ELECTRICAL, LLC.DRAWING No. :
DEEM MECHANICAL & ELECTRICAL, LLC.
RESERVES THE RIGHT TO REVISE THE DESIGN
OF THE ELECTRICAL AND/OR MECHANICAL
SYSTEMS PROVIDING THE CHANGES MEET
THE DESIGN/BUILD SPECIFICATIONS FOR THIS
PROJECT.
DRAWN BY :
DATE
:
SCALE :
PROJECT NO. :6831 East 32nd Street, Suite 300 Indianapolis, IN 46226Office: 317.842.7662www.deemfirst.comPROJECT NAME :DRAWING TITLE :CERTIFIED BY :
BASE SHEETS PROVIDED BY :
ORIGINAL DRAWING IS : 24"x36"VICTORY SURFACES POOL DIVISIONAs indicated
4/22/2021 11:19:42 AMAuthor
04/19/2021
21014685 Lagerfield DriveCarmel, IN 46032POOL PIPING LAYOUT PLANBuckingham Construction Corp.GRAMERCY WESTPL201
1/4" = 1'-0"1 POOL PIPING PLAN
# PLAN NOTES
1 REFER TO PL200 FOR BALANCE OF INFORMATION FOR POOL
EQUIPMENT ROOM.
2 POOL UNDERWATER LED LIGHT. POWER AND ELECTRICAL CONDUIT
BY DIV. 26. UNDERWATER LIGHTING SHALL PROVIDE AT LEAST
FIVE-TENTHS (0.5) WATT OR EIGHT AND THIRTY-FIVE HUNDREDS
(8.35) LUMENS PER SQUARE FOOT OF WATER SURFACE. LIGHTING
OR LIGHTS FOR POOL DECK CONTROLS SHALL NOT BE ACCESSIBLE
TO THE PUBLIC.
3 INLETS SHALL BE LOCATED TWELVE (12) INCHES BELOW THE
WATER LINE AN NO HIGHER THEN THE WATERLINE. INLETS SHALL
BE TWELVE (12) INCHES BELOW THE MIDPOINT ON THE SKIMMER
THROAT.
4 OUTLET DRAIN COVERS AND GRATES SHALL BE INSTALLED IN
SUCH AWAY THAT THEY CANNOT BE REMOVED WITHOUT THE USE
OF TOOLS. MAIN OUTLETS SHALL CONFORM TO THE
REQUIREMENTS OF ASME A112.19.8-2007.
5 SIDEWALL POOL WATER FILL WITH GRATE INSERT.
6 STAINLESS STEEL HANDRAIL
7 STAINLESS STEEL LADDER.
8 SIDEWALL VACUUM INLET WITH SELF-CLOSING AND SELF-LATCH
COVER. VGB CERTIFIED.
9 3" MAIN DRAIN UP.
10 2" VACUUM UP.
11 2" SKIMMER UP.
12 3" RETURN FROM ABOVE.
13 2" POOL FILL FROM ABOVE.REVISION SCHEDULENo. DESCRIPTION DATE09/29/21