M100.0
CL (D) (E) (E) N.I.C. N.I.C. T ST VENTILATION (HVAC) RECTANGULAR DUCT WITH ACOUSTIC LINING* AIR FLOW ARROW EXTERIOR DUCT TREATMENT* FLEXIBLE DUCT ELBOW TURN, SUPPLY DOWN. APPLIES TO RECT., ROUND AND OVAL 18"x12" 18"x12" 18"x12" RECTANGULAR DUCT AND SIZE* 18"ø ROUND DUCT AND SIZE* 18"x12" 18"x12" 18"ø 18"x12"ø FLAT OVAL DUCT AND SIZE*18"x12"ø DUCT SECTION, SUPPLY AIR. SIZE* IS HORIZONTAL DIM. x VERTICAL DIM. APPLIES TO RECT., ROUND AND OVAL30"x12" DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL DUCT SECTION, RETURN AIR. APPLIES TO RECT., ROUND AND OVAL DUCT SECTION, EXHAUST AIR. APPLIES TO RECT., ROUND AND OVAL ELBOW TURN, OUTSIDE AIR DOWN. APPLIES TO RECT., ROUND AND OVAL ELBOW TURN, RETURN DOWN. APPLIES TO RECT., ROUND AND OVAL ELBOW TURN, EXHAUST DOWN. APPLIES TO RECT., ROUND AND OVAL CHANGE IN DUCT ELEVATION RISING IN DIRECTION INDICATED CHANGE IN DUCT ELEVATION DROPPING IN DIRECTION INDICATED END CAP UP DN ELBOW, RECTANGULAR, SMOOTH RADIUS WITH SPLITTER VANES (0.25 R/W DEFAULT) ELBOW, RECTANGULAR, SMOOTH RADIUS WITHOUT VANES (1.5 R/W DEFAULT) ELBOW, ROUND, SMOOTH RADIUS (1.5 R/W DEFAULT) MITERED ELBOW, RECTANGULAR, WITH TURNING VANES RECTANGULAR TO ROUND TRANSITION DUCT ACCESS DOOR (TOP, SIDE, BOTTOM) AD AD AD FLEXIBLE CONNECTION FC BDD BACKDRAFT DAMPER MANUAL DAMPER MOTORIZED DAMPER FIRE DAMPER SMOKE DAMPER SMOKE AND FIRE DAMPER DUCT SILENCER CONTROL DEVICE (REFER TO CONTROLS LEGEND) AIR FLOW MEASURING STATION (REFER TO CONTROLS LEGEND) AIR OUTLET OR INLET TAG (REFER TO SCHEDULE) RECTANGULAR DIFFUSER, SUPPLY. OPTIONAL ARROWS SHOW THE FLOW DIRECTION. RECTANGULAR REGISTER OR GRILLE, RETURN RECTANGULAR REGISTER OR GRILLE, EXHAUST ROUND DIFFUSER, SUPPLY LINEAR DIFFUSER SIDEWALL REGISTER OR GRILLE, SUPPLY SIDEWALL GRILLE, RETURN OR EXHAUST UNDERCUT DOOR DOOR GRILLE OR LOUVER TRANSFER GRILLE OR LOUVER COIL (REFER TO CONTROLS LEGEND) EQUIPMENT TAG RADIATION HEATING TAG (REFER TO SCHEDULE) M X ID-# QUANTITY TYPE SIZE (IN.) VOLUME (CFM) - - - - VENTILATION (HVAC) QUANTITY TYPE LENGTH (FT) CAPACITY (MBH) - - - - UC * NOTE: ALL DUCT SIZES ARE INTERIOR, FREE DIMENSIONS (ALWAYS WIDTH X HEIGHT IN FLOOR PLAN AND SECTION) MECHANICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS NORTH ARROW ? DRAWING REVISION N 0000 XROOM TAG KEY NOTE TAG CIRCULAR BREAK SYMBOL CENTER LINE CIRCLE BREAK SYMBOL GRID BUBBLE AND LINE GENERAL SYMBOLS POINT OF CONNECTION OF NEW TO EXISTING SYSTEM DEMOLITION EXISTING POINT OF DISCONNECTION OF DEMOLITION FROM EXISTING NEW WORK CAP OFF EXISTING XX COMMON WORK RESULTS FOR MECHANICAL 1. ALL WORK SHALL BE IN COMPLIANCE WITH THE DRAWINGS AND THE GENERAL PROVISIONS OF THE CONTRACT INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS. 2. THE DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL LOCATION AND ARRANGEMENT OF THE EQUIPMENT AND PIPING. THE CONTRACTOR SHALL VISIT THE SITE AND FIELD VERIFY CONDITIONS FOR INSTALLATION PRIOR TO BID SUBMISSION. IF A DISCREPANCY EXISTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERATIONAL SYSTEM BASED ON THE DESIGN INTENT OF THE DRAWINGS AND SPECIFICATIONS. 3. PROVIDE SUBMITTALS ON ALL MATERIALS AND EQUIPMENT TO BE INSTALLED FOR REVIEW BY THE ARCHITECT AND ENGINEER. ALL MATERIALS AND EQUIPMENT SHALL BE PER THE SPECIFICATIONS AND DRAWINGS AND SHALL BE PROVIDED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. A. SHOP DRAWINGS B. PRODUCT DATA SHEETS C. SAMPLES D. MANUFACTURERS INSTRUCTIONS E. MAINTENANCE DATA F. WARRANTY 4. SUBMITTAL DATA SHALL BE SUBMITTED AFTER CONTRACTS HAVE BEEN AWARDED AND PRIOR TO FABRICATION. INSTALLATION OF MATERIAL REQUIRING REVIEW AND APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO SUBMITTALS SHALL BE AT CONTRACTORS RISK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL QUANTITIES AND CONFIGURATIONS OF DEVICES AND EQUIPMENT FOR A COMPLETE AND OPERATIONAL EQUIPMENT REGARDLESS OF INCOMPLETE OR INACCURATE SUBMITTALS. 5. PROVIDE AND SUBMIT AS-BUILT DOCUMENTS THAT INCLUDE ACCURATE ROUTINGS OF ALL UNDERGROUND WORK AND ALL ABOVE GROUND PIPING AND DUCTWORK. 6. PROVIDE BOUND OPERATIONAL AND MAINTENANCE MANUALS CONTAINING THE EQUIPMENT DATA, MANUFACTURERS INSTALLATION, OPERATING, MAINTENANCE, REPAIR PARTS MANUAL FOR EACH SYSTEM COMPONENT, TEST REPORTS, AND AS-BUILT TEMPERATURE CONTROL DIAGRAMS. 7. VOLUNTARY ALTERNATES MAY BE SUBMITTED FOR CONSIDERATION ON THE PROPOSAL, WITH LISTED ADDITION OR DEDUCTIONS TO THE BASE BID, BUT WILL NOT AFFECT THE AWARDING OF THE CONTRACT. THE BASE BID MUST BE IN ACCORDANCE WITH THE MATERIALS AND PRODUCTS SPECIFIED. 8. OBTAIN AND PAY FOR ALL PERMITS (TEMPORARY AND PERMANENT), FEES, AND INSPECTIONS AS REQUIRED BY ANY APPLICABLE LAWS AND ORDINANCES. POST SUCH PERMITS AND INSPECTION CERTIFICATES IN A PROMINENT PLACE ADJACENT TO THE WORK. DELIVER ALL CERTIFICATES OF FINAL INSPECTION OR APPROVAL TO THE ARCHITECT/ENGINEER. DO NOT COVER ANY CONCEALED WORK UNTIL FINAL INSPECTION HAS BEEN MADE AND APPROVAL CERTIFICATES OBTAINED. 9. DELIVER DUCTWORK, PIPES AND TUBES WITH FACTORY-APPLIED END CAPS. MAINTAIN END CAPS THROUGH SHIPPING, STORAGE, AND HANDLING TO PREVENT DUCTWORK AND PIPE END DAMAGE AND TO PREVENT ENTRANCE OF DIRT, DEBRIS, AND MOISTURE. STORE PLASTIC PIPES PROTECTED FROM DIRECT SUNLIGHT. SUPPORT PIPING AND DUCTWORK TO PREVENT SAGGING AND BENDING. 10. PROVIDE ALL CUTTING, PATCHING, AND RESTORATION OF WALLS, FLOORS, AND PARTITIONS AS REQUIRED TO COMPLETE THE MECHANICAL SCOPE OF WORK. ALL ROOF WORK SHALL BE COORDINATED AND PAID FOR BY THE CONTRACTOR TO MAINTAIN EXISTING WARRANTIES. 11. PROVIDE A UL CLASSIFIED FIRE STOPPING SYSTEM FOR MECHANICAL PENETRATIONS THROUGH RATED WALL AND FLOORS TO MAINTAIN THE FIRE RATING. 12. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO STUDY THE ARCHITECTURAL, STRUCTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS, CONFERRING WITH THE VARIOUS TRADES INVOLVED AND CHECKING WITH THE SUPPLIER OF EQUIPMENT IN ORDER TO PROPERLY ROUGH-IN ALL EQUIPMENT. 13. ALL MATERIAL AND EQUIPMENT SHALL BE NEW AND OF THE BEST QUALITY USED FOR THE PURPOSE IN GOOD COMMERCIAL PRACTICE. THE MATERIAL AND EQUIPMENT MUST MEET THE APPROVAL OF STATE AND LOCAL CODES IN THE AREA IT IS BEING USED. 14. NO MATERIALS CONTAINING ASBESTOS IN ANY FORM SHALL BE ALLOWED. NO SOLDER OR FLUX CONTAINING LEAD SHALL BE USED. ALL VALVES AND FIXTURES SHALL COMPLY WITH NSF LEAD-FREE REQUIREMENTS. 15. CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED BY THEM OR THEIR SUBCONTRACTORS TO BE FREE FROM DEFECT IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF THE WORK, UNLESS A LONGER PERIOD IS STIPULATED UNDER A SPECIFIC SECTION. CONTRACTOR SHALL REPAIR OR REPLACE AT NO ADDITIONAL COST TO THE OWNER, ANY MATERIAL OR EQUIPMENT DEVELOPING DEFECTS AND SHALL ALSO MAKE GOOD ANY DAMAGE CAUSED BY SUCH DEFECTS OR THE CORRECTION OF DEFECTS. REPAIRS OR REPLACEMENTS SHALL BEAR ADDITIONAL GUARANTEE, AS ORIGINALLY CALLED FOR, AND DATED FROM THE FINAL ACCEPTANCE OF THE REPAIR OR REPLACEMENT. THIS REQUIREMENT SHALL BE BINDING EVEN THOUGH IT WILL EXCEED PRODUCT GUARANTEES NORMALLY FURNISHED BY SOME MANUFACTURERS. CONTRACTOR SHALL SUBMIT HIS OWN AND EACH EQUIPMENT MANUFACTURERS WRITTEN CERTIFICATES, WARRANTING THAT EACH ITEM OF THE EQUIPMENT FURNISHED COMPLIES WITH ALL REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. NOTE THAT GUARANTEE SHALL RUN FROM DATE OF FINAL ACCEPTANCE OF THE WORK, NOT FROM THE DATE OF INSTALLATION OF A DEVICE OR PIECE OF EQUIPMENT. 16. PROVIDE ONE YEAR WARRANTY ON ALL LABOR AND MATERIALS UNLESS NOTED OTHERWISE. 17. MECHANICAL CONTRACTOR SHALL NOT KNOWINGLY INSTALL WORK THAT IS IN ERROR. 18. CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING PROPOSAL AND EXAMINE AND VERIFY EXISTING CONDITIONS. ADDITIONAL CHARGES WILL NOT BE ALLOWED DUE TO FAILURE TO COMPLETE SITE VISIT OR TO INCLUDE NECESSARY MATERIALS AND LABOR TO COMPLETE THE WORK. PROPOSAL BEING SUBMITTED IMPLIES SITE VISIT HAS OCCURRED AND CONTRACTOR UNDERSTANDS THE CONDITIONS WHICH THE WORK WILL BE CONDUCTED. 19. ANY CONFLICT WITHIN THE DOCUMENTS SHALL BE INCLUDED WITH THE HIGHEST COST. 20. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY THAT SYSTEMS CAN BE INSTALLED AS DESIGNED WITHOUT TRAPPING OR INTERFERING WITH COLUMNS, BEAMS, PIPING, FIXTURES, ETC. NOTIFY THE ENGINEER OF ANY NECESSARY MAJOR DEVIATION FOR ADJUSTMENT, AT NO INCREASE IN CONTRACT PRICE. UPON DETERMINATION OF EQUIPMENT TO BE PROVIDED FOR THE JOB, THE CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS WITH ALL OTHER TRADES. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO CHANGE AS NECESSARY (THROUGH THE ENGINEER) ALL REQUIRED OPENINGS SUCH THAT CURBS, ELECTRICAL SUPPORT STEEL, ETC. WILL FIT THE EQUIPMENT. ANY ADDITIONAL COSTS WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IF ADDITIONAL WIRING, PIPING CONTROLS, ETC. ARE REQUIRED FOR EQUIPMENT, THIS CONTRACTOR SHALL INCLUDE THE COST IN THEIR PRICE. DIMENSIONS, ELEVATIONS, AND RELATIVE LOCATIONS OF EXISTING EQUIPMENT, PIPES, DUCTS, FIXTURES, ETC. AS SHOWN ON DRAWINGS ARE TAKEN FROM AS- BUILT AND RECORD DRAWINGS AND ARE DEEMED RELIABLE AS GENERAL LAYOUT IS CONCERNED. THESE DIMENSIONS SHALL NOT BE USED FOR LAYOUT DRAWINGS FOR DETAILING OF COMPONENTS. THE CONTRACTOR SHALL PROVIDE ALL MEASUREMENTS, DETERMINATION OF EXACT ELEVATION OF LOCATIONS, ASCERTAINING ACCURACY OF ALL GIVEN ELEVATIONS AND DIMENSIONS TO INSURE PROPER COORDINATION OF ALL EQUIPMENT, DUCTWORK, PIPING, ETC. 21. CONTRACTOR SHALL PROVIDE FIELD TESTING, CHECK-OUT AND SYSTEM DEMONSTRATION TO OWNER TO ASSURE PROPER PERFORMANCE AND ADJUSTMENT OF ITEMS PROVIDED UNDER THE CONTRACT. REMOVE ALL DEBRIS CREATED BY THE CONSTRUCTION WORK AND CLEAN ALL EQUIPMENT, AIR DEVICES, ETC. INSIDE AND OUTSIDE. PROVIDE HARDBOUND BINDER WHICH INCLUDES COPIES OF EACH SHOP DRAWING, PREVENTATIVE MAINTENANCE PROCEDURES, OPERATION AND INSTRUCTION MANUALS, LITERATURE SUPPLIED WITH EQUIPMENT, AND A LIST OF ALL CONTRACTORS PURCHASE ORDER WITH SUPPLIERS, NAMES, ADDRESSES AND PHONE NUMBERS, FOR ALL MATERIALS. PROVIDE AT LEAST 2 HOURS OF INSTRUCTION TO PERSONNEL SELECTED BY THE OWNER, TO FAMILIARIZE THEM WITH THE LOCATION OF SIGNIFICANT EQUIPMENT, TRAIN THEM ON EQUIPMENT FUNCTIONS, REVIEW MAINTENANCE PROCEDURES AND COORDINATE INFORMATION AVAILABLE IN THE CLOSE-OUT BINDER. HANGERS AND SUPPORTS 1. HANGER AND SUPPORT INSTALLATION SHALL COMPLY WITH MSS SP-69 AND MSS SP-89 (MANUFACTURERS STANDARDIZATION SOCIETY FOR THE VALVE AND FITTINGS INDUSTRY INC). 2. THE USE OF C CLAMPS AND BEAM CLAMPS OF A C PATTERN AND ANY MODIFICATION THEREOF IS PROHIBITED FOR 2-1/2 INCHES AND LARGER. 3. STEEL PIPE HANGERS AND SUPPORTS: COMPLY WITH MSS SP-58, TYPES 1 THROUGH 58, FACTORY FABRICATED COMPONENTS. STEEL PIPE HANGERS AND SUPPORTS SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: B-LINE SYSTEMS, GRINNELL CORP., ERICO/MICHIGAN HANGER COMPANY, PHD MANUFACTURING, OR PHS INDUSTRIES. 4. TRAPEZE PIPE HANGERS: COMPLY WITH MSS SP-69, TYPE 59, SHOP- OR FIELD-FABRICATED PIPE- SUPPORT ASSEMBLY MADE FROM STRUCTURAL-STEEL SHAPES WITH MSS SP-58 HANGER RODS, NUTS, SADDLES, AND U-BOLTS. 5. METAL FRAMING SYSTEMS: COMPLY WITH MFMA-3 SHOP- OR FIELD-FABRICATED PIPE-SUPPORT ASSEMBLY MADE OF STEEL CHANNELS AND OTHER COMPONENTS WITH FACTORY STANDARD FINISH OR COPPER PLATED WHEN SUPPORT ELEMENTS WILL BE IN CONTACT WITH COPPER PIPING. METAL FRAMING SYSTEMS SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: B-LINE SYSTEMS, ERICO/MICHIGAN HANGER COMPANY, OR UNISTRUT CORPORATION. 6. THERMAL-HANGER SHIELD INSERTS: 100-PSIG-MINIMUM, COMPRESSIVE-STRENGTH INSULATION INSERT ENCASED IN SHEET METAL SHIELD. INSULATION INSERT MATERIAL FOR COLD WATER PIPING SHALL BE WATER-REPELLENT TREATED, ASTM C 533, TYPE 1 CALCIUM SILICATE OR ASTM C522, TYPE II CELLULAR GLASS WITH VAPOR BARRIER. INSULATION INSERT MATERIAL FOR HOT WATER PIPING SHALL BE WATER-REPELLENT TREATED, ASTM C 533, TYPE 1 CALCIUM SILICATE OR ASTM C522, TYPE II CELLULAR GLASS. TRAPEZE AND CLAMPED SYSTEMS SHALL HAVE INSERT AND SHIELD COVER ENTIRE CIRCUMFERENCE OF THE PIPE. CLEVIS AND BAND HANGERS SYSTEMS SHALL HAVE INSERT AND SHIELD COVER 180 DEGREES OF THE PIPE. THE INSERT LENGTH SHALL EXTEND TWO INCHES BEYOND THE SHEET METAL SHIELD. 7. MECHANICAL-EXPANSION ANCHORS SHALL BE INSERT-WEDGE-TYPE STAINLESS STEEL, FOR USE IN HARDENED PORTLAND CEMENT CONCRETE WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED. FASTENER SYSTEMS SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: B-LINE SYSTEMS, HILTI, MKT FASTENING, OR POWERS FASTENERS. IDENTIFICATION FOR MECHANICAL 1. IDENTIFICATION SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: BRADY CO, BRAMER, CRAFTMARK, EMED, MARKING SERVICES, OR SETON NAME PLATE CORP. 2. NEW OR RENOVATED PIPING SYSTEMS AND EQUIPMENT SHALL HAVE IDENTIFICATION MARKERS. 3. PIPING SYSTEMS SHALL HAVE PRE-TENSIONED, SEMI-RIGID PLASTIC PIPE LABELS FORMED TO COVER FULL CIRCUMFERENCE OF PIPE, PREPRINTED AND COLOR-CODED WITH LETTERING INDICATING SERVICE, AND SHOWING FLOW DIRECTION. ALL PIPING SHALL BE LABELED AND COLOR-CODED ACCORDING TO ANSI Z535.1-1991 SAFETY COLOR CODE AND ANSI A13.1-1981 SCHEME FOR IDENTIFICATION OF PIPING SYSTEM. FLOW DIRECTION ARROWS SHALL BE INTEGRAL WITH PIPING SYSTEM SERVICE LETTERING TO ACCOMMODATE BOTH DIRECTIONS, OR AS SEPARATE UNIT ON EACH PIPE LABEL TO INDICATE FLOW DIRECTION. LETTERING SHALL BE AT LEAST 1-1/2 INCHES HIGH. 4. DUCTWORK SYSTEMS SHALL HAVE PLASTIC LAMINATED DUCT LABELS IDENTIFYING AIR FLOW TYPE AND SYSTEM NUMBER WITH PERMANENT ADHESIVE ON AIR DUCTS WITH THE FOLLOWING CODES: A. BLUE: FOR COLD-AIR SUPPLY DUCTS. B. YELLOW: FOR HOT-AIR SUPPLY DUCTS. C. GREEN: FOR EXHAUST-, OUTSIDE-, RELIEF-, RETURN-, AND MIXED-AIR DUCTS. D. ASME A13.1 COLORS AND DESIGNS: FOR HAZARDOUS MATERIAL EXHAUST. 5. VALVE TAGS SHALL BE 1/32 INCH THICK MINIMUM, BRASS TAGS WITH 1/4 LETTERS FOR PIPING SYSTEM ABBREVIATION AND 1/2 INCH NUMBERS. PROVIDE BRASS WIRE-LINK, BEADED CHAIN, OR S-HOOK FASTENER. 6. EQUIPMENT LABELS SHALL HAVE 1/32 INCH MINIMUM THICK BRASS OR 1/16 INCH THICK MULTILAYER, MULTICOLOR PLASTIC FOR MECHANICAL ENGRAVING WITH PREDRILLED HOLES FOR ATTACHMENT WITH STAINLESS STEEL SELF-TAPPING SCREWS. LABELS SHALL BE CAPABLE OF TEMPERATURES UP TO 160 DEG F. THE MINIMUM LETTER SIZE IS 1/4 INCH FOR LABELS IF VIEWING DISTANCE IS LESS THAN 24 INCHES, ½ INCH FOR VIEWING DISTANCES UP TO 72 INCHES, AND PROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING DISTANCES. INCLUDE SECONDARY LETTERING TWO-THIRD TO THREE-FOURTHS THE SIZE OF PRINCIPAL LETTERING. 7. WARNING TAGS SHALL BE PREPRINTED OR PARTIALLY PREPRINTED, ACCIDENT-PREVENTION TAGS, OF PLASTICIZED CARD STOCK WITH MATTE FINISH SUITABLE FOR WRITING. THE TAGS SHALL BE 3 BY 5-1/4 INCHES MINIMUM AND SECURED BY BRASS GROMMET AND WIRE. PROVIDE WITH BLACK LETTERING AND A YELLOW BLACK BACKGROUND. MECHANICAL INSULATION 1. ALL INSULATION SHALL COMPLY WITH NFPA 90A AND B. ALL INSULATION INSTALLED INDOORS SHALL HAVE A FLAME SPREAD INDEX OF 25 OR LESS AND A SMOKE SPREAD INDEX OR 50 OR LESS. 2. ALL INSULATION THICKNESS SHALL COMPLY WITH ASHRAE/IES STANDARD 90.1-2007. 3. ALL INSULATED SYSTEMS SHALL BE INSULATED COMPLETELY INCLUDING THROUGH PENETRATIONS, VALVE BODIES, AND AREAS OF EQUIPMENT NOT PROVIDED WITH FACTORY INSTALLED INSULATION. 4. ALL INSULATION SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS UNLESS OTHERWISE NOTED: OWENS-CORNING, KNAUF, CERTAINTEED OR JOHNS MANVILLE 5. DUCTWORK INSULATION: A. INTERIOR CONCEALED DUCTWORK INSULATION: MINERAL OR GLASS FIBERS BONDED WITH A THERMOSETTING RESIN. COMPLY WITH ASTM C553, TYPE II AND ASTM C 1290, TYPE III WITH FACTORY APPLIED FSK JACKET. INSULATION SHALL HAVE A MAXIMUM VAPOR PERMEABILITY OF 0.02 PERM-IN. INSULATION SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS UNLESS OTHERWISE NOTED: CERTAINTEED CORP (SOFTTOUCH DUCT WRAP), JOHNS MANVILLE (MICROLITE), KNAUF INSULATION (FRIENDLY FEEL DUCT WRAP), MANSON INSULATION (ALLEY WRAP), OR OWENS CORNING (SOFTR ALL-SERVICE DUCT WRAP). METAL DUCTS 1. DUCTWORK SHALL COMPLY WITH NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS," NFPA 90B, "INSTALLATION OF WARM AIR HEATING AND AIR CONDITIONING SYSTEMS.", AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE. 2. GALVANIZED SHEET STEEL: G90 COATED GALVANIZED SHEET STEEL COMPLYING WITH ASTM A 653/A 653M. 3. ALUMINUM SHEETS: ASTM B 209 ALLOY 3003, H14 TEMPER WITH MILL FINISH FOR CONCEALED DUCTS AND STANDARD ONE-SIDE BRIGHT FINISH FOR DUCT SURFACES EXPOSED TO VIEW. 4. FLEXIBLE DUCTS: FLEXIBLE DUCTS SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS UNLESS OTHERWISE NOTED: FLEXMASTER U.S.A., HART & COOLEY, OR THERMAFLEX. A. NONINSULATED FLEXIBLE DUCTS SHALL BE UL181, CLASS 1, POLYMER FILM SUPPORTED BY HELICALLY WOUND, SPRING-STEEL WIRE. SHALL BE RATED FOR 4 INCH W.G. POSITIVE AND 0.5 INCH NEGATIVE PRESSURE. FLEXIBLE DUCTS SHALL BE SUPPORTED BY ELBOW SUPPORTS AND THE SUPPORTS SHALL BE UL LISTED FOR USE IN RETURN AIR PLENUMS. B. INSULATED FLEXIBLE DUCTS SHALL BE UL181, CLASS 1, POLYMER FILM SUPPORTED BY HELICALLY WOUND, SPRING-STEEL WIRE WITH FIBROUS-GLASS INSULATION AND POLYETHYLENE VAPOR-BARRIER FILM. SHALL BE RATED FOR 4 INCH W.G. POSITIVE AND 0.5 INCH NEGATIVE PRESSURE. FLEXIBLE DUCTS SHALL BE SUPPORTED BY ELBOW SUPPORTS AND THE SUPPORTS SHALL BE UL LISTED FOR USE IN RETURN AIR PLENUMS. DUCT ACCESSORIES 1. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" FOR ACCEPTABLE MATERIALS, MATERIAL THICKNESSES, AND DUCT CONSTRUCTION METHODS UNLESS OTHERWISE INDICATED 2. DUCT ACCESSORIES SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: RUSKIN COMPANY OR GREENHECK CORPORATION UNLESS OTHERWISE NOTED. A. MANUAL VOLUME DAMPERS: 0.064 IN THICK GALVANIZED STEEL FRAME CHANNELS AND BLADES. LOW-LEAKAGE RATING AND BEARING AMCA'S CERTIFIED RATINGS SEAL FOR BOTH AIR PERFORMANCE AND AIR LEAKAGE. SUITABLE FOR HORIZONTAL OR VERTICAL APPLICATIONS. AIR DIFFUSION DEVICES 1. AIR DIFFUSION DEVICES: DEVICES SHALL BE SPECIFICALLY DESIGNED FOR VARIABLE AND CONSTANT VOLUME AIR FLOWS. FRAME TYPE AND PHYSICAL CHARACTERISTICS AND PERFORMANCE SHALL BE AS SCHEDULED. DEVICES SHALL BE SUBJECT TO COMPLIANCE WITH REQUIREMENTS AND SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: PRICE OR TITUS TESTING, ADJUSTING AND BALANCING 1. TESTING, ADJUSTING AND BALANCING SHALL BE PERFORMED BY ONE OF THE FOLLOWING COMPANIES: ABSOLUTE BALANCE CO., AIR FLOW TESTING, BARMATIC INSPECTING, ENER-TECH, ENVIRO- AIR/TOTAL BALANCE, INTERNATIONAL TEST AND BALANCE. 2. TESTING, ADJUSTING, AND BALANCING AGENT SHALL BE NEBB CERTIFIED. 3. SET SYSTEM AIRFLOW AND WATER FLOW RATES WITHIN THE FOLLOWING TOLERANCES: A. SUPPLY, RETURN, AND EXHAUST FANS AND EQUIPMENT WITH FANS: 0 TO +10%. B. AIR OUTLETS AND INLETS: -5% TO +5%. C. HEATING-WATER FLOW RATE: 0 TO +10%. D. COOLING-WATER FLOW RATE: 0 TO +5%. 4. INSPECTIONS: AFTER TESTING AND BALANCING ARE COMPLETE, OPERATE EACH SYSTEM AND RANDOMLY CHECK MEASUREMENTS TO VERIFY THAT THE SYSTEM IS OPERATING ACCORDING TO THE FINAL TEST AND BALANCE READINGS DOCUMENTED IN THE FINAL REPORT. AFTER INITIAL INSPECTION IS COMPLETE AND EVIDENCE BY RANDOM CHECKS VERIFIES THAT TESTING AND BALANCING ARE COMPLETE AND ACCURATELY DOCUMENTED IN THE FINAL REPORT, REQUEST THAT A FINAL INSPECTION BE MADE BY ARCHITECT. 5. ADDITIONAL TESTS: WITHIN 90 DAYS OF COMPLETING TAB, PERFORM ADDITIONAL TESTING AND BALANCING TO VERIFY THAT BALANCED CONDITIONS ARE BEING MAINTAINED THROUGHOUT AND TO CORRECT UNUSUAL CONDITIONS. IF INITIAL TAB PROCEDURES WERE NOT PERFORMED DURING NEAR- PEAK SUMMER AND WINTER CONDITIONS, PERFORM ADDITIONAL TESTING, INSPECTING, AND ADJUSTING DURING NEAR-PEAK SUMMER AND WINTER CONDITIONS. 100 RECEPTION 101 STORAGE 102 KITCHEN 103 FOCUS 104 WORK/COPY 105 OPEN OFFICE 106 HUDDLE ROOM 107 FOCUS S-1 8"ø 150 1 M01 M01 M01 M01 M01 M01 M01 M01 M01 M01 M01 M01 M01 M04 M03 M03M03 M02 M02 100 CFM 150 CFM R-1 24"x12" --- 1 R-1 24"x12" --- 1 224 S. Michigan Ave.STE 1400Chicago, IL 60604Tel: 312.554.1400 www.stantec.comDATE:PRINT TIME STAMP:REVIEWED:DRAWN BY:COPYRIGHT © 2020 WALGREEN CO.WALGREENSAREA OFFICE -TWO PENN MARK -SUITE 140REVISIONSNO. DATE BY DESCRIPTIONLOC# 1397-1DESIGN PROJECT NO:Store Planning and Design Development106 Wilmot RoadDeerfield, IL 60015-5105Permit/Seal KEY PLAN:100 % CONSTRUCTION DOCUMENT REVIEW2021.06.18ORIGINAL SHEET -ARCH E1The Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing -any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction oruse for any purpose other than that authorized by Stantec is forbidden.Copyright Reserved11555 N. Meridian St.Carmel, IN 46032222702245ISSUE FOR BIDDING AND PERMIT2021.07.02M101MECHANICAL PLANS, DETAILS AND SCHEDULESMECHANICAL SHEET LIST NO. DRAWING NAME 2021.07.02 BIDSM102 MECHANICAL DETAILS M101 MECHANICAL PLANS, DETAILS AND SCHEDULES MECHANICAL KEYNOTES M01 EXISTING DIFFUSER TO REMAIN. PROVIDE PRE-CONSTRUCTION AIR BALANCE AND FURNISH RESULTS TO ENGINEER. VERIFY POST-CONSTRUCTION AIRFLOWS MATCH PRE-CONSTRUCTION VALUES. M02 RELOCATE EXISTING DIFFUSER AND EXTEND EXISTING FLEX DUCT TO NEW DIFFUSER LOCATION. TARGET AIRFLOWS ARE LISTED ON PLAN. M03 ADD NEW TRANSFER AIR DUCT IN DEMISING WALL ABOVE CEILING. REFER TO DETAILS. M04 CONNECT NEW DIFFUSER WITH FLEX DUCT TO EXISTING DUCT MAIN DOWNSTREAM OF ZONE'S AIR TERMINAL UNIT. PROVIDE BALANCING DAMPER IN HARD DUCT TAP. REFER TO DETAILS FOR INSTALLATION REQUIREMENTS. TARGET AIRFLOWS ARE LISTED ON PLAN. MECHANICAL GENERAL NOTES 1. COORDINATE NEW DUCTWORK WITH SITE CONDITIONS EQUIPMENT MANUFACTURER AND ALL OTHER TRADES TO AVOID INTERFERENCES. 2. PROVIDE ACCESS AROUND ALL NEW EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS. 3. ALL CORING THROUGH FLOORS SHALL BE BY MECHANICAL CONTRACTOR. 4. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE, UNLESS OTHERWISE NOTED. COORDINATE ROUTING WITH OTHER TRADES TO AVOID INTERFERENCES. 5. BALANCE ALL AIR SYSTEMS TO INDICATED AIR FLOW RATES. 6. DUCT SIZES TO DIFFUSERS SHALL MATCH NECK SIZE OF EACH. REFER TO GRILLE, REGISTER & DIFFUSER SCHEDULE. 7. REFER TO MECHANICAL SPECIFICATION FOR DUCTWORK INSULATION REQUIREMENTS. 8. ALL DUCTWORK SHALL BE CONCEALED IN WALLS AND/OR CEILING SPACE, UNLESS OTHERWISE NOTED. 9. SEAL ALL PENETRATIONS THROUGH WALLS PER DETAILS AND SPECIFICATIONS. 10. COORDINATE EXACT LOCATIONS OF ALL DIFFUSERS AND RETURN GRILLES WITH ARCHITECTURAL AND ELECTRIC REFLECTED CEILING PLANS. 11. PROVIDE A PRE-CONSTRUCTION AIR BALANCE REPORT AND FURNISH RESULTS TO ENGINEER. 1/8" = 1'-0"M101 3 FIRST LEVEL SHEET METAL PLAN NOTES: RETURN AIR ALL CONCEALED 1,000 0.10 2 A 6 X X SUPPLY AIR LOW PRESSURE (DOWNSTREAM OF ATU)CONCEALED 1,000 0.10 2 A 6 X X X 1.5 1.5 XMAX VELOCITY(FPM)MAX FRICTION(IN-WG/100')DESIGN SYSTEMPRESSURE (IN-WG)SEAL CLASSMAX LEAKAGE RATESINGLE WALLG90 GALV SHEETSTEELFIBERGLASS BLANKETTHICKNESS (IN)DENSITY (LB/FT³)FSKSYSTEM APPLICATION LOCATION DESIGN CRITERIA CONSTRUCTION PRODUCT MATERIAL INSULATION FACTORY JACKET NOTES DUCT SYSTEM APPLICATION SCHEDULE NOTES: 1. REFER TO REFLECTED CEILING PLANS EXACT LOCATION. PROVIDE ALL FRAMES AND ACCESSORIES AS REQUIRED FOR PROPER INSTALLATION. 2. FLEXIBLE DUCTWORK SHALL BE THE SAME SIZE AS THE DIFFUSER NECK OR AN EQUIVALENT ROUND DUCT. FLEXIBLE DUCTWORK SHALL BE SUPPORTED TO PREVENT KINKS OR BENDS. 3. COLOR TO BE SELECTED BY ARCHITECT FROM STANDARD COLORS. 4. PROVIDE RETURN BOOT, REFER TO DETAIL. R 1 24x12 ---24x12 N/A CEILING WHITE STEEL N/A PRICE 80 4 S 1 24X24 SEE PLAN SEE PLAN 4-WAY CEILING WHITE STEEL N/A PRICE SCD MARK NUMBER UNIT IDENTIFICATION DIFFUSER FACE SIZE (IN) FLOW RANGE (CFM) DIFFUSER NECK SIZE (IN) FLOW PATTERN MOUNTING TYPE COLOR MATERIAL ACCESSORY MANUFACTURER MODEL NUMBER NOTES GRILLE, REGISTER, DIFFUSER SCHEDULE NOTES: 1. PROVIDE PRE-CONSTRUCTION AIR BALANCE AND FURNISH RESULTS TO ENGINEER. 2. MATCH EXISTING AIRFLOWS. FOCUS 107 95 NOTE 1 NOTE 2 HUDDLE ROOM 106 210 NOTE 1 NOTE 2 OPEN OFFICE 105 500 NOTE 1 650 WORK/COPY 104 110 N/A 150 FOCUS 103 60 N/A 100 KITCHEN 102 95 NOTE 1 NOTE 2 STORAGE 101 45 NOTE 1 NOTE 2 RECEPTION 100 290 NOTE 1 NOTE 2 ROOM NAME ROOM NUMBER AREA EXISTING CFM TARGET NEW CONST. CFM AIR BALANCE SCHEDULE COPYRIGHT © 2021 WALGREEN CO.09/29/21