M101.0
3. MECHANICAL FASTENERS SUPPORTING INSULATION ON UNDERSIDE OF DUCTS OVER 24" WIDE (SPACED 3" MAXIMUM FROM THE BUTT JOINT). 4. VAPOR-RETARDER TAPE OVER TEARS AND PENETRATIONS OF THE VAPOR- RETARDER JACKET TO KEEP AIR TIGHT CONDITION. 5. ALTERNATE METHOD OF LAP SEAL - LONGITUDINAL JOINT LAPPED AND FOLDED, THEN STAPLED SECURELY IN PLACE. 1. BLANKET INSULATION WITH FACTORY-APPLIED VAPOR-RETARDER JACKET. 2. FACTORY LAP ALL SEALS (SEALED WITH ADHESIVE AND/OR STAPLES OR VAPOR-RETARDER TAPE). 6. HANGER ON EXTERIOR OF INSULATION. ENCAPSULATE EXPOSED END OF ANGLE. SEAL WITH ADHESIVE OR VAPOR-RETARDER TAPE. 7. HANGER EMBEDDED IN INSULATION. ENCAPSULATE EXPOSED END OF ANGLE. SEAL WITH ADHESIVE OR VAPOR-RETARDER TAPE. 8. COMPLETELY ENCAPSULATE HANGER ROD AND ANGLE. SEAL TOP PENETRATION. ENCAPSULATE AND SEAL STRAP HANGERS IN A SIMILAR MANNER. NOTES BLANKET FIBERGLASS INSULATION DETAIL SCALE: NONE STAPLE-STITCHING METHOD B 6 4 5 2 1 6 7 8 9 8 4 5 2 1 7 8 9 3 BUTT-JOINT METHOD A RETURN AIR GRILLE SOUND BOOT DETAIL SCALE: NONE RETURN AIR GRILLE SUPPORT INTERNALLY LINED SHEETMETAL OR RIGID FIBERBOARD CEILING 0.75 X "H"AS REQUIRED TO CLEAR BUILDING CONSTRUCTION"H" 3'-0" RECTANGULAR DUCT BRANCH CONNECTION DETAIL SCALE: NONE NOTE: 1. FURNISH THIS TYPE CONNECTION FOR BRANCHES WITH LESS THAN 25% OF TOTAL AIR FLOW. DUCT BRANCH 1/3 W. 5" MINIMUM 45 DEG. CLINCH COLLAR SUPPLY AIR FLOW RETURN/EXHAUS T AIR FLOW W ROUND OR FLAT OVAL DUCT BRANCH TAKE-OFF DETAIL SCALE: NONE SUPPLY DUCT RETURN OR EXHAUST DUCTAIRFLOWAIRFLOWCONCENTRI C TEE FITTING ECCENTRIC TEE FITTING ROUND/RECTANGULAR DUCT BRANCH CONNECTION DETAIL SCALE: NONE NOTE: 1. FURNISH THIS TYPE CONNECTION FOR BRANCHES WITH LESS THAN 25% OF THE TOTAL AIR FLOW RETURN/EXHAUST AIRFLOW SUPPLY AIR FLOW ROUND OR RECTANGULAR BRANCH DUCT CONCENTRIC SPIN-IN FITTING MAIN DUCT SUPPLY AIR BRANCH SPIN-IN AND CEILING DIFFUSER DETAIL SCALE: NONE SUSPENDED CEILING PROVIDE SPIN-IN AND LOCKING MANUAL VOLUME DAMPER WITH 2" BUILD OUT EXTENSION. SUPPLY TRUNK DUCT (REFER TO PLAN FOR SIZE) S.S. SCREW CLAMP (TYP-3)SEAL TAP WITH DUCT JOINT SEALANT PROVIDE MINIMUM 12" RIGID DUCT SPOOL PIECE CONNECTED TO DIFFUSER THROAT. PROVIDE MAXIMUM 5 FEET IN LENGTH OF FLEXIBLE DUCT. SEAL AIR TIGHT WITH MASTIC AND 1/2" MIN. WIDTH DRAW BANDS TO RIGID DUCT CONNECTIONS AT BOTH ENDS FLEX DUCT DIAMETER SAME SIZE AS DIFFUSER THROAT. SUPPORT FLEX DUCT WITHOUT SAGS OR KINKS SQUARE, ROUND OR RECTANGULAR CEILING DIFFUSER PROVIDE THERMAFLEX FLEXFLOW ELBOW SUPPORT OR EQUAL ACCESSORY BY LISTED MANUF. SUSPEND ELBOW FROM STRUCTURE T-BAR BY OTHERS FOR LAY-IN. PROVIDE MANUFACTURERS PLASTER FRAME FOR HARD CEILING SURFACE MOUNTING 3'-0" MIN DUCT SIZE OPENING AT TOP OF DUCT ACOUSTICALLY (FIBER FREE) LINED SHEET METAL TRANSFER AIR DUCT REFER TO FLOOR PLANS FOR DUCT SIZES SEAL OPENINGS PER SPECIFICATIONS TYPICAL TRANSFER DUCT (T.A.D.) DETAIL SCALE: NONE 224 S. Michigan Ave.STE 1400Chicago, IL 60604Tel: 312.554.1400 www.stantec.comDATE:PRINT TIME STAMP:REVIEWED:DRAWN BY:COPYRIGHT © 2020 WALGREEN CO.WALGREENSAREA OFFICE - TWO PENN MARK - SUITE 140REVISIONSNO. DATE BY DESCRIPTIONLOC# 1397-1DESIGN PROJECT NO:Store Planning and Design Development106 Wilmot RoadDeerfield, IL 60015-5105Permit/Seal KEY PLAN:100 % CONSTRUCTION DOCUMENT REVIEW2021.06.18ORIGINAL SHEET -ARCH E1The Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing -any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction oruse for any purpose other than that authorized by Stantec is forbidden.Copyright Reserved11555 N. Meridian St.Carmel, IN 46032222702245ISSUE FOR BIDDING AND PERMIT2021.07.02M102MECHANICAL DETAILSCOPYRIGHT © 2021 WALGREEN CO.09/29/21