Loading...
HomeMy WebLinkAboutS105.0N.I.C. N.I.C. SD 01 02 RECEPTION 100 STORAGE 101 KITCHEN 102 HUDDLE ROOM 106 FOCUS 107 WORK/COPY 104 OPEN OFFICE 105 FOCUS 103 03 03 ORIGINAL SHEET - ARCH E1 DATE: PRINT TIME STAMP:REVIEWED: DRAWN BY:COPYRIGHT © 2021 WALGREEN CO.WALGREENS11555 N. Meridian St.Carmel, IN 46032222702245AREA OFFICE - TWO PENN MARK - SUITE 140REVISIONSNO. DATE BY DESCRIPTIONLOC# 1397-1DESIGN PROJECT NO: Store Planning and Design Development106 Wilmot RoadDeerfield, IL 60015-5105224 S. Michigan Ave.STE 1400Chicago, IL 60604Tel: 312.554.1400 • www.stantec.comThe Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction oruse for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedPermit/Seal KEY PLAN:100 % CONSTRUCTION DOCUMENT REVIEW2021.06.18ISSUE FOR BIDDING AND PERMIT2021.07.02Stantec Architecture and Engineering, LLC.1 REFLECTED CEILING PLAN 1/4" = 1'-0" KEY NOTE EXISTING CEILING GRID XX EXISTING 2X4 LIGHT FIXTURE SUPPLY DIFFUSER. REFER TO MECHANICAL. RETURN GRILLE. REFER TO MECHANICAL. EXISTING LINEAR DIFFUSER EXISTING EXIT SIGN EXISTING SPRINKLER HEAD 2X4 LIGHT FIXTURE. REFER TO ELECTRICAL. EMERGENCY LIGHT. REFER TO ELECTRICAL. REFLECTED CEILING NOTES KEY NOTES LEGEND 01 POWER POLE. REFER TO ELECTRICAL. 02 G.C.TO MATCH EXISTING GRID AND TILE AS NEEDED. 1. ALL CEILINGS TO BE 8'-0" UNLESS NOTED OTHERWISE. G.C. TO VERIFY EXISTING CEILING HEIGHT. 2. ALL ACOUSTICAL CEILING GRIDS TO BE CENTERED WITHIN THE ROOM U.N.O. 3. ALL PENETRATIONS IN CEILING TILES, SUCH AS LIGHT FIXTURES, FIRE SPRINKLER HEADS AND THE LIKE SHALL OCCUR AT THE CENTER OF THE TILE. 4. ARCHITECTURAL REFLECTED CEILING PLANS ARE TO BE USED FOR THE LOCATIONS OF LIGHT FIXTURES AND MECHANICAL GRILLS WITHIN THE CEILING. REFER TO ELECTRICAL AND MECHANICAL DRAWINGS AND SCHEDULE FOR FIXTURE'S SPECIFICATIONS AND IDENTIFICATION. 5. ALL LINEAR SLOT DIFFUSERS TO BE CONTINUOUS U.N.O. BLOCK OFF AS REQUIRED. 6. AT ALL MECH, ELEC, AND IT ROOMS, COORDINATE SERVICE FIXTURE LOCATIONS, AND SUSPENSION LENGTH WITH EQUIPMENT. 7. THE REFLECTED CEILING PLAN DOES NOT INTEND TO SHOW COMPLETE SMOKE DETECTOR AND OTHER FIRE PROTECTION SYSTEM DEVICE LOCATIONS. EXISTING TO REMAIN, RELOCATE SPRINKLER HEADS AND SMOKE DETECTORS PER NEW CEILING GRID LAYOUT AS REQUIRED. 8. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS AND SPECIFICATIONS OF MECHANICAL DIFFUSERS, RETURNS, AND EXHAUST GRILLS. 9. REFER TO FIRE SUPPRESSION DRAWINGS FOR LOCATIONS OF SPRINKLER HEADS. 10. REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. 11. EXISTING LIGHT FIXTURES TO BE REINSTALLED. REFER TO DEMOLITION PLAN FOR FIXTURES TO BE REUSED. 12. G.C. TO PATCH AND/OR REPLACE ANY DEFECTED GRID OR CEILING TILE AS REQUIRED. 13. G.C. TO PROVIDE BID ALTERNATE FOR NEW CEILING TILE. A-102REFLECTED CEILINGA.SANCHEZ21.07.02B. STANKOSA.S.A.S.03 G.C. TO PROVIDE NEW ACOUSTIC CEILING TILE AT FORMER LIGHT FIXTURE LOCATIONS. NEW CEILING TILE TO MATCH EXISTING. 09/29/21