Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E104.0
N.I.C. N.I.C. RECEPTION 100 STORAGE 101 KITCHEN 102 HUDDLE ROOM 106 FOCUS 107 WORK/COPY 104 OPEN OFFICE 105 FOCUS 103 EM1 MS1 MS1 EM1 01 01 01 02 (R) (R) (R) MS1 MS1MS1 MS1OS OS OS OS MASTER OVERRIDE SWITCH FOR OPEN OFFICE 105, RECEPTION 100 04 (TYP) EM1 EM1 EM1 05 05 05 05 05 05 EX1 EX1 ORIGINAL SHEET - ARCH E1 DATE:PRINT TIME STAMP:REVIEWED: MTFDRAWN BY: ABCOPYRIGHT © 2021 WALGREEN CO.WALGREENS11555 N. Meridian St.Carmel, IN 46032222702245AREA OFFICE - TWO PENN MARK - SUITE 140REVISIONSNO. DATE BY DESCRIPTIONLOC# 1397-1DESIGN PROJECT NO: Store Planning and Design Development106 Wilmot RoadDeerfield, IL 60015-5105224 S. Michigan Ave.STE 1400Chicago, IL 60604Tel: 312.554.1400 • www.stantec.comThe Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction oruse for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedPermit/Seal KEY PLAN:100 % CONSTRUCTION DOCUMENT REVIEW2021.06.18ISSUE FOR BIDDING AND PERMIT2021.07.02Stantec Architecture and Engineering, LLC.E-111Electrical New Reflected Ceiling Plan1 ELECTRICAL NEW REFLECTED CEILING PLAN 1/4" = 1'-0" GENERAL NOTES 1.EQUIPMENT SHOWN IN A DARK SOLID LINE TYPE REPRESENT NEW WORK BY THIS CONTRACTOR. 2. EQUIPMENT SHOWN IN A LIGHT SOLID LINE TYPE REPRESENT NEW WORK BY OTHERS AND/OR EXISTING, AS NOTED. 3. REFER TO LUMINAIRE, PANELBOARD AND LIGHTING CONTROLS SCHEDULE FOR MORE INFORMATION. 4. CONTRACTOR SHALL CLEAN AND RELAMP EXISTING LUMINAIRES. 5. SEE SHEET TYPE SPECIFICATIONS FOR MORE INFORMATION. 6. EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CONNECTED AHEAD OF THE LOCAL BRANCH CIRCUIT (USING A 20A LOCKED 'ON' CIRCUIT BREAKER) SERVING THE ROOM OR AREA. 7. WIRING DEVICE COLOR AND COVERPLATE FINISH SHALL MATCH EXISTING. KEYED NOTES 1. RELOCATED 2X4 LUMINAIRE. LUMINAIRE SHALL BE CONNECTED TO LOCAL LIGHTING BRANCH CIRCUIT RETAINED IN PLACE FOR RE-USE USING 2#12 AND 1 #12 GND IN 3/4"C. 2. PROVIDE NEW EMERGENCY LED LIGHT FIXTURE. RE-USE EXISTING BRANCH CIRCUIT CONDUIT AND WIRE RETAINED IN PLACE FOR RE-USE. 3. TIE-IN WALL MOUNTED OCCUPANCY SENSOR (DUAL TECHNOLOGY-PASSIVE INFRARED, ULTRASONIC) IN NEW ENCLOSED SPACES AS MANUFACTURED BY SENSOR SWITCH #WSX PDT OR APPROVED EQUAL BY LEVITON. THIS NOTE IS TYPICAL FOR ALL ENCLOSED SPACES. PROVIDE ALL REQUIRED POWER PACKS/RELAYS, CONDUIT, WIRE AND LOW VOLTAGE CABLE FOR INTERFACING BETWEEN LOAD, WALLBOX AND SWITCH. 4. CONTRACTOR SHALL TEST EXISTING EXIT SIGNS AND BATTERY IN ACCORDANCE WITH LIFE SAFETY CODE AND REPLACE WITH NEW IF TEST RESULTS ARE NOT SATISFACTORY. 5. RE-USE EXISTING BACKBOX AND CONDUIT RETAINED IN PLACE FOR REUSE FOR LIGHTING CONTROL, COVERPLATE AND WIRING INSTALLATION. LEGEND KEY NOTEXX EXISTING EXIT SIGN RELOCATED 2X4 LIGHT FIXTURE CEILING MOUNTED EMERGENCY LUMINAIRE LIGHTING FIXTURE ALTERATION REPLACES LESS THAN 10% OF LUMINAIRES AND DOES NOT INCREASE THE INSTALLED LIGHTING POWER DENSITY 09/29/21