FP100.0
(D) (E) (E)C1C1N.I.C. N.I.C. T ST SD DRAWING TITLE ##" = 1'-0" 1 MECHANICAL SYSTEM INDICATION HEAVY LINE- WEIGHT INDICATES NEW WORK LIGHT LINE WEIGHT- INDICATES EXISTING EQUIPMENT OR REFERENCED INFORMATION HATCH MARKS - EQUIPMENT OR MATERIALS TO BE DISCONNECTED AND REMOVED DRAWING/ DETAIL TITLE NOTE: DRAWING TITLE MAY NOT APPEAR ON LARGE SCALE DETAIL DRAWINGS DETAIL NUMBER REFER TO THIS DRAWING FOR DETAIL SECTION CUT SYMBOL NORTH ARROW ENLARGED PLAN DETAIL REFER TO THIS SHEET FOR ENLARGED PLAN CONSTRUCTION NOTEDRAWING REVISION SYMBOL DRAWING REVISION NUMBER DRAWING NOTATIONS ADDITIONAL DRAWING WHERE DETAIL IS REFERENCED ENLARGED PLAN NUMBER N 1 M101 1 M101 SECTION NUMBER SHEET WHERE SECTION IS DRAWN PROJECT NORTH TRUE NORTH NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. DESCRIPTIONSYMBOL DASHED LINES- PIPING ROUTED BELOW SLAB OR GRADE A10 P100 P200 NEW / EXISTING CONNECTIONS EXISTING SYSTEM COMPONENT TO REMAIN POINT OF NEW CONNECTION NEW SYSTEM COMPONENT EXISTING POINT OF DISCONNECT EXISTING SYSTEM COMPONENT TO REMAIN POINT OF DISCONNECT EXISTING SYSTEM COMPONENT TO BE REMOVED TEXT LEADER INFORMATION TEXT EXISTING CONNECTIONS EXISTING SYSTEM COMPONENT TO REMAIN CAP OFF EXISTING FIRE PROTECTION SYMBOLS S STORM PIPINGST DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER RETURN PIPING DOMESTIC HOT WATER PIPING FIRE PROTECTION PIPING SANITARY PIPING NATURAL GAS PIPING SAN NG FP VENT PIPING PRESSURE GAGE WITH COCK FLEXIBLE CONNECTOR PIPE OUT TOP PIPE OUT BOTTOM PIPE TURNED DOWN PIPE TURNED UP UNION SOLENOID VALVE MOTOR OPERATED VALVE THERMOMETER THREE WAY CONTROL VALVE TWO WAY CONTROL VALVE PRESSURE RELIEF VALVE PRESSURE REGULATOR VALVE BUTTERFLY VALVE STRAINER w/HOSE END CONNECTION PLUG VALVE FULL PORT BALL VALVE CHECK VALVE BALANCING VALVE BALANCE VALVE W/ TEST PORTS GLOBE VALVE SUB-SOIL DRAINSSD GENERIC VALVE M AUTOMATIC AIR VENT (PIPE TO NEAREST DRAIN) MANUAL AIR VENT (PIPE TO NEAREST DRAIN) CONSTRUCTION NOTE NUMBER X X DEMOLITION NOTE NUMBER HWR HW CW ACID WASTE ACID VENTAV AW SECONDARY STORM PIPINGSST V FIRE PROTECTION SPECIFICATIONS 100 RECEPTION 101 STORAGE 102 KITCHEN 103 FOCUS 104 WORK/COPY 105 OPEN OFFICE 106 HUDDLE ROOM 107 FOCUS F03F03 F03F03 F03F03 F03F03 F03F03 F01F01 F01F01F01F01 F02F02 90 DEGREE ELBOW. 1" SIZE. QUANTITY AS REQUIRED TO ACCOMMODATE SPRINKLER HEAD SPRINKLER MAIN 90 DEGREE ELBOW. 1" SIZE. QUANTITY AS RQUIRED TO ACCOMMODATE SPRINKLER HEAD TYPICAL SPRINKLER HEAD. 1" x 1/2" REDUCER FITTING SUSPENDED CEILING TYPICAL SPRINKLER HEAD DETAIL Scale: None METAL STUD AND DRYWALL PARTITION WALL NOTES: 1. PIPE PENETRATION DETAIL SIMILAR FOR UNINSULATED PIPING. PIPE INSULATION 360º SPLIT SHEET METAL SHIELD WHERE INSULATED PIPES PENETRATES WALL PIPE IN EXPOSED AREAS ONLY: PROVIDE FINISHED ESCUTCHEON PLATE FLUSH AGAINST WALL (SIZE TO COMPLETELY COVER OPENING.) NON-FIRE RATED STUD AND DRYWALL PARTITION WALL PIPE PENETRATION DETAIL Scale : None SPRINKLER LEGEND EXISTING NEW UPRIGHT PENDANTS CEILING MOUNTED (CONCEALED HEADS) UNDER OBSTRUCTION NOTE: HEADS ARE SHOWN FOR COORDINATION AND ARE CONSIDERED THE PREFERRED LOCATION. THE CONTRACTOR SHALL VERIFY QUANTITY OF HEADS AND PROVIDE ALL ADDITIONAL HEADS BASED ON FIELD CONDITIONS, CONSTRUCTION, CODE REQUIREMENTS, AND HYDRAULIC CALCULATIONS. PROVIDE SUBMITTAL FOR ARCHITECTURAL REVIEW OF FINAL HEAD LAYOUT, PIPING TO BE COORDINATED WITH ALL OTHER TRADES. FIRE PROTECTION SHEET LIST NO. DRAWING NAME 2021.07.02 BIDSFP101 FIRE PROTECTION PLANS, DETAILS AND SCHEDULES 224 S. Michigan Ave.STE 1400Chicago, IL 60604Tel: 312.554.1400 www.stantec.comDATE:PRINT TIME STAMP:REVIEWED:DRAWN BY:COPYRIGHT © 2020 WALGREEN CO.WALGREENSAREA OFFICE - TWO PENN MARK - SUITE 140REVISIONSNO. DATE BY DESCRIPTIONLOC# 1397-1DESIGN PROJECT NO:Store Planning and Design Development106 Wilmot RoadDeerfield, IL 60015-5105Permit/Seal KEY PLAN:100 % CONSTRUCTION DOCUMENT REVIEW2021.06.18ORIGINAL SHEET -ARCH E1The Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing -any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction oruse for any purpose other than that authorized by Stantec is forbidden.Copyright Reserved11555 N. Meridian St.Carmel, IN 46032222702245ISSUE FOR BIDDING AND PERMIT2021.07.02FP101FIRE PROTECTION PLANS, DETAILS AND SCHEDULESFIRE PROTECTION KEYNOTES F01 ONE STORY SPACE. REWORK EXISTING AUTOMATIC WET PIPE SPRINKLER SYSTEM TO PROVIDE A SYSTEM IN ACCORDANCE WITH NFPA 13 LIGHT HAZARD OCCUPANCY. SPRINKLER HEAD LOCATIONS INDICATED ARE FOR GENERAL REFERENCE ONLY. FIRE PROTECTION CONTRACTOR SHALL REVISE LAYOUT AS REQUIRED TO COMPLY WITH NFPA 13. CONTRACTOR SHALL SUBMIT DEVIATIONS FROM THE INDICATED LAYOUT TO THE ENGINEER OF RECORD. F02 ONE STORY SPACE. NO WORK ANTICIPATED TO EXISTING AUTOMATIC WET PIPE SPRINKLER SYSTEM. VERIFY EXISTING SYSTEM IS ADEQUATE FOR NFPA 13 ORDINARY HAZARD GROUP 1 OCCUPANCY. F03 ONE STORY SPACE. NO WORK ANTICIPATED TO EXISTING AUTOMATIC WET PIPE SPRINKLER SYSTEM. VERIFY EXISTING SYSTEM IS ADEQUATE FOR NFPA 13 LIGHT HAZARD OCCUPANCY. FIRE PROTECTION GENERAL NOTES 1. THESE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK BUT ARE NOT FABRICATION DRAWINGS. COORDINATE FIRE PROTECTION SYSTEMS WITH WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS, ETC. AS REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 2. ALL EQUIPMENT SHALL BE UL LISTED. 3. PIPES SHALL BE SUPPORTED AND BRACED PER NFPA 13. 4. APPROVED SHOP DRAWINGS SHALL BE REVIEWED BY THE STATE FIRE MARSHAL AND LOCAL AUTHORITY HAVING JURISDICTION. 5. APPROVAL BY LOCAL AUTHORITY HAVING JURISDICTION MUST BE RECEIVED PRIOR TO PROCEEDING WITH THE WORK. 6. INSPECT AND REPLACE ALL EQUIPMENT AND PIPING THAT IS DAMAGED OR BENT. HEADS THAT ARE PAINTED OTHER THAN THE ORIGINAL PAINT SHALL BE REPLACED. 7. COORDINATE LOCATIONS OF ALL SPRINKLER HEADS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING LAYOUT. SUBMIT LAYOUT DRAWINGS FOR ARCHITECTURAL APPROVAL. 8. ALL SPRINKLER HEADS SHALL BE CENTERED BOTH WAYS IN ACOUSTICAL CEILING TILES UNLESS NOTED OTHERWISE. 9. PROVIDE A 1” MINIMUM BRANCH TO SPRINKLER HEADS. 1/8" = 1'-0"FP101 A5 FIRST LEVEL FIRE PROTECTION PLAN FIRE PROTECTION GENERAL DEMOLITION NOTES 1 ANY INTERRUPTIONS OF EXISTING SERVICES OR EQUIPMENT SHALL BE PERFORMED AT A TIME APPROVED IN ADVANCE BY THE OWNER’S REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE BUILDING OPERATION. 2 THESE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE EXTENT OF DEMOLITION SHALL BE AS REQUIRED BY THE NEW WORK AND REMOVAL OF MATERIALS/COMPONENTS NOT REQUIRED FOR THE NEW AND RENOVATED SYSTEMS. 3 ALL MECHANICAL SYSTEMS TO BE REMOVED SHALL BE REMOVED COMPLETE WITH ALL RELATED ITEMS INCLUDING HANGERS, SUPPORTS, CONTROLS, ETC., CAP ALL OPEN PIPES AND DUCTS. PATCH AND SEAL ALL OPENINGS AS A RESULT OF DEMOLITION IN RATED WALLS TO MAINTAIN EXISTING WALL’S FIRE OR SMOKE RATING AND TO MATCH EXISTING ADJACENT SURFACES. 4 ALL ITEMS AND EQUIPMENT REMOVED SHALL REMAIN PROPERTY OF THE OWNER UNLESS POSSESSION RIGHTS ARE WAIVED. CONTRACTOR SHALL MEET WITH OWNER PRIOR TO START OF DEMOLITION TO DETERMINE WHICH ITEMS ARE TO BE SALVAGED. CONTRACTOR SHALL REMOVE REMAINING ITEMS FROM SITE. 5 FIELD VERIFY EXACT SIZE AND LOCATION OF ALL EXISTING SERVICES PRIOR TO START OF DEMOLITION. NOTES: WET-PIPE SPRINKLER SYSTEM, STANDARD PRESSURE FP NPS 2 1/2 TO NPS 4 X X X 40 - 100 175 225 2 1/2 ZERO LOSS/LEAKS WET-PIPE SPRINKLER SYSTEM, STANDARD PRESSURE FP NPS 2 AND SMALLER X X 40 - 100 175 225 2 1/2 ZERO LOSS/LEAKSSCH 10 BLACK STEELSCH 30 BLACK STEELSCH 30 GALVANIZED STEELSCH 40 BLACK STEELSCH 40 GALVANIZED STEELSOLDEREDBRAZEDWELDEDPRESSURE SEAL FITTINGSROLL GROOVEDTHREADEDOPERATING TEMPERATURE (°F)MINIMUM WORKING PRESSURE (PSI)TEST PRESSURE (PSI)TEST DURATION (HRS)ACCEPTANCE LEVELSYSTEM ABBREVIATION PIPE SIZE (IN) PIPING MATERIAL JOINTS CONSTRUCTION FIRE PROTECTION PIPING SYSTEM APPLICATION SCHEDULE COMMON WORK RESULTS FOR FIRE PROTECTION 1. REFER TO INDIVIDUAL DIVISION 21 PIPING SECTIONS FOR PIPE, TUBE AND FITTING MATERIALS AND JOINING METHODS. HANGERS AND SUPPORTS FOR FIRE PROTECTION 1. HANGERS AND SUPPORTS SHALL BE MSS SP-69, TYPES 1 THROUGH 58, CONSTRUCTED OF FACTORY-FABRICATED COMPONENTS, FM APPROVED OR UL LISTED. IDENTIFICATION FOR FIRE PROTECTION 1. ALL ABOVE GRADE MECHANICAL PIPING SHALL BE IDENTIFIED WITH SNAP-AROUND MARKERS. 2.ALL VALVES AND REGULATORS NOT DIRECTLY ADJACENT TO, AND SERVING A PIECE OF EQUIPMENT, SHALL BE IDENTIFIED WITH VALVE TAGS. 3.EQUIPMENT SHALL BE IDENTIFIED WITH LAMINATED PERMANENT PLASTIC TAGS. FIRE SUPPRESSION PIPING 1. THE BUILDING SHALL BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM DESIGNED IN ACCORDANCE TO THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 13. A. CORRIDORS, OFFICE AREAS AND SIMILAR SPACES WILL BE DESIGNED AS LIGHT HAZARD OCCUPANCIES AS DEFINED BY NFPA 13. B.STORAGE ROOMS, JANITORS CLOSETS, AND SIMILAR SPACES WILL BE DESIGNED AS ORDINARY HAZARD GROUP 1 OCCUPANCIES AS DEFINED BY NFPA 13. 2.165 F SPRINKLER HEADS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE EXCESSIVE OR ABNORMAL AMOUNT OF HEAT IS PRESENT. 4.ABOVE GROUND PIPING AND FITTINGS WILL BE SIZED AND RATED FOR WORKING PRESSURE AND INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF NFPA 13. 5.PIPE IDENTIFICATION: PROVIDE AND INSTALL, ON 50INTERVALS, AN APPROVED TYPE OF REFLECTIVE PIPE MARKER FOR IDENTIFICATION OF ALL EXPOSED RISERS AND MAINS. PROVIDE AND INSTALL COLORED DIRECTIONAL MARKERS TO IDENTIFY THE DIRECTION OF WATER FLOW. ALL EXPOSED PIPING WILL BE PAINTED RED. COPYRIGHT © 2021 WALGREEN CO.09/29/21