HomeMy WebLinkAboutGN012.0T-SHAPE 180° TURNS CLEAR WIDTH FOR TWO WHEEL CHAIRS TO PASS PARALLEL THROUGH CORRIDOR 180° TURNS AROUND AN OBSTRUCTION WHEELCHAIR TURNING SPACE NOTE: * CORRIDORS WITH OCCUPANCY OF 9 OR LESS ** CORRIDORS WITH OCCUPANCY OF 10 OR MORE ALSO REFER TO OCCUPANT LOAD FOR REQUIRED EGRESS WIDTH. 44" MIN** 44" MIN** 44" MIN** 44" MIN**44" MIN**60DIA. 42*MIN. 42*MIN.48MIN.36MIN.* 48" MIN 36MIN.* 36MIN.* 36MIN.*36MIN.* 60MIN. 36" MIN. * 36" MIN. *60" MIN.44" MIN**44" MIN** 12MIN. CLR. 12MIN. CLR.60MIN. CLR.24MIN.CLR.60MIN. CLR. 'X' < 48"60" MIN.36MIN.*24MAX.48" MIN. 24MAX.32 MIN. MINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR 32 MIN.48" MIN.(D) FRONT APPROACH SLIDING DOORS 48" MIN.(G) FRONT APPROACH FOLDING DOORS 42" MIN. 54" MIN. (E) SLIDE SIDE APPROACH SLIDING/FOLDING DOORS 42" MIN. (H) SLIDE SIDE APPROACH FOLDING DOORS 54" MIN. (F) LATCH SIDE APPROACH SLIDING DOORS 42" MIN.24" MIN. (H) LATCH SIDE APPROACH FOLDING DOORS42" MIN.24" MIN. NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES 22". MIN. 54" MIN. PUSH SIDE 44" MIN.36" MIN.60" MIN.PULL SIDE 48" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER HINGE APPROACH PUSH SIDE44" MIN.48" MIN.PULL SIDE LATCH APPROACH 24" MIN.*** 24" MIN. 22" MIN. 54" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER****60" MIN.(a) PULL SIDE (INTERIOR DOOR) 32" MIN. NOTE: PROVIDE BUMPER IN POCKET TO PREVENT DOOR FROM FULLY RECEDING (b) SLIDING DOOR (c) FOLDING DOOR 32" MIN. PULL SIDE CLEAR LEVEL LANDING PUSH SIDE CLEAR LEVEL LANDING PROVIDE 12" MIN. IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER NOTE: 2% MAX SLOPE AT EXTERIOR LANDINGS ONLY 48MIN. 60MIN.12 32" MIN. CLR. 18MIN. CLEAR @INT.DOORS 24MIN. CLEAR @ EXT. DOOR 10" MIN BOTTOM RAIL LEVER OR U-SHAPED HANDLE 30" TO 44" A.F.F FROM DOOR TO STOP 90.00°18 MIN.X > 8"PULL SIDE * * *CLEAR LEVEL LANDING * 48" MIN.(D) FRONT APPROACH SLIDING DOORS 48" MIN.(G) FRONT APPROACH FOLDING DOORS 42" MIN. 54" MIN. (E) SLIDE SIDE APPROACH SLIDING/FOLDING DOORS 42" MIN. (H) SLIDE SIDE APPROACH FOLDING DOORS 54" MIN. (F) LATCH SIDE APPROACH SLIDING DOORS 42" MIN.24" MIN. (H) LATCH SIDE APPROACH FOLDING DOORS42" MIN.24" MIN. NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES 22". MIN. 54" MIN. PUSH SIDE 44" MIN.36" MIN. 60" MIN.PULL SIDE 48" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER HINGE APPROACH PUSH SIDE44" MIN.48" MIN.PULL SIDE LATCH APPROACH 24" MIN.*** 24" MIN. 22" MIN. 54" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER****30" MIN.48" MIN. 19" MIN. 30" MIN.19" MIN. 30" MIN.48" MIN.30" MIN. 42" MIN. ACCESSIBLE PATH OF TRAVEL HIGH FORWARD REACH 24MAX 34MAX. 46MAX.30 10"MAX 15" MIN48MAX.30 MAX. SIDE REACH OVER AN OBSTRUCTION HIGH AND LOW SIDE REACH LIMITS 15" MIN.48MAX.48MIN.48" MAX. 21". MAX. 48" MAX.48" MIN. MAXIMUM FORWARD REACH OVER AN OBSTRUCTION CLEAR FLOOR SPACE PARALLEL APPROACH CLOSETS 40" MIN.48" MAX.21". MAX. SHELVES NOTE: AT PASS THROUGH KITCHENS, A MIN. 40 INCH CLEAR PATH. AT 'U' SHAPED OR DEAD- END KITCHENS, 60 INCH MIN CLEAR. REACH DIAGRAMS APPLY TO EQUIPMENT AND REF/FREEZER 27" MIN.CLR.34" MAX.MINIMUM CLEARANCES FOR SEATING AND TABLES34" MIN44" MAX.48" MIN.27" MIN.CLR.34" MAX.MINIMUM MANEUVERING CLEARANCES IN ALCOVESX> 24"60" MINX> 15"4810 MAX. 30 MIN.3'-2"SCHEDULED FINISH FLOOR4'-6". . DOOR LEVER, PULL LIGHT SWITCH, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. (SEE PLAN FOR QUANTITY OF EACH CLUSTER) 6" RAISE/LOWER SWITCH THERMOSTAT, INTERCOM, OR 2ND ROW OF RECEPTACLES CENTER TO CLUSTER (WHEN USING DIMMERS, LOCATE THERMOSTAT AT OPPOSITE SIDE OF DOOR) SCHEDULED DOOR FRAME STROBE LIGHT AT CONFERENCE ROOMS ATYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, THERMOSTATS, ETC. TYPICAL WALL PANEL JOINT H TYPICAL LOCATION FOR POWER AND TELEPHONE OUTLETS AT WALL OR COLUMN POWER AND TELEPHONE RECEPTACLES, VERTICALLY MOUNTED, CENTERED BETWEEN PANEL JOINT SCHEDULED FINISH FLOOR1'-6" 6" EQ EQEQ EQ SCHEDULED FINISH FLOOR BTYPICAL LOCATION FOR WALL HUNG TELEPHONE (COORDINATE WALL OUTLET AT CL OF TELEPHONE) *NOTE: COORDINATE LOCATION OF OUTLETS WITH FINISH WALL PANEL JOINTS BEFORE SETTING OUTLETS IN GYPSUM BOARD/METAL STUD PARTITION I TYPICAL LOCATION FOR SINGLE WALL MOUNTED ALARM DEVICE/PULL SCHEDULED FINISH FLOOR 1'-6" 4'-0"WALL OUTLET WALL HUNG TELEPHONE SCHEDULED FINISH FLOOR CTYPICAL LOCATION FOR TWO WALL MOUNTED FIRE ALARM DEVICES/VISUAL ALARM TYPICAL LOCATION FOR CARD READER SCHEDULED FINISH FLOOR SCHEDULED FINISH FLOOR TYPICAL LOCATION FOR SWITCH ADJACENT TO DOOR SWING SCHEDULED FINISH FLOOR ALL OUTLETS ABOVE MILLWORK TO BE MOUNTED HORIZONTALLY *NOTE: REFER TO POWER PLAN FOR INDICATED MOUNTING HEIGHT EQ EQ 4'-0"MAX FINISHED CEILING 7'-0"MAX TO BOTTOM OF DEVICE 6"FINISHED CEILING 3'-2"1'-0" CARD READER, SEE ELECTRICAL PLANS 3'-2" 6" SCHEDULED DOOR & DOOR FRAME SWITCH SCHEDULED DOOR & DOOR FRAME 2'-10"MAX SCHEDULED MILLWORK 3'-6"TYPOUTLET DJ 11 LIGHT SWITCHES, DIMMERS, POWER AND TELEPHONE RECEPTACLES, ETC. CLUSTER, VERTICALLY MOUNTED E TYPICAL LOCATION FOR OUTLETS, SWITCHES, AND THERMOSTATS, ETC. AT CREDENZA OR COUNTERTOP2'-10"MAX3'-4"@ COUNTEREQ EQ SCHEDULED CREDENZA OR COUNTER SCHEDULED FINISH FLOOR F TYPICAL LOCATION FOR COMBINED OUTLETS AT VISIBLE AREAS *NOTE: PROVIDE MATCHING COVER PLATES FOR ALL SYSTEMS SCHEDULED FINISH FLOOR1'-6" 6" 6" VOICE AND DATA DOUBLE GANG 4"x4" BOXES (TYPICAL) KTYPICAL MOUNTING HEIGHT FOR FIRE EXTINGUISHER CABINET SCHEDULED FINISH FLOOR4'-6"TO TOP OF CABINETTYPICAL LOCATION FOR SWITCH ADJACENT TO SIDELITE SCHEDULED FINISH FLOOR3'-2"6" SCHEDULED DOOR, DOOR FRAME, & SIDELITE SWITCH G 7'-4"VARIES PER MFR, CONFIRM W/ ARCH8" ORIGINAL SHEET - ARCH E1 DATE: PRINT TIME STAMP:REVIEWED: DRAWN BY:COPYRIGHT © 2021 WALGREEN CO.WALGREENS11555 N. Meridian St.Carmel, IN 46032222702245AREA OFFICE - TWO PENN MARK - SUITE 140REVISIONSNO. DATE BY DESCRIPTIONLOC# 1397-1DESIGN PROJECT NO: Store Planning and Design Development106 Wilmot RoadDeerfield, IL 60015-5105224 S. Michigan Ave.STE 1400Chicago, IL 60604Tel: 312.554.1400 • www.stantec.comThe Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproduction oruse for any purpose other than that authorized by Stantec is forbidden.Copyright ReservedPermit/Seal KEY PLAN:100 % CONSTRUCTION DOCUMENT REVIEW2021.06.18ISSUE FOR BIDDING AND PERMIT2021.07.02Stantec Architecture and Engineering, LLC.1 ACCESSIBLE CORRIDORS AND TURNING 3/16" = 1'-0" 2 ACCESSIBLE DOOR CLEARANCES - SIDE APPROACH 3/16" = 1'-0" 3 ACCESSIBLE DOOR CLEARANCES - FRONT APPROACH 3/8" = 1'-0" 4 ACCESSIBLE CORRIDORS AND TURNING 3/16" = 1'-0" 2 ACCESSIBLE DOOR CLEARANCES - SIDE APPROACH 3/16" = 1'-0" 4 TYPICAL MOUNTING HEIGHTS 3/16" = 1'-0" G-003ACCESSIBILITY REQUIREMENTS & MOUNTING HEIGHTSA.SANCHEZ21.07.02B. STANKOSA.S.A.S.09/29/21