E001 - 310JGN
UP 33 33 3UP DN MEDIA ROOM UNFIN. STORAGE BEDROOM 5 CLO. BATH 7 W.I.C. LOUNGE WET BAR LINEN CS CS CS CS U.C. WINE COOLER U.C. REFR. GFI GFI GFI EJECT SUMP WS R.I. FURNACE PROVISION U.C. LIGHTS TO LIGHT ABOVE GFI SCONCE LIGHT EXERCISE MECHANICAL/STORAGE SCONCE LIGHT SCONCE LIGHT SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH SMOKE DETECTOR TELEPHONE JACK TV/ DATA EXHAUST FAN DUPLEX OUTLET WEATHER PROOF OUTLET GROUND FAULT OUTLET 220V OUTLET RECESSED EYEBALL LIGHTEYECEILING FIXTURE WALL MOUNT FIXTURE FLUORESCENT FIXTURE RECESSED FIXTURE TRACK FIXTURET UNDER CABINET FIXTURE EXTERIOR FLOOD LIGHT WIRE FOR PADDLE FAN WIRE FOR PADDLE FANAND LIGHT KIT CS34 WP GFI 220V FLUSH MOUNT LED FIXTURE CUSTOMER:PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:Wedgewood Building Co., LLC32 First Street NECarmel, IN 46032 317.669.6300 www.wedgewoodbc.com Copyright © 2021 Wedgewood Building Co. LLC. All rights reserved. This material may not bereproduced and/or modified without the expressprior written permission of the copyright holder. Forpermission contact gcradick@wedgewoodbc.com9/1/2021 4:22:19 PM E1KEEGAN-BEDANO RESIDENCE310 JGNV SPEC HOME545 Mendenhall DrLOWER LEVEL ELECTRICAL PLAN GHC 1/4" = 1'-0"3 LOWER LEVEL ELECTRICAL PLAN ELECTRICAL PLAN NOTES: 1. REFER TO COVER PAGE FOR SPANISH TRANSLATIONS = REFERIRSE A LA PORTADA DE LAS TRADUCCIONES AL ESPAÑOL.Rev.No. Date DescriptionBy Andrew Lund at 4:32 pm, Sep 01, 2021 09/28/21