Loading...
HomeMy WebLinkAboutPritzker, Matthew-ESS-Solar Drawing - Rev2 -8.05.2021MSP UM BLP ACD INV BAT 53'-5" 150'-9" 137'-0"125'-1"22'-7" 24'-3" 6'- 1 1 "46' -8" 13'-5"43'-3"REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 1 2 3 PROJECT DESCRIPTION: SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT PV-3 ATTACHMENT DETAIL PV-4 ELECTRICAL LINE DIAGRAM PV-5 WIRING CALCULATIONS PV-6 to 12 EQUIPMENT SPECIFICATIONS PLOT PLAN & VICINITY MAP HOUSE PHOTO VICINITY MAP SCALE: 1"=20'-0" PV-1 SCALE: NTSPV-1 PV-1 SCALE: NTS PROJECT SITE PLOT PLAN & VICINITY MAP EQUIPMENT SUMMARY 21 SILFAB SOLAR SIL-370 NX (370 WATT) MODULES 03 GENERAC PV LINK S2502 POWER OPTIMIZERS 01 GENERAC PWRCELL XVT076A03 (7.6kW) INVERTER AUTHORITIES HAVING JURISDICTION BUILDING : HAMILTON COUNTY ZONING : HAMILTON COUNTY UTILITY : DUKE ENERGY PROJECT SITE DESIGN SPECIFICATIONS OCCUPANCY : II CONSTRUCTION : SINGLE-FAMILY ZONING : RESIDENTIAL GROUND SNOW LOAD : SEE STRUCTURAL LETTER WIND EXPOSURE : SEE STRUCTURAL LETTER WIND SPEED : SEE STRUCTURAL LETTER 21 X 370 SILFAB SOLAR SIL-370 NX (370 WATT) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE:7.77 kW DC STC ARRAY AREA: ROOF#1 - 414.54 SQ FT APPLICABLE CODES & STANDARDS IRC 2020 NEC 2008 ROOF #1 (21) SILFAB SOLAR SIL-370 NX (370 WATT) MODULES TREES 1-STORY HOUSE (E) MAIN SERVICE PANEL (E) DRIVEWAY PROPERTY LINE PROPERTY LINEEDEN W A Y C I R C L E (E) FENCE 10/04/21 MSP UM BLP ACD INV BAT14'-9"SD 50'-0"3'-9"8'-11" 9'-7" 54'-5" 2'-4" 48'-5" REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 MODULE TYPE, DIMENSIONS & WEIGHT 1 ROOF PLAN & MODULES PV-2 ROOF PLAN & MODULES SCALE: 1"=10'-0" ROOF DESCRIPTION ROOF TYPE COMPOSITION SHINGLE ROOF ROOF TILT AZIMUTH FRAMING SIZE FRAMING SPACING #1 26.57° 188°SEE STRUCTURAL LETTER LEGEND - SOLADECKSD INV MSP - INVERTER - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT ACD - AC DISCONNECT - BACKUP LOAD PANELBLP - BATTERYBAT OP - PV LINK OPTIMIZER - RAPID SHUTDOWN72.13"39.4" SILFAB SOLAR SIL-370 NX (370 WATT) MODULES ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 21 414.54 960.85 43 (N) SOLADECK (N) 3/4" EMT CONDUIT (N) GENERAC PWRCELL XVT076A03 (7.6kW) INVERTER (N) FUSED AC DISCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL (N) BACKUP LOAD PANEL (N) GENERAC PWRCELL 9 BATTERY (N) GENERAC SNAP RS801 RS DEVICE ROOF #1 (21) SILFAB SOLAR SIL-370 NX (370 WATT) MODULES ON- SITE CUSTOMER APPROVAL: NUMBER OF MODULES = 21 MODULES MODULE TYPE = SILFAB SOLAR SIL-370 NX (370 WATT) MODULES MODULE WEIGHT = 44.0 LBS / 20.0 KG. MODULE DIMENSIONS = 72.13"x 39.4" = 19.74 SF UNIT WEIGHT OF ARRAY = 2.23 PSF (E) BACK OF R E S I D E N C E (E)FRONT OF R E S I DENCE EDEN WAY C I R C L E ROOF #1TILT - 26.57°AZIM. - 188° 10/04/21 MSP UM BLP ACD INV BAT SD OP OP OP REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2APOWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 1 ROOF PLAN WITH STRING LAYOUT PV-2A SCALE: 1"=8'-0" STRING LAYOUT BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 21 SILFAB SOLAR SIL-370 NX (370 WATT) MODULES OPTIMIZER 03 GENERAC PV LINK S2502 POWER OPTIMIZERS GENERAC SNAP RS 21 GENERAC SNAPRS MODEL RS801 INVERTER 01 GENERAC PWRCELL XVT076A03 (7.6KW) INVERTER AC DISCONNECT 1 60A FUSED, (2) 40A FUSES, 240V, NEMA 3R, UL LISTED SOLADECK 2 SOLADECKS 600 V, NEMA 3R, UL LISTED BATTERY 1 GENERAC PWRCELL 9 BATTERY BACKUP PANEL 1 125A, BACKUP PANEL, 240V RAILS 15 QRAIL LIGHT 14 FT. BLACK SPLICE KIT 4 QSPLICE INTERNAL LIGHT WEEB BMC 0 WEEB BMC MILL MODULE CLAMPS 28 UNIVERSAL MID CLAMP GROUNDING LUG 7 WEEB LUG W/ T-BOLT END CLAMPS 28 UNIVERSAL END CLAMPS ATTACHMENT 63 L-MOUNT ATTACHMENT (QUICKMOUNT) T-BOLT 66 T-BOLT W/ NUT M8 X 20MM (N) PV LINK OPTIMIZER - 1 (N) PV LINK OPTIMIZER - 2 (N) PV LINK OPTIMIZER - 3 (E) BACK OF R E S I DENCE EDEN WAY C I R C L E (E) FRONT OF R E S I DENCE 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 ATTACHMENT DETAIL 2 ATTACHMENT DETAIL (enlarged view) PV-3 SCALE: NTS 1 ATTACHMENT DETAIL PV-3 SCALE: 1" = 1'-0" PV MODULE (E) COMPOSITE SHINGLE ROOF SEE (2/PV-3) FOR ENLARGED VIEW HEX HEAD 5/16" X 4", 18-8 SS LAG SCREW 9"X12" QUICK MOUNT L-MOUNT FLASHING QUICK-MOUNT Q-RAILS QMR-RL14 (LIGHT) PV MODULE UNIVERSAL END/MID CLAMP (E) COMPOSITE SHINGLE ROOF OFFSET L-FEET SEE STRUCTURAL LETTER SEE STRUC T U R A L L E T T E R 10/04/21 PWRcell MODEL 9 BATTERY 8.6 kWh, 5.0 kW SILFAB SOLAR SIL-370 NX (370 WATT) MODULES 1 = = = = = = PVLINK SUBSTRING OPTIMIZER (S2502) RATED POWER : 2500W MPPT VOLTAGE RANGE: 60 TO 360 V MAX OUTPUT VOLTAGE: 420V MAX OUTPUT CURRENT: 8A RAPID SHUTDOWN COMPLIANT GROUND-FAULT PROTECTION COMPLIANT SNAP RS (RS801) MAX INPUT CURRENT - 13 A UL 1741 LISTED MODULE LEVEL RAPID SHUTDOWN (PVRSS) COMPLIANT NEMA 6P RATED JUNCTION BOX 600 V, NEMA 3 UL LISTED 2 1 2 + - + 3 + - - + - + - 6 7 1 2 + - + 3 +- - + - + - 6 7 1 2 + - + 3 +- - + - + - 6 7 3 GENERAC POWER CORE 50A/2-P30A/2-P 30A/2-P 30A/2-P 30A/2-P COMMUNICATION ROUTER GENERAC PWRCELL XVT076A03 (7.6kW) INVERTER (240V) OUTPUT: 32A, 240V 96.5% CEC WEIGHTED EFFICIENCY NEMA 3R RATED, UL 1741 LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT G N AC LOAD CENTER, 125 A RATED, 240/120, 1-PHASE 4 BACK UP LOADS UP TO 40A CIRCUIT 5 (E) MAIN BREAKER TO HOUSE 240 V, 200A/2P (TOP FED) NL2 L1 M LOAD LINE G G N SUPPLY SIDE TAPREF NEC 230.82(6), 705.12(A) FOR SUPPLY SIDE TAP EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF. NEC 250.52, 250.53(A) GEC (E) MAIN SERVICE PANEL,SQUARE D 200A RATED, 240V 6 AC DISCONNECT: 60A FUSED, (2) 40A FUSES, 240V NEMA 3R, UL LISTED REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-4 SCALE: NTS SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200A 200A SOUTH-WEST UNDERGROUND DUKE ENERGY SQUARE D PV ARRAY +VE CONDUCTOR AND L1 PV ARRAY -VE CONDUCTOR AND L2 NEUTRAL CONDUCTOR EGC AND GEC SINGLE TWISTED PAIR, CAT 5 WIRE WIRE LEGEND QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (6) #10AWG - PV WIRE/USE-2 N/A N/A(1) #6AWG - BARE COPPER IN FREE AIR (4) #10AWG - THWN-2 EMT OR FLEX IN ATTIC 3/4"(1) #6AWG - THWN-2 GND (2) #10AWG - THWN-2 EMT OR FLEX 3/4"(1) #10AWG - THWN-2 GND (3) #6AWG - THWN-2 EMT OR FLEX 3/4"(1) #6AWG - THWN-2 GND (3) #6AWG - THWN-2 EMT OR FLEX 3/4"(1) #6AWG - THWN-2 GND (3) #6AWG - THWN-2 EMT OR FLEX 3/4" 1 2 3 4 5 6 LABEL 7 AT MEP LABEL 9 AT UTILITY METER LABEL 8 AT MEP ! WARNING ! DUAL POWER SOURCES SECOND SOURCE IS PV SYSTEM ! CAUTION ! SOLAR POINT OF INTERCONNECTION ! WARNING ! SOLAR SYSTEM CONNECTED AND ENERGIZED LABEL 10 AT UTILITY METER ! WARNING ! THE SERVICE METER IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM LABEL 3 AT INVERTER LABEL 2 AT INVERTER LABEL 4 AT EACH DC DISCONNECT WARNING: PHOTOVOLTAIC POWER SOURCE LABEL 1 ON ALL CONDUITS SPACED AT MAX 10FT PHOTOVOLTAIC DC DISCONNECT ! CAUTION ! SOLAR ELECTRIC SYSTEM CONNECTED AND ENERGIZED ! CAUTION ! PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL 5 AT EACH AC DISCONNECT ! WARNING ! ELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC AC DISCONNECT LABEL 6 AT EACH AC DISCONNECT (21) SILFAB SOLAR SIL-370 NX (370 WATT) MODULES (3) PV LINKS OF 7 MODULES CONNECTED IN SERIES 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 WIRING CALCULATIONS INVERTER SPECIFICATIONS MANUFACTURER / MODEL #GENERAC PWRCELL XVT076A03 (7.6KW) AC POWER OUTPUT (LOADS/GRID) 7600VA AC POWER OUTPUT (BACKUP) 8000VA NOMINAL OUTPUT VOLTAGE 240 VAC MAX OUTPUT CURRENT @240V (LOADS/GRID) 32A MAX OUTPUT CURRENT @240V (BACKUP) 50A NOMINAL DC INPUT VOLTAGE 380Vdc MAX DC INPUT VOLTAGE 420Vdc CEC WEIGHTED EFFICIENCY 96.5% MAX DC POWER (PV) 10000W MAX INPUT CURRENT (PV) 20Adc CONT. PEAK POWER (BATTERY) 8000W SERIES SUB STRING OPTIMIZER SPECIFICATIONS MANUFACTURER / MODEL # PV LINK S2502 RATED POWER 2500W MPPT VOLTAGE RANGE 60-360 Vmp MAXIMUM INPUT VOLTAGE 420Voc MAXIMUM OUTPUT 420 Adc NOMINAL OUTPUT 380 Vdc MAXIMUM OUTPUT CURRENT 8 A MAXIMUM SHORT CIRCUIT CURRENT 18 A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -19° AMBIENT TEMP (HIGH TEMP 2%) 34° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 56° No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) CIRCUIT CONDUCTOR SIZE 1 6 AWG 3 TEMP. CORRECTION PER NEC TABLE 310.15(B)(2)(a) 0.96 75A EXPECTED WIRE TEMP (In Celsius) 34 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X INVERTER OUTPUT CURRENT (BACKUP POWER)42.5A DERATED AMPACITY OF CIRCUIT CONDUCTOR 72A Result should be greater than (42.5A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO BACK-UP PANEL: FROM BATTERY TO INVERTER: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) CIRCUIT CONDUCTOR SIZE 1 10 AWG 2 34 TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a) 0.96 CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE310.15(B)(16) 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X Imax 26.25A DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) 38.40A Result should be greater than (26.25A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO MEP: 1 CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) CIRCUIT CONDUCTOR SIZE 1 6 AWG 3 TEMP. CORRECTION PER NEC TABLE 310.15(B)(2)(a) 0.96 75A EXPECTED WIRE TEMP (In Celsius) 34 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X MAX INVERTER OUTPUT CURRENT (LOADS/GRID)40A DERATED AMPACITY OF CIRCUIT CONDUCTOR 72A Result should be greater than (40A) otherwise less the entry for circuit conductor size and ampacity 1 CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE BATTERY SPECIFICATIONS MANUFACTURER / MODEL #GENERAC PWRCELL 9 BATTERY USABLE ENERGY 8.6kWH RATED CONTINUOUS POWER 3.4kW POWER: 60 MINUTES 4.2kW POWER: 2 MINUTES 5.0kW REBUS VOLTAGE: INPUT/ OUTPUT 360-420Vdc MODULE VOLTAGE 46.8Vdc ROUND-TRIP EFFICIENCY 96.5% DC CONDUCTOR AMPACITY CALCULATIONS: PV LINK OPTIMIZER TO JUNCTION BOX: FROM JUNCTION BOX TO INVERTER: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) CIRCUIT CONDUCTOR SIZE 0.8 10 AWG 6 56 TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a) 0.71 CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X Imax 10A DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) 22.72A Result should be greater than (10A) otherwise less the entry for circuit conductor size and ampacity EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) CIRCUIT CONDUCTOR SIZE 0.8 10 AWG 4 56 TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a) 0.71 CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X Imax X # of PV LINKS 20A DERATED AMPACITY OF CIRCUIT CONDUCTOR TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) 22.72A Result should be greater than (20A) otherwise less the entry for circuit conductor size and ampacity SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # SILFAB SOLAR SIL-370 NX (370 WATT) VMP 37.2V IMP 10.0A VOC 44.8V ISC 10.6A TEMP. COEFF. VOC -0.28%/°C PTC RATING 342.21W MODULE DIMENSION 72.13"L x 39.4"W x 1.50"D (In Inch) 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11APOWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11BPOWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11CPOWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21 REV SHEET NAME SHEET SIZE SHEET NUMBERMATTHEW PRITZKERRESIDENCE3231 EDEN WAY CIRCLE, CARMEL, IN 46033ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12POWER HOME SOLAR, LLC"POWER YOUR FUTURE"919 N. MAIN ST.MOORESVILLE, NC 28115Phone: 704-800-6591 (OFFICE)Email: info@powerhome.comWeb: www.powerhome.comDATE: 8/5/2021 EQUIPMENT SPECIFICATION 10/04/21