HomeMy WebLinkAboutA010_WallTypesA010 WALL TYPES GENERAL WALL TYPE NOTES 1. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT TOILET ROOMS, KITCHENS, JANITORS CLOSETS, SINKS, OTHER SIMILAR LOCATIONS, AND ANY WALL WHICH IS TO RECEIVE A TILE FINISH. IF TWO LAYERS OF GYPSUM BOARD ARE INDICATED IN A WALL ASSEMBLY ONLY THE OUTSIDE LAYER NEED BE REPLACED WITH CEMENT BOARD. 2. METAL STUD CONTRACTOR TO DETERMINE GAUGE AND RELATED ENGINEERING OF METAL STUDS, TRACKS, BRIDGING, BLOCKING, KICKERS, FURRING, AND OTHER METAL FRAMING COMPONENTS. 3. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES. 4. WALL TYPES DO NOT INDICATE WALL FINISH MATERIALS IN ALL CASES. SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR ADDITIONAL FINISH INFORMATION. 5. PROVIDE ADDITIONAL LAYERS OF GYPSUM BOARD, BLOCKING, OR FRAMING AS NEEDED TO ACCOUNT FOR ALIGNING OF WALL TYPES OR FLUSH CONDITIONS. 6. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE. REFER TO WALL TYPES. 7. VERIFY FIRE RATINGS OF WALLS WITH FIRE RATING TABLE, LIFE SAFETY PLANS, AND OTHER NOTATIONS THROUGHOUT THE DRAWING SET. 8. PROVIDE IN-WALL BLOCKING FOR TENANT PROVIDED FF&E ITEMS. COORDINATE WITH TENANT. 9. REFER TO FINISH PLAN TO COORDINATE AREAS OF OF PLYWOOD SHEATHING REQUIRED FOR WOOD WALL PANELING 10. REFER TO ARCHITECTURAL FLOOR PLAN TO COORDINATE AREAS OF PLYWOOD SHEATHING REQUIRED FOR BLOCKING AND MOUNTING OF EQUIPMENT. SCALE: 1/2"=1'-0" WT-2 WALL TYPE2 SCALE: 1/2"=1'-0" WT-3 WALL TYPE3 SCALE: 1/2"=1'-0" WT-1 WALL TYPE1VARIESSEE REFLECTED CEILING PLAN5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORING 20 GA - 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" METAL RUNNER SCHEDULED CEILING SYSTEM WHERE APPLICABLE DECK EXISTING WALL. MAINTAIN ANY CONTINUOUS FIRE SEPARATIONS AS INDICATED ON THE LIFE SAFETY PLAN 20 GA - 6" METAL STUDS @ 16" O.C. SCHEDULED CEILING SYSTEM WHERE APPLICABLE 6" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) DECK 6" R19 UNFACED INSULATION IN STUD CAVITIES 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLAN20 GA - 3 5/8"" METAL STUDS @ 16" O.C. SCHEDULED CEILING SYSTEM WHERE APPLICABLE 3 5/8" METAL RUNNER BRACE TO STRUCTURE ABOVE AS REQUIRED (TYP) DECK 3-1/2" R11 UNFACED INSULATION IN STUD CAVITIES 5/8" GYP. BOARD SHEATHING ON FINISHED SIDE(S)(CEMENT BOARD IN AREAS OF TILE) ATTACHED WITH METAL SCREW FASTENERS SCHEDULED BASE SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLANWT-1A - WALL TYPE AS SHOWN WT-1B - WALL TYPE WITHOUT INSULATION WT-4A - WALL TYPE AS SHOWN WT-4B - WALL TYPE WITHOUT INSULATION Certified By:Scale:Date:Checked By:Drawn By:Revisions: Job Number: Drawing Number: Drawing Name:www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...LOE/BARREVIEW SET 08.26.2021 AMMLUXE LAB1200 S. RANGELINE RD., SUITE 102 CARMEL, IN 4603208/26/202110/06/21