HomeMy WebLinkAboutA010_WallTypesA010
WALL TYPES
GENERAL WALL TYPE NOTES
1. IN LIEU OF GYPSUM BOARD, PROVIDE CEMENT BOARD AT TOILET ROOMS, KITCHENS, JANITORS CLOSETS,
SINKS, OTHER SIMILAR LOCATIONS, AND ANY WALL WHICH IS TO RECEIVE A TILE FINISH. IF TWO LAYERS OF
GYPSUM BOARD ARE INDICATED IN A WALL ASSEMBLY ONLY THE OUTSIDE LAYER NEED BE REPLACED WITH
CEMENT BOARD.
2. METAL STUD CONTRACTOR TO DETERMINE GAUGE AND RELATED ENGINEERING OF METAL STUDS, TRACKS,
BRIDGING, BLOCKING, KICKERS, FURRING, AND OTHER METAL FRAMING COMPONENTS.
3. PROVIDE FIRE-SAFING AT EXPOSED WALL CAVITIES.
4. WALL TYPES DO NOT INDICATE WALL FINISH MATERIALS IN ALL CASES. SEE INTERIOR ELEVATIONS AND
FINISH SCHEDULE FOR ADDITIONAL FINISH INFORMATION.
5. PROVIDE ADDITIONAL LAYERS OF GYPSUM BOARD, BLOCKING, OR FRAMING AS NEEDED TO ACCOUNT
FOR ALIGNING OF WALL TYPES OR FLUSH CONDITIONS.
6. WALL FRAMING, SHEATHING, AND INSULATION TO EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF
DECK UNLESS NOTED OTHERWISE. REFER TO WALL TYPES.
7. VERIFY FIRE RATINGS OF WALLS WITH FIRE RATING TABLE, LIFE SAFETY PLANS, AND OTHER NOTATIONS
THROUGHOUT THE DRAWING SET.
8. PROVIDE IN-WALL BLOCKING FOR TENANT PROVIDED FF&E ITEMS. COORDINATE WITH TENANT.
9. REFER TO FINISH PLAN TO COORDINATE AREAS OF OF PLYWOOD SHEATHING REQUIRED FOR WOOD WALL
PANELING
10. REFER TO ARCHITECTURAL FLOOR PLAN TO COORDINATE AREAS OF PLYWOOD SHEATHING REQUIRED FOR
BLOCKING AND MOUNTING OF EQUIPMENT.
SCALE: 1/2"=1'-0"
WT-2 WALL TYPE2
SCALE: 1/2"=1'-0"
WT-3 WALL TYPE3 SCALE: 1/2"=1'-0"
WT-1 WALL TYPE1VARIESSEE REFLECTED CEILING PLAN5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(CEMENT BOARD IN
AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORING
20 GA - 3 5/8" METAL STUDS @ 16" O.C.
3 5/8" METAL RUNNER
SCHEDULED CEILING SYSTEM WHERE
APPLICABLE
DECK
EXISTING WALL. MAINTAIN ANY
CONTINUOUS FIRE SEPARATIONS
AS INDICATED ON THE LIFE
SAFETY PLAN
20 GA - 6" METAL STUDS @ 16" O.C.
SCHEDULED CEILING SYSTEM WHERE
APPLICABLE
6" METAL RUNNER
BRACE TO STRUCTURE
ABOVE AS REQUIRED (TYP) DECK
6" R19 UNFACED INSULATION
IN STUD CAVITIES
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLAN20 GA - 3 5/8"" METAL STUDS @ 16"
O.C.
SCHEDULED
CEILING SYSTEM WHERE
APPLICABLE
3 5/8" METAL RUNNER
BRACE TO STRUCTURE
ABOVE AS REQUIRED (TYP) DECK
3-1/2" R11 UNFACED
INSULATION IN
STUD CAVITIES
5/8" GYP. BOARD SHEATHING ON
FINISHED SIDE(S)(CEMENT BOARD
IN AREAS OF TILE) ATTACHED WITH
METAL SCREW FASTENERS
SCHEDULED BASE
SCHEDULED FLOORINGVARIESSEE REFLECTED CEILING PLANWT-1A - WALL TYPE AS SHOWN
WT-1B - WALL TYPE WITHOUT INSULATION
WT-4A - WALL TYPE AS SHOWN
WT-4B - WALL TYPE WITHOUT INSULATION
Certified By:Scale:Date:Checked By:Drawn By:Revisions:
Job Number:
Drawing Number:
Drawing Name:www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...LOE/BARREVIEW SET 08.26.2021 AMMLUXE LAB1200 S. RANGELINE RD., SUITE 102 CARMEL, IN 4603208/26/202110/06/21