HomeMy WebLinkAboutA400_ReflectedCeiling4'-6"
TYP
1'-4"
TYP4'-0"TYP2'-6"TYP1'-6"1'-6"EQ EQ
EX1
EM2
EM1
EM1
3'-6"4'-0" 4'-0" 4'-0" 4'-0" 6'-9" 6'-9"
5'-4 1/2"2'-6"2'-1" 4'-10"EM1
EM1
EM1
EM1
EM1
EM1
W2
EX1
R1
R1R1
R1
R1
R1 R1
R1 R1
R1R1
R1 R1
R1R1
R1 R1
P6
P6
P6
P6 P6
R2 R2
R2 R2
P6
P1
P6
P6
P6
P6 P6
P6
EQEQ
P6
EQEQ
P6 P6
L1
L1
P6
L1
L1
P6
P6
EM1
EX2
W1
EM1
L1
L1
P4
P3
P3
P6
DS
1'-6" L1
P6
OS
OS
OS
OS
UP
STAIR 3B SP6
P6
P6
P6
2'-0"
P6
S
PROJECT LIMITS PROJECT LIMITS
EP
P3 P3
1'-11"
2'-1"
2'-2" 5'-8" 5'-8" 3'-0"CLOSET
101
RESTROOM
102
SHAMPOO
104
ROOM 1
105
PRIVATE
ROOM 2
106
ROOM 3
107
ROOM 4
108
BREAK ROOM
109
100
OFFICE
110
LOBBY
103
PRIVATE
PRIVATE
PRIVATE
3'-8 1/2"5'-2 1/2"
1'-6"
TYP
8"P3 P3 P3 P3
P6
P6
P6 P6
P6P6 P6
P6
P6
EQ EQ
1'-6"EQ EQ
2'-2"
R1
P6
EQ EQEQ
EQ 2'-0"P6
4'-0"4'-0" 4'-0" 5'-0"P5 P5
W2
W2
W2
+XX"
+XX"
+XX"
+XX"1'-4" 4'-10" 3'-8 1/2" 3'-8 1/2" 4'-4" 2'-0" 1'-8"EQ 3'-8" EQP6P6 EQEQ R1
1'-0"
RESTROOM
111
P2
2'-4"5'-5"
P6
4'-8"STYLING
W1
W3
W4
W4
W4
W4
W4
8'-6"8'-8"
+XX"
+XX"
+XX"
+XX"
+XX"
P2
P2
5'-5"
NL
NL
3S
S SD
SDSD
2'-3"
SD
S DSD
SD S SS
SDSD
SDSD SD
SD
D
DS
DSDS
DS DS
SD DSSD
P6
3'-8 1/2"
SCALE: 1/4" = 1'-0"
1 REFLECTED CEILING PLAN
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
PROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS.
THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING
HEIGHT AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND
OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY
SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE
COMMENCEMENT OF ANY WORK.
CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS, AND STATE AND LOCAL BUILDING CODES.
ALL DIMENSIONS ARE FROM CENTERLINE TO CENTERLINE OF FIXTURES.
ALL GYP. BOARD WALLS, CEILINGS AND BULKHEADS, SHALL BE A SMOOTH LEVEL 4 FINISH AS
OUTLINED IN GYPSUM ASSOCIATION GA-214.
ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF
SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. CONFIRM ALL NEW
SWITCH LOCATIONS WITH OWNER PRIOR TO ROUGH-IN. COLOR: WHITE UNLESS OTHERWISE NOTED.
ALL MATERIALS EXPOSED WITHIN THE PLENUM MUST BE NONCOMBUSTIBLE OR SHALL COMPLY WITH
LABELING, FLAME AND SMOKE DEVELOPMENT RATINGS AS SPECIFIED IN THE CURRENT EDITION OF
THE INDIANA MECHANICAL CODE.
MEANS OF EGRESS ILLUMINATION SHALL BE LOCATED IN ACCORDANCE WITH SECTION 1006, IC
(675 IC 13-2.5).
LIFE SAFETY DEVICES SHOWN FOR REFERENCE ONLY. LIFE SAFETY CONTRACTOR TO VERIFY LIFE
SAFETY DEVICES MEET ALL APPLICABLE CODES.
MECHANICAL DEVICES SHOWN FOR LOCATION ONLY. ALL MECHANICAL DEVISES TO MATCH THE
ADJACENT SURFACE. CONFIRM COLOR SELECTION WITH ARCHITECT. SEE MECHANICAL
DRAWINGS.
X'-X" A.F.F.
S
OS
HEIGHT INDICATION ABOVE FINISHED FLOOR
SINGLE POLE SWITCH
OCCUPANCY SENSOR: PROVIDED AND INSTALLED BY CONTRACTOR TO MEET
ALL REQUIREMENTS OF THE 2010 INDIANA ENERGY CONSERVATION CODE
SWITCHING INTENT
NEW LED EDGE-LIT EXIT SIGN W/ BATTERY BACKUP: EVENLITE,
SOVEREIGN W/ GREEN LETTERS, OR APPROVED EQUAL
NEW EMERGENCY LIGHT: SURE-LITES, APEL SERIES W/ WHITE FINISH, OR
APPROVED EQUAL.
NEW LED EDGE-LIT EXIT SIGN W/ DOUBLE ARROW CHEVRON DIRECTION
(<EXIT>): EVENLITE, SOVEREIGN W/ GREEN LETTERS, OR APPROVED EQUAL.
LINEAR LED STANDARD OUTPUT TAPELIGHT: MFG: CONTECH LIGHTING, 73
LM/FT, 0.7W/ FT, 3000K, OR APPROVED EQUAL. CONTRACTOR TO VERIFY
QUANTITY TO FILL ENTIRE LENGTH REQUIREMENTS PRIOR TO ORDER.
RECESSED LED DOWN LIGHT: LITELINE 5"/6" LUNA PRO LED ROUND
RECESSED FIXTURE, RA56-20F-90WHWH-3000K, DIMMABLE; WHITE W/
WHITE REFLECTOR, 20W INTEGRAL, 1435 LUMENS 3000K
PENDANT MOUNT LED DOWN LIGHT: A LINE BY LITELINE FLEX 15
CYLINDER FIXTURE, A-FLX15-3060P-WH-N-RX, DIMMABLE; WHITE W/
WHITE REFLECTOR, ROD X' (CONFIRM FINAL MOUNTING HEIGHT)15W,
60 DEGREE BEAM, 1280 LUMENS 3000K
P1: NEW INCANDESCENT PENDANT: 73"DIA X 42.5"H, LACQUERED
BURNISHED BRASS FINISH, (36) 15W E12 CANDELABRA, VERIFY
FINAL MOUNTING HEIGHTS WITH OWNER.
P4: NEW LED PENDANT: 50" DIA X 8.25"H, SOFT BRASS WITH WHITE SHADES; (6)
6W LED, 2700K, VERIFY MOUNTING HEIGHT WITH OWNER.
P3: NEW LED PENDANT: RENWIL ROBIN CHANDELIER, SATIN BRASS PLATED
FINISH, MILKY GLASS SHADE; (4) 3.5W G9 SOCKET (BULBS INCLUDED),
COORDINATE WITH AND CENTER ON STYLIST STATIONS BELOW. VERIFY
MOUNTING HEIGHT WITH OWNER.
W2: NEW LED SCONCE: ANTIQUE BURNISHED BRASS AND ALABASTER,
9W LED INTEGRATED
NOTE: FIXTURES BELOW TO BE PROVIDED AND INSTALLED BY CONTRACTOR
NOTE: FIXTURES BELOW TO BE PROVIDED BY PHANOMEN/design AND
INSTALLED BY CONTRACTOR
Certified By:Scale:Date:Checked By:Drawn By:Revisions:
Job Number:
Drawing Number:
Drawing Name:www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...LOE/BARPERMIT SET 08.26.2021 AMMLUXE LAB1200 S. RANGELINE RD., SUITE 102 CARMEL, IN 4603208/26/2021GENERAL REFLECTED CEILING NOTES REFLECTED CEILING LEGEND
KEYED REFLECTED CEILING PLAN NOTES
GYP. BULKHEAD AT 8'-0" A.F.F. PAINT FACE OF BULKHEAD TO MATCH ADJACENT WALL. DESIGN INTENT IS FOR BULKHEAD
TO BE 1" PROUD OF THE FACE OF THE CASEWORK BELOW.
INSTALL PHANOMEN PROVIDED ACUFELT CEILING CLOUDS. DESIGN INTENT IS FOR CEILING CLOUDS TO BE INSTALLED AS
HIGH AS POSSIBLE BELOW HVAC, COORDINATE WITH PHANOMEN.
ALIGN FINISHED FACES.
IN ALL AREAS EXPOSED TO DECK, CONTRACTOR TO PAINT EXPOSED CONDUIT AND DUCTWORK TO MATCH PAINTED
EXPOSED CEILING ABOVE.
LANDLORD TO PROVIDE FULLY FUNCTIONAL SIGN CIRCUIT AND J-BOX TYING INTO THE BUILDING ELECTRICAL PANEL.
NON-ILLUMINATED SIGNAGE. COORDINATE WITH TENANT.
'P3' PLACEMENT TO BE COORDINATED WITH MIRROR PLACEMENT IN STYLIST STATIONS BELOW TO AVOID CONFLICT.
'W4' SCONCE PLACEMENT TO BE COORDINATED WITH RETAIL SHELVING.
INSTALL GARBAGE DISPOSAL SWITCH AT THIS LOCATION, VERIFY FINAL LOCATION WITH CABINETRY ELEVATION.
INSTALL RETAIL SHELVING SWITCH AT THIS LOCATION. VERIFY REQUIREMENTS WITH CABINETRY SHOP DRAWINGS AND
SPECIFICATIONS.
X
1
1
1
1
1
EX DECK
2
2
3
3
3
W1: NEW SCONCE: AGNED BRASS W/ EXTRUDED JADE AND OPAL
GLOSSY SHADE, 8W LED
+ XX" MOUNTING HEIGHT TO CENTER ABOVE FINISHED FLOOR
S DIMMER SWITCH
D
OS NIGHT LIGHT FIXTURE
4
P5: NEW LED PENDANT: 45"W x 13"H x 11" D, AGED BRASS WITH GLASS ; 48W
LED, VERIFY MOUNTING HEIGHT WITH OWNER.
P2: NEW LED PENDANT: 6 ARM, AGED BRASS WITH GLASS ORBS, (12) 6W LED
3000K, VERIFY MOUNTING HEIGHT WITH OWNER.
CEILING FINISHXXXX
1
TYP 4
4
EX DECK
PT-X
10'-0" A.F.F.
PT-X
10'-0" A.F.F.
PT-X
10'-0" A.F.F.
PT-X
10'-0" A.F.F.
PT-X
10'-0" A.F.F.
PT-X
10'-0" A.F.F.NSW E5
NEW EXHAUST FAN, NO LIGHT. MINIMUM SONE LEVEL 2, PROVIDE
SPECIFICATIONS TO DESIGN FOR APPROVAL PRIOR TO ORDER.
VENT TO EXTERIOR AS REQUIRED.
PT-X
9'-0" A.F.F.
6
6
7
7
TYP
8
8
TYP
W3: NEW INCANDESCENT SCONCE: 23.25"W X 6.5"H X 11"D, BRASS
FINISH, (3) 40W G19
W4: NEW INCANDESCENT SCONCE: 27"W x 6.3" D x 16.5" H,
BLACKENED BRONZE, 9W LED Type A
NL NIGHT LIGHT FIXTURE
S 3-WAY DIMMER SWITCH
3
9
9
10
10
TYP
EX DECK
TYP
TYP
TYP
EM1:
EX1:
EX2:
L1:
R1:
P6:
EXH:AS NOTEDREFLECTED CEILING PLAN
A400
10/06/21