HomeMy WebLinkAboutA000_Review Set_08.26.21 COVER SHEET
A000
LUXE LAB
1200 S. RANGELINE RD. , SUITE 102
CARMEL, IN 46032
DRAWING INDEX
ARCHITECTURAL/INTERIOR
A000 COVER SHEET
A001 GENERAL NOTES & SYMBOLS
A002 LIFE SAFETY PLAN
A010 WALL TYPES
A100 ARCHITECTURAL FLOOR PLAN & DOOR SCHEDULE
A105 ENLARGED RESTROOM PLANS & DETAILS
A200 INTERIOR ELEVATIONS
A400 REFLECTED CEILING PLAN, SCHEDULE & NOTES
A700 FINISH PLAN
A800 FURNITURE PLAN
ELECTRICAL
E1.1 ELECTRICAL SCHEDULE AND NOTES
E1.2 ELECTRICAL POWER PLAN
E1.3 ELECTRICAL LIGHTING PLAN
E1.4 ELECTRICAL SPECIFICATIONS
MECHANICAL
M1.1 MECHANICAL PLAN
M1.2 MECHANICAL SCHEDULES
M1.3 MECHANICAL SCHEDULES
M1.4 MECHANICAL DETAILS
PLUMBING
P1.1 PLUMBING PLAN-WASTE
P1.2 PLUMBING PLAN-WATER
P1.3 PLUMBING RISER DIAGRAM
P1.4 PLUMBING DETAILS
INTERIOR DESIGN:
PHANOMEN/ design
934 FT. Wayne Ave.
Indianapolis, IN 46202
(317) 439-4355
LOREE EVERETTE
PROJECT TEAM
COURTESY OF GOOGLEPROJECT LOCATION
BUILDING CODE:
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE: 675 IAC
13-2.6)
PLUMBING CODE:
2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE: 675 IAC
16-1.4)
ELECTRICAL CODE:
2009 INDIANA ELECTRICAL CODE (2008 NFPA-70: 675 IAC 17-1.8)
MECHANICAL CODE:
2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL
CODE: 675 IAC 18-1.6)
FIRE / LIFE SAFETY CODE:
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE: 675 IAC 22-2.5)
ACCESSIBILITY CODE:
2008 INDIANA BUILDING CODE CHAPER 11 - ACCESSIBILITY (675 IAC 13-2.5-12
CHAPTER 11)
ENERGY CODE:
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1, 2007 EDITION: 675 IAC
19-4)
ELEVATOR CODE:
2011 INDIANA ELEVATOR SAFETY CODE (ANSI/ASME A17.1, 2007 EDITION: 675 IAC
21-3)
GAS CODE:
2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE: 675 IAC
25-3)
APPLICABLE CODES
SCALE: N/ASCALE: N.T.S.
VICINITY MAP
A000
1
N
S
W E
PROJECT
LOCATION
SCALE: N.T.S.
VICINITY MAP
A000
2
N
S
W E
GENERAL FIRE PROTECTION NOTES
RENOVATED AREAS SHALL BE 100% SPRINKLERED.A.
COORDINATE CLOSELY WITH OTHER TRADES. REFER TO ARCHITECTURAL DRAWINGS
FOR CEILING TYPES.B.
ALL SPRINKLER WORK SHALL BE INSTALLED PER NFPA 13, BUILDING CODE, AND
OWNER'S INSURANCE CARRIER REQUIREMENTS.
C.
MAKE PROVISIONS FOR THE DRAINING AND PROVIDE INSPECTOR TESTS AS
REQUIRED, ALL DRAIN PIPING SHALL BE PIPED TO OUTSIDE OR INDIRECTLY TO SINK
OR FLOOR DRAIN.
D.
COORDINATE EXACT LOCATION OF PIPING AND HEADS WITH REFLECTED CEILING
PLANS, MECHANICAL AND ELECTRICAL DRAWINGS.E.
ALL HOSE VALVES AND FIRE DEPARTMENT CONNECTIONS SHALL MATCH LOCAL
FIRE DEPARTMENT THREADS.
F.
ALL FIRE SUPPRESSION WORK SHALL BE PERFORMED BY A FIRE PROTECTION
CONTRACTOR LICENSED IN THE STATE OF INDIANA.
G.
ALL SPRINKLER HEADS SHALL BE LOCATED IN CENTER OF CEILING TILE IN AT LEAST
ONE DIRECTION.
H.
SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING
FOR SPRINKLER WORK IN ALL AREAS OF BUILDING. REFER TO SPECIFICATIONS.
I.
ALL ARMOVER PIPING RELATED TO SPRINKLERS TO BE DEMOLISHED ARE TO
REMOVED BACK TO THE OUTLET ON THE BRANCHLINE.
J.
WHEN MODIFYING EXISTING SPRINKLER SYSTEMS, SPRINKLER CONTRACTOR SHALL
MAINTAIN THE INTEGRITY OF THE EXISTING SPRINKLER ZONES. COORDINATE WITH
NEW FIRE RATING PLANS IF APPLICABLE.
K.
FIRE PROTECTION CONTRACTOR IS REQUIRED TO RAISE/REWORK ALL EXISTING
PIPING AS NEEDED TO ACCOMMODATE NEW CEILINGS AND HIGHER CEILING
HEIGHTS AS APPLICABLE.
L.
MEP:
KDC CONSULTING
(317) 501-3544
KEVIN CONRAD
Certified By:Scale:Date:Checked By:Drawn By:Revisions:
Job Number:
Drawing Number:
Drawing Name:www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202317.439.4355 (t)...creating profitable environments...LOE/BARREVIEW SET 08.26.2021 AMMLUXE LAB1200 S. RANGELINE RD., SUITE 102 CARMEL, IN 4603208/26/202110/06/21