Loading...
HomeMy WebLinkAboutA0.5 Lower Level PlanTTRASH CHUTE + HOLDING AREA PARKING PARKING ELEV. UP TRASH CHUTE + HOLDING AREA 8' - 0" 8' - 0"8' - 0"8' - 0" A0.5 2 A0.5 B 1 2 6 13' -0" CLG. HT Verify clear height in field 4 5 2 TYP 3 6" dia. schedule 40 steel post filled with concrete, painted yellow Finish top with metal bowl inverted to shape top uniform bowl finish, typ. To prevent cracking in slab wrap pipe with (3) layers of 30# felt paper from 2" above T.O. slab down to T.O. footing. Cut off excess felt above slab after cure Break bond between slab and footing with gravel, plastic, sand or felt18" dia. concrete footing Concrete slab 3' - 6" 3' - 6"6"© 2021 - All Rights Reserved. No portion(s) of this document may be reporoduced without written approval of Design CollectivePROJECT NO. INITIAL ISSUE DATE REVISIONS PROJECT STATUS 8/5/2021 3:57:47 PM A0.5 Lower Level Plan 1090.02 The Proscenium Building 31200 S. Rangeline Rd., Carmel INJune 4, 2021 For Permit OWNER TJKKitchens&Brewpubs 4022 North Hampton Dr. Powell, OH 43065 Tel: 614-406-3905 Email: thad@101beerkitchen.com ARCHITECT Design Collective Architecture 151 East Nationwide Blvd. Columbus, OH 43215 Tel: 614-464-2880 Email: mtoddy@dcollective.com STRUCTURAL ENGINEER Jezerinac Geers & Associates 5640 Frantz Rd. Dublin, OH 43017 Tel: 614-766-0066 Email: dschoeff@jgaeng.com MEP ENGINEER Prater Engineering 6130 Wilcox Rd. Dublin, OH 43016 Tel: 614-766-4896 Email: bcaines@praterengr.com GENERAL CONTRACTOR Capitol Construction Services, Inc. 11051 Village Square Lane Fishers, IN 46038 Tel: 317-574-5488 Email: kschott@capitolconstruct.com LANDLORD Novo Development Group 1215 S. Rangeline Rd. Carmel, IN 46032 Tel: 317-708-9400 Email: thill@novo.dev Contact: Thad Kittrell Contact: Matt Toddy Contact: Dave Schoeff Contact: Billy Caines Contact: Kevin Schott Contact: Tim Hill Scale: 1/8" = 1'-0" Parking GarageNORTH GENERAL NOTES - SCHEMATIC PLAN Scale: 1/4" = 1'-0" A -Enlarged Plan Scale: 1/4" = 1'-0" B -Enlarged PlanNORTH NORTH 1 Dashed lined indicates extents of building above. 2 Hatched region indicates area reserved for HVAC equipment. Refer to MEP drawings. 3 Steel bollards as indicated. Refer to typical detail. Coordinate final quantity and location with Landlord. 4 Dashed line indicates extents of trash chute above. 5 Refer to MEP and equipment plans for equipment layout. 6 Existing grease interceptor cleanout line. Verify location and notify Architect immediately of any discrepancies. KEYNOTES - LOWER LEVEL 1. Do not scale drawings. If dimensions are in question, the contractor shall be responsible for seeking clarification from Architect prior to construction. 2. All dimensions are from finished surface to finished surface, unless noted otherwise. DETAIL - BOLLARD #Description Date 10/06/21