Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A3 Reflected Ceiling Plan wo Seating
A AA A A A A A C TH TH TH TH TH TH TH TH TH TH TH TH TH TH TH TH C C B B B B B B B B B T8c T8c T8c E EE T8c T8c T8c T8c TH TH TH TH TH TH TH TH TH TH TH TH TH TH TH TH T8c T8c T8c T8c TH TH TH TH TH TH TH TH TH TH TH TH B B B BB B B B F F F F F F H GG G G J M M M M M M M M MM M M M M M M M M M M M M M M M M M M M M L L L L L L L L M M M M M M M M M M M M M L Above 0'-0"11' - 0" Above 0'-0"11' - 0" Above 0'-0"11' - 0" Above 0'-0" 11' -0" Above 0'-0"11' - 0"Above 0'-0" 11' - 0"Above 0'-0"11' - 0"Above 0'-0"11' -0"Above 0'-0"11' - 0" Above 0'-0"10' -0" Above 0'-0" 10' -0" Above 0'-0"10' -0" Above 0'-0"9' - 6" Above 0'-0"8' - 6" Above 0'-0"10' - 0" 10' - 9" 10' - 8 1/2" 9' - 10" 10' - 8 1/2" 10' - 8 1/2" 10' - 8 1/2" 10' - 8 1/2" 10' - 8 1/2" 10' - 8 1/2" 10' - 8 1/2"10' - 8 1/2"10' - 8 1/2"10' - 8 1/2" 10' - 8 1/2" 10' - 8 1/2" 9' - 10" 32°30°28°12'-4"6'-9" 5'-9" 5'-9" 5'-9" J J J J J J J J N N N N P P P P H H Host 102 Bar Dining 107 East Dining 106 Northeast Dining 109 North Dining 110 Corridor 103 Restrooms 105 Vestibule 101 Expo 112 Trash 120 Office 118 Vestibule 104 Cooler 116 Cooler 117 Dish Room 114 Bar Service 108 Patio 122 Patio 121 Northwest Dining 111 Line 113 Prep 115 BOH 119 17 17 17 17 17 17 55 6 6 6 TYP 16 20 20 20 20 20 14 6 TYP 16 2 12 16 2 12 TYP 9 16 1 9 4 1 6 6 6 17 17 17 16 6 2 12 6 6 6 6 6 6 7 7 TYP 13 TYP 14 15 8 8 19 3 14' - 5" 11' - 0" 14' - 5" 9' - 6" 3 TYP 18 TYP 18 TYP 18 O 11 711 6 6 6 6 6 D C-4 C-2 C-2 C-2 C-2 C-2 C-2 C-2 C-2 C-2 C-2 C-2 C-2 PT-3 M-4 M-3 M-1 M M M M-1 M-3M-3 M-3 M-3M-3 M-3M-3 M-3 M-3 M-3 M-3PT-1PT-1 C-4 C-4 PT-3 PT-3 PT-3 PT-3 3 3 3 TYP 16 16 16 O O O2' - 3" 4' - 6" 2' - 3"EQ EQ EQ EQ 1' - 6 3/8" 5' - 10 3/8" 2' - 0" EQ. V.I.F. 7' - 6 3/4" EQ. Above 0'-0"9' - 6" Above 0'-0"9' - 6" Above 0'-0"9' -6" Above 0'-0"9' - 6" 9' - 0" 9' - 0" Above 0'-0"9' -6" 9' - 0 1/8" 11' - 5 3/8" V.I.F.11' - 5 1/8" V.I.F. 12' - 2 1/4" V.I.F. 10' - 8 1/2" 11' - 11 1/2" V.I.F. 21 16'-9 1/2" 11'-10 1/4" 10'-11" 12'-0"2'-4 3/4"13'-8" 6'-8" 6'-8" GG G GG G G G G GG G J J J G GG G GG G G G G 16'-2" J J J J H HH G G 1/4" allthread to structure above (paint black) Unistrut A1000 (paint black) Track mounted to unistrut Track lights as specified Refer to schedule for elevation© 2021 - All Rights Reserved. No portion(s) of this document may be reporoduced without written approval of Design CollectiveArchitect, License # Expiration Date: December 31, 2021 PROJECT NO. INITIAL ISSUE DATE REVISIONS PROJECT STATUS 8/5/2021 3:58:34 PM A3 Reflected Ceiling Plan w/o Seating 1090.02 The Proscenium Building 31200 S. Rangeline Rd., Carmel INJune 4, 2021 AR11900062 For Permit OWNER TJKKitchens&Brewpubs 4022 North Hampton Dr. Powell, OH 43065 Tel: 614-406-3905 Email: thad@101beerkitchen.com ARCHITECT Design Collective Architecture 151 East Nationwide Blvd. Columbus, OH 43215 Tel: 614-464-2880 Email: mtoddy@dcollective.com STRUCTURAL ENGINEER Jezerinac Geers & Associates 5640 Frantz Rd. Dublin, OH 43017 Tel: 614-766-0066 Email: dschoeff@jgaeng.com MEP ENGINEER Prater Engineering 6130 Wilcox Rd. Dublin, OH 43016 Tel: 614-766-4896 Email: bcaines@praterengr.com GENERAL CONTRACTOR Capitol Construction Services, Inc. 11051 Village Square Lane Fishers, IN 46038 Tel: 317-574-5488 Email: kschott@capitolconstruct.com LANDLORD Novo Development Group 1215 S. Rangeline Rd. Carmel, IN 46032 Tel: 317-708-9400 Email: thill@novo.dev Contact: Thad Kittrell Contact: Matt Toddy Contact: Dave Schoeff Contact: Billy Caines Contact: Kevin Schott Contact: Tim Hill Scale: 1/4" = 1'-0" Reflected Ceiling Plan 1 Wall-mounted TV with fully articulated adjustable arm. Provide blocking as required. Provide cable and power on wall behind. Refer to electrical drawings. Refer to elevations for mounting heights. 2 Provide Owens Corning Select Sound 1" mat-faced acoustical boards on all exposed deck surfaces between steel structure. Align fasteners both directions. Color: black. 3 Signage as indicated. Refer to details. 4 Back bar. Refer to elevations and details for light fixtures within. 5 Provide operable roller shades on inside of existing storefront. Screen and housing to be black. 6 Center fixture over table below. 7 Kitchen hood. Refer to FSE and mechanical drawings. 8 Walk-in cooler/freezer. 9 Dashed line indicates continuous tape light. Refer to details for mounting locations. 10 Double element radiant heater mounted to underside of patio structure. 11 Hatched area indicates location of aluminum lay-in ceiling panels painted to match adjacent tiles. 12 Existing steel framing, decking, and fireproofing to remain. Patch/repair any disturbed fireproofing throughout all phases of construction. Paint as indicated. 13 2x12 FRT joists at 16”o.c. Set underside at 12’-0” AFF. Refer to elevations. 14 Wall sconces mounted to millwork wall. Refer to elevations for details. 15 Custom neon signage element. GC to provide electrical connections as required. Coordinate installation with Architect and Owner. 16 6”x20GA box beam wrapped in veneer plywood to match M-01. Reer to details. 17 Ceiling finish as indicated over 3 ⅝”x20GA ceiling joists at 16”o.c. with bridging lines at 4’-0” intervals along span, typ. 18 Exit signage. Refer to MEP drawings. 19 HVAC intake louver this location. Refer to MEP drawings. 20 Provide wiring for Fixture , cap and do not install fixture at this location. 21 Future adjacent tenant exhaust ductwork. Coordinate with Landlord in field. NORTH FOR COORDINATION ONLY; REFER TO ELECTRICAL PLANS. Mounting heights listed are to bottom of fixture for ceiling mounts, and center of J-box for wall mount Type Description Manufacturer Model Type Mounting Height A Wall Sconce Troy Lighting Smyth B6392; 10"W x 17.50"H Amber LED Wall mounted at 7'-4" O.C. B Pendant (Restroom) Restoration Hardware 20th C. Factory Filament Metal Single Pendant Finish: Polished Nickel Edison C Pendant (Ceiling RLM) Restoration Hardware Vintage Barn Pendant, 22" Bronze A19 LED D Pendant (Ceiling RLM) Restoration Hardware Vintage Barn Pendant, 26" Bronze A19 LED E Chandelier Capitol Lighting 20 Light Chandeliere 60"W; Black Iron T6 Incandesce nt Ceiling mounted at 9' - 0" A.F.F. F Picture Light Lamps Plus Contemporary 24" Polished Brass Direct Wire Picture Light, dimmable T10L G Downlight - Patio (Adjustable) Focus Industries DL-20-NL-BLT PAR20 H Infrared Radiant Heater Infratech WD6024 - J String Lights (Patio) Tokistar 'Exhibiter Series' mount to 1/8" black wire rope 12" O.C. Lights; #EX-BK-12-VI-G19-C Wire Rope Adapters; #EX-MDA-BK LED Mount ends at underside of structure. Drape center point of string at 9'-0" AFF L 2'X4' Flurescent (Lensed Troffer) Columbia Lighting JT824-332G-FSA12-3EU 32T8 M Downlight (Pinhole, Black) Contech Refer to MEP N Wall Sconce Golden Lighting (Lightology) Tribeca Wall Sconce - Aged Brass/Black E26 Incandesce nt O LED Striplight ConTech Lighting TLT-12V-2-27K length/quantities vary. P Wall Sconce ED by Ellen Degeneres Jane Wall Sconce, Midnight Balck T8c Track - 8' (Ceiling Mounted) ConTech Lighting LT-8-B (Black) Ceiling Mounted TH Track Head ConTech Lighting CTL1216T-B MR16 n/a SCHEDULE - LIGHT FIXTURES SCHEDULE - CEILING FINISHES KEYNOTES - REFLECTED CEILING PLAN Type Description Manufacturer Model Comments C-1 Paint (Dryfall) Sherwin Williams Kem Bond HS/Pro Industrial waterborne acrylic dryfall flat. Color: #SW7069 'Iron Ore'. One coat primer, 2 coats finish. Paint deck and all exposed structural members C-2 Wood Panel By Contractor Wood shiplap ceiling panel as shown to match Architect's sample. ProMar 200 Latex Flat. Color: #SW7015 'Repose Gray'. Thin paint and apply as a wash with wood grain showing through. C-3 Ceiling Tile (2x4) USG Sheetrock brand Clima Plus 3270; 2x4x½" Donn DX 15/16" grid to match C-4 Paint Sherwin Williams ProMar 200 Latex EgShell/ Preprite 200 Primer; Color: #SW7015 'Repose Gray' One coat primer, 2 coats finish: EgShell 1. Do not scale drawings. If dimensions are in question, the Contractor is responsible for seeking clarification from Architect prior to construction. 2. All dimensions are from finished surface to finished surface, unless noted otherwise. 3. Architectural reflected ceiling plans are for the purpose of indicating the design intent only. Indicated location of HVAC diffusers, return air grilles, light fixtures, etc., are shown only for coordination of these items with the architectural design elements. Refer to Engineer's drawings for specifications and exact locations of these items. If discrepancies between the engineering drawings and architectural drawings are discovered, Contractor shall notify Architect for clarification prior to installing work in question. 4. Ceiling grid layout is to be centered both ways in rooms or spaces unless noted otherwise. 5. HVAC diffusers and return air grilles are to be centered between light fixtures unless noted otherwise. 6. The Contractor shall provide access panels, where equipment requiring access is located above finished, non- accessible ceilings. Match access panel to adjacent finish. Coordinate specific access panel details with Architect. 7. Do not install light fixtures lenses or remove protective plastic film until carpet has been installed and vacuumed. 8. Install acoustical ceiling panels with grain/texture running in the same direction unless indicated otherwise. 9. If acoustical ceiling panels have been specified, Contractor shall include an allowance to provide Owner with a five percent attic stock of each panel type used on the project, in unopened cartons for maintenance and replacement use. Verify actual quantity with Owner prior to order. 10. Gypsum board ceilings and soffits as indicated on these drawings are to be attached or suspended according to construction procedures described in latest edition of The Gypsum Construction Handbookby USG; published by Wiley. 11. All ceiling mounted items shall be installed per manufactures instructions. Contractor shall identify and provide all required blocking for their proper attachment. GENERAL NOTES - REFLECTED CEILING PLAN TRACK LIGHTING DETAIL #Description Date 1 For Permit 8/5/2021 1 10/06/21