Loading...
HomeMy WebLinkAboutA5.3 Architectural DetailsHSS 2x2x1/8 rails powdercoated to match steel columns. Railing length varies; refer to Architectural Plan HSS 2x2x1/8 posts powdercoated to match steel columns. Refer to plan for locations Mount to ground with steel base plate. Refer to typical mounting detail4" 4"8"1 1/2"5" 1 1/2" 1 1/2" 3" 3/8"x3"x8" steel base plate 6"6" 6" 6" 6" max.4"(2) 1/2" dia. stainless steel Hilti HAS rods using RE-500 epoxy with 4-1/2" embedment. HSS 2x2x1/8 posts powdercoated to match steel columns. Refer to plan for locations Section Plan Refer to typical gate detail where applicable. Grind all welds smooth Above hood1' - 6" Minimum20 gauge stainless steel panels from floor to 6" above bottom of hood. Kitchen exhaust hood with internal 3" standoff mounted to roof joist with 1/2" threaded rod; refer to hood drawings for more information. Kitchen equipment provided by owner. Final hookups by contractor. Base and flooring as specified; refer to finish plan Refer to architectural plan for wall type and constructionMin.6'-8"4'-0" Maximum3'-8"NSF rated ceiling tile (see rcp for specification). Utilize aluminum lay-in panels painted to match tile in 24" perimeter from hood Install gas main within wall as per plumbing plans 1x4 stained solid wood trim. Finish to match M.1 1x6 stained solid wood trim. Finish to match M-01. Metal panel wainscot to match M-02 over 1/2" stained veneer plywood over 1/2" plywood substrate. Refer to finish schedule Glass framing to be supported by framing built over booth back. Secure to wall and wood column. Build booth into column. Provide SKB Knee Brace Kit by Softforrms at 48" along wall V.I.F. V.I.F.Match existing45°Provide stainless steel panels typ. all sides of chute interior Provide stainless steel over 3/4" exterior grade plywood over 6" metal stud framed ramp at where existing slab occurs Extend stainless steel through floor opening and extend 12" in all directions© 2021 - All Rights Reserved. No portion(s) of this document may be reporoduced without written approval of Design CollectivePROJECT NO. INITIAL ISSUE DATE REVISIONS PROJECT STATUS 8/5/2021 4:07:12 PM A5.3 Architectural Details 1090.02 The Proscenium Building 31200 S. Rangeline Rd., Carmel INJune 4, 2021 For Permit OWNER TJKKitchens&Brewpubs 4022 North Hampton Dr. Powell, OH 43065 Tel: 614-406-3905 Email: thad@101beerkitchen.com ARCHITECT Design Collective Architecture 151 East Nationwide Blvd. Columbus, OH 43215 Tel: 614-464-2880 Email: mtoddy@dcollective.com STRUCTURAL ENGINEER Jezerinac Geers & Associates 5640 Frantz Rd. Dublin, OH 43017 Tel: 614-766-0066 Email: dschoeff@jgaeng.com MEP ENGINEER Prater Engineering 6130 Wilcox Rd. Dublin, OH 43016 Tel: 614-766-4896 Email: bcaines@praterengr.com GENERAL CONTRACTOR Capitol Construction Services, Inc. 11051 Village Square Lane Fishers, IN 46038 Tel: 317-574-5488 Email: kschott@capitolconstruct.com LANDLORD Novo Development Group 1215 S. Rangeline Rd. Carmel, IN 46032 Tel: 317-708-9400 Email: thill@novo.dev Contact: Thad Kittrell Contact: Matt Toddy Contact: Dave Schoeff Contact: Billy Caines Contact: Kevin Schott Contact: Tim Hill Scale: 1 1/2" = 1'-0"1Section -Railing Scale: 1 1/2" = 1'-0" 2Elevation -Railing Scale: 1" = 1'-0"4Section -Hood Wall Scale: 1" = 1'-0"3Section -Booth Knee Wall Scale: 3/4" = 1'-0"5Trash Chute Section #Description Date 10/06/21