HomeMy WebLinkAboutplan_design_release04292005_modifiedELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/3 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:August 4, 2021 Project number Release date 423607 08/04/21 Construction type Occupancy classification Scope of release V-A, SPK A-2, REM Type of release Project name Street address City County ARCH ELEC FA HOOD MECH PLUM Standard 101 Beer Kitchen 1200 S Rangeline Rd CARMEL HAMILTON To: Owner / Architect / Engineer Design Collective Matthew Toddy AR11900062 151 E. Nationwide Blvd. Columbus OH 43215 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: ACDS 4G0412AE 4G0603AF 4G0603AS 14B05012 14B29022 14B07037 14B0714 This project has been reviewed under the 2014 Indiana Building Code, 2014 Indiana Fire Code, 2009 Indiana Electrical Code, 2012 Indiana Plumbing Code, 2014 Indiana Mechanical Code, 2014 Indiana Fuel Gas Code, 2010 Indiana Accessibility Chapter 11 (ICC A117.1 2009), and the 2010 Indiana Energy Conservation Code (ASHRAE 90.1 2007) The proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. Detailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6- 3(a), 675 IAC 12-6- 7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) This release does not include structural work. Plans and specifications for adding or remodeling this system shall be filed as a new project or as a partial before commencing work in accordance with 675 IAC 12-6-3. Buildings shall be addressed in accordance with section 501.2 IBC (675 IAC 13-2.6) Where plumbing fixtures are required, separate facilities shall be provided for each sex in accordance with Section 2902.2, IBC (675 IAC 13-2.6). Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling. Such identification shall: 1. Be located in accessible concealed floor, floor-ceiling or attic spaces; 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the suggested wording, "FIRE WALL or FIRE BARRIER PROTECT ALL OPENINGS" or similar wording in accordance with Section 703.7, IBC (675 IAC 13-2.6). Penetrations in Rated Assemblies shall be effectively protected as set forth in section 714 IBC (675 IAC 13-2.6) Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 6144642880, mtoddy@dcollective.com ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/3 14B0718 14B0904425 14B07032 14B10043 14B31026 14W09062 14M050709 14M0507161 14FG041114 14B11061 14B1008110 14B0907 14W09077 9E21063 9E21008B1 9E11026A 9E60041 9E250104 AREL Fireblocking shall be installed in accordance with section 718 IBC (675 IAC 13-2.6) Counter heights shall be as set forth in Sections 904.4.2 and 904.5, ICC A117.1, 2009 (675 IAC 13- 2.6). Interior wall and ceiling decorative components shall be as in accordance with section 703.2 & section 806 IBC (675 IAC 13-2.6) and ASTM C 635 & C 636 Occupancy Load Signage shall be posted in accordance with Section 1004.3 IBC (675 IAC 13-2.6) Membrane structures shall comply with Section 3102.6, IBC (675 IAC 13-2.6). Fire Extinguisher travel distance shall be in accordance with Section 906.2 IFC (675 IAC 22-2.5) and NFPA 10. The complete installation of the kitchen exhaust hood and hood suppression system shall be in accordance with Sections 507 and 509, IMC (675 IAC 18-1.6). Type I kitchen hoods shall be tested prior to occupancy as set forth in Section 507.16, IMC (675 IAC 18-1.6). Gas fired appliances on wheels in Commercial Kitchens shall be installed as set forth in section 411.1.4 IFGC (675 IAC 25-3) (Quick Disconnects and Tethered) Where public or common use parking is provided, accessible parking spaces shall be provided in accordance with IC-5-16-9 and Section 1106.1 IBC (675 IAC 13-2.6) Doors serving a Group H occupancy, or an occupant load of 50 or more in a Group A or E occupancy, shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware in accordance with Section 1008.1.10, IBC (675 IAC 13-2.6). The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in accordance with Section 907, IBC (675 IAC 13-2.6). Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system shall be made. All functions of the system or alteration shall be tested in accordance with Section 907.7, IFC (675 IAC 22-2.5). A GFCI protected receptacle shall be located within twenty-five (25) feet of Heating/Cooling Equipment in accordance with Section 210.63 and 210.8 (b) IEC (675 IAC 17-1.8) All Commercial Kitchen receptacles shall be Ground-Fault Circuit Interrupter protected in accordance with Section 210.8 [B] IEC (675 IAC 17-1.8) Access and working space shall be provided and maintained about all electric equipment in accordance with Section 110.26, IEC (675 IAC 17-1.8). Neon lighting and signs shall be installed as set forth in Section 600.41, IEC (675 IAC 17-1.8). Electrical Bonding shall be in accordance with section 250.104 (A) (B) & (C) IEC (675 IAC 17-1.8) Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. This order is effective upon service. If you would like to request informal review of this order, please complete the informal review form located at https://www.in.gov/dhs/4149.htm. Following receipt of this form, the Department may modify or reverse the order, however, a request for an informal review does not extend the deadline for filing a petition for review with the Fire Prevention and Building Safety Commission (Commission). Additionally, if you have any questions regarding this order, you may contact that Department at (317) 232-2222. If you desire a formal administrative review of this order by the Commission, you must comply with the requirements of Indiana Code § 4-21.5-3-7 and file a written petition for review within 15 days of the date this order was served, however, this period is extended to 18 days if service is made by mail. Your petition for review must state facts demonstrating that you are: (1) a person to whom the order is specifically directed; (2) aggrieved or adversely affected by the order; or (3) entitled to review under any law. You may submit your petition by the following methods: U.S. MAIL OR PERSONAL SERVICE ONLINE Fire Prevention and Building Safety Commission By completing the form at c/o Legal Counsel https://www.in.gov/dhs/4148.htm ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 3/3 302 W. Washington Street, Rm. E208 Indianapolis, IN 46204 For additional information about the administrative review process and applicable templates that may be used for filings, visit the following link https://www.in.gov/dhs/appeals.htm. Code review official Address (name,title of local official,street,city,state and ZIP code REX MAYS JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Indiana State Building Commissioner rmays@dhs.in.gov