Loading...
HomeMy WebLinkAboutA0.1 - Accessibility GuidelinesFigure 304.3 -Size of turning space (A) Circular (B) T-Shaped 60"24" min36" min min 12" 36" min min 12" 6 0" M IN Figure 404.2.2 Clear width of doorways a) hinged door b) sliding door d) doorways without doors90°> 24"32" min 32" min 36" min b) Front approach, push side If both closer and latch are provided 48" minmin 12" 18" min60" min60" min36" min 54" min42" min 48" min42" minmin 12" 22" min 54" min48" min24" min 48" min42" min24" min a) front approach, pull side c) hinge approach, pull side d) hinge approach, pull side e) hinge approach, push side f) latch approach, pull side g) latch approach, push side Figure 404.2.3.2 If both closer and latch are provided If both closer and latch are provided If closer is provided If closer is provided (a) Single space (b) Multiple adjacent spaces (a) Front or rear access 48"min60" min(b) Side access Figure 802.4 Depth of wheelchair space in assembly areas Figure 802.3 Width of wheelchair space in assembly areas 36" min 33 min 33" min Figure 305.3 Size of clear floor space (a) Forward Figure 305.5 Position of Clear floor space (b) Parallel 30" min48" min 48" min30" min 30" min48" min Figure 303.2 Vertical Changes in Level Figure 303.3 Beveled Changes in Level 2 1 Figure 302.2 Carpet Pile Height 1/4" max1/2" max 1/4" 1/4" 1/2" max Figure 302.3 Elongated Openings in Floor or Ground Surfaces long dimension perpendicular to dominant direction of travel dominant direction of travel 1/2" max Figure 307.2 -Limits of protruding objects X > or = 80"4" max X>27Figure 307.3 Post-mounted protruding objects (a) 4" max 4" max >27" -< 80"X> or =12X > or = 12" 27" max(b) 4" max 4" max >27"-<80"Figure 308.2.1 Unobstructed forward reach Figure 308.2.2 Unobstructed high forward reach Figure 308.3.1 Unobstructed side reach (a) (b) Figure 308.3.2 Unobstructed high side reach (a) (b)48" maxmin15"48" max20" max 44" maxmax >20"-25"48" maxmin15"max 10"34" max48" maxmax 10" max >10"-24"46" max34" maxFigure 404.2.3.5 Maneuvering clearance at recessed doors (a) Pull side (b) Push side (c) Push side, door provided with both closer and latch48" min 18" min 60" min48" min min 12" Figure 404.2.3.4 Maneuvering clearances at doorways without doors b) side approacha) front approach 48" min42" minFigure 404.2.3.3 Maneuvering clearances at sliding and folding doors a) front approach b) pocket or hinge approach c) stop or latch approach 48" min42" minmin 1' - 10"42" min2' - 0" min X>8" X>8" X>8" 60" min60" min 60" min Figure 404.2.5 Two doors in series (a) (b) (c)60" minDoor width 48" min Door widthDoor width 48" minFigure 505.4 Handrail height a) stairs b) ramp Figure 505.5 Handrail clearance Figure 505.10.1 Top and bottom handrail extensions at ramps Figure 505.10.2 Top handrail extensions at stairs Note= x= tread depth Figure 505.10.3 Bottom handrail extensions at stairs Bottom stair Top ramp Top stair34" to 38"34"-38"1 1/2" min 12" min 12" min 4" max34"-38"H < 271' - 0" X X 24" max 48" min 24" max32" min 36" min Figure 403.5 Clear width of an accessible route Figure 403.4.1 Clear width at 180 degree turn (a) 180 degree turn (b) 180 degree turn (Exception)48" min42" min 42" min X < 48" 60" min36" min 36"min X < 48" 32" min 36" min Figure 306.2 Toe clearance (a) Elevation (b) Plan Figure 306.3 Knee Clearance 30" min30" min9"6" max 17"-25" (a) Elevation (b) Plan 25" max 8" min min9"11" min 2' - 3" min 16"-18" a) accessible water closets b) ambulatory accessible water closets Figure 604.2 Water closet location Figure 604.3 Size of clearance for water closet other fixtures not allowed within this area Figure 604.5.1 side wall grab bar for water closet Figure 604.5.2 Rear wall grab bar for water closet (a,b) Protruding dispenser below and above grab bar Figure 604.7 Dispenser outlet location c) Recessed dispenser Fixture 35"-37" 17"-19" Fixture 60" min 56" min16"-18" Fixture 33"-36"17"-19"42 min 54" min max 12"min18"39"-41" 37 3/8"33"-36"36" min min 24" min 12"min18"42" max 23 15/16" min min 18"36" max 24" min 48" max42" max48 3/8" max36" max turning radi us60" mi n7' - 0"7' - 6" +/- 56"14"-16" 16"-18" 60" min (a) Minimum clear dimensional requirements-inward door swing Wall hung lavatory Floor mounted tank-type water closet 30" x 48" min clear space Note: 30"x 48" of clear floor space is required in every restroom. When 30" x 48" clear floor space is provided beyond the arc of the door swing, the door is permitted to swing into the clear floor space or clearance required for any fixture. Door may swing into a required wheelchair turning space. Per section 603.2.2, exception #2 allows a single occupancy toilet room door to swing into the required clear fixture floor or ground space when another clear floor or ground space is provided outside the radius of the door swing.turnin g radius60" mi n6' - 3"7' - 2"59" Min. (Floor)56" Min. (Wall)+/- 52"14"-16" 16"-18" 60" min Wall hung lavatory Floor mounted water closet 30" min x 48" min clear space (b) Minimum clear dimensional requirements-outward door swing Note: Door hardware and controls for accessible plumbing fixtures must be operable with one hand and must not require tight grasping, pinching, or twisting of the wrists. Hot water and drainpipes under accessible lavatories must be insulated or otherwise configured to protect against contact. There must be no sharp or abrasive surfaces beneath them.59" Min. (Floor)56" Min. (Wall)Figure 606.3 Height of Lavatories, Sinks and Accessories Pipe protection 40" max34" max40" max48" maxKnee & Toe Clearance to reflective surface Note - For braille character mounting height see section 703.4.5 Figure 703.3.10 Height of raised characters above floor Figure 703.3.11 Location of Tactile signs at doors Area of Refuge Area of Refuge 60" max 48" minSign Braille characters 45°18"min 18"Sign containing raised characters Clear floor area Varies see Figure 703.3.11 Varies - coordinate in field Provide (1) sign per toilet room and (1) sign per exit passageway/ discharge complying with the referenced standard or the local authority having jurisdiction. Black plastic (field) background w/ white raised uppercase letters, braille and emblems. Refer to Life Safety Plan for keynoted locations. Note -pictograms and lettering must be raised 1/32" min. Sign to have raised and braille characters and pictogram symbols of accessibility. Mount 5'0" to centerline A.F.F. Refer to sections 703.2 through 703.6 for additional information. 6" min of door frame 9" min edge 60" A.F.FMount center6" min1 1/2" high white lettering on black background 3/8" min 3/8" min6" min 6" minof door frame 9" min edge 60" A.F.FMount center6" min 6" min8" MinMAXIMUM OCCUPANCY XXX G.C. to post the following 8" x 14" metal signs in any space greater than 50 occupants and where indicated on Life Safety Plan. Figure 605.2 Height and Depth of Urinals (a) wall hung type (b) stall type 13 1/2" min. 13 1/2" min. 17" max.1'-10"2'-11"2'-5"3'-8"2'-9"2'-5"1'-11" Confirm mounting heights and dimensions per indicated specification and Manufactuers installation instructions.© 2021 -All Rights Reserved. No portion(s) of this document may be reporoduced without written approval of Design CollectiveArchitect, License # Expiration Date: December 31, 2021 PROJECT NO. INITIAL ISSUE DATE REVISIONS PROJECT STATUS 8/5/2021 3:57:23 PM A0.1 Accessibility Guidelines 1090.02 The Proscenium Building 31200 S. Rangeline Rd., Carmel INJune 4, 2021 AR11900062 For Permit OWNER TJKKitchens&Brewpubs 4022 North Hampton Dr. Powell, OH 43065 Tel: 614-406-3905 Email: thad@101beerkitchen.com ARCHITECT Design Collective Architecture 151 East Nationwide Blvd. Columbus, OH 43215 Tel: 614-464-2880 Email: mtoddy@dcollective.com STRUCTURAL ENGINEER Jezerinac Geers & Associates 5640 Frantz Rd. Dublin, OH 43017 Tel: 614-766-0066 Email: dschoeff@jgaeng.com MEP ENGINEER Prater Engineering 6130 Wilcox Rd. Dublin, OH 43016 Tel: 614-766-4896 Email: bcaines@praterengr.com GENERAL CONTRACTOR Capitol Construction Services, Inc. 11051 Village Square Lane Fishers, IN 46038 Tel: 317-574-5488 Email: kschott@capitolconstruct.com LANDLORD Novo Development Group 1215 S. Rangeline Rd. Carmel, IN 46032 Tel: 317-708-9400 Email: thill@novo.dev Contact: Thad Kittrell Contact: Matt Toddy Contact: Dave Schoeff Contact: Billy Caines Contact: Kevin Schott Contact: Tim Hill TURNING SPACE ASSEMBLY AREAS REACH RANGES PROTRUDING OBJECTS CHANGES IN LEVEL CLEAR FLOOR SPACE DOORS AND DOORWAYS - CLEAR WIDTH ACCESSIBLE DOORS IN A SERIES DOORS AND DOORWAYS - MANEUVERING CLEARANCE DOORS AND DOORWAYS - MANEUVERING CLEARANCE HANDRAILS WATER CLOSETS AND TOILET COMPARTMENTS WALKING SURFACES KNEE & TOE CLEARANCES LAVATORIES & SINKS ACCESSIBLE TOILET ROOMS URINALS AND CHANGING STATIONS SIGNS SIGNS - RAISED CHARACTERS 1. All indicated dimensions are clear/ finish values. 2. Referenced standard as indicated on title sheet. 3. The "General Accessibility Notes" and "Figures" on this sheet are provided as a general reference to illustrate common conditions addressed within the referenced standard. Some figures have been modified from those published in the standard to provide greater clarity. General contractor should reference the complete publication for any clarifications or questions. 4. Protruding objects Protruding objects on circulation paths shall comply with section 307. 5. Operable Parts Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply sections 309 and 404.2.6. 6. Accessible routes Accessible routes shall comply with section 304 and chapter 4. 7. Parking spaces Where parking spaces are provided, parking spaces shall be provided in accordance with sections 406 and 502. 8. Passenger loading zones and bus stops Where provided, passenger loading zones shall comply with sections 503 and 805. 9. Stairways Where provided, interior and exterior stairs that are part of a means of egress shall comply with sections 504 and 505. 10. Drinking fountains Where drinking fountains are provided at an exterior site, on a floor, or within a secure area, they shall be provided in accordance with sections 305, 306, and 602. 11. Kitchens, kitchenettes, and sinks Where provided, kitchens, kitchenettes, and sinks shall comply with sections 308, 606, and 804. 12. Toilet facilities and plumbing elements Where toilet facilities are provided, they shall comply with section 305 and chapter 6. 13. Signs Signs shall be provided in accordance with section 703 14. Assembly areas Assembly areas shall provide wheelchair spaces, companion seats, and designated aisle seats complying with sections 802 and 902. 15. Dressing, fitting, and locker rooms Where dressing, fitting, and locker rooms are provided, at least 5 %, but no fewer than one of each type of use is each cluster provided shall comply with sections 803 and 903. 16. Storage Where storage is provided in accessible spaces, at least one of each type shall comply with sections 305 and 905 17. Dining surfaces and work surfaces Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with sections 305 and 902. In addition, where work surfaces are provided for use by other than employees, at least 5 % shall comply with sections 305 and 902. 18. Sales and service Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with sections 305, 403, and 904. GENERAL NOTES - ACCESSIBILITY #Description Date 10/06/21