HomeMy WebLinkAboutA000.7MIN. 12 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"
\A1;1'-0"\PTYP.
\A1;5'-4"
\A1;1'-0"
\A1;5'-3{\H0.75x;\S3#4;}"
\A1;4'-0"
\A1;5'-0"
\A1;5'-0"
POT VENTS
\A1;10'-0"
GUTTER AND DOWNSPOUTS
12:12
10:12
10:12
12:12
12:12
12:12
10:12
10:12
12:12
8:12
12:1212:12
"A"
2551
ROOF AREA:
SQ. FT.
12:12
12:12
"C"
198
ROOF AREA:
SQ. FT.ELEVATION EC2MATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2486AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.314.143.3943.6580AT EAVE4.974.144.3856.35063.00TOTAL (MIN)8.298.297.76100.003 HIGH -RIDGE VENT3.314.144.1948.954020.00AT EAVE4.974.144.3851.05063.00TOTAL (MIN)8.298.298.57100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEROOF AREA "C"SQ FTG198AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.260.330.4243.2610AT EAVE0.400.330.5656.7408.00TOTAL (MIN)0.660.660.98100.003 HIGH -RIDGE VENT0.260.330.5047.37004.00AT EAVE0.400.330.5652.6308.00TOTAL (MIN)0.660.661.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE"B"572ROOF AREA:SQ. FT.4:124:124:12ROOF AREA "B"SQ FTG572AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.760.950.8543.2620AT EAVE1.140.951.1156.74016.00TOTAL (MIN)1.911.911.96100.003 HIGH -RIDGE VENT0.760.950.00#####000.00AT EAVE1.140.950.00#####00.00TOTAL (MIN)1.911.910.00######ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEA4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE
Single Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Rockwall
2054.300Home for * Market Home *, 7231-02600Street Address, Carmel, State 00000ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
10/06/21