Loading...
HomeMy WebLinkAboutSun Warrior Solar - Casey Hammond - CAD_zpMOmjdwaDuke Energy SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 LABELS PV07 PLACARD PV08 SITE PHOTOS COVER PAGE - PV01 DRAWN BY: SoloCAD 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS AERIAL VIEW: SHEET INDEX: EQUIPMENT: AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) ENPHASE IQ7-PLUS-2-US RACKING: IronRidge ENERGY STORAGE: Encharge 10 OCCUPANCY: R-3 ZONING: RESIDENTIAL 2017 NEC 2018 IRC 2012 IFC 2012 IBC STREET VIEW: GENERAL NOTES APPLICABLE GOVERNING CODES SITE SPECIFICATIONS AC MSP M BATT C JB AC C Duke Energy SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINEFRONT OF HOME105 John StBATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER SUB SUB PANEL SITE PLAN - PV02 DRAWN BY: SoloCAD MP1 PITCH: 17° AZIMUTH: 90° 206'-7" 206'-7" 99'-9" ROOF INFO: ROOF TYPE standing_steam_metal ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x6 RAFTER/TOP CHORD SPACING 16" ATTACHMENT SPACING 48 AC MSP M BATT C JB AC C EQUIPMENT INFORMATION: RAIL MANUFACTURER IronRidge RAIL PART NUMBER XR-100 ATTACHMENTS S-5! - VERSA BRACKET ATTACHMENT QTY 50 SPLICE QTY 6 MIDCLAMP QTY 50 ENDCLAMP QTY 12 ROOF INFO: Duke Energy SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:28 ARRAY AREA:MODULE COUNT * 18.06ft² = 505.68 ROOF AREA:1482 ft² PERCENT OF ROOF COVERED:34% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1400 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 28 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²ROOF ATTACHMENTS - PV03 DRAWN BY: SoloCAD 3' TYP 3' TYP PV MODULE FRAME RAIL END CLAMP DETAILS END CLAMP 1" PV MODULE FRAME RAIL MID CLAMP DETAILS MID CLAMP 21 RAIL ATTACHMENT ASSEMBLY 2'-8" MIN - 3'-10" MAX 3 RAIL PV MODULE ATTACHMENT SPACING1'-8" MAX. 21 FRONT VIEW 2'-8" MIN - 3'-10" MAX SIDE VIEW (E) RAFTER/TOP CHORDS (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING 3 (E) METAL STANDING SEAM ROOF PV MODULE RAIL ATTACHMENT ATTACHMENT EQUIPMENT INFORMATION: RAIL MANUFACTURER IronRidge RAIL PART NUMBER XR-100 ATTACHMENTS S-5! - VERSA BRACKET ATTACHMENT QTY 50 SPLICE QTY 6 MIDCLAMP QTY 50 ENDCLAMP QTY 12 ROOF INFO: ROOF INFO: ROOF TYPE standing_steam_metal ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x6 RAFTER/TOP CHORD SPACING 16" ATTACHMENT SPACING 48 Duke Energy SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:28 ARRAY AREA:MODULE COUNT * 18.06ft² = 505.68 ROOF AREA:1482 ft² PERCENT OF ROOF COVERED:34% ARRAY WEIGHT:MODULE COUNT * 50lbs = 1400 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 28 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²MOUNTING DETAIL - PV04 DRAWN BY: SoloCAD DYNAMIC DIAGRAM INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 5. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH J-BOXJ-BOX J-BOX N G AC DC AC DC AC DC AC DC AC DC AC DC 1 2 3 1 2 ENPHASE (X-IQ-AM1-240-3) AC COMBINER BOX SOLAR LOADS ONLY UL 1741 COMPLIANT (2) 20A-2P10 MODULES 9 MODULES STRING (1): 12.1 A AC STRING (2): 10.9 A AC (E) 120/240 VAC TO UTILITY GRID (E)UTILITY METER N G SUPPLY SIDE CONNECTION: NEC 230.46, NEC 230.79, NEC 705.12(A) (E)GROUNDING ELECTRODE (N) 225A MAIN SERVICE PANEL 4 (N) 50A-2P (E) LOADS (N) 20A FUSES PV AC DISCONNECT FUSED, AIC 10kA VISIBLE, LOCKABLE, LABELED, OPEN 60A, 240V, 2-POLE (N) 200A-2P MAINPV AC DISCONNECT VISIBLE, LOCKABLE, LABELED, OPEN 30A, 240V, 2-POLE N G ENPHASE ENPOWER SMART SWITCH (MID) TRANSFER SWITCH (N) 30A-2P (N) 20A-2P 10AWG (L1,L2) 10AWG GROUND (N) 100A-2P ENPHASE ENCHARGE 10 10.08kWh 3.84kWac CAPICITY N G (E) LOADS (E) LOADS (N) 100A CRITICAL LOADS PANEL LUG REDUCING KIT TO BE INSTALLED 5 J-BOX N G AC DC AC DC AC DC 1 3 ENPHASE (X-IQ-AM1-240-3) AC COMBINER BOX SOLAR LOADS ONLY UL 1741 COMPLIANT (1) 20A-2P9 MODULES STRING (1): 10.9 A AC 2 J-BOX 4 4 4 6 DATE: September 29, 2021 SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) Duke Energy SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.LINE DIAGRAM - PV05 DRAWN BY: SoloCAD VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER Conduit & Conductor Schedule TAG WIRE GAUGE DESCRIPTION QTY CONDUIT SIZE CONDUCTOR RATING # OF CONDUCTORS DERATE TEMP. DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 12-2 TC-ER, THWN-2, COPPER (L 1, L 2)(2)N/A - FREE AIR 30A N/A - FREE AIR 0.96 28.8A N/A - FREE AIR 6 AWG BARE, COPPER (GROUND)(1) 2 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (L 1, L 2)(2)3/4" EMT 40A 1 0.96 38.4A 11.9%10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND)(1) 3 10 AWG THHN/THWN-2, COPPER - (L1, L2)(4)3/4" EMT 40A 0.8 0.96 30.72A 27.8% 10 AWG THHN/THWN-2 - (GROUND)(1) 4 6 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 32.6%10 AWG THWN-2 COPPER - (GROUND)(1) EQUIPMENT SCHEDULE: TYPE:QTY:DESCRIPTION:RATING: MODULES:(28)Trina Solar TSM-DD06M.05 - 335 335 W INVERTERS:(28)ENPHASE IQ7PLUS-72-2-US 240 W AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 60A AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 30A ENERGY STORAGE:(1)Enphase Encharge 10 9.6 kWh 5 6 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3)3/4" EMT 65A 1 0.96 62.4A 32.58% 10 AWG THWN-2 COPPER - (GROUND)(1) 4 2 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3)1.25" EMT 115A 1 0.96 110.4A 26.53%6 AWG THWN-2 COPPER - (GROUND)(1) 6 2 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3)1.25" EMT 115A 1 0.96 110.4A 26.53%6 AWG THWN-2 COPPER - (GROUND)(1) Duke Energy SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: LABEL 1 AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING SERVICE [NEC. 690.35(F)] INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED AT SIDE OF HOUSE JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 3 4 4 5 5 12 88 8 8 1 11 LABELING NOTES: 1.LABELING REQUIREMENTS BASED ON THE 2011 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 2.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 3.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 4.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] DIRECTORY PLAQUE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] 4 1 10 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 10 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 9 9999 6 1322 2 2 LABEL 11 SIGN LOCATED AT UTILITY SERVICE EQUIPMENT [NEC 690.56(C)] PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN WARNING LABEL 10 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(D)(2)(3)(b)]PV INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE PHOTOVOLTAIC RAPID SHUTDOWN DC DISCONNECT LABEL 12 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT CONTROLLER [NEC 690.13(B)] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL 2 AT BUILDING OR STRUCTURE MAIN DISCONNECTING MEANS. [NEC 690.17(E), NEC 705.22] LABEL 3 AT EACH DC DISCONNECTING MEANS [NEC 690.53] NOMINAL AC OPERATING VOLTAGE = LABEL 4 AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.54] DUEL POWER SOURCES. SECOND SOURCE IS PV SYSTEM WARNING LABEL 5 AT POINT OF INTERCONNECTION. [NEC 705.12(D)(3)] MAX. AC OPERATING CURRENT = PHOTOVOLTAIC DC DISCONNECT LABEL 6 AT EACH DC DISCONNECTING MEANS [NEC 690.13(B)] LABEL 8 AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] PHOTOVOLTAIC AC DISCONNECT LABEL 9 AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS [NEC 690.31(G)(3)] WARNING: PHOTOVOLTAIC POWER SOURCE 0 0 0 0 34 240 LABEL 13 SIGN LOCATED AT LOAD CENTER IF CONTAINS 3 OR MORE POWER SOURCES [NEC 705.12(D)(2)(3)(C)] WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. WARNING MAX. POWER POINT CURRENT (IMP) = MAX. POWER POINT VOLTAGE (VMP) = MAX. SYSTEM VOLTAGE (VOC) = SHORT-CIRCUIT CURRENT (ISC) = PHOTOVOLTAIC AC DISCONNECT LABELS - PV06 DRAWN BY: SoloCAD AC MSP M BATT C JB AC C Duke Energy SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) PV ARRAY MAIN DISTRIBUTION UTILITY DISCONNECT FRONT OF HOMERAPID SHUTDOWN AC DISCONNECT SWITCH 105 John St , Carmel IN 46032 BATTERY(IES) PLACARD - PV07 DRAWN BY: SoloCAD Duke Energy SITE INFORMATION Casey Hammond 105 John St Carmel , IN 46032 AC SYSTEM SIZE: 6 kW AC DC SYSTEM SIZE: 9.38 kW DC Lat, 39.9993896 Long, -86.1323022999999 (28) Trina Solar TSM-DD06M.05 - 335 PV MODULES (28) Enphase IQ7PLUS-72-2-US INVERTER(S) DATE: September 29, 2021 SUN WARRIOR SOLAR 3601 HOBSON RD STE 205 FT.WAYNE 46815 LICENSE # 18338 CONTRACTOR INFORMATION: SITE PHOTOS: SITE PHOTOS - PV08 DRAWN BY: SoloCAD The S-5-U clamp is our most popular and versatile in North America.S-5-U and S-5-U MiniS-5-U Clamp S-5-U Mini Clamp Please note: All measurements are rounded to the second decimal place. S-5-U Mini Clamp S-5-U Clamp 1.50" 0.90" 1.50" 1.50" 0.90" 1.50" on part