Loading...
HomeMy WebLinkAboutC11.1 SITE DETAILSStandard Unit - Near Vertical Setback Reinforced Soil Retained Soil Typical Reinforced Wall Section Foundation Soil Design Height8" Min. Low Permeable Soil 24" Keystone Cap Unit Keystone Standard Unit Unit Drainage Fill (3/4" Crushed Rock or Stone) Finished Grade Unreinforced Concrete or Crushed Stone Leveling Pad Approximate Limits of Excavation 4" Perforated PVC Drainage Tile 1/8" - 1/4" 8" Note: When site conditions require, wrap drainage tile in 3/4" aggregate and filter fabric with drainage composite or aggregate back drain system, as directed by geotechnical engineer. Grid Depth Typical Gravity Wall Section Standard Unit - 1" Setback Foundation Soil Finished Grade Unreinforced Concrete or Crushed Stone Leveling Pad MAX 36"Retained Soil Unit Drainage Fill (3/4" Crushed Rock or Stone) 24" Keystone Standard Unit Keystone Cap Unit8" Min. Low Permeable Soil 4" Perforated PVC Drainage Tile Wrapped in Filter Fabric (If Required) Approximate Limits of Excavation 1" - 1 1/4" 8" Section Leveling Pad Detail Elevation 6" Crushed Rock or Unreinforced Concrete Leveling Pad 8" or 16" Step Note: 1. The leveling pad is to be constructed of crushed stone or 2000 psi ± unreinforced concrete. Top of Wall Steps (2) - 4" Cap Units or (1) - 8" Cap Unit Note: 1. Secure all cap units with Keystone Kapseal or equal. 8" Keystone Unit 4" Cap Unit W6" W + 12" 1/2" x 5 1/4" Fiberglass Pins Front Face Standard Unit Standard Elevation Standard Plan Cap Unit Elevation Cap Unit Plan18" ±18''8''4''18''10 1/2" ±18''10 1/2" ±4''Cap Unit Elevation Cap Unit Plan Geogrid is to be Placed on Level Backfill and Extended Over the Fiberglass Pins. Place Next Unit. Pull Grid Taught and Backfill. Stake as required. Grid & Pin Connection Universal Cap Unit Option Straight Split Cap Unit Option Dimensions & Availability Will Vary by Region Dimensions & Availability Will Vary by Region Dimensions May Vary by RegionStrength DirectionPLOT SCALE: 1:1 EDIT DATE: 8/30/21 - 5:01 PM EDITED BY: MJACKSON DRAWING FILE: Z:\PROJECTS\2020\0113 - ISLAMIC LIFE CENTER\2. DESIGN\CAD\C11 SITE DETAILS.DWGPRINT DATE: 8/31/21C11.1 SITE DETAILSISLAMIC LIFE CENTER14120 Shelborne Road, Carmel IN 46074Al Salam FoundationDRAWN BY:CHECKED BY:TMJ 6280 N. Shadeland Avenue, Suite AIndianapolis, IN 46220Phone: (317) 598-6647 | www.theveridusgroup.comPROJECT NO.: 2020.0113 MWJ Standard Unit 18 - Straight Face Details Typical Wall Details Keystone Retaining Wall Systems 4444 W 78th Street 952-897-1040 Minneapolis, MN 55435 Design is for internal stability of the KEYSTONE wall structure only. External stability, including but not limited to foundation and slope stability is the responsibility of the Owner. The design is based on the assumption that the materials within the retained mass, methods of construction, and quality of materials conform to KEYSTONE's specification for this project. This drawing is being furnished for this specific project only. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of Keystone Retaining Wall Systems, Inc. Copyright 2003 Keystone Retaining Wall Systems