Loading...
HomeMy WebLinkAboutC17 UTILITY PROFILESPROPOSED DRAINAGE STR. 10-15 900 905 910 915 920 925 900 905 910 915 920 925 910.97914.101+00911.07913.68910.79914.432+00910.56914.24910.78914.773+00911.53914.73912.28915.254+00912.83915.54913.12914.165+00912.91914.8315 T.R. 914.13R-347214 T.R. 914.06R-347213 T.R. 914.50R-3286-8V118 LF OF 21" RCP @ 0.25% SLOPE 12 T.R. 914.19R-3286-8V113 LF OF 21" RCP @ 0.35% SLOPE 11 T.R. 913.57R-3286-8V27"(W)907.940+05.0012"(W)910.456"(S)910.405+41.5889 LF OF 12" RCP @ 0.64% SLOPE 12"(E)909.8818"(SW)909.796"(SE)909.606"(E)909.804+52.80129 LF OF 18" RCP @ 0.46% SLOPE 18"(NE)909.2021"(S)909.106"(SE)909.206"(NE)909.2012"(NW)909.203+23.3821"(N)908.8021"(S)908.7012"(E)908.802+05.14113 LF OF 21" RCP @ 0.35% SLOPE 21"(N)908.3012"(S)908.9627"(E)908.2012"(NW)908.308"(SE)907.800+92.1310 T.R. 910.96STR.PROPOSED GROUND EXISTING GROUND 87 LF OF 27" RCP @ 0.30% SLOPE PROFILE VIEW: 30:5 PVC SDR 35 TOP: 906.31 PROPOSED BUILDING FFE: 916.60' FPG:916.10' LAG: 915.10'UTILITY EASEMENTUTILITY EASEMENTUTILITY EASEMENTUTILITY EASEMENTAA EXISTING FIRE HYDRANT CA CB DA DB POND 10 YEAR ELEV: 911.33' POND 2 YEAR ELEV: 910.45' 915 9 1 5 915915915915 915 915915916916915910 915 915 911 912 913 914 910910908908909909 911914914915915915914914915915 9 1 5 913 914914TB 913.10 TB 913.55  914.60  912.82  914.20  913.10  914.26 TW 914.71 BW 911.54 TW 915.45 BW 911.60 BW 910.52 89 LF OF 12" RCP @ 0.64%129 LF OF 18" RCP@ 0.46%118 LF OF 21" RCP @ 0.25%113 LF OF 21" RCP@ 0.35%63 LF OF 12" RCP @ 1.40% 71 LF OF 12" RCP @ 0.95%223 LF OF 8" SDR 35 PVC@ 0.73%87 LF OF 27" R C P @ 0.30%56 LF OF 8" SDR 35 PVC@ 1.00%47 LF OF 6" SDR 3 5 P V C @ 1.00% 3 LF OF 6" SDR 35 PVC @ 1.00% 9 LF OF 6" SDR 35 PVC @ 1.00%80 LF OF 6" SDR 35 PVC@ 2 .82% 41 LF OF 6" SDR 35 PVC @ 4.33% 44 LF OF 6" SDR 35 PVC @ 3.96% 9 0 L F O F 6 " SDR 3 5 PVC@ 2 . 0 0% 77 LF OF 18" RCP @ 0.33% 65 LF OF 6" SDR 35 PVC @ 2.10% 17 LF OF 6" SDR 35 PVC @ 1.71% 25 LF OF 6" SDR 35 PVC @ 1.71% 60 LF OF 6" SDR 35 PVC @ 0.83% 18 LF OF 6" SDR 35 PVC @ 1.13% STR. 13 Type C MH / R-3286-8V TR: 914.50 INV(NE): 909.20 INV(S): 909.10 INV(SE): 909.20 INV(NE): 909.20 INV(NW): 909.20 STR. 12.2 Type C MH / R-3472 TR: 914.14 INV(W): 910.45 INV(NW): 911.00 INV(N): 911.64 INV(NW): 910.65 STR. 12.1 Type C MH / R-3472 TR: 914.01 INV(E): 909.57 INV(W): 909.47 INV(E): 909.57 INV(W): 910.45 INV(S): 910.40 STR. 12 Type C MH / R-3286-8V TR: 914.19 INV(N): 908.80 INV(S): 908.70 INV(E): 908.80 STR. 11 Type C MH / R-3286-8V TR: 913.57 INV(N): 908.30 INV(S): 908.96 INV(E): 908.20 INV(NW): 908.30 INV(SE): 907.80 STR. 11.1 24'' ADS2824 Basin / ADS 2499CGS TR: 913.51 INV(SE): 910.00 STR. MH-ILC2 48 SANITARY MANHOLE TR: 914.44 INV(N): 906.64 INV(S): 906.53 STR. 10 27" CES INV(W): 907.94 STR. 11.2 AQUA-SWIRL/AS-8 STR. RD06 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.96 STR. RD05 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.96 PIV WATER TEE WATER TEE 45 Degree Bend Fire Department Connnection FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY Refer to MEP Plan for Connection to Building INV: 910.96 Refer to MEP Plan for Connection to Building INV: 910.96 Refer to MEP Plan for Connection to Building INV: 910.96 STR. RD2.3 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.96STR. RD02.2 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.96 STR. RD01 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.96STR. RD03 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:912.96 STR. RD04.2 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:912.96 STR. RD04.3 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:912.96 STR. 3.4 SAN C/O. TYPE 3. Refer to MEP Plan for Connection to Building INV(SW): 911.60 STR. CES 2 18" CES TR: 917.86 INV(N): 912.82 STR. RD10 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:909.50 STR. RD09 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.3 STR. RD07 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.60 STR. SP01 Cleanout. Refer to MEP Plan for Connection to Building and Backflow Preventer INV(S): 913.00 STR. OCS 1.0 TEE Water 45 Bend Water 45 Bend Water STR. MH-ILC3 48 SANITARY DROP MANHOLE TR: 915.90 INV(N): 911.29 INV(S): 907.20 INV(NE): 910.53 STR. 3.2 SAN C/O. TYPE 3 TR: 911.64 INV(E): 911.09 INV(W): 911.09 STR. 31 Type C MH / R-2560-EA-E10 TR: 913.25 INV(W): 909.39 STR. 30 12" CES INV(E): 909.06 STR. 13.1 24'' ADS2824 Basin / ADS 2499CGS TR: 913.91 INV(SE): 910.41 17 LF OF 12" RCP @ 6.95% S4 XB XC D3 D3 D3 D3 D3 D3 D3 W3 W3 W3 W2 W1 XD XE D5 W4 G1 G2 W5 D1 D1 D1 S1 W6 S2 S2 S2 S2 S2 S3 ISLAMIC LIFE CENTER14120 Shelborne Road, Carmel IN 46074Al Salam FoundationBENCHMARK DATA DRAWN BY:CHECKED BY:TMJ 6280 N. Shadeland Avenue, Suite AIndianapolis, IN 46220Phone: (317) 598-6647 | www.theveridusgroup.comPROJECT NO.: 2020.0113 LEE 4 RESET ELEVATION 910.53 (NAVD 88) A DNR TABLET FOUND IN TOP OF THE CONCRETE POST 15.3 FEET EAST OF THE CENTERLINE OF SHELBORNE ROAD AND 1500 FEET SOUTH OF THE ORIGINAL CENTERLINE OF 146TH STREET. CSC TBM #156 ELEVATION 912.83 A 5/8" CAPPED REBAR SET ±12 FEET EAST OF THE CENTERLINE OF SHELBORNE ROAD, ALSO ±760 FEET NORTH OF THE CENTERLINE OF 141ST STREET. CSC TBM #151 ELEVATION 912.59 A MAGNAIL WITH WASHER STAMPED "TSC CPT" FOUND AT THE END OF AN ASPHALT PATH, ALSO ±335 FEET WEST OF THE CENTERLINE OF SHELBORNE ROAD, ALSO ±25 FEET NORTH OF THE CENTERLINE OF 141ST STREET. MWJPLOT SCALE: 1:1 EDIT DATE: 8/11/21 - 10:02 AM EDITED BY: MJACKSON DRAWING FILE: Z:\PROJECTS\2020\0113 - ISLAMIC LIFE CENTER\2. DESIGN\CAD\C15 UTILITY PLAN SOUTH.DWGPRINT DATE: 8/11/21GENERAL NOTES PER INDIANA STATE LAW IS-69-1991. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. UTILITY LEGEND KEYNOTES WATER LINE TELEPHONE LINE ELECTRIC LINE GAS LINE VALVE WATER METER PIT SANITARY SEWER LINE HYDRANT STORM SEWER LINE ROOF DRAIN CLEANOUT (STORM & SANITARY) BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY CENTRAL STATES CONSULTING,LLC. PROJECT NUMBER 20-043, DATED 06/07/2020. C17 UTILITY PROFILES 1.IT SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THE PHASE OF WORK. IT SHALL ALSO BE THE SUBCONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION OF EACH UTILITY BEFORE WORK IS STARTED. EACH SUBCONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN FIELD BEFORE WORK IS STARTED OR RESUMED. 2.ALL MATERIALS AND CONSTRUCTION FOR SANITARY SEWERS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 3.ALL MATERIALS AND CONSTRUCTION FOR STORM SEWERS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 4.ALL MATERIALS AND CONSTRUCTION FOR WATER MAINS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 5.ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVED AREAS TO BE BACKFILLED WITH COMPACTED GRANULAR MATERIAL. 6.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 7.ANY WATER MAINS TO HAVE 54" MINIMUM COVER OVER TOP OF PIPE. 8.WATER SERVICE LINE TO THE BUILDING SHALL HAVE A SHUT-OFF VALVE IN AN ACCESSIBLE LOCATION OUTSIDE OF THE BUILDING. (APPLIES TO COMMERCIAL ONLY) 9.STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH. 10.ALL UTILITY CROSSING AND CLEARANCES TO BE IN CONFORMANCE WITH THE REQUIREMENTS OF THE INDIANA STATE BOARD OF HEALTH. 11.IF EXISTING FIELD TILES ARE ENCOUNTERED DURING CONSTRUCTION THEY ARE TO BE TIED INTO THE PROPOSED STORM SEWER SYSTEM. 12.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. EXISTING LEGEND PLAN VIEW STR. 10-15 SCALE 1"=40' HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE