HomeMy WebLinkAboutC17 UTILITY PROFILESPROPOSED DRAINAGE STR. 10-15
900
905
910
915
920
925
900
905
910
915
920
925
910.97914.101+00911.07913.68910.79914.432+00910.56914.24910.78914.773+00911.53914.73912.28915.254+00912.83915.54913.12914.165+00912.91914.8315
T.R. 914.13R-347214
T.R. 914.06R-347213
T.R. 914.50R-3286-8V118 LF OF 21" RCP
@ 0.25% SLOPE
12
T.R. 914.19R-3286-8V113 LF OF 21" RCP
@ 0.35% SLOPE
11
T.R. 913.57R-3286-8V27"(W)907.940+05.0012"(W)910.456"(S)910.405+41.5889 LF OF 12" RCP
@ 0.64% SLOPE
12"(E)909.8818"(SW)909.796"(SE)909.606"(E)909.804+52.80129 LF OF 18" RCP
@ 0.46% SLOPE
18"(NE)909.2021"(S)909.106"(SE)909.206"(NE)909.2012"(NW)909.203+23.3821"(N)908.8021"(S)908.7012"(E)908.802+05.14113 LF OF 21" RCP
@ 0.35% SLOPE
21"(N)908.3012"(S)908.9627"(E)908.2012"(NW)908.308"(SE)907.800+92.1310
T.R. 910.96STR.PROPOSED GROUND EXISTING GROUND
87 LF OF 27" RCP
@ 0.30% SLOPE
PROFILE VIEW: 30:5
PVC SDR 35
TOP: 906.31
PROPOSED BUILDING
FFE: 916.60'
FPG:916.10'
LAG: 915.10'UTILITY EASEMENTUTILITY EASEMENTUTILITY EASEMENTUTILITY EASEMENTAA
EXISTING FIRE HYDRANT
CA CB
DA DB
POND 10 YEAR ELEV: 911.33'
POND 2 YEAR ELEV: 910.45'
915
9
1
5
915915915915
915 915915916916915910
915
915
911
912
913
914
910910908908909909
911914914915915915914914915915 9
1
5
913
914914TB 913.10
TB 913.55
914.60
912.82
914.20
913.10
914.26
TW 914.71
BW 911.54
TW 915.45
BW 911.60
BW 910.52
89 LF OF 12" RCP
@ 0.64%129 LF OF 18" RCP@ 0.46%118 LF OF 21" RCP
@ 0.25%113 LF OF 21" RCP@ 0.35%63 LF OF 12" RCP
@ 1.40%
71 LF OF 12" RCP
@ 0.95%223 LF OF 8" SDR 35 PVC@ 0.73%87 LF OF 27"
R
C
P
@ 0.30%56 LF OF 8" SDR 35 PVC@ 1.00%47 LF OF 6" SDR 3
5
P
V
C
@ 1.00%
3 LF OF 6" SDR 35 PVC
@ 1.00%
9 LF OF 6" SDR 35 PVC
@ 1.00%80 LF
OF
6"
SDR
35
PVC@ 2
.82%
41 LF OF 6" SDR 35 PVC
@ 4.33%
44 LF OF 6" SDR 35 PVC
@ 3.96%
9
0
L
F
O
F
6
"
SDR
3
5
PVC@
2
.
0
0%
77 LF OF 18" RCP
@ 0.33%
65 LF OF 6" SDR 35 PVC
@ 2.10%
17 LF OF 6" SDR 35 PVC
@ 1.71%
25 LF OF 6" SDR 35 PVC
@ 1.71%
60 LF OF 6" SDR 35 PVC
@ 0.83%
18 LF OF 6" SDR 35 PVC
@ 1.13%
STR. 13
Type C MH / R-3286-8V
TR: 914.50
INV(NE): 909.20
INV(S): 909.10
INV(SE): 909.20
INV(NE): 909.20
INV(NW): 909.20
STR. 12.2
Type C MH / R-3472
TR: 914.14
INV(W): 910.45
INV(NW): 911.00
INV(N): 911.64
INV(NW): 910.65
STR. 12.1
Type C MH / R-3472
TR: 914.01
INV(E): 909.57
INV(W): 909.47
INV(E): 909.57
INV(W): 910.45
INV(S): 910.40
STR. 12
Type C MH / R-3286-8V
TR: 914.19
INV(N): 908.80
INV(S): 908.70
INV(E): 908.80
STR. 11
Type C MH / R-3286-8V
TR: 913.57
INV(N): 908.30
INV(S): 908.96
INV(E): 908.20
INV(NW): 908.30
INV(SE): 907.80
STR. 11.1
24'' ADS2824 Basin / ADS 2499CGS
TR: 913.51
INV(SE): 910.00
STR. MH-ILC2
48 SANITARY MANHOLE
TR: 914.44
INV(N): 906.64
INV(S): 906.53
STR. 10
27" CES
INV(W): 907.94
STR. 11.2
AQUA-SWIRL/AS-8
STR. RD06
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.96
STR. RD05
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.96
PIV
WATER TEE
WATER TEE
45 Degree Bend
Fire Department Connnection
FIRE HYDRANT ASSEMBLY
FIRE HYDRANT ASSEMBLY
Refer to MEP Plan for Connection to
Building
INV: 910.96
Refer to MEP Plan for Connection to
Building
INV: 910.96
Refer to MEP Plan for Connection to
Building
INV: 910.96
STR. RD2.3
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.96STR. RD02.2
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.96
STR. RD01
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.96STR. RD03
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:912.96
STR. RD04.2
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:912.96
STR. RD04.3
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:912.96
STR. 3.4
SAN C/O. TYPE 3. Refer to MEP Plan
for Connection to Building
INV(SW): 911.60
STR. CES 2
18" CES
TR: 917.86
INV(N): 912.82
STR. RD10
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:909.50
STR. RD09
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.3
STR. RD07
ROOF DRAIN CONNECT TO
DOWNSPOUT BOOT[SEE DETAIL-C22]
INV:910.60
STR. SP01
Cleanout. Refer to MEP Plan for
Connection to Building and Backflow
Preventer
INV(S): 913.00
STR. OCS 1.0
TEE Water
45 Bend Water
45 Bend Water
STR. MH-ILC3
48 SANITARY DROP MANHOLE
TR: 915.90
INV(N): 911.29
INV(S): 907.20
INV(NE): 910.53
STR. 3.2
SAN C/O. TYPE 3
TR: 911.64
INV(E): 911.09
INV(W): 911.09
STR. 31
Type C MH / R-2560-EA-E10
TR: 913.25
INV(W): 909.39
STR. 30
12" CES
INV(E): 909.06
STR. 13.1
24'' ADS2824 Basin / ADS 2499CGS
TR: 913.91
INV(SE): 910.41
17 LF OF 12" RCP
@ 6.95%
S4
XB
XC
D3
D3
D3
D3
D3
D3
D3
W3
W3
W3
W2
W1
XD
XE
D5
W4
G1
G2
W5
D1
D1
D1
S1
W6
S2
S2
S2
S2
S2
S3
ISLAMIC LIFE CENTER14120 Shelborne Road, Carmel IN 46074Al Salam FoundationBENCHMARK DATA
DRAWN BY:CHECKED BY:TMJ 6280 N. Shadeland Avenue, Suite AIndianapolis, IN 46220Phone: (317) 598-6647 | www.theveridusgroup.comPROJECT NO.: 2020.0113
LEE 4 RESET ELEVATION 910.53 (NAVD 88)
A DNR TABLET FOUND IN TOP OF THE CONCRETE POST 15.3 FEET EAST OF
THE CENTERLINE OF SHELBORNE ROAD AND 1500 FEET SOUTH OF THE
ORIGINAL CENTERLINE OF 146TH STREET.
CSC TBM #156 ELEVATION 912.83
A 5/8" CAPPED REBAR SET ±12 FEET EAST OF THE CENTERLINE OF
SHELBORNE ROAD, ALSO ±760 FEET NORTH OF THE CENTERLINE OF 141ST
STREET.
CSC TBM #151 ELEVATION 912.59
A MAGNAIL WITH WASHER STAMPED "TSC CPT" FOUND AT THE END OF AN
ASPHALT PATH, ALSO ±335 FEET WEST OF THE CENTERLINE OF SHELBORNE
ROAD, ALSO ±25 FEET NORTH OF THE CENTERLINE OF 141ST STREET.
MWJPLOT SCALE: 1:1 EDIT DATE: 8/11/21 - 10:02 AM EDITED BY: MJACKSON DRAWING FILE: Z:\PROJECTS\2020\0113 - ISLAMIC LIFE CENTER\2. DESIGN\CAD\C15 UTILITY PLAN SOUTH.DWGPRINT DATE: 8/11/21GENERAL NOTES
PER INDIANA STATE LAW IS-69-1991. IT IS AGAINST
THE LAW TO EXCAVATE WITHOUT NOTIFYING THE
UNDERGROUND LOCATION SERVICE TWO (2)
WORKING DAYS BEFORE COMMENCING WORK.
UTILITY LEGEND
KEYNOTES
WATER LINE
TELEPHONE LINE
ELECTRIC LINE
GAS LINE
VALVE
WATER METER PIT
SANITARY SEWER LINE
HYDRANT
STORM SEWER LINE
ROOF DRAIN
CLEANOUT
(STORM & SANITARY)
BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION
PROVIDED BY CENTRAL STATES CONSULTING,LLC. PROJECT
NUMBER 20-043, DATED 06/07/2020.
C17
UTILITY PROFILES
1.IT SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL
EXISTING UTILITIES AND CONDITIONS PERTAINING TO THE PHASE OF
WORK. IT SHALL ALSO BE THE SUBCONTRACTOR'S RESPONSIBILITY
TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER
STAKE LOCATION OF EACH UTILITY BEFORE WORK IS STARTED. EACH
SUBCONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER OF ANY
CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN
FIELD BEFORE WORK IS STARTED OR RESUMED.
2.ALL MATERIALS AND CONSTRUCTION FOR SANITARY SEWERS SHALL
BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND
SPECIFICATIONS.
3.ALL MATERIALS AND CONSTRUCTION FOR STORM SEWERS SHALL BE
IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND
SPECIFICATIONS.
4.ALL MATERIALS AND CONSTRUCTION FOR WATER MAINS SHALL BE IN
ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND
SPECIFICATIONS.
5.ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING
UNDER OR WITHIN 5' OF PAVED AREAS TO BE BACKFILLED WITH
COMPACTED GRANULAR MATERIAL.
6.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO
CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS.
7.ANY WATER MAINS TO HAVE 54" MINIMUM COVER OVER TOP OF
PIPE.
8.WATER SERVICE LINE TO THE BUILDING SHALL HAVE A SHUT-OFF
VALVE IN AN ACCESSIBLE LOCATION OUTSIDE OF THE BUILDING.
(APPLIES TO COMMERCIAL ONLY)
9.STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH
STATE BOARD OF HEALTH.
10.ALL UTILITY CROSSING AND CLEARANCES TO BE IN CONFORMANCE
WITH THE REQUIREMENTS OF THE INDIANA STATE BOARD OF
HEALTH.
11.IF EXISTING FIELD TILES ARE ENCOUNTERED DURING CONSTRUCTION
THEY ARE TO BE TIED INTO THE PROPOSED STORM SEWER SYSTEM.
12.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN
SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL
APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED
DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR
DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD
APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL
IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN
EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A
REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE
OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS
GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT
FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE
TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE
CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE
AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN
PLANS AND AS APPROVED BY THE CITY OF CARMEL.
EXISTING LEGEND
PLAN VIEW STR. 10-15
SCALE 1"=40'
HYDRAULIC GRADE LINE
HYDRAULIC GRADE LINE