Loading...
HomeMy WebLinkAboutC18 UTILITY PROFILESPROPOSED DRAINAGE STR. 13- 13.1 905 910 915 920 905 910 915 920 PROPOSED DRAINAGE STR. 12-12.2 905 910 915 920 925 905 910 915 920 925 PROPOSED DRAINAGE STR. 11- 11.1 905 910 915 920 905 910 915 920 PROPOSED DRAINAGE STR. 20- 23 900 905 910 915 920 925 900 905 910 915 920 925 911.29911.311+00911.69915.17912.02914.712+00912.43913.38912.86913.863+00912.83913.79912.60913.8912"(SW)911.523+52.6912"(W)909.9512"(NE)910.052+71.9312"(N)909.3712"(E)909.471+13.2012"(S)909.000+05.0023 T.R. 913.82R-2560-EA-E1081 LF OF 12" RCP @ 1.82% SLOPE 22 T.R. 913.25R-2560-EA-E10159 LF OF 12" RCP @ 0.30% SLOPE 21 T.R. 912.60R-2560-EA-E10108 LF OF 12" RCP @ 0.34% SLOPE 20 T.R. 910.67STR.PROPOSED GROUND EXISTING GROUND PROPOSED DRAINAGE STR. 11- 11.4 905 910 915 920 905 910 915 920 911.13914.111+00911.19914.13911.03914.601+00911.76914.3721"(N)908.3012"(S)908.9627"(E)908.2012"(NW)908.308"(SE)907.800+05.0012"(NE)910.061+09.9310 LF OF 12" RCP @ 0.33% SLOPE 12"(N)909.9312"(SW)910.030+99.9511 T.R. 913.57R-3286-8V11.4 T.R. 913.56NYLOPLAST 24" INLET11.3 T.R. 914.10R-3286-8V95 LF OF 12" RCP @ 1.02% SLOPE 11 T.R. 913.57R-3286-8V12"(SE)910.000+21.3921"(N)908.3012"(S)908.9627"(E)908.2012"(NW)908.308"(SE)907.800+05.0011.1 T.R. 913.51STR.16 LF OF 12" RCP @ 10.37% SLOPE 18"(NE)909.2021"(S)909.106"(SE)909.206"(NE)909.2012"(NW)909.200+05.0012"(SE)910.410+22.3813 T.R. 914.50R-3286-8V13.1 T.R. 913.91NYLOPLAST 24" INLET17 LF OF 12" RCP @ 6.95% SLOPE 21"(N)908.8021"(S)908.7012"(E)908.800+05.0112"(W)910.456"(NW)911.006"(N)911.646"(NW)910.651+38.8312"(E)909.5712"(W)909.476"(E)909.570+75.8312 T.R. 914.19R-3286-8V71 LF OF 12" RCP @ 0.95% SLOPE 12.2 T.R. 914.14R-347263 LF OF 12" RCP @ 1.40% SLOPE 12.1 T.R. 914.01R-3472PROPOSED GROUND PROPOSED GROUND PROPOSED GROUND EXISTING GROUND EXISTING GROUNDEXISTING GROUNDEXISTING GROUND PROPOSED GROUND PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PVC SDR 35 TOP: 907.15 PROPOSED DRAINAGE STR. 10-15900905910915920925900905910915920925 N/AN/AN/AN/AN/AN/AN/AN/A PROPOSED DRAINAGE STR. 13- 13.1905910915920905910915920PROPOSED DRAINAGE STR. 12-12.2905910915920925905910915920925PROPOSED DRAINAGE STR. 11- 11.190591091592090591091592015 T.R. 914.13R-347214 R-347213 R-3286-8V@ 0.25% SLOPE12 R-3286-8V@ 0.35% SLOPE11 R-3286-8V12"(W)910.45@ 0.64% SLOPE12"(E)909.8818"(SW)909.79@ 0.46% SLOPE18"(NE)909.2012"(NW)909.2012"(E)908.80@ 0.35% SLOPE12"(S)908.9612"(NW)908.3010 STR.PROPOSED GROUND EXISTING GROUND PROPOSED SANITARY STR. EX SAN1-MH-ILC3900905910915920900905910915920@ 0.30% SLOPE PROPOSED DRAINAGE STR. 20- 2390090591091592092590090591091592092512"(SW)911.5212"(W)909.9512"(NE)910.0512"(N)909.3712"(E)909.471+13.2012"(S)909.0023 R-2560-EA-E1081 LF OF 12" RCP @ 1.82% SLOPE22 R-2560-EA-E10@ 0.30% SLOPE21 R-2560-EA-E10@ 0.34% SLOPE20 STR.PROPOSED GROUNDEXISTING GROUND PROPOSED DRAINAGE STR. 30 - STR. 31905910915920905910915920PROPOSED DRAINAGE STR. 11- 11.4905910915920905910915920PROPOSED DRAINAGE STR. EX1-OCS1900905910915920900905910915920PROPOSED DRAINAGE STR.40-4190591091592090591091592010 LF OF 12" RCP11 T.R. 913.57R-3286-8VT.R. 913.56NYLOPLAST 24" INLETT.R. 914.10R-3286-8V@ 1.02% SLOPE11 T.R. 913.57R-3286-8VT.R. 913.51STR.16 LF OF 12" RCP13 T.R. 914.50R-3286-8VT.R. 913.91NYLOPLAST 24" INLET17 LF OF 12" RCP12"(E)908.8012"(W)910.451+38.8312"(E)909.5712"(W)909.4712 R-3286-8V@ 0.95% SLOPE R-3472@ 1.40% SLOPE R-347231 T.R. 913.25R-2560-EA-E10@ 0.33% SLOPE30 T.R. 910.30???T.R. 909.47ex storm inletT.R. 911.32R-434212"(W)909.8812"(E)906.4412"(S)906.7241 R-2560-EA-E10@ 1.24% SLOPE ex storm inlet1+63.86SANITARY MH@ 1.00% SLOPE SANITARY MH@ 0.73% SLOPE SANITARY MH@ 0.56% SLOPE exist sanitary mh30 LF OF 12" RCP@ 0.15% SLOPEPROPOSED GROUND PROPOSED GROUND PROPOSED GROUND PROPOSED GROUND PROPOSED GROUND PROPOSED GROUNDPROPOSED GROUNDEXISTING GROUND EXISTING GROUND EXISTING GROUND EXISTING GROUNDEXISTING GROUNDEXISTING GROUNDEXISTING GROUNDEXISTING GROUND PROPOSED GROUNDPROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PVC SDR 35 TOP: 907.15 PVC SDR 35 TOP: 906.31 PVC SDR 35 TOP: 905.81 RCP BOTTOM: 909.51 RCP BOTTOM: 906.38 RCP BOTTOM: 907.87 RCP BOTTOM: 908.82 CA 913914914914TB 913.55  914.20 TW 914.77 BW 911.31 95 LF OF 12" RCP@ 1.02%159 LF OF 8" SDR 35 PVC118 LF OF 12" RCP @ 0.15% STR. 11 Type C MH / R-3286-8V TR: 913.57 INV(N): 908.30 INV(S): 908.96 INV(E): 908.20 INV(NW): 908.30 INV(SE): 907.80 STR. 11.1 24'' ADS2824 Basin / ADS 2499CGS TR: 913.51 INV(SE): 910.00 STR. 11.2 AQUA-SWIRL/AS-8 [SEE DETAIL-C22] TR: 913.76 STR. EX.1 EXISTING STRUCTURE INV(E): 906.44 INV(S): 906.72 STR. 11.3 Type C MH / R-3286-8V TR: 914.10 INV(N): 909.93 INV(SW): 910.03 XA XB D3 D3 D5 S2 S2 CA 915 913 914 914914TB 913.55  914.20 113 LF OF 21" RCP87 LF OF 27" R C P STR. 11 Type C MH / R-3286-8V TR: 913.57 INV(N): 908.30 INV(S): 908.96 INV(E): 908.20 INV(NW): 908.30 INV(SE): 907.80 STR. 11.1 24'' ADS2824 Basin / ADS 2499CGS TR: 913.51 INV(SE): 910.00 STR. 11.2 AQUA-SWIRL/AS-8 XB D3 S2 914914915TW 915.45 41 LF OF 6" SDR 35 PVC @ 4.33% STR. 13 Type C MH / R-3286-8V TR: 914.50 INV(NE): 909.20 INV(S): 909.10 INV(SE): 909.20 INV(NE): 909.20 INV(NW): 909.20 DOWNSPOUT BOOT[SEE DETAIL-C22] DOWNSPOUT BOOT[SEE DETAIL-C22] STR. MH-ILC3 48 SANITARY DROP MANHOLE TR: 915.90 INV(N): 911.29 STR. 13.1 24'' ADS2824 Basin / ADS 2499CGS TR: 913.91 INV(SE): 910.41 17 LF OF 12" RCP @ 6.95% S4 D3 S1 S2 915915 915915915 TW 914.71 BW 911.54 118 LF OF 21" RCP @ 0.25%113 LF OF 21" RCP@ 0.35%63 LF OF 12" RCP @ 1.40% 71 LF OF 12" RCP @ 0.95%223 LF OF 8" SDR 35 PVC@ 0.73%56 LF OF 8" SDR 35 PVC@ 1.00%47 LF OF 6" SDR 3 5 P V C @ 1.00% 3 LF OF 6" SDR 35 PVC @ 1.00% 9 LF OF 6" SDR 35 PVC @ 1.00%80 LF OF 6" SDR 35 PVC@ 2 .82% 65 LF OF 6" SDR 35 PVC @ 2.10% 17 LF OF 6" SDR 35 PVC @ 1.71% 25 LF OF 6" SDR 35 PVC @ 1.71% STR. 12.2 Type C MH / R-3472 TR: 914.14 INV(W): 910.45 INV(NW): 911.00 INV(N): 911.64 INV(NW): 910.65 STR. 12.1 Type C MH / R-3472 TR: 914.01 INV(E): 909.57 INV(W): 909.47 INV(E): 909.57 STR. 12 Type C MH / R-3286-8V TR: 914.19 INV(N): 908.80 INV(S): 908.70 INV(E): 908.80 STR. MH-ILC2 48 SANITARY MANHOLE TR: 914.44 INV(N): 906.64 INV(S): 906.53 STR. RD06 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.96 STR. 3.4 SAN C/O. TYPE 3. Refer to MEP Plan for Connection to Building INV(SW): 911.60 STR. RD10 ROOF DRAIN CONNECT TO STR. RD09 ROOF DRAIN CONNECT TO DOWNSPOUT BOOT[SEE DETAIL-C22] INV:910.3 Cleanout. Refer to MEP Plan for Connection to Building and Backflow Preventer INV(S): 913.00 INV(S): 907.20 INV(NE): 910.53 XC D3 D3 D3 XD XE D1 S2 S2 S2 S2 S3 141ST STREET UTILITY EASEMENTUTILITY EASEMENTAB EXISTING FIRE HYDRANT SPILLWAY LOCATION REFER TO UTILITY DETAILS910 91591 5 909911912913913 9 1 4 914 916916 914914915915TB 913.10 TB 913.10 TB 913.10  913.72  914.90  913.85  913.65  914.98  914.08 TB 913.10 912.53 TW 915.06 BW 911.22 159 LF OF 8" SDR 35 PVC@ 0.56%108 LF OF 12" RCP@ 0.34%81 LF OF 12" RCP@ 1.82% STR. EX SAN1 48 SANITARY MANHOLE TR: 911.82 INV(N): 903.90 INV(W): 903.80 STR. 23 Type C MH / R-2560-EA-E10 CONNECT TO EXISITNG 12" CMP TR: 913.82 INV(SW): 911.52 STR. 20 12" CES INV(S): 909.00 STR. 21 Type C MH / R-2560-EA-E10 TR: 912.60 STR. 22 Type C MH / R-2560-EA-E10 TR: 913.25 INV(W): 909.95 INV(NE): 910.05 159 LF O F 1 2 " R C P @ 0.30% STR. 41 Type C MH / R-2560-EA-E10 CONNECT TO EXISTING 12" CMP TR: 913.29217 LF OF 12" RCP@ 1.24%STR. MH-ILC1 48 SANITARY MANHOLE TR: 914.45 INV(N): 904.90 INV(S): 904.79 38 LF OF 12" RCP @ 1.00%D1 D5D5 D5 G1 D1 D1 S2 PLOT SCALE: 1:1 EDIT DATE: 8/11/21 - 10:02 AM EDITED BY: MJACKSON DRAWING FILE: Z:\PROJECTS\2020\0113 - ISLAMIC LIFE CENTER\2. DESIGN\CAD\C15 UTILITY PLAN SOUTH.DWGPRINT DATE: 8/11/21GENERAL NOTES PER INDIANA STATE LAW IS-69-1991. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. UTILITY LEGEND KEYNOTES WATER LINE TELEPHONE LINE ELECTRIC LINE GAS LINE VALVE WATER METER PIT SANITARY SEWER LINE HYDRANT STORM SEWER LINE ROOF DRAIN CLEANOUT (STORM & SANITARY) BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY CENTRAL STATES CONSULTING,LLC. PROJECT NUMBER 20-043, DATED 06/07/2020. C18 UTILITY PROFILESISLAMIC LIFE CENTER14120 Shelborne Road, Carmel IN 46074Al Salam FoundationBENCHMARK DATA DRAWN BY:CHECKED BY:TMJ 6280 N. Shadeland Avenue, Suite AIndianapolis, IN 46220Phone: (317) 598-6647 | www.theveridusgroup.comPROJECT NO.: 2020.0113 LEE 4 RESET ELEVATION 910.53 (NAVD 88) A DNR TABLET FOUND IN TOP OF THE CONCRETE POST 15.3 FEET EAST OF THE CENTERLINE OF SHELBORNE ROAD AND 1500 FEET SOUTH OF THE ORIGINAL CENTERLINE OF 146TH STREET. CSC TBM #156 ELEVATION 912.83 A 5/8" CAPPED REBAR SET ±12 FEET EAST OF THE CENTERLINE OF SHELBORNE ROAD, ALSO ±760 FEET NORTH OF THE CENTERLINE OF 141ST STREET. CSC TBM #151 ELEVATION 912.59 A MAGNAIL WITH WASHER STAMPED "TSC CPT" FOUND AT THE END OF AN ASPHALT PATH, ALSO ±335 FEET WEST OF THE CENTERLINE OF SHELBORNE ROAD, ALSO ±25 FEET NORTH OF THE CENTERLINE OF 141ST STREET. MWJ 1.IT SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THE PHASE OF WORK. IT SHALL ALSO BE THE SUBCONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION OF EACH UTILITY BEFORE WORK IS STARTED. EACH SUBCONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN FIELD BEFORE WORK IS STARTED OR RESUMED. 2.ALL MATERIALS AND CONSTRUCTION FOR SANITARY SEWERS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 3.ALL MATERIALS AND CONSTRUCTION FOR STORM SEWERS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 4.ALL MATERIALS AND CONSTRUCTION FOR WATER MAINS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 5.ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVED AREAS TO BE BACKFILLED WITH COMPACTED GRANULAR MATERIAL. 6.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 7.ANY WATER MAINS TO HAVE 54" MINIMUM COVER OVER TOP OF PIPE. 8.WATER SERVICE LINE TO THE BUILDING SHALL HAVE A SHUT-OFF VALVE IN AN ACCESSIBLE LOCATION OUTSIDE OF THE BUILDING. (APPLIES TO COMMERCIAL ONLY) 9.STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH. 10.ALL UTILITY CROSSING AND CLEARANCES TO BE IN CONFORMANCE WITH THE REQUIREMENTS OF THE INDIANA STATE BOARD OF HEALTH. 11.IF EXISTING FIELD TILES ARE ENCOUNTERED DURING CONSTRUCTION THEY ARE TO BE TIED INTO THE PROPOSED STORM SEWER SYSTEM. 12.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. EXISTING LEGEND 0'30'60' SCALE: 1"=30' PLAN VIEW STR. 11-11.4 SCALE 1"=30' PLAN VIEW STR. 11-11.1 SCALE 1"=20'PLAN VIEW STR. 13-13.1 SCALE 1"=20' PLAN VIEW STR. 12-12.2 SCALE 1"=30' PLAN VIEW STR. 20-23 SCALE 1"=40' HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE