HomeMy WebLinkAboutC19.0 UTILITY PROFILESPROPOSED DRAINAGE STR. 30 - STR. 31 905 910 915 920 905 910 915 920 913.06913.061+00913.76913.76PROPOSED DRAINAGE STR. EX1-OCS1 900 905 910 915 920 900 905 910 915 920 PROPOSED DRAINAGE STR.40-41 905 910 915 920 905 910 915 920 1+00 911.14914.892+00910.29915.44911.27914.531+00911.05913.42911.13907.3712"(W)909.391+03.1612"(E)909.060+05.0031 T.R. 913.24R-2560-EA-E1098 LF OF 12" RCP @ 0.33% SLOPE 30 T.R. 910.30???EX.1 T.R. 909.47ex storm inletOCS 1.0 T.R. 908.00OCS 1.0A T.R. 911.32R-434212"(W)909.882+23.4912"(E)906.4412"(S)906.720+05.0041 T.R. 913.29R-2560-EA-E10217 LF OF 12" RCP @ 1.24% SLOPE EX.1 T.R. 909.47ex storm inlet12"(E)906.4412"(S)906.720+05.0012"(W)906.771+53.6930 LF OF 12" RCP @ 0.17% SLOPE 12"(W)906.6212"(E)906.721+23.35118 LF OF 12" RCP @ 0.15% SLOPE PROPOSED GROUND PROPOSED GROUND PROPOSED GROUND EXISTING GROUND EXISTING GROUND EXISTING GROUND PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PROFILE VIEW: 30:5 PVC SDR 35 TOP: 905.81 RCP BOTTOM: 909.51UTILITY EASEMENTUTILITY EASEMENTCB POND 10 YEAR ELEV: 911.33' POND 2 YEAR ELEV: 910.45'910911912913914 913.10 STR. 31 Type C MH / R-2560-EA-E10 TR: 913.24 INV(W): 909.39 STR. 30 12" CES INV(E): 909.06 D1 BA CA 910908908909909 911912913910909911914914 914.20 TW 914.77 BW 911.31 95 LF OF 12" RCP@ 1.02%118 LF OF 12" RCP @ 0.15% STR. 11.2 AQUA-SWIRL/AS-8 [SEE DETAIL-C22] TR: 913.76 STR. EX.1 EXISTING STRUCTURE INV(E): 906.44 INV(S): 906.72 STR. OCS 1.0A OCS[SEE DETAIL-C22]/ R-4342 INV(W): 906.62 INV(E): 906.72 STR. OCS 1.0 12 CES INV(W): 906.77 STR. 11.3 Type C MH / R-3286-8V 30 LF OF 12" RCP @ 0.17% XA D3 D5 S2 141ST STREET AB BA BB911912913 91091591 5 909911912913913 9 1 4 914 916916 910909911912915914915TB 913.10  913.90  914.98 TB 913.10 912.70 TW 915.06 BW 911.22 TW 914.77 BW 911.31 95 LF OF 12" RCP@ 1.02%159 LF OF 8" SDR 35 PVC@ 0.56%108 LF OF 12" RCP@ 0.28%118 LF OF 12" RCP @ 0.15% STR. EX SAN1 48 SANITARY MANHOLE TR: 911.82 INV(N): 903.90 INV(W): 903.80 [SEE DETAIL-C22] TR: 913.76 STR. 20 12" CES INV(S): 909.00 STR. 21 Type C MH / R-2560-EA-E10 TR: 912.91 INV(N): 909.30 STR. EX.1 EXISTING STRUCTURE INV(E): 906.44 INV(S): 906.72 STR. OCS 1.0A OCS[SEE DETAIL-C22]/ R-4342 INV(W): 906.62 INV(E): 906.72 159 LF O F 1 2 " R C P @ 0.29% STR. 41 Type C MH / R-2560-EA-E10 CONNECT TO EXISTING 12" CMP TR: 913.29 INV(W): 909.88217 LF OF 12" RCP@ 1.24%STR. OCS 1.0 12 CES INV(W): 906.77 STR. 11.3 Type C MH / R-3286-8V TR: 914.10 INV(N): 909.93 INV(SW): 910.03 STR. MH-ILC1 48 SANITARY MANHOLE TR: 914.45 INV(N): 904.90 INV(S): 904.79 30 LF OF 12" RCP @ 0.17% 38 LF OF 12" RCP @ 1.00%STR. 40 Type C MH / R-1714 TR: 913.66 INV(N): 909.40 INV(E): 909.50 D1 XA D3 D5 D5 D5 D1 S2 S2 PLOT SCALE: 1:1 EDIT DATE: 8/31/21 - 11:21 AM EDITED BY: MJACKSON DRAWING FILE: Z:\PROJECTS\2020\0113 - ISLAMIC LIFE CENTER\2. DESIGN\CAD\C15 UTILITY PLAN SOUTH.DWGPRINT DATE: 8/31/21GENERAL NOTES UTILITY LEGEND KEYNOTES WATER LINE TELEPHONE LINE ELECTRIC LINE GAS LINE VALVE WATER METER PIT SANITARY SEWER LINE HYDRANT STORM SEWER LINE ROOF DRAIN CLEANOUT (STORM & SANITARY) BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY CENTRAL STATES CONSULTING,LLC. PROJECT NUMBER 20-043, DATED 06/07/2020. C19 UTILITY PROFILESISLAMIC LIFE CENTER14120 Shelborne Road, Carmel IN 46074Al Salam FoundationBENCHMARK DATA DRAWN BY:CHECKED BY:TMJ 6280 N. Shadeland Avenue, Suite AIndianapolis, IN 46220Phone: (317) 598-6647 | www.theveridusgroup.comPROJECT NO.: 2020.0113 LEE 4 RESET ELEVATION 910.53 (NAVD 88) A DNR TABLET FOUND IN TOP OF THE CONCRETE POST 15.3 FEET EAST OF THE CENTERLINE OF SHELBORNE ROAD AND 1500 FEET SOUTH OF THE ORIGINAL CENTERLINE OF 146TH STREET. CSC TBM #156 ELEVATION 912.83 A 5/8" CAPPED REBAR SET ±12 FEET EAST OF THE CENTERLINE OF SHELBORNE ROAD, ALSO ±760 FEET NORTH OF THE CENTERLINE OF 141ST STREET. CSC TBM #151 ELEVATION 912.59 A MAGNAIL WITH WASHER STAMPED "TSC CPT" FOUND AT THE END OF AN ASPHALT PATH, ALSO ±335 FEET WEST OF THE CENTERLINE OF SHELBORNE ROAD, ALSO ±25 FEET NORTH OF THE CENTERLINE OF 141ST STREET. MWJ 1.IT SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THE PHASE OF WORK. IT SHALL ALSO BE THE SUBCONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION OF EACH UTILITY BEFORE WORK IS STARTED. EACH SUBCONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN FIELD BEFORE WORK IS STARTED OR RESUMED. 2.ALL MATERIALS AND CONSTRUCTION FOR SANITARY SEWERS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 3.ALL MATERIALS AND CONSTRUCTION FOR STORM SEWERS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 4.ALL MATERIALS AND CONSTRUCTION FOR WATER MAINS SHALL BE IN ACCORDANCE WITH THE LOCAL AUTHORITY STANDARDS AND SPECIFICATIONS. 5.ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVED AREAS TO BE BACKFILLED WITH COMPACTED GRANULAR MATERIAL. 6.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 7.ANY WATER MAINS TO HAVE 54" MINIMUM COVER OVER TOP OF PIPE. 8.WATER SERVICE LINE TO THE BUILDING SHALL HAVE A SHUT-OFF VALVE IN AN ACCESSIBLE LOCATION OUTSIDE OF THE BUILDING. (APPLIES TO COMMERCIAL ONLY) 9.STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH. 10.ALL UTILITY CROSSING AND CLEARANCES TO BE IN CONFORMANCE WITH THE REQUIREMENTS OF THE INDIANA STATE BOARD OF HEALTH. 11.IF EXISTING FIELD TILES ARE ENCOUNTERED DURING CONSTRUCTION THEY ARE TO BE TIED INTO THE PROPOSED STORM SEWER SYSTEM. 12.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. EXISTING LEGEND 0'30'60' SCALE: 1"=30' PLAN VIEW STR. 30-31 SCALE 1"=20' PLAN VIEW STR. EX01-OCS1 SCALE 1"=20' PLAN VIEW STR.40-41 SCALE 1"=40' HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE HYDRAULIC GRADE LINE