Loading...
HomeMy WebLinkAboutA10 Stair & Elevator SectionF L - - - H C ct (see ec nical) rooftop HVAC unit (see mechanical) 12113 11 ------------------------- Fill I—oteel beam per citructural /-7'-0" min. clearance (typical each otair) board rJ 4'-9" V2' filler 7114"rf ,3" 1" nosing °. .ap. (typical) ----- --� -- -- /-- / \ / s 1/ - - - - - - \�� I---- 1-1/2" dia. painted Steel handrail with brackets mounted to wall Studs (typical) m \ 24" deep wo� o�age cabinets- 2" Steel pan Stair with concrete tread and L — 44t14--0lagiv tandr — 'a.,' Schedule floor finish (typical) �\ (part �f add ate nr ate #3) 2" wide painted Steel Stringer, coordinate with Structural (typical) - PVC dumbbell wateretop (typical at ext. wall) X All STAIR AND ELEVATOR SECTION Scale: 1/2"=1'-0" (1:24) North Stair Similar, opposite hand expansion joint J' w/wateretop (typ. all 00e6) s U N U ELEVATOK CV --,u I I I coord. w/elevator requirements A r— L- 1 In FAMILY KE5TPOOM membrane roofing with applied ribs (per roof plan) over 4" rigid insulation on metal deck and curved joists (typical) Cont. aluminum gutters & downspouts (typ) l TOP OF PARAPET 7 119'-4" EIF5 will finish over drainage mat with flashing at roof (typical, See wall sections & details) aluminum windows with insulating glass (typical) tubular Skylight on curb with flashing (typical) downspout piping Sloped to drain (see plane,) membrane roofing over 4" rigid and tapered insulation on metal deck and Steel joists (typical) steel hoist beam (coordinate with elevator supplier & contractor) soffits and cove lights in central corridor beyond concrete block walls around elevator Shaft, extended and Sealed to bottom of Steel deck and coordinate lintels & bond beams with elevator Supplier (typical) Suspended acoustic ceiling System (typical) metal Stud framing at 16" o.c. with 5/8" gypsum board (typical) operable panel partition beyond wood doors with painted metal frames per door schedule (typical) --- Schedule base and floor finish over reinf. concrete Slab on metal decking over Steel joists (typical) l UPPER LEVEL 100'-0" (=915.96 per Civil) Suspended acoustic ceiling System (typical) HER I/g No. O Q� U 11900212 STA %/ �' • '/VD i PAP• CH T �-G\``\��� 524 East High Street Lexington KY 40502 mccoyarchitects.com te1859.233.1884 STAIR LANDING Al Salam Foundation 93' g ISLAMIC LIFE CENTER ELEVATO\ 14120 Shelborne Road EQUIPMENT Carmel IN 46074 Gono truction Drawings 3/17/2021 galvanized elevator pit ladder as required by code Schedule base and floor finish over reinf. concrete Slab over crushed Stone fill (typical) l LOWER LEVEL (=905.29' per Civil) 4" perforated foundation drain with filter Sock (typical at interior perimeter) to Sump pump RX waterstop all Sides (typical) PVC dumbbell wateretop (typical all Sides) 50TTOM OF ELEVATOR SHAFT m'-4" STAIR AND ELEVATOR SECTION A10