HomeMy WebLinkAboutGN010.4 Floor drawings4x8
4x8
3x4 3x4
3x6
21 20 19 18 17 16 15
23 24
1 2 3 4 5 6 7 8 9 10 11 12 13
W2W1 W3 W3BL1 BL1
B2
T1
B1
T2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-3-12,Edge], [4:0-1-12,Edge], [6:0-1-8,Edge], [7:0-1-8,Edge], [9:0-1-12,Edge], [12:0-3-12,Edge],[15:0-2-4,Edge], [21:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL)-0.42 17-18 >611 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.66 Vert(TL)-0.66 17-18 >390 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.81 Horiz(TL)0.11 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 86 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1167/0-3-8, (min. 0-1-8), 22=1167/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3297/0, 3-4=-3297/0, 4-5=-4938/0, 5-6=-4938/0, 6-7=-5149/0, 7-8=-4938/0, 8-9=-4938/0, 9-10=-3297/0,
10-11=-3297/0, 11-12=-3297/0
BOT CHORD 21-22=0/1877, 20-21=0/4301, 19-20=0/4301, 18-19=0/5149, 17-18=0/5149, 16-17=0/5149, 15-16=0/4301, 14-15=0/1877
WEBS 2-22=-2154/0, 12-14=-2154/0, 2-21=0/1646, 12-15=0/1646, 4-21=-1164/0, 9-15=-1164/0, 4-19=0/738, 9-16=0/738,
6-19=-667/214, 7-16=-667/214
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F01 38 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:50 Page: 1
ID:RLs5aR_Ca0KZke69oFou8Xyn_UB-1kxScri1cYUFvMW_5LN8dDXd8f0auFG3guiX2KzeGih
3x6 FP
1.5x3 4x6
4x8
3x4 1.5x3
3x4
3x4
1.5x3
3x6
3x4
17 16 15 14 13
19
1 2 3 4 5 6 7 8 9 10 11
W1 W2 W3 W3
B2
T1 T2
B1
BL1
Scale = 1:31.7
Plate Offsets (X, Y): [14:0-1-8,Edge], [15:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.24 14-15 >878 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.90 Vert(TL)-0.37 14-15 >563 360
BCLL 0.0 Rep Stress Incr YES WB 0.60 Horiz(TL)0.08 12 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 69 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)12=949/ Mechanical, (min. 0-1-8), 18=943/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2524/0, 3-4=-2524/0, 4-5=-3367/0, 5-6=-3367/0, 6-7=-3367/0, 7-8=-2523/0, 8-9=-2523/0, 9-10=-2523/0
BOT CHORD 17-18=0/1483, 16-17=0/1483, 15-16=0/3139, 14-15=0/3367, 13-14=0/3139, 12-13=0/1485
WEBS 2-18=-1701/0, 10-12=-1708/0, 2-16=0/1206, 10-13=0/1203, 4-16=-713/0, 7-13=-714/0, 4-15=-63/557, 7-14=-63/557,
5-15=-252/0, 6-14=-252/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F02 14 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:51 Page: 1
ID:RLs5aR_Ca0KZke69oFou8Xyn_UB-VwUqpBjfNrc6WV5Af3uNAR3lZ3I4dloCuYR4amzeGig
3x6 FP
1.5x3 4x6
4x8
3x4 1.5x3
3x4
3x4
1.5x3 1.5x3
17 16 15 14 13
19 20
1 2 3 4 5 6 7 8 9 10 11
W2W1 W3 W3BL1 BL1
B2
T1 T2
B1
Scale = 1:32.2
Plate Offsets (X, Y): [2:0-2-12,Edge], [10:0-2-12,Edge], [14:0-1-8,Edge], [15:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.54 Vert(LL)-0.25 14-15 >836 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.92 Vert(TL)-0.39 14-15 >539 360
BCLL 0.0 Rep Stress Incr YES WB 0.61 Horiz(TL)0.08 12 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 70 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 14-15.
REACTIONS (lb/size)12=959/0-3-8, (min. 0-1-8), 18=959/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2579/0, 3-4=-2579/0, 4-5=-3484/0, 5-6=-3484/0, 6-7=-3484/0, 7-8=-2579/0, 8-9=-2579/0, 9-10=-2579/0
BOT CHORD 17-18=0/1512, 16-17=0/1512, 15-16=0/3223, 14-15=0/3484, 13-14=0/3223, 12-13=0/1512
WEBS 2-18=-1734/0, 10-12=-1734/0, 2-16=0/1237, 10-13=0/1237, 4-16=-746/0, 7-13=-746/0, 4-15=-51/592, 7-14=-51/592
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are 1.5x3 MT20 unless otherwise indicated.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F03 12 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:51 Page: 1
ID:RLs5aR_Ca0KZke69oFou8Xyn_UB-VwUqpBjfNrc6WV5Af3uNAR3lE3IldleCuYR4amzeGig
4x6
4x8
3x4
3x4
3x4 3x4
23 22 21 20 19 17 16
25 261234567891011121314
W1 W2 W3 W3 W4 W4BL1 BL1
B2
T1
B1
T2
Scale = 1:37.8
Plate Offsets (X, Y): [12:0-1-8,Edge], [13:0-1-8,Edge], [15:0-2-0,Edge], [18:0-2-12,Edge], [19:0-3-0,Edge], [20:0-1-8,Edge], [21:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.77 Vert(LL)-0.24 21-23 >888 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.91 Vert(TL)-0.37 21-23 >562 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.67 Horiz(TL)0.07 18 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 87 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)15=-48/0-3-8, (min. 0-1-8), 18=1479/0-3-8, (min. 0-1-8),
24=903/0-3-8, (min. 0-1-8)
Max Uplift 15=-193 (LC 3)
Max Grav 15=133 (LC 4), 18=1479 (LC 1), 24=906 (LC 10)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2396/0, 3-4=-2396/0, 4-5=-3099/0, 5-6=-3099/0, 6-7=-3099/0, 7-8=-1998/0, 8-9=-1998/0, 9-10=0/795, 10-11=0/795,
11-12=0/795, 12-13=-40/351
BOT CHORD 23-24=0/1420, 22-23=0/2948, 21-22=0/2948, 20-21=0/3099, 19-20=0/2732, 18-19=0/846, 17-18=-351/40, 16-17=-351/40,
15-16=-351/40
WEBS 2-24=-1629/0, 9-18=-1823/0, 2-23=0/1132, 9-19=0/1345, 4-23=-639/0, 7-19=-858/0, 4-21=-123/471, 7-20=0/663,
6-20=-277/0, 12-18=-777/0, 13-15=-55/533
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 193 lb uplift at joint 15.
5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F04 2 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:51 Page: 1
ID:RLs5aR_Ca0KZke69oFou8Xyn_UB-VwUqpBjfNrc6WV5Af3uNAR3hf3IvdkiCuYR4amzeGig
4x6
4x8
3x4
3x4
3x4 3x4
23 22 21 20 19 17 16
25 261234567891011121314
W1 W2 W3 W3 W4 W4BL1 BL1
T1
B2B1
T2
Scale = 1:37.8
Plate Offsets (X, Y): [12:0-1-8,Edge], [13:0-1-8,Edge], [15:0-2-0,Edge], [18:0-2-12,Edge], [19:0-3-0,Edge], [20:0-1-8,Edge], [21:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.77 Vert(LL)-0.24 21-23 >888 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.91 Vert(TL)-0.37 21-23 >562 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.67 Horiz(TL)0.07 18 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 87 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)15=-48/0-3-8, (min. 0-1-8), 18=1479/0-3-8, (min. 0-1-8),
24=903/0-3-8, (min. 0-1-8)
Max Uplift 15=-193 (LC 5)
Max Grav 15=133 (LC 4), 18=1479 (LC 1), 24=906 (LC 10)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2396/0, 3-4=-2396/0, 4-5=-3099/0, 5-6=-3099/0, 6-7=-3099/0, 7-8=-1998/0, 8-9=-1998/0, 9-10=0/795, 10-11=0/795,
11-12=0/795, 12-13=-40/351
BOT CHORD 23-24=0/1420, 22-23=0/2948, 21-22=0/2948, 20-21=0/3099, 19-20=0/2732, 18-19=0/846, 17-18=-351/40, 16-17=-351/40,
15-16=-351/40
WEBS 2-24=-1629/0, 9-18=-1823/0, 2-23=0/1132, 9-19=0/1345, 4-23=-639/0, 7-19=-858/0, 4-21=-123/471, 7-20=0/663,
6-20=-277/0, 12-18=-777/0, 13-15=-55/533
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 193 lb uplift at joint 15.
5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F05 2 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:51 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-VwUqpBjfNrc6WV5Af3uNAR3hf3IvdkiCuYR4amzeGig
4x8
4x8
3x4 3x4
3x6
21 20 19 18 17 16 15
23 24
1 2 3 4 5 6 7 8 9 10 11 12 13
W2W1 W3 W3BL1 BL1
B2
T1
B1
T2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-3-12,Edge], [4:0-1-12,Edge], [6:0-1-8,Edge], [7:0-1-8,Edge], [9:0-1-12,Edge], [12:0-3-12,Edge],[15:0-2-4,Edge], [21:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL)-0.42 17-18 >611 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.66 Vert(TL)-0.65 17-18 >391 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.81 Horiz(TL)0.11 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 86 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1167/0-3-8, (min. 0-1-8), 22=1167/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3296/0, 3-4=-3296/0, 4-5=-4937/0, 5-6=-4937/0, 6-7=-5147/0, 7-8=-4937/0, 8-9=-4937/0, 9-10=-3296/0,
10-11=-3296/0, 11-12=-3296/0
BOT CHORD 21-22=0/1877, 20-21=0/4300, 19-20=0/4300, 18-19=0/5147, 17-18=0/5147, 16-17=0/5147, 15-16=0/4300, 14-15=0/1877
WEBS 2-22=-2154/0, 12-14=-2154/0, 2-21=0/1645, 12-15=0/1645, 4-21=-1164/0, 9-15=-1164/0, 4-19=0/738, 9-16=0/738,
6-19=-666/214, 7-16=-666/214
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F06 16 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:51 Page: 1
ID:Yadal3xhXoq7F1oOZPjy_hyn_UF-VwUqpBjfNrc6WV5Af3uNAR3ou3MpdiWCuYR4amzeGig
3x6 FP
3x4
3x6
4x8
1.5x3
3x4
1.5x3
3x4
3x4 4x6
17 16 15 14 13
191234567891011
W1 W2 W3 W3
B2
T1 T2
B1
BL1
Scale = 1:31.7
Plate Offsets (X, Y): [14:0-1-8,Edge], [15:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.24 14-15 >874 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.90 Vert(TL)-0.37 14-15 >563 360
BCLL 0.0 Rep Stress Incr YES WB 0.60 Horiz(TL)0.08 12 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 69 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)12=943/0-3-8, (min. 0-1-8), 18=950/ Mechanical, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2525/0, 3-4=-2525/0, 4-5=-3370/0, 5-6=-3370/0, 6-7=-3370/0, 7-8=-2525/0, 8-9=-2525/0, 9-10=-2525/0
BOT CHORD 17-18=0/1486, 16-17=0/1486, 15-16=0/3141, 14-15=0/3370, 13-14=0/3141, 12-13=0/1484
WEBS 2-18=-1709/0, 10-12=-1702/0, 2-16=0/1204, 10-13=0/1207, 4-16=-715/0, 7-13=-714/0, 4-15=-63/558, 7-14=-63/558,
5-15=-252/0, 6-14=-252/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F07 6 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-z72C0XjH89kz8fgNDmPciecwITdJMC2M7CBe6DzeGif
3x6 FP
3x6 FP
4x6 3x4
3x4
3x4
4x8
17 16 15 14 13
19
20 21
1 2 3 4 5 6 7 8 9 10 11
W2W1 W3 W3
B2
T1 T2
B1
BL2BL1
Scale = 1:32.2
Plate Offsets (X, Y): [2:0-2-12,Edge], [10:0-2-12,Edge], [14:0-1-8,Edge], [15:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.54 Vert(LL)-0.25 14-15 >843 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.92 Vert(TL)-0.39 14 >543 360
BCLL 0.0 Rep Stress Incr YES WB 0.62 Horiz(TL)0.08 12 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 70 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 14-15.
REACTIONS (lb/size)12=956/0-3-8, (min. 0-1-8), 18=963/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2543/0, 3-4=-2543/0, 4-5=-3464/0, 5-6=-3464/0, 6-7=-3464/0, 7-8=-2570/0, 8-9=-2570/0, 9-10=-2570/0
BOT CHORD 17-18=0/1470, 16-17=0/1470, 15-16=0/3195, 14-15=0/3464, 13-14=0/3209, 12-13=0/1507
WEBS 2-18=-1703/0, 10-12=-1729/0, 2-16=0/1244, 10-13=0/1232, 4-16=-755/0, 7-13=-741/0, 4-15=-43/598, 7-14=-55/586,
5-15=-250/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are 1.5x3 MT20 unless otherwise indicated.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F08 8 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-z72C0XjH89kz8fgNDmPciecwzTd_MCkM7CBe6DzeGif
1.5x3 3x4
1.5x3
1.5x3
3x4
3x5
8
7 6
5
9 10
1 2 3 4
W1 W2BL1 BL1
B1
T1
Scale = 1:25.7
Plate Offsets (X, Y): [2:0-1-8,Edge], [3:0-1-8,Edge], [5:0-2-0,Edge], [8:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.10 Vert(LL)0.00 7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.07 Vert(TL)0.00 7 >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.06 Horiz(TL)0.00 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 19 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=204/0-3-8, (min. 0-1-8), 8=204/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F09 2 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-z72C0XjH89kz8fgNDmPciec1rTqGMLVM7CBe6DzeGif
1.5x3 3x4
1.5x3
1.5x3
3x4
3x5
8
7 6
5
9 10
1 2 3 4
W1 W2BL1 BL1
B1
T1
Scale = 1:28
Plate Offsets (X, Y): [2:0-1-8,Edge], [3:0-1-8,Edge], [5:0-2-0,Edge], [8:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.10 Vert(LL)0.00 7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.07 Vert(TL)0.00 7 >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.06 Horiz(TL)0.00 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 19 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-14 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=204/0-3-7, (min. 0-1-8), 8=204/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F10 2 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-z72C0XjH89kz8fgNDmPciec1rTqGMLVM7CBe6DzeGif
3x4
5x6
3x5
3x5
1 5 2
W1
T1T1
B1
W2
Scale = 1:19.2
Plate Offsets (X, Y): [1:Edge,0-2-0], [2:Edge,0-1-8], [3:0-2-0,Edge], [4:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.97 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.04 Vert(TL)-0.01 3-4 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.00 Horiz(TL)n/a -n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MP Weight: 15 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-6-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)3=691/ Mechanical, (min. 0-1-8), 4=499/ Mechanical, (min.
0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-4=-488/0, 2-3=-680/0
NOTES
1)Refer to girder(s) for truss to truss connections.
2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
4)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)944 lb down at 1-5-12 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 3-4=-10, 1-2=-100
Concentrated Loads (lb)
Vert: 5=-944
Job Truss Truss Type Qty Ply .
F11 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-z72C0XjH89kz8fgNDmPciecpFTrlMLQM7CBe6DzeGif
3x6 FP
3x4
3x6
1.5x3
3x4
6x6 3x4 4x8
21 20 1918 1716 15
2312345678910111213
W1 W2 W3 W3
B2
T1 T2
B1
BL1
Scale = 1:34.2
Plate Offsets (X, Y): [5:0-1-8,Edge], [8:0-1-8,Edge], [15:0-3-0,Edge], [20:0-3-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.50 Vert(LL)-0.32 17-18 >704 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.77 Vert(TL)-0.50 17-18 >449 360
BCLL 0.0 Rep Stress Incr YES WB 0.68 Horiz(TL)0.09 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 79 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat) *Except* B2:2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-8-3 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1032/0-3-7, (min. 0-1-8), 22=1038/ Mechanical, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2830/0, 3-4=-2830/0, 4-5=-4012/0, 5-6=-4012/0, 6-7=-4028/0, 7-8=-4012/0, 8-9=-4012/0, 9-10=-2830/0,
10-11=-2830/0, 11-12=-2830/0
BOT CHORD 21-22=0/1642, 20-21=0/1642, 19-20=0/3606, 18-19=0/4028, 17-18=0/4028, 16-17=0/4028, 15-16=0/3606, 14-15=0/1641
WEBS 2-22=-1889/0, 12-14=-1882/0, 2-20=0/1376, 12-15=0/1378, 4-20=-900/0, 9-15=-899/0, 4-19=0/580, 5-19=-331/224,
9-16=0/580, 8-16=-331/224, 6-19=-692/517, 7-16=-691/517, 6-18=-299/261, 7-17=-300/261
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F12 2 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-z72C0XjH89kz8fgNDmPciecxbTfLMBoM7CBe6DzeGif
3x6 FP
1.5x3 4x6
4x8
3x4 1.5x3
3x4
3x4
1.5x3
3x6
3x4
17 16 15 14 13
19
1 2 3 4 5 6 7 8 9 10 11
W1 W2 W3 W3
B2
T1 T2
B1
BL1
Scale = 1:31.7
Plate Offsets (X, Y): [14:0-1-8,Edge], [15:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.24 14-15 >877 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.90 Vert(TL)-0.37 14-15 >564 360
BCLL 0.0 Rep Stress Incr YES WB 0.60 Horiz(TL)0.08 12 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 69 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)12=949/ Mechanical, (min. 0-1-8), 18=943/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2523/0, 3-4=-2523/0, 4-5=-3365/0, 5-6=-3365/0, 6-7=-3365/0, 7-8=-2523/0, 8-9=-2523/0, 9-10=-2523/0
BOT CHORD 17-18=0/1483, 16-17=0/1483, 15-16=0/3138, 14-15=0/3365, 13-14=0/3138, 12-13=0/1485
WEBS 2-18=-1701/0, 10-12=-1708/0, 2-16=0/1205, 10-13=0/1203, 4-16=-713/0, 7-13=-713/0, 4-15=-63/557, 7-14=-63/557,
5-15=-252/0, 6-14=-252/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F13 10 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:Yadal3xhXoq7F1oOZPjy_hyn_UF-z72C0XjH89kz8fgNDmPciecwITdJMC2M7CBe6DzeGif
4x8
4x8
3x4 3x4
3x6
21 20 19 18 17 16 15
24
23 25
1 2 3 4 5 6 7 8 9 10 11 12 13
W2W1 W3 W3
B2
T1 T2
B1
BL1 BL2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-3-12,Edge], [4:0-1-12,Edge], [6:0-1-8,Edge], [7:0-1-8,Edge], [9:0-1-12,Edge], [12:0-3-12,Edge],[15:0-2-4,Edge], [21:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.44 Vert(LL)-0.45 17-18 >566 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.69 Vert(TL)-0.71 17-18 >362 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.82 Horiz(TL)0.11 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 85 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1170/0-3-8, (min. 0-1-8), 22=1164/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3284/0, 3-4=-3284/0, 4-5=-4913/0, 5-6=-4913/0, 6-7=-5120/0, 7-8=-4899/0, 8-9=-4899/0, 9-10=-3247/0,
10-11=-3247/0, 11-12=-3247/0
BOT CHORD 21-22=0/1872, 20-21=0/4285, 19-20=0/4285, 18-19=0/5120, 17-18=0/5120, 16-17=0/5120, 15-16=0/4260, 14-15=0/1824
WEBS 2-22=-2148/0, 12-14=-2114/0, 2-21=0/1637, 12-15=0/1649, 4-21=-1160/0, 9-15=-1174/0, 4-19=0/728, 9-16=0/741,
6-19=-662/214, 7-16=-673/203
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F14 8 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:52 Page: 1
ID:Yadal3xhXoq7F1oOZPjy_hyn_UF-z72C0XjH89kz8fgNDmPciecyYThbM9dM7CBe6DzeGif
3x6 FP
1.5x3 4x6
4x8
3x4 1.5x3
3x4
3x4
1.5x3 1.5x3
17 16 15 14 13
19 20
1 2 3 4 5 6 7 8 9 10 11
W2W1 W3 W3BL1 BL1
B2
T1 T2
B1
Scale = 1:32.2
Plate Offsets (X, Y): [2:0-2-12,Edge], [10:0-2-12,Edge], [14:0-1-8,Edge], [15:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.54 Vert(LL)-0.25 14-15 >839 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.92 Vert(TL)-0.39 14-15 >539 360
BCLL 0.0 Rep Stress Incr YES WB 0.61 Horiz(TL)0.08 12 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 70 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 14-15.
REACTIONS (lb/size)12=959/0-3-8, (min. 0-1-8), 18=959/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2578/0, 3-4=-2578/0, 4-5=-3482/0, 5-6=-3482/0, 6-7=-3482/0, 7-8=-2578/0, 8-9=-2578/0, 9-10=-2578/0
BOT CHORD 17-18=0/1511, 16-17=0/1511, 15-16=0/3222, 14-15=0/3482, 13-14=0/3222, 12-13=0/1511
WEBS 2-18=-1734/0, 10-12=-1734/0, 2-16=0/1237, 10-13=0/1237, 4-16=-746/0, 7-13=-746/0, 4-15=-51/592, 7-14=-51/592
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are 1.5x3 MT20 unless otherwise indicated.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F15 4 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:0mByyPyJH5y_tBNa77EBXuyn_UE-SJcbEtkvvTsqmpFZmTwrFs95jtzD5f7VMswBffzeGie
3x6 FP
3x4
3x6
1.5x3
3x4
6x6 3x4 4x8
21 20 1918 1716 15
2312345678910111213
W1 W2 W3 W3
B2
T1 T2
B1
BL1
Scale = 1:34.2
Plate Offsets (X, Y): [5:0-1-8,Edge], [8:0-1-8,Edge], [15:0-3-0,Edge], [20:0-3-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.50 Vert(LL)-0.32 17-18 >704 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.77 Vert(TL)-0.50 17-18 >449 360
BCLL 0.0 Rep Stress Incr YES WB 0.68 Horiz(TL)0.09 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 79 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat) *Except* B2:2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-8-3 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1032/0-3-8, (min. 0-1-8), 22=1038/ Mechanical, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2830/0, 3-4=-2830/0, 4-5=-4012/0, 5-6=-4012/0, 6-7=-4028/0, 7-8=-4012/0, 8-9=-4012/0, 9-10=-2830/0,
10-11=-2830/0, 11-12=-2830/0
BOT CHORD 21-22=0/1642, 20-21=0/1642, 19-20=0/3606, 18-19=0/4028, 17-18=0/4028, 16-17=0/4028, 15-16=0/3606, 14-15=0/1641
WEBS 2-22=-1889/0, 12-14=-1882/0, 2-20=0/1376, 12-15=0/1378, 4-20=-900/0, 9-15=-899/0, 4-19=0/580, 5-19=-331/224,
9-16=0/580, 8-16=-331/224, 6-19=-692/517, 7-16=-691/517, 6-18=-299/261, 7-17=-300/261
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F17 2 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:0mByyPyJH5y_tBNa77EBXuyn_UE-SJcbEtkvvTsqmpFZmTwrFs96Lt?a5e1VMswBffzeGie
4x8
4x8
3x4 3x4
3x6
21 20 19 18 17 16 15
23 24
1 2 3 4 5 6 7 8 9 10 11 12 13
W2W1 W3 W3BL1 BL1
B2
T1
B1
T2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-3-12,Edge], [4:0-1-12,Edge], [6:0-1-8,Edge], [7:0-1-8,Edge], [9:0-1-12,Edge], [12:0-3-12,Edge],[15:0-2-4,Edge], [21:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL)-0.42 17-18 >611 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.66 Vert(TL)-0.65 17-18 >391 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.81 Horiz(TL)0.11 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 86 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1167/0-3-8, (min. 0-1-8), 22=1167/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3296/0, 3-4=-3296/0, 4-5=-4936/0, 5-6=-4936/0, 6-7=-5146/0, 7-8=-4936/0, 8-9=-4936/0, 9-10=-3296/0,
10-11=-3296/0, 11-12=-3296/0
BOT CHORD 21-22=0/1876, 20-21=0/4300, 19-20=0/4300, 18-19=0/5146, 17-18=0/5146, 16-17=0/5146, 15-16=0/4300, 14-15=0/1876
WEBS 2-22=-2154/0, 12-14=-2154/0, 2-21=0/1645, 12-15=0/1645, 4-21=-1163/0, 9-15=-1163/0, 4-19=0/738, 9-16=0/738,
6-19=-666/214, 7-16=-666/214
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
F18 24 1REN0-046176 Floor Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:0mByyPyJH5y_tBNa77EBXuyn_UE-SJcbEtkvvTsqmpFZmTwrFs98Nt1H5c?VMswBffzeGie
3x6 FP
37 38
1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18
ST1W1 W1BL1BL1
B2
T1 T2
B1
Scale = 1:37.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.04 Horiz(TL)n/a -n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MR Weight: 72 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 21-7-1.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 19, 20, 21, 22, 23, 24,
25, 26, 27, 28, 29, 30, 32, 33, 34, 35, 36
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
FE01 4 1REN0-046176 Floor Supported Gable Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-SJcbEtkvvTsqmpFZmTwrFs9CwtBI5o2VMswBffzeGie
3x6 FP
19
38
37 39
1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18
ST1W1 W1
T1
B2B1
T2
BL1 BL2
Scale = 1:37.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.09 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.04 Horiz(TL)n/a -n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MR Weight: 72 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 21-7-0.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 19, 20, 21, 22, 23, 24,
25, 26, 27, 28, 29, 31, 32, 33, 34, 35, 36
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
FE02 2 1REN0-046176 Floor Supported Gable Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:VzkK9lzx2P4rUKymhqlQ36yn_UD-SJcbEtkvvTsqmpFZmTwrFs9CltBS5o2VMswBffzeGie
3x6 FP
MT18HS 3x10 FP
1.5x3 6x10
6x10
6x6
3x5
4x6
5x6
3x5 3x5 3x5
23
22 21 20 19 18 17 16
15
24 251234567891011121314
W2W1
B2B2B1 B1
W3 W3BL1 BL1
T2 T3T1 T4
W4
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-4-8,Edge], [3:0-3-0,Edge], [5:0-3-12,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [9:0-3-0,Edge], [12:0-3-0,Edge], [13:0-6-4,Edge], [14:Edge,0-1-8], [16:0-3-0,Edge],
[18:0-3-0,Edge], [19:0-3-0,Edge], [20:0-1-8,Edge], [22:0-4-8,Edge], [23:Edge,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.51 Vert(LL)-0.43 18-19 >588 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.70 Vert(TL)-0.68 18-19 >374 360 MT18HS 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.90 Horiz(TL)0.08 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 130 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF No.2(flat) *Except* W1:2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=2074/0-3-8, (min. 0-1-8), 23=1362/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4289/0, 3-4=-4289/0, 4-5=-4289/0, 5-6=-7012/0, 6-7=-7012/0, 7-8=-7012/0, 8-9=-7703/0, 9-10=-7703/0,
10-11=-6379/0, 11-12=-6379/0, 12-13=-6379/0
BOT CHORD 22-23=0/2361, 21-22=0/5809, 20-21=0/5809, 19-20=0/7012, 18-19=0/7651, 17-18=0/7296, 16-17=0/7296, 15-16=0/3704
WEBS 12-16=-1288/0, 2-23=-2667/0, 10-16=-1036/0, 2-22=0/2178, 10-18=0/460, 5-22=-1716/0, 8-18=-3/355, 5-20=0/1672,
8-19=-1112/0, 6-20=-586/0, 7-19=0/333, 13-15=-4184/0, 13-16=0/3173
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1182 lb down at 17-7-14 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-23=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 12=-1102
Job Truss Truss Type Qty Ply .
FG01 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:Nk_r?70S6ebGzyFYwgqMEyyn_U9-SJcbEtkvvTsqmpFZmTwrFs96Ct1g5acVMswBffzeGie
MT18HS 3x10 FP
3x6 FP
MT18HS 3x10 FP
1.5x3 6x10
5x6 5x6
6x6
5x6 6x10 1.5x3
26
25 24 23 22 21 20 19 18 17
16
27 28123456789101112131415
W1 W3
B2B2B1 B1
W4 W4BL1 BL1
T2 T3T1 T4
W2
2-3-11
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-3-0,Edge], [3:0-3-0,Edge], [5:0-3-0,Edge], [7:0-3-0,Edge], [9:0-3-0,Edge], [10:0-3-0,Edge], [11:0-3-0,Edge], [13:0-3-0,Edge], [15:Edge,0-1-8], [16:Edge,0-3-0],
[17:0-3-8,Edge], [19:0-1-8,Edge], [20:0-3-0,Edge], [21:0-3-0,Edge], [23:0-4-0,Edge], [25:0-3-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.45 Vert(LL)-0.40 22 >638 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.81 Vert(TL)-0.63 22 >405 360 MT18HS 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.98 Horiz(TL)0.09 16 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 133 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat) *Except* B2:2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF Stud(flat) *Except* W2:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)16=1266/0-3-7, (min. 0-1-8), 26=2058/0-3-8, (min. 0-1-8)
Max Grav 16=1266 (LC 1), 26=2060 (LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3765/0, 3-4=-6107/0, 4-5=-6107/0, 5-6=-6107/0, 6-7=-6633/0, 7-8=-6633/0, 8-9=-6432/0, 9-10=-6137/0,
10-11=-6137/0, 11-12=-3946/0, 12-13=-3946/0, 13-14=-3946/0
BOT CHORD 25-26=0/3765, 24-25=0/5169, 23-24=0/5169, 22-23=0/6587, 21-22=0/6432, 20-21=0/6432, 19-20=0/6432, 18-19=0/5254,
17-18=0/5254, 16-17=0/2195
WEBS 2-25=0/727, 2-26=-4228/0, 3-25=-1576/0, 14-16=-2479/0, 3-23=0/1059, 14-17=0/1979, 6-23=-543/0, 11-17=-1477/0,
6-22=-290/262, 7-22=-437/8, 11-19=0/1104, 10-19=-94/352, 8-22=-93/991, 9-19=-1238/0, 8-21=-498/0, 9-20=0/491
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 3x5 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
7)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1151 lb down at 2-3-11 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 16-26=-10, 1-15=-100
Concentrated Loads (lb)
Vert: 2=-991
Job Truss Truss Type Qty Ply .
FG02 4 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:53 Page: 1
ID:Nk_r?70S6ebGzyFYwgqMEyyn_U9-SJcbEtkvvTsqmpFZmTwrFs968t?x5ZLVMswBffzeGie
4x8
4x8
3x4 3x4
3x6
21 20 19 18 17 16 15
23 24
1 2 3 4 5 6 7 8 9 10 11 12 13
W2W1 W3 W3BL1 BL1
B2
T1
B1
T2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-3-12,Edge], [4:0-1-12,Edge], [6:0-1-8,Edge], [7:0-1-8,Edge], [9:0-1-12,Edge], [12:0-3-12,Edge],[15:0-2-4,Edge], [21:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL)-0.42 17-18 >611 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.66 Vert(TL)-0.65 17-18 >391 360 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.81 Horiz(TL)0.11 14 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 86 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1167/0-3-7, (min. 0-1-8), 22=1167/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3296/0, 3-4=-3296/0, 4-5=-4937/0, 5-6=-4937/0, 6-7=-5147/0, 7-8=-4937/0, 8-9=-4937/0, 9-10=-3296/0,
10-11=-3296/0, 11-12=-3296/0
BOT CHORD 21-22=0/1877, 20-21=0/4300, 19-20=0/4300, 18-19=0/5147, 17-18=0/5147, 16-17=0/5147, 15-16=0/4300, 14-15=0/1877
WEBS 2-22=-2154/0, 12-14=-2154/0, 2-21=0/1645, 12-15=0/1645, 4-21=-1163/0, 9-15=-1163/0, 4-19=0/738, 9-16=0/738,
6-19=-666/214, 7-16=-666/214
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
FG03 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:vYQTon?qLKTQLohLMyJ7hkyn_UA-wVAzRDlXgm_hNzqlKBS4o3hJ7HNWq2FebWgkB5zeGid
1.5x3 5x6
1.5x3
1.5x3
5x6
3x8
3x5
8
7 6
91 2 3 4
W1
T1T1
W2
B1
BL1
Scale = 1:26.4
Plate Offsets (X, Y): [2:0-1-8,Edge], [3:0-1-8,Edge], [4:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.13 Vert(LL)-0.03 6-7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.58 Vert(TL)-0.04 6-7 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.57 Horiz(TL)0.02 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 30 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-8-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=1149/ Mechanical, (min. 0-1-8), 8=1143/0-8-13, (min. 0-1-8)
Max Grav 5=1202 (LC 4), 8=1196 (LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1792/0
BOT CHORD 7-8=0/1792, 6-7=0/1792, 5-6=0/1792
WEBS 2-8=-2087/0, 3-5=-2088/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)929 lb down at 1-10-4, and 929 lb down at 3-10-4 on top chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 5-8=-10, 1-4=-100
Concentrated Loads (lb)
Vert: 2=-849, 3=-849
Job Truss Truss Type Qty Ply .
FG04 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:Nk_r?70S6ebGzyFYwgqMEyyn_U9-wVAzRDlXgm_hNzqlKBS4o3hMuHOnq60ebWgkB5zeGid
3x6 FP
3x6 FP 3x6 FP
1.5x3 6x10
5x6
4x6
4x6
3x5
5x6
3x5
5x6
3x5
23
22 21 20 19 18 17 16
15
24 251234567891011121314
W1 W2
B2B2B1 B1
W4 W4
T3T2 T4T1
W3 BL2BL1
3-11-3
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-4-4,Edge], [3:0-3-0,Edge], [6:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], [10:0-3-0,Edge], [12:0-3-0,Edge], [13:0-2-8,Edge], [14:Edge,0-1-8], [15:Edge,0-3-0],
[16:0-3-0,Edge], [18:0-1-8,Edge], [19:0-3-0,Edge], [20:0-3-0,Edge], [22:0-5-12,Edge], [23:Edge,0-2-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.42 Vert(LL)-0.32 19-20 >806 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.89 Vert(TL)-0.50 19-20 >515 360
BCLL 0.0 Rep Stress Incr NO WB 0.81 Horiz(TL)0.07 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 261 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat) *Except* W3:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=1527/0-3-8, (min. 0-1-8), 23=2802/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-8992/0, 3-4=-8992/0, 4-5=-8992/0, 5-6=-9726/0, 6-7=-9726/0, 7-8=-8320/0, 8-9=-8320/0, 9-10=-8320/0,
10-11=-4915/0, 11-12=-4915/0, 12-13=-4915/0
BOT CHORD 22-23=0/5205, 21-22=0/9620, 20-21=0/9620, 19-20=0/9338, 18-19=0/8320, 17-18=0/6731, 16-17=0/6731, 15-16=0/2665
WEBS 3-22=-2193/0, 5-22=-704/0, 13-15=-3010/0, 13-16=0/2541, 12-16=-251/0, 7-20=0/726, 10-16=-2052/0, 7-19=-1564/0,
10-18=0/2133, 8-19=0/531, 9-18=-792/0, 2-23=-5835/0, 2-22=0/4505
NOTES
1)Fasten trusses together to act as a single unit as per standard industry detail, or loads are to be evenly applied to all plies.
2)Unbalanced floor live loads have been considered for this design.
3)Bearing at joint(s) 23 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
7)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)2075 lb down at 3-11-3 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-23=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 3=-1995
Job Truss Truss Type Qty Ply .
FG05 2 2REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:Nk_r?70S6ebGzyFYwgqMEyyn_U9-wVAzRDlXgm_hNzqlKBS4o3hIMHKxq2FebWgkB5zeGid
1.5x3 5x6
1.5x3
1.5x3
5x6
3x10
3x5
8
7 6
91 10 2 3 4
W1
T1T1
W2
B1
BL1
Scale = 1:26.4
Plate Offsets (X, Y): [2:0-1-8,Edge], [3:0-1-8,Edge], [4:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.58 Vert(LL)-0.04 7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.68 Vert(TL)-0.06 7 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.62 Horiz(TL)0.02 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 33 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=2001/ Mechanical, (min. 0-1-8), 8=1239/1-0-3, (min. 0-1-8)
Max Grav 5=2095 (LC 4), 8=1293 (LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-262/0, 1-9=-262/0, 4-5=-1062/0, 2-3=-1945/0
BOT CHORD 7-8=0/1945, 6-7=0/1945, 5-6=0/1945
WEBS 2-8=-2186/0, 3-5=-2196/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)930 lb down at 1-10-4, and 930 lb down at 3-10-4, and 937 lb down at
6-1-11 on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 5-8=-10, 1-4=-100
Concentrated Loads (lb)
Vert: 4=-885, 3=-850, 10=-850
Job Truss Truss Type Qty Ply .
FG06 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:Nk_r?70S6ebGzyFYwgqMEyyn_U9-wVAzRDlXgm_hNzqlKBS4o3hFsHNCq5DebWgkB5zeGid
3x6 FP
37 38
1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18
ST1W1 W1BL1BL1
B2
T1 T2
B1
Scale = 1:37.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.04 Horiz(TL)n/a -n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MR Weight: 72 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 21-7-1.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 19, 20, 21, 22, 23, 24,
25, 26, 27, 28, 29, 30, 32, 33, 34, 35, 36
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply .
FG07 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:Nk_r?70S6ebGzyFYwgqMEyyn_U9-wVAzRDlXgm_hNzqlKBS4o3hNgHXXqEIebWgkB5zeGid
3x6 FP
MT18HS 3x10 FP
1.5x3 MT18HS 6x12
5x8
5x6
4x6
3x5
3x5
5x6
3x5 3x5
5x8
3x5
24
23 22 21 20 19 18 17 16
15
25 261234567891011121314
W2W1
B2B2
T2 T2
B1 B1
T1T1
W3 W3BL1 BL1
Scale = 1:37.8
Plate Offsets (X, Y): [3:0-3-0,Edge], [5:0-3-0,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], [10:0-3-0,Edge], [12:0-3-0,Edge], [14:Edge,0-1-8], [15:Edge,0-3-0],
[16:0-3-8,Edge], [18:0-1-12,Edge], [19:0-3-0,Edge], [20:0-3-0,Edge], [21:0-3-0,Edge], [23:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.40 Vert(LL)-0.39 20 >646 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.94 Vert(TL)-0.62 20 >414 360 MT18HS 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.74 Horiz(TL)0.09 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 131 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat) *Except* B2:2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF Stud(flat) *Except* W2:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=1270/0-3-8, (min. 0-1-8), 24=2131/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5192/0, 3-4=-5192/0, 4-5=-5192/0, 5-6=-6636/0, 6-7=-6636/0, 7-8=-6639/0, 8-9=-6161/0, 9-10=-6161/0,
10-11=-3967/0, 11-12=-3967/0, 12-13=-3967/0
BOT CHORD 23-24=0/3800, 22-23=0/6115, 21-22=0/6115, 20-21=0/6639, 19-20=0/6639, 18-19=0/6639, 17-18=0/5281, 16-17=0/5281,
15-16=0/2206
WEBS 2-24=-4292/0, 13-15=-2492/0, 2-23=0/1573, 13-16=0/1989, 5-23=-1043/0, 10-16=-1484/0, 5-21=0/588, 6-21=-277/0,
10-18=0/994, 7-21=-369/546, 8-18=-1036/0, 8-19=-41/252
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 3x5 MT20 unless otherwise indicated.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1228 lb down at 2-3-11 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-24=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 2=-1068
Job Truss Truss Type Qty Ply .
FG08 4 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:z9IjN5_ZpjCi6UXzFXHfcJyn_UC-wVAzRDlXgm_hNzqlKBS4o3hIfHJ9q3LebWgkB5zeGid
3x6 FP
MT18HS 3x10 FP
1.5x3 6x10
6x10
5x6
4x6
3x5
3x5
5x6
3x5 3x5
5x8
3x5
24
23 22 21 20 19 18 17 16
15
25 261234275286782993010111231133214
W2W1
B2B2
T2 T2
B1 B1
T1T1
W3 W3BL1 BL1
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-4-8,Edge], [3:0-3-0,Edge], [5:0-3-0,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], [10:0-3-0,Edge], [12:0-3-0,Edge], [13:0-4-12,Edge],
[14:Edge,0-1-8], [15:Edge,0-3-0], [16:0-3-4,Edge], [18:0-1-12,Edge], [19:0-3-0,Edge], [20:0-3-0,Edge], [21:0-2-12,Edge], [23:0-4-8,Edge], [24:Edge,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 0.90 TC 0.46 Vert(LL)-0.32 19-20 >793 240 MT20 197/144
TCDL 10.0 Plate Metal DOL 0.90 BC 0.89 Vert(TL)-0.67 19-20 >382 180 MT18HS 197/144
BCLL 0.0 Lumber DOL 0.90 WB 0.63 Horiz(TL)0.09 15 n/a n/a
BCDL 5.0 Rep Stress Incr NO Matrix-MS
Code IBC2012/TPI2007 Weight: 262 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat) *Except* B2:2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF Stud(flat) *Except* W2:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=2514/0-3-8, (min. 0-1-8), 24=2399/0-3-8, (min. 0-1-8)
Max Uplift 15=-420 (LC 6), 24=-388 (LC 6)
Max Grav 15=2814 (LC 4), 24=2717 (LC 4)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-8877/1364, 3-4=-8877/1364, 4-27=-8877/1364, 5-27=-8877/1364, 5-28=-13389/2065, 6-28=-13389/2065,
6-7=-13389/2065, 7-8=-13975/2156, 8-29=-13360/2055, 9-29=-13360/2055, 9-30=-13360/2055, 10-30=-13360/2055,
10-11=-8798/1338, 11-12=-8798/1338, 12-31=-8798/1338, 13-31=-8798/1338
BOT CHORD 23-24=-765/4952, 22-23=-1818/11699, 21-22=-1818/11699, 20-21=-2156/13975, 19-20=-2156/13975,
18-19=-2156/13975, 17-18=-1808/11666, 16-17=-1808/11666, 15-16=-780/4998
WEBS 2-24=-5593/864, 13-15=-5645/881, 2-23=-676/4434, 3-23=-543/106, 13-16=-630/4293, 12-16=-453/76, 5-23=-3187/514,
10-16=-3239/531, 5-21=-278/1909, 6-21=-499/84, 10-18=-280/1914, 9-18=-492/82, 7-21=-1023/112, 8-18=-1058/123
NOTES
1)Fasten trusses together to act as a single unit as per standard industry detail, or loads are to be evenly applied to all plies.
2)Unbalanced floor live loads have been considered for this design.
3)This truss is not designed to be used as a floor truss.
4)All plates are MT20 plates unless otherwise indicated.
5)All plates are 3x5 MT20 unless otherwise indicated.
6)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 24 and 420 lb uplift at joint 15.
7)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
9)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)428 lb down and 119 lb up at 2-0-12, 428 lb down and 119 lb up at 4-0-12,
428 lb down and 119 lb up at 6-0-12, 428 lb down and 119 lb up at 8-0-12, 428 lb down and 119 lb up at 10-0-12, 428 lb down and 119 lb up at 12-0-12, 428 lb down and 119
lb up at 14-0-12, 428 lb down and 119 lb up at 16-0-12, and 428 lb down and 119 lb up at 18-0-12,and 428 lb down and 119 lb up at 20-0-12 on top chord. The design/
selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Snow (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 15-24=-10, 1-14=-20
Concentrated Loads (lb)
Vert: 11=-428, 2=-428, 3=-428, 7=-428, 27=-428, 28=-428, 29=-428, 30=-428, 31=-428, 32=-428
Job Truss Truss Type Qty Ply .
FG09 2 2REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:54 Page: 1
ID:z9IjN5_ZpjCi6UXzFXHfcJyn_UC-wVAzRDlXgm_hNzqlKBS4o3hHjHKxq54ebWgkB5zeGid
3x6 FP
19
38
37 39
1 2 40 3 4 5 41 6 7 8 42 9 10 11 43 12 1314 15 44 16 17 18
ST1W1 W1
T1
B2B1
T2
BL1 BL2
Scale = 1:37.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 0.90 TC 0.45 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Plate Metal DOL 0.90 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Lumber DOL 0.90 WB 0.09 Horiz(TL)n/a -n/a n/a
BCDL 5.0 Rep Stress Incr NO Matrix-MR
Code IBC2012/TPI2007 Weight: 72 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 21-7-0.
(lb) -Max Uplift All uplift 100 (lb) or less at joint(s) 20, 21, 22, 23, 24, 25, 26,
27, 28, 29, 31, 32, 33, 34, 35, 36
Max Grav All reactions 250 (lb) or less at joint(s) 19 except 20=362 (LC
4), 21=294 (LC 4), 22=276 (LC 4), 23=322 (LC 4), 24=304 (LC
4), 25=273 (LC 4), 26=323 (LC 4), 27=304 (LC 4), 28=273 (LC
4), 29=323 (LC 4), 31=304 (LC 4), 32=273 (LC 4), 33=322 (LC
4), 34=304 (LC 4), 35=272 (LC 4), 36=304 (LC 1)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 36-37=-301/72, 1-37=-301/73
WEBS 2-35=-256/39, 3-34=-291/50, 4-33=-308/57, 5-32=-259/39, 6-31=-290/50, 7-29=-309/57, 8-28=-259/39, 9-27=-290/50,
10-26=-309/57, 11-25=-259/39, 12-24=-290/50, 14-23=-308/57, 15-22=-262/40, 16-21=-280/48, 17-20=-348/67
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are 1.5x3 MT20 unless otherwise indicated.
3)Gable requires continuous bottom chord bearing.
4)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
5)Gable studs spaced at 1-4-0 oc.
6)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 36, 35,34, 33, 32, 31, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20.
7)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
9)CAUTION, Do not erect truss backwards.
10)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)329 lb down and 90 lb up at 0-2-4, 318 lb down and 97 lb up at 2-0-12,
318 lb down and 97 lb up at 4-0-12, 318 lb down and 97 lb up at 6-0-12, 318 lb down and 97 lb up at 8-0-12, 318 lb down and 97 lb up at 10-0-12, 318 lb down and 97 lb up
at 12-0-12, 318 lb down and 97 lb up at 14-0-12, 318 lb down and 97 lb up at 16-0-12, and 318 lb down and 97 lb up at 18-0-12, and 318 lb down and 97 lb up at 20-0-12
on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Snow (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 19-36=-10, 1-18=-20
Concentrated Loads (lb)
Vert: 1=-329, 4=-318, 7=-318, 10=-318, 14=-318, 17=-318, 40=-318, 41=-318, 42=-318, 43=-318, 44=-318
Job Truss Truss Type Qty Ply .
FG10 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:55 Page: 1
ID:RLs5aR_Ca0KZke69oFou8Xyn_UB-OikLfZmAR46Y?7PxuuzJKHESegtmZglopAPIjXzeGic
3x5
3x5
3x5
3x5
3x5
1 2 3
W1
T1T1
W2
B1
Scale = 1:21.4
Plate Offsets (X, Y): [1:Edge,0-1-8], [2:0-3-0,Edge], [3:Edge,0-1-8], [4:0-2-0,Edge], [5:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.05 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.18 Vert(TL)-0.01 4-5 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.19 Horiz(TL)0.00 4 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MP Weight: 16 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-6-2 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)4=596/ Mechanical, (min. 0-1-8), 5=596/ Mechanical, (min.
0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOT CHORD 4-5=0/504
WEBS 2-5=-718/0, 2-4=-718/0
NOTES
1)Refer to girder(s) for truss to truss connections.
2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
4)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)944 lb down at 1-5-14 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 4-5=-10, 1-3=-100
Concentrated Loads (lb)
Vert: 2=-944
Job Truss Truss Type Qty Ply .
FG11 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:55 Page: 1
ID:VzkK9lzx2P4rUKymhqlQ36yn_UD-OikLfZmAR46Y?7PxuuzJKHEZtgrFZfCopAPIjXzeGic
3x5
3x8
5x6
1.5x3
1.5x3
5x6
3x8
3x5
7 6
5
91102113124
W1
T1T1
W2
B1
BL1
Scale = 1:25.6
Plate Offsets (X, Y): [1:Edge,0-1-8], [2:0-1-8,Edge], [3:0-1-8,Edge], [4:0-3-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.63 Vert(LL)-0.03 6-7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.51 Vert(TL)-0.04 6-7 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.54 Horiz(TL)0.02 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 30 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-6-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=1657/0-3-8, (min. 0-1-8), 8=1505/ Mechanical, (min. 0-1-8)
Max Grav 5=1737 (LC 4), 8=1584 (LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-8=-516/0, 5-9=-699/0, 4-9=-698/0, 2-11=-1686/0, 3-11=-1686/0
BOT CHORD 7-8=0/1686, 6-7=0/1686, 5-6=0/1686
WEBS 2-8=-1986/0, 3-5=-1947/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)931 lb down at 0-11-2, and 929 lb down at 2-11-2, and 935 lb down at
4-11-2 on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 5-8=-10, 1-4=-100
Concentrated Loads (lb)
Vert: 10=-859, 11=-849, 12=-877
Job Truss Truss Type Qty Ply .
FG12 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:55 Page: 1
ID:hhnIf8_eh4mRZrH5a47GBAymxPx-OikLfZmAR46Y?7PxuuzJKHEQqgm6ZZjopAPIjXzeGic
1.5x3 4x6
1.5x3
1.5x3
4x6
3x6
3x5
8
7 6
91 2 10 3 11 4
W1
T1T1
W2
B1
BL1
Scale = 1:28.4
Plate Offsets (X, Y): [2:0-3-0,Edge], [3:0-3-0,Edge], [4:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL)-0.01 6-7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.30 Vert(TL)-0.02 6-7 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.34 Horiz(TL)0.01 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 25 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-5-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=1351/ Mechanical, (min. 0-1-8), 8=830/0-8-11, (min. 0-1-8)
Max Grav 5=1421 (LC 4), 8=869 (LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-538/0, 2-10=-987/0, 3-10=-987/0
BOT CHORD 7-8=0/987, 6-7=0/987, 5-6=0/987
WEBS 2-8=-1321/0, 3-5=-1315/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)929 lb down at 1-10-4, and 934 lb down at 3-10-4 on top chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 5-8=-10, 1-4=-100
Concentrated Loads (lb)
Vert: 10=-849, 11=-874
Job Truss Truss Type Qty Ply .
FG13 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:55 Page: 1
ID:hhnIf8_eh4mRZrH5a47GBAymxPx-OikLfZmAR46Y?7PxuuzJKHETagpNZcropAPIjXzeGic
3x6 FP
MT18HS 3x10 FP
1.5x3 6x10
6x10
6x8
3x5
4x6
5x6
3x5 3x5 3x5
23
22 21 20 19 18 17 16
15
24 251234567891011121314
W1 W2
B2B2B1 B1
W5W5W3W3W4W4BL1 BL1
T2 T3T1 T4
3-11-3
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-4-4,Edge], [3:0-3-0,Edge], [5:0-3-4,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], [12:0-3-0,Edge], [14:0-3-0,Edge], [15:Edge,0-3-0],
[16:0-4-4,Edge], [18:0-3-0,Edge], [19:0-3-0,Edge], [20:0-1-8,Edge], [22:0-4-4,Edge], [23:Edge,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.42 Vert(LL)-0.44 18-19 >581 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.72 Vert(TL)-0.69 18-19 >371 360 MT18HS 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.93 Horiz(TL)0.10 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 135 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat) *Except* B2:2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat) *Except* W2,W5:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=2381/0-3-8, (min. 0-1-8), 23=1436/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4577/0, 3-4=-4577/0, 4-5=-4577/0, 5-6=-7604/0, 6-7=-7604/0, 7-8=-7604/0, 8-9=-8610/0, 9-10=-8610/0,
10-11=-7577/0, 11-12=-7577/0, 12-13=-7577/0
BOT CHORD 22-23=0/2497, 21-22=0/6219, 20-21=0/6219, 19-20=0/7604, 18-19=0/8408, 17-18=0/8333, 16-17=0/8333, 15-16=0/4425
WEBS 12-16=-1676/0, 2-23=-2820/0, 10-16=-854/0, 2-22=0/2350, 10-18=0/313, 5-22=-1855/0, 8-18=0/519, 5-20=0/1885,
8-19=-1309/0, 6-20=-692/0, 7-19=0/430, 13-15=-4960/0, 13-16=0/3743
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1564 lb down at 17-7-13 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-23=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 12=-1484
Job Truss Truss Type Qty Ply .
FG14 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:55 Page: 1
ID:9tLgsU?GSOuIB?sH8neVkOymxPw-OikLfZmAR46Y?7PxuuzJKHET6gipZTdopAPIjXzeGic
3x6 FP
MT18HS 3x10 FP
1.5x3 6x10
6x10
6x6
3x5
4x6
5x6
3x5 3x5 3x5
23
22 21 20 19 18 17 16
15
24 251234567891011121314
W1 W2
B2B2B1 B1
W5W5W3W3W4W4BL1 BL1
T2 T3T1 T4
3-11-3
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-4-4,Edge], [3:0-3-0,Edge], [5:0-3-8,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [9:0-3-0,Edge], [12:0-3-0,Edge], [14:0-3-0,Edge], [15:Edge,0-3-0], [16:0-4-8,Edge],
[18:0-3-0,Edge], [19:0-3-0,Edge], [20:0-1-8,Edge], [22:0-4-4,Edge], [23:Edge,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.40 Vert(LL)-0.42 18-19 >609 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.66 Vert(TL)-0.65 18-19 >390 360 MT18HS 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.89 Horiz(TL)0.09 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 135 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat) *Except* W2,W5:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=2248/0-3-8, (min. 0-1-8), 23=1407/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4463/0, 3-4=-4463/0, 4-5=-4463/0, 5-6=-7372/0, 6-7=-7372/0, 7-8=-7372/0, 8-9=-8254/0, 9-10=-8254/0,
10-11=-7114/0, 11-12=-7114/0, 12-13=-7114/0
BOT CHORD 22-23=0/2443, 21-22=0/6054, 20-21=0/6054, 19-20=0/7372, 18-19=0/8108, 17-18=0/7922, 16-17=0/7922, 15-16=0/4167
WEBS 12-16=-1517/0, 2-23=-2759/0, 10-16=-913/0, 2-22=0/2282, 10-18=0/375, 5-22=-1797/0, 8-18=0/456, 5-20=0/1805,
8-19=-1230/0, 6-20=-661/0, 7-19=0/401, 13-15=-4671/0, 13-16=0/3499
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1401 lb down at 17-7-13 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-23=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 12=-1321
Job Truss Truss Type Qty Ply .
FG15 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:55 Page: 1
ID:9tLgsU?GSOuIB?sH8neVkOymxPw-OikLfZmAR46Y?7PxuuzJKHETPgjlZUGopAPIjXzeGic
3x6 FP
MT18HS 3x10 FP
1.5x3 MT18HS 8x12
MT18HS 8x12
5x6
4x6
4x6
3x5
6x6
3x5 3x5
23
22 21 20 19 18 17 16
15
24 251234567891011121314
W2W1
B2B2B1 B1
W4 W4
T3T2 T4T1
W3BL1 BL2
3-11-2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-5-0,Edge], [3:0-3-0,Edge], [6:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], [10:0-3-0,Edge], [12:0-3-0,Edge], [13:0-4-12,Edge], [14:0-3-0,Edge], [15:Edge,0-3-0],
[16:0-3-4,Edge], [18:0-1-8,Edge], [19:0-3-0,Edge], [20:0-3-0,Edge], [22:0-5-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.42 Vert(LL)-0.43 19-20 >597 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.62 Vert(TL)-0.67 19-20 >381 360 MT18HS 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.85 Horiz(TL)0.09 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 130 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat) *Except* B2:2x4 SPF 2100F 1.8E(flat)
WEBS 2x4 SPF Stud(flat) *Except* W2,W3:2x4 SPF No.2(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=1338/0-3-8, (min. 0-1-8), 23=1986/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6060/0, 3-4=-6060/0, 4-5=-6060/0, 5-6=-7475/0, 6-7=-7475/0, 7-8=-6895/0, 8-9=-6895/0, 9-10=-6895/0,
10-11=-4278/0, 11-12=-4278/0, 12-13=-4278/0
BOT CHORD 22-23=0/3539, 21-22=0/7015, 20-21=0/7015, 19-20=0/7475, 18-19=0/6895, 17-18=0/5747, 16-17=0/5747, 15-16=0/2390
WEBS 3-22=-1185/0, 2-23=-3997/0, 2-22=0/3001, 5-22=-1079/0, 13-15=-2676/0, 5-20=0/519, 13-16=0/2133, 7-20=-58/301,
10-16=-1659/0, 7-19=-1045/0, 10-18=0/1607, 8-19=0/307, 9-18=-560/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
7)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1070 lb down at 3-11-2 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-23=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 3=-990
Job Truss Truss Type Qty Ply .
FG16 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:56 Page: 1
ID:9tLgsU?GSOuIB?sH8neVkOymxPw-suIjsvmoCOEPdH_8ScUYtUmds44cIx7x2q9rF_zeGib
1.5x3 4x6
1.5x3
1.5x3
4x6
3x8
3x5
8
7 6
91 10 2 11 3 4
W1
T1T1
W2
B1
BL1
Scale = 1:26.4
Plate Offsets (X, Y): [2:0-3-0,Edge], [3:0-3-0,Edge], [4:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.63 Vert(LL)-0.03 7 >999 480 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.54 Vert(TL)-0.05 7 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.48 Horiz(TL)0.01 5 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 30 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-6-7 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=1808/ Mechanical, (min. 0-1-8), 8=1335/0-3-8, (min. 0-1-8)
Max Grav 5=1894 (LC 4), 8=1407 (LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-459/0, 1-9=-458/0, 4-5=-950/0, 2-11=-1502/0, 3-11=-1502/0
BOT CHORD 7-8=0/1502, 6-7=0/1502, 5-6=0/1502
WEBS 2-8=-1748/0, 3-5=-1772/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
6)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)924 lb down at 1-1-8, and 923 lb down at 3-1-8,and 930 lb down at
5-4-15 on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 5-8=-10, 1-4=-100
Concentrated Loads (lb)
Vert: 4=-879, 10=-846, 11=-843
Job Truss Truss Type Qty Ply .
FG17 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:56 Page: 1
ID:hhnIf8_eh4mRZrH5a47GBAymxPx-suIjsvmoCOEPdH_8ScUYtUmaa45sI1wx2q9rF_zeGib
3x6 FP
MT18HS 3x10 FP
1.5x3 MT18HS 8x12
8x10
5x6
5x6
4x6
3x5
6x8
3x5 3x5
23
22 21 20 19 18 17 16
15
24 251234567891011121314
W1 W4
B2B2B1 B1
W2W2 W5 W5W3W3
T3T2 T4T1
BL1 BL2
3-11-2
Scale = 1:37.8
Plate Offsets (X, Y): [2:0-5-12,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], [10:0-3-0,Edge], [12:0-3-0,Edge], [14:0-3-0,Edge], [15:Edge,0-3-0], [16:0-4-8,Edge],
[18:0-1-8,Edge], [19:0-3-0,Edge], [20:0-3-0,Edge], [22:0-3-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.45 Vert(LL)-0.45 19-20 >567 480 MT18HS 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.64 Vert(TL)-0.71 19-20 >362 360 MT20 197/144
BCLL 0.0 Rep Stress Incr NO WB 1.00 Horiz(TL)0.09 15 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MS Weight: 145 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E(flat)
BOT CHORD 2x4 SPF 2100F 1.8E(flat) *Except* B2:2x4 SP 2400F 2.0E(flat)
WEBS 2x4 SPF No.2(flat) *Except* W1,W5:2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)15=1487/0-3-8, (min. 0-1-8), 23=2642/0-3-8, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-8442/0, 3-4=-8442/0, 4-5=-8442/0, 5-6=-9308/0, 6-7=-9308/0, 7-8=-8094/0, 8-9=-8094/0, 9-10=-8094/0,
10-11=-4843/0, 11-12=-4843/0, 12-13=-4843/0
BOT CHORD 22-23=0/4929, 21-22=0/9132, 20-21=0/9132, 19-20=0/9016, 18-19=0/8094, 17-18=0/6600, 16-17=0/6600, 15-16=0/2671
WEBS 3-22=-1969/0, 5-22=-780/0, 13-15=-2992/0, 13-16=0/2453, 7-20=0/628, 10-16=-1984/0, 7-19=-1449/0, 10-18=0/2014,
8-19=0/456, 9-18=-710/0, 2-23=-5526/0, 2-22=0/4182
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
7)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1874 lb down at 3-11-2 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-23=-10, 1-14=-100
Concentrated Loads (lb)
Vert: 3=-1794
Job Truss Truss Type Qty Ply .
FG18 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:56 Page: 1
ID:d4v24p0vDi09o9RTiV9kHbymxPv-suIjsvmoCOEPdH_8ScUYtUmcO44JIvnx2q9rF_zeGib
3x5
3x5
3x5
3x5
3x5
4
6
1 2 3
W1
T1T1
W2
B1
BL1
Scale = 1:22.1
Plate Offsets (X, Y): [1:Edge,0-1-8], [2:0-3-0,Edge], [3:0-3-0,Edge], [4:0-2-0,Edge], [5:0-2-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.12 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 10.0 Lumber DOL 1.00 BC 0.07 Vert(TL)-0.01 4-5 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.04 Horiz(TL)0.00 4 n/a n/a
BCDL 5.0 Code IBC2012/TPI2007 Matrix-MP Weight: 17 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF Stud(flat)
OTHERS 2x4 SPF Stud(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-9-5 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)4=991/0-3-10, (min. 0-1-8), 5=1043/ Mechanical, (min. 0-1-8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-5=-929/0, 4-6=-924/0, 3-6=-923/0
NOTES
1)Refer to girder(s) for truss to truss connections.
2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
5)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)882 lb down at 0-1-8, and 880 lb down at 2-7-1 on top chord. The design/
selection of such connection device(s) is the responsibility of others.
LOAD CASE(S)Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 4-5=-10, 1-3=-100
Concentrated Loads (lb)
Vert: 3=-880, 1=-882
Job Truss Truss Type Qty Ply .
FG19 2 1REN0-046176 Floor Girder Job Reference (optional)
Stark Truss Company Inc., Rensselaer IN 47978, user Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Mar 04 15:40:56 Page: 1
ID:hhnIf8_eh4mRZrH5a47GBAymxPx-suIjsvmoCOEPdH_8ScUYtUmiY4CCI8ox2q9rF_zeGib