HomeMy WebLinkAboutHouse Permit Pack #8618SHEET INDEX PV1 - COVER SHEET PV2 - PROPERTY PLAN PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTES PV7 - MAIN BREAKER DERATE CALCS. (IF NEEDED) PV8 - LABELS & LOCATIONS PV9 - CUSTOM DIRECTORY PLACARD (IF NEEDED - NEC 690.56(B)) UTILITY COMPANY: Duke Energy IN PERMIT ISSUER: City of Carmel GENERAL NOTES SITE SPECIFICATIONS CONSTRUCTION - V-B ZONING: RESIDENTIAL SCOPE OF WORK INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM 6.375 kW DC PHOTOVOLTAIC SOLAR ARRAY ROOF TYPE: Comp Shingle MODULES: (17) JinKO Solar Eagle JKM375M-6RL3-B INVERTER(S): Enphase Energy IQ7PLUS-72-2-US,---- RACKING: Unirac SFM Infinity AERIAL VIEW SITE NOTES / OSHA REGULATION 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. 5. NO. OF SHINGLE LAYERS : 1 SOLAR CONTRACTOR 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM. 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, DC COMBINERS, DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (B). 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. EQUIPMENT LOCATIONS 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]. 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY [NEC 690.31 (A)] AND [NEC TABLE 310.15 (B)]. 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT TO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. PV1 COVER SHEET ENPHASE ENERGY 360621 June 16, 2021 0SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CODES AND STANDARDS 1. ALL WORK SHALL COMPLY WITH 2009 Indiana Electric Code, 2012 INTERNATIONAL BUILDING CODE (IBC), 2018 INTERNATIONAL RESIDENTIAL CODE (IRC), 2006 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES. 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. DESIGN CRITERIA WIND SPEED: 115 MPH GROUND SNOW LOAD: 20 PSF WIND EXPOSURE FACTOR: C SEISMIC DESIGN CATEGORY: C Sealed For Existing Roof & Attachment Only 6/16/2021 Digitally signed by John A. Calvert Date: 2021.06.16 15:30:27 -06'00' 10/21/21 N DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC 21' SCALE: 3/64" = 1'-0" 0' 42' 128'64' LEGEND AC M INVERTER & DC DISCONNECTINV AC DISCONNECT UTILITY METER PV REVENUE METER JB JUNCTION BOX PROPERTY LINE FIRE SETBACK EMT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV WIRE STRING PV SUB (E) SUBPANEL LC (N) LOAD CENTER C COMBINER BOX/AGGREGATOR MSP MAIN SERVICE PANEL TS TRANSFER SWITCH DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. PV2 PROPERTY PLAN 0 ENPHASE ENERGY 360621 June 16, 2021SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM FRONT OF HOME11095 Huntington CtSealed For Existing Roof & Attachment Only 6/16/2021 10/21/21 N DC AC DCAC DCAC DCAC DCAC DCAC DC AC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DC AC DCAC DC AC 4' 8' SCALE: 1/8" = 1'-0" 0' 2' 16' LEGEND AC M INVERTER & DC DISCONNECTINV AC DISCONNECT UTILITY METER PV REVENUE METER JB JUNCTION BOX PROPERTY LINE FIRE SETBACK EMT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV WIRE STRING PV SUB (E) SUBPANEL LC (N) LOAD CENTER C COMBINER BOX/AGGREGATOR MSP MAIN SERVICE PANEL TS TRANSFER SWITCH DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. ENPHASE ENERGY 360621 June 16, 2021SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED PV3 SITE PLAN 0 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM FRONT OF HOMEMP1 # OF MODULES: 17 AZIMUTH:170° PITCH:40° TSRF:91% AREA: 918 SQ. FT UNDERGROUND SERVICE LINE SKYLIGHT SKYLIGHT SKYLIGHT CHIMNEY 3' 3' 1'-6" DC ARRAY SIZE- 6.375 kWDC NUMBER OF MODULE- 17 TYPE OF MODULE- JinKO Solar JinKO Solar Eagle JKM375M-6RL3-B INVERTER TYPE- Enphase Energy IQ7PLUS-72-2-US Sealed For Existing Roof & Attachment Only 6/16/2021 10/21/21 MODULE WIDTH H PV4 ARRAY DETAIL, FRONT VIEW Scale: 3/8" = 1'-0" MODULE WIDTH 1'-11" MAX. 40 ° 48" MAX.1'-11" MAX. ARRAY DETAIL, SIDE VIEW Scale: 3/8" = 1'-0" LANDSCAPE PORTRAIT LANDSCAPE PORTRAIT Unirac SFM Infinity TRIM RAILPV MODULE (BEHIND TRIM RAIL) G PV4 Unirac SFM Infinity FRAME SFM Infinity Switchblade Flashkit 64" MAX. RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER. (E) ROOF MEMBRANE UNIRAC SLIDERS AND TRIMRAIL ROOF ATTACHMENTS PV MODULE (E) BUILDING STRUCTUREDETAIL, BOTTOM STANDOFFScale: 3" = 1'-0"GJinKO Solar Eagle JKM375M-6RL3-B 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" Unirac SFM Infinity UNIRAC TRIMRAIL 2.5" MIN. EMBED.FLASHING (E) ROOF MEMBRANE UNIRAC SLIDERS PV MODULE (E) BUILDING STRUCTURE JinKO Solar Eagle JKM375M-6RL3-B 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" Unirac SFM Infinity FLASHING DETAIL, MIDDLE/TOP STANDOFFScale: 3" = 1'-0"H2.5" MIN. EMBED. ROOF TYPE: Comp Shingle ROOF FRAMING TYPE: Rafter RAFTER OR TOP CHORD(TRUSS) 2x6 @ 16"O.C. CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x10 @ 16"O.C. PV ARRAY INFORMATION PV MODULE COUNT: 17 MODULES # OF ATTACHMENT POINTS¹: 38 ARRAY AREA: Module Count x 17.51ft² = 297.7ft² ROOF AREA: 3902.0ft² % OF ARRAY/ROOF: 7.6% ARRAY WEIGHT: Module Count x 50lbs = 850.0lbs DISTRIBUTED LOAD: Array Weight ÷ Array Area = 2.86 lbs/ft² POINT LOAD: Array Weight ÷ Attachments = 22.4lbs/attachment DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. ENPHASE ENERGY 360621 June 16, 2021SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED PV4 EQUIP. DETAIL 0 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM ---- 1 - Number of attachment points estimated and may vary based on on-site conditions as long as maximum attachment spacing followed per engineered plans. Sealed For Existing Roof & Attachment Only 6/16/2021 10/21/21 (E)LOADS N G (E)200A / 2P N EGC L2 L1 (N)30A/2P (E)200A MAIN SERVICE PANEL (E)200A / 2P MAIN BREAKER N EGC L2 L1 15 (E) GROUNDING ELECTRODE (S) INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER PV AC DISCONNECT NON- FUSED LOCKABLE, VISIBLE OPEN 30A, 240V, 2-POLE 120/240 VAC 60HZ 1 PHASE TO UTILITY GRID (E) L1 N L2 N G G L2 L1 (N)20A/2P 2 1 L1 L2 G 2 1 JUNCTION BOX L1 L2 G (1) CIRCUIT OF 8 MODULES (N)20A/2P L2 L1 L1 L2 G JUNCTION BOX (OPTIONAL IF UF-B CABLE USED FOR ENTIRE HOMERUN) L1 L2 G 3 G JUNCTION BOX (1) CIRCUIT OF 9 MODULES + -+ -++--++-- + -+ -++--++-- (17) JinKO Solar Eagle JKM375M-6RL3-B UL 1703 COMPLIANT (17) Enphase Energy IQ7PLUS-72-2-US MICRO INVERTERS UL 1741 COMPLIANT 9 MODULES MAX FOR ALL SUB-BRANCH CIRCUIT(S) TO COMPLY WITH VRISE CALCSEnphase IQ Combiner 3 X-IQ-AM1-240-3 (SOLAR LOADS ONLY) DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. ENPHASE ENERGY 360621 June 16, 2021SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED PV5 ELEC. 3 LINE DIAG. 0 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM 17 INVERTERS x 290.4 W AC = 4.94 kW AC PANEL WATTAGE = 375 W DC Utility Company: Duke Energy IN Permit Issuer: City of Carmel 10/21/21 DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. ENPHASE ENERGY 360621 June 16, 2021SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED PV6 ELEC. CALCS. 0 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-47] AND [NEC 250-50] THROUGH [NEC 250-60] SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64C.]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO [NEC 690.45] AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE (#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF #4 AWG OR LARGER) 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM #8AWG WHEN INSULATED, #6AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR) 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B). 300.4 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC-ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8] FOR MULTIPLE CONDUCTORS 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8" ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(a), NEC TABLE 310.15(B)(3)(a),& NEC 310.15(B)(3)(c)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY * USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE-2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH NEC 230.6(4) AND SECURED NO GREATER THAN 6' APART PER NEC 330.30(B). 10/21/21 DATE DRAWING BY PROJECT NUMBER SHEET NAME PAGE NUMBER REVISION CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. ENPHASE ENERGY 360621 June 16, 2021SITE INFORMATION:Jonathan House11095 Huntington CtCarmel, Indiana 46033DC SYSTEM SIZE: 6.375 kW DCCONTRACTOR: BRS FIELD OPS 385.498.6700 PV INSTALLATION PROFESSIONAL Scott Gurney # PV-011719-015866 NABCEP CERTIFIED PV8 LABELS 0 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM LABEL 1 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B), NEC 705.22] LABEL 2 AT EACH DC DISCONNECTING MEANS, INCLUDING THE DC DISCONNECT AT THE INVERTER. [NEC 690.53, NEC 690.13(B)] LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 4 IF INTERCONNECTING ON THE LOAD SIDE, INSTALL THIS LABEL ANYWHERE THAT IS POWERED BY BOTH THE UTILITY AND THE SOLAR PV SYSTEM: THE MAIN SERVICE PANEL AND SUB-PANELS. [NEC 705.12(B)(3)] LABEL 5 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 10 (ONLY IF 3 OR MORE SUPPLY SOURCES TO A BUSBAR) SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES. [NEC 705.12(B)(2)(3)(C)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN[NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] LABEL 11 PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT LOCATION IF ALL ELECTRICAL POWER SOURCE DISCONNECTING MEANS (SOLAR ARRAY RAPID SHUTDOWN SWITCH) ARE GROUPED AND IN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 690.56(C) & NEC 705.10]. 2 7 9 5 6 1 1 1 5 6 8 1 *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) LABELING DIAGRAM FOR STRING INV. / DC OPTIMIZER INV.: AC JUNCTION BOX OR AC COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT (IF REQ. / INSTALLED) EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) LABELING DIAGRAM FOR MICRO INV.: 3 4 7 3 5 1 1 1 5 3 4 1 9 11 OR OR PLACARD 11 OR OR PLACARD OR 3 3 AC DISCONNECT (IF REQ. / INSTALLED) IF BREAKER USED IF BREAKER USED 3 4 IF BREAKER USED 3 4 IF BREAKER USED & & & & 10 1 3 4 10 LABEL 12 PERMANENT DIRECTORY TO BE LOCATED AT AC COMBINER PANEL [NEC 110.21(B)] 12 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20 The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while EGLMIZMRKXLILMKLIWXW]WXIQIJƤGMIRG] Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase )RPMKLXIRƎQSRMXSVMRKERHEREP]WMWWSJX[EVI IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading [EVVERX]SJYTXS]IEVW Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install · Lightweight and simple · Faster installation with improved, lighter two-wire cabling · Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable · Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell* modules · More than a million hours of testing · Class II double-insulated enclosure · UL listed Smart Grid Ready · Complies with advanced grid support, voltage and frequency ride-through requirements · Remotely updates to respond to changing grid requirements ŵ'SRƤKYVEFPIJSVZEV]MRKKVMHTVSƤPIW · Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell/144 half-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com k)RTLEWI)RIVK]%PPVMKLXWVIWIVZIH)RTLEWIXLI)RTLEWIPSKS)RTLEWI-5)RTLEWI-5)RTLEWI-5&EXXIV] )RTLEWI)RPMKLXIR)RTLEWI-5)RZS]ERHSXLIVXVEHIQEVOWSVWIVZMGIREQIWEVIXLIXVEHIQEVOWSJ)RTLEWI)RIVK]-RG(EXEWYFNIGXXSGLERKI INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2- US Commonly used module pairings¹ 235 W - 350 W + 235 W - 440 W + Module compatibility 60-cell/120 half-cell PV modules only 60-cell/120 half-cell and 72- cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A 4:EVVE]GSRƤKYVEXMSR 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range² 240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³ 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable) 0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V 4IEOIJƤGMIRG]97.6 % 97.6 % 97.5 % 97.3 % ')'[IMKLXIHIJƤGMIRG]97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range -40º C to +65º C Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20 The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 (X-IQ-AM1-240-3) To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart · Includes IQ Envoy for communication and control · Flexible networking supports Wi-Fi, Ethernet, or cellular · Optional AC receptacle available for PLC bridge · Provides production metering and optional consumption monitoring Simple · Reduced size from previous combiner · Centered mounting brackets support single stud mounting · Supports back and side conduit entry · Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) · 80 A total PV or storage branch circuits Reliable ŵ(YVEFPI2680GIVXMƤIH 2)1%X]TI 3R enclosure · Five-year limited warranty · UL listed To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the trademarks of Enphase Energy, Inc. 2019-11-04 MODEL NUMBER IQ Combiner 3 <-5%1 IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production QIXIVMRK %27-' ERHSTXMSREPconsumption QSRMXSVMRK   ACCESSORIES and REP LACEMENT PARTS (not included, order separately) )RTLEWI1SFMPI'SRRIGXƎ ')0013()1 +]IEV HEXE TPER ')0013()1 +]IEV HEXE TPER ')0013()11 +FEWIH08)1]IEVHEXETPER Plug and play industrial grade cellular modem with data plan for systems up to 60 QMGVSMRZIVXIVW %ZEMPEFPIMR XLI97'EREHE1I\MGS4YIVXS 6MGSERHXLI97 :MVKMR -WPERHW [LIVIXLIVIMW EHIUYEXIGIPPYPEV WIVZMGIMRXLIMRWXEPPEXMSR EVIE 'SRWYQTXMSR 1SRMXSVMRK'8 CT-200-SPLIT Split core current transformers enable whole home consumption QIXIVMRK   'SRWYQTXMSR QSRMXSVMRKMWVIUYMVIHJSV )RTLEWI7XSVEKI7]WXIQW Wireless USB adapter '3117/-8 -RWXEPPIHEXXLI-5)RZS]*SVGSQQYRMGEXMSRW [MXL)RTLEWI)RGLEVKIƎWXSVEKIERH)RTLEWI )RTS[IVƎWQEVX W[MXGL-RGPYHIW 97&GEFPIJSVGSRRIGXMSRXS-5)RZS]SV)RTLEWI-5'SQFMRIVƎ ERHEPPS[W VIHYRHERX [MVIPIWW GSQQYRMGEXMSR[MXL )RGLEVKIERH)RTS[IV Circuit Breakers &6/% &6/% &6/%4 7YTTSVXW )EXSR&6&6&6&6&6&6ERH&6GMVGYMX FVIEOIVW 'MVGYMX FVIEOIVTSPI%)EXSR&6 'MVGYMX FVIEOIVTSPI%)EXSR &6 Circuit breaker, 2 pole, 20A, Eaton BR220 )40'Power line carrier (communication bridge pair), quantity - one pair <%409+%GGIWWSV]VIGITXEGPIJSV4S[IV 0MRI'EVVMIV MR-5'SQFMRIV  VIUYMVIHJSV)40' XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SP ECIFICATIONS Rating Continuous duty System voltage :%',^ Eaton BR series busbar rating % 1E\GSRXMRYSYW GYVVIRX VEXMRK SYXTYX XSKVMH % 1E\JYWIGMVGYMX VEXMRK SYXTYX 90 A &VERGL GMVGYMXW WSPEVERHSV WXSVEKI 9T XS JSYV TSPI)EXSR &6 WIVMIW (MWXVMFYXIH+IRIVEXMSR (+ FVIEOIVW SRP] RSX MRGPYHIH 1E\GSRXMRYSYW GYVVIRX VEXMRK MRTYX JVSQ 4: 64 A 1E\XSXEPFVERGL GMVGYMXFVIEOIV VEXMRK MRTYX %SJ HMWXVMFYXIHKIRIVEXMSR  %[MXL -5)RZS]FVIEOIVMRGPYHIH 4VSHYGXMSR 1IXIVMRK'8 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA (MQIRWMSRW ;\,\(  \  \  GQ ű\ ű\ ű  ,IMKLX MW  GQ [MXL QSYRXMRKFVEGOIXW  Weight OK PFW Ambient temperature range {' XS {' {XS {* Cooling Natural convection, plus heat shield Enclosure environmental rating 3YXHSSV2680GIVXMƤIH2)1%X]TI6TSP]GEVFSREXIGSRWXVYGXMSR Wire sizes · %XS %FVIEOIVMRTYXW XS  %;+ GSTTIV GSRHYGXSVW · %FVIEOIV FVERGL MRTYXXS%;+GSTTIV GSRHYGXSVW · 1EMR PYKGSQFMRIHSYXTYXXS %;+GSTTIVGSRHYGXSVW · 2IYXVEP ERHKVSYRHXS GSTTIVGSRHYGXSVW %P[E]W JSPPS[PSGEP GSHIVIUYMVIQIRXW JSVGSRHYGXSV WM^MRK Altitude 8S QIXIVW JIIX INTERNET CONNECTION OP TIONS Integrated Wi-Fi FKR Ethernet 3TXMSREP'EX) SV 'EX  984 )XLIVRIX GEFPI RSX MRGPYHIH Cellular 3TXMSREP')0013()1 + SV')0013()1 + SV')0013()11 +FEWIH08)1 (not included) COMP LIANCE Compliance, Combiner 90 '%2'7%'2S'*64EVX 'PEWW &-')7 4VSHYGXMSR QIXIVMRK%27-'EGGYVEG]GPEWW  4:TVSHYGXMSR Compliance, IQ Envoy 90 '%2'7%2S Enphase IQ Combiner 3 10/21/21 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 6(67( $0(5,&$1)25.87  :::%/8(5$9(162/$5&20 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20  PP LQ   PP LQ   PP LQ   PP LQ   PP LQ   PP LQ   PP LQ   PP LQ  ,7(0123$57180%(5 '(6&5,37,21 47< -%%RG\Z(=/2. 7(&+12/2*< 32/<&$5%21$7(:,7+89 ,1+,%,7256  -%/LGZ*DVNHW 32/<&$5%21$7(:,7+89 ,1+,%,7256   [µ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lbs-in UL Standard 1741, NEMA 3R 1.3 lbs EZ Solar SLC, UT USA Phone (385) 202-4150 www.ezsolarproducts.com 10-32 x 1” Phillips pan head bolt 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20  PP LQ   PP LQ   PP LQ    P P 5   LQ  PP LQ  PP LQ   PP LQ   PP LQ   PP LQ  PP LQ   PP LQ  $ $ ,QGHQW  PP LQ   PP LQ   PP LQ   PP LQ   PP LQ  6(&7,21$$ 6&$/( (=62/$5 '21276&$/('5$:,1* -% 6+((72) 81/(6627+(5:,6(63(&,),(' 6&$/(:(,*+7 5(9':*12 % 6,=( 7,7/( 1$0('$7( &200(176 4$ 0)*$335 (1*$335 &+(&.(' '5$:1 ),1,6+ 0$7(5,$/ ,17(535(7*(20(75,& 72/(5$1&,1*3(5 ',0(16,216$5(,1,1&+(6 72/(5$1&(6 )5$&7,21$/ $1*8/$50$&+%(1' 7:23/$&('(&,0$/ 7+5((3/$&('(&,0$/ $33/,&$7,21 86('211(;7$66< 35235,(7$5<$1'&21),'(17,$/ 7+(,1)250$7,21&217$,1(',17+,6 '5$:,1*,67+(62/(3523(57<2) (=62/$5 $1<5(352'8&7,21,13$57 25$6$:+2/(:,7+2877+(:5,77(1 3(50,66,212)(=62/$5,6352+,%,7(' $$ %%         10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20  PP LQ   PP LQ  $ $  PP LQ   PP LQ  6(&7,21$$ 6&$/( /,'29(5+$1* 2876,'(,16,'( $$ %%         (=62/$5 '21276&$/('5$:,1* -% 6+((72) 81/(6627+(5:,6(63(&,),(' 6&$/(:(,*+7 5(9':*12 % 6,=( 7,7/( 1$0('$7( &200(176 4$ 0)*$335 (1*$335 &+(&.(' '5$:1 ),1,6+ 0$7(5,$/ ,17(535(7*(20(75,& 72/(5$1&,1*3(5 ',0(16,216$5(,1,1&+(6 72/(5$1&(6 )5$&7,21$/ $1*8/$50$&+%(1' 7:23/$&('(&,0$/ 7+5((3/$&('(&,0$/ $33/,&$7,21 86('211(;7$66< 35235,(7$5<$1'&21),'(17,$/ 7+(,1)250$7,21&217$,1(',17+,6 '5$:,1*,67+(62/(3523(57<2) (=62/$5$1< 5(352'8&7,21,13$5725$6$:+2/( :,7+2877+(:5,77(13(50,66,212) ,16(57&203$1<1$0(+(5(!,6 352+,%,7(' 10/21/21 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 10/21/21 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 10/21/21 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 10/21/21 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20 SFM SUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE SYSTEM COMPONENTS C TrimrailTM Flashkit Sub-Components: /)RRW +H[EROW 7ULGULYHQXW &KDQQHO1XW 6FRFNHW+HDG&DS6FUHZ &KDQQHO6OLGHUZJURPPHW 3" Wide Flashing 6WUXFWXUDO6FUHZ 66(3'0:DVKHU Functions: · $WWDFK7ULPUDLOTMWRURRIDWWDFKPHQWˊDVKLQJ · 3DWHQWHGURRIVHDOLQJWHFKQRORJ\DWURRIDWWDFKPHQWSRLQW Features: · 6ORWSURYLGHVYHUWLFDODGMXVWPHQWVWROHYHODUUD\ · 6OLGHUSURYLGHVQRUWKVRXWKDGMXVWPHQWDORQJWKH VORSHRIWKHURRI · Shed and Seal Technology TrimrailTM and Module Clips Sub-Components: Trim Rail Module Clip 7%ROW 7UL'ULYH1XW TrimrailTM Functions: · 5HTXLUHGIURQWURZVWUXFWXUDOVXSSRUW ZLWKPRGXOHFOLSV · 0RGXOHPRXQWLQJ · ,QVWDOODWLRQDLG · $HVWKHWLFWULP Features: · 0RXQWVGLUHFWO\WR/IHHW · $OLJQVDQGFDSWXUHVPRGXOHOHDGLQJHGJH · 6XSSRUWVGLVFUHWHPRGXOHWKLFNQHVVHVIURP 38, and 40mm Module Clips Functions: · 5HTXLUHGIURQWURZVWUXFWXUDOVXSSRUW ZLWKWULPUDLO · 0RGXOHPRXQWLQJ Features: · 0RXQWVWR7ULPUDLOTMZLWK7EROWDQGWULGULYHQXW · 0DQXDOO\DGMXVWDEOHWRˉWPRGXOHWKLFNQHVVHV DQGPP TrimrailTM Splice Sub-Components: 6WUXFWXUDO6SOLFH([WUXVLRQ %RQGLQJ&OLS Functions: · )URQWURZVWUXFWXUDOVXSSRUW · ,QVWDOODWLRQDLG · 6WUXFWXUDOO\FRQQHFWVSLHFHVRI7ULPUDLOTM · (OHFWULFDOO\ERQGVSLHFHVRI7ULPUDLOTM Features: · $OLJQVDQGFRQQHFWV7ULPUDLOTM pieces · 7RROOHVVLQVWDOODWLRQ n o p q n o p q r t n ou s 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20 SFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE SYSTEM COMPONENTS D SFM Slider Flashkit Sub-Components: 6OLGHU ZJURPPHW 6WUXFWXUDO 6FUHZ 66 (3'0 ZDVKHU :LGH)ODVKLQJ Functions: · 3DWHQWHG 6KHG 6HDO URRIVHDOLQJ WHFKQRORJ\DWURRI DWWDFK- PHQWSRLQW · )RU XVH ZLWK FRPSDWLEOH 0LFURUDLO RU $WWDFKHG 6SOLFHV Features: · 6OLGHU SURYLGHV QRUWKVRXWK DGMXVWPHQWDORQJ WKH VORSH RI WKH URRI · Shed and Seal Technology Wire Bonding Clip w/ 8AWG Functions: · 5RZWR URZERQGLQJ · 0RGXOH WR 7ULPUDLOTM ERQGLQJ · Single Use Only Features: 7RROOHVV LQVWDOODWLRQ MLPE Mounting Assembly Sub-Components: 0/3(0RXQW%DVH 6RFNHW+HDG &DS 6FUHZ %RQGLQJ 3LQ Functions: · 6HFXUHO\PRXQWV 0/3(WR PRGXOH IUDPHV · 0/3(WR PRGXOH ERQGLQJ Features: · 0RXQWV HDVLO\WR W\SLFDO PRGXOH ˊDQJH · UL2703 Recognized 0/3( 0RGXOH /HYHO 3RZHU (OHFWURQLFV HJPLFURLQYHUWHU RU SRZHU RSWLPL]HU Module-to-Module N-S Bonding Sub-Components: &ODPS %RQGLQJ 3LQV  6RFNHW+HDG &DS 6FUHZ &ODPS %DVH Functions/ Features: · 5RZWR URZERQGLQJ · Single Use Only · )LWV PRGXOH VL]HV PP Trim -to- Module Bonding Clamp and Floating Trim Clamp Sub-Components: :HGJH %RQGLQJ 3LQ 7%ROW 1XW &DVW%DVH Functions/ Features: · 0RGXOH WR 7ULPUDLOTM ERQGLQJVLQJOH XVH RQO\ · $WWDFKHV 7ULPUDLOTM WR PRGXOH ZKHQ IHZHU WKDQ UDIWHU DWWDFKPHQW SRLQWV DUH DYDLODEOH · )LWV PRGXOH VL]HV PP · )LWV PRGXOH VL]HV PP o n p n q p n p o o nr p o q 10/21/21 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/ 6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20 SFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE FLASHING & SLIDERS G PILOT HOLES: 'ULOOSLORWKROHVIRUODJVFUHZVRU VWUXFWXUDOVFUHZV DVQHFHVVDU\ DW PDUNHGDWWDFKHPHQWSRLQWV FLASHINGS: 3ODFHˊDVKLQJV INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: · ,QVHUWˊDVKLQJVSHUPDQXIDFWXUHULQVWUXFWLRQV NOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" · $WWDFKVOLGHUVWRUDIWHUV · 9HULI\SURSHUURZWRURZVSDFLQJIRUPRGXOHVL]H 0RG16 · (QVXUHWKDW7ULPUDLO70URRIDWWDFKPHQWVLQHDFKURZKDYHVXIˉFLHQW HQJDJHPHQWZLWKVOLGHUGRYHWDLOVIRUSURSHUDWWDFKPHQW INSTALL SLIDERS AND ROOF ATTACHMENTS: )ROORZPDQXIDFWXUHULQVWUXFWLRQV IRUˊDVKLQJLQVWDOODWLRQSURFHGXUHV NOTE: If N-S module edge is within 1” of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required. × UP-SLOPE DOWN-SLOPE Mod NS + 1" Mod NS + 1" N/S MODULE EDGE Rotate Slider Cut Shingles as Required Less Than 1"  10/21/21